Action not permitted
Modal body text goes here.
CVE-2021-37202
Vulnerability from cvelistv5
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-208530.pdf | Patch, Vendor Advisory | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf | Patch, Vendor Advisory |
▼ | Vendor | Product |
---|---|---|
Siemens | NX 1980 Series | |
Siemens | Solid Edge SE2021 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T01:16:04.005Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-208530.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "NX 1980 Series", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1984" } ] }, { "product": "Solid Edge SE2021", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c SE2021MP8" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in NX 1980 Series (All versions \u003c V1984), Solid Edge SE2021 (All versions \u003c SE2021MP8). The IFC adapter in affected application contains a use-after-free vulnerability that could be triggered while parsing user-supplied IFC files. An attacker could leverage this vulnerability to execute code in the context of the current process." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-416", "description": "CWE-416: Use After Free", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-09-28T11:12:25", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-208530.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-37202", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "NX 1980 Series", "version": { "version_data": [ { "version_value": "All versions \u003c V1984" } ] } }, { "product_name": "Solid Edge SE2021", "version": { "version_data": [ { "version_value": "All versions \u003c SE2021MP8" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in NX 1980 Series (All versions \u003c V1984), Solid Edge SE2021 (All versions \u003c SE2021MP8). The IFC adapter in affected application contains a use-after-free vulnerability that could be triggered while parsing user-supplied IFC files. An attacker could leverage this vulnerability to execute code in the context of the current process." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-416: Use After Free" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-208530.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-208530.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-37202", "datePublished": "2021-09-14T10:47:55", "dateReserved": "2021-07-21T00:00:00", "dateUpdated": "2024-08-04T01:16:04.005Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2021-37202\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2021-09-14T11:15:26.397\",\"lastModified\":\"2021-11-18T16:08:06.813\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in NX 1980 Series (All versions \u003c V1984), Solid Edge SE2021 (All versions \u003c SE2021MP8). The IFC adapter in affected application contains a use-after-free vulnerability that could be triggered while parsing user-supplied IFC files. An attacker could leverage this vulnerability to execute code in the context of the current process.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en NX 1980 Series (Todas las versiones anteriores a V1984), Solid Edge SE2021 (Todas las versiones anteriores a SE2021MP8). El adaptador IFC de la aplicaci\u00f3n afectada contiene una vulnerabilidad de uso despu\u00e9s de libre que podr\u00eda activarse mientras se analizan los archivos IFC suministrados por el usuario. Un atacante podr\u00eda aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del proceso actual\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:P\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\",\"baseScore\":6.8},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-416\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:nx_1980:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1984\",\"matchCriteriaId\":\"D3A09766-0171-4DDA-9BF9-D379DA134571\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"se2021\",\"matchCriteriaId\":\"576A303A-66CA-4694-AA54-9EB0137C24F1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"39D237BD-EE55-4B40-ABC3-194C4BF7C6CD\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack1:*:*:*:*:*:*\",\"matchCriteriaId\":\"49F5649A-349C-42C6-AFFF-CEE1ABC14E67\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack2:*:*:*:*:*:*\",\"matchCriteriaId\":\"756343AA-DB57-40F7-94FA-84BFCDEB6159\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack3:*:*:*:*:*:*\",\"matchCriteriaId\":\"36B0DD28-653E-4069-AB5A-38F8EFEB36CA\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack4:*:*:*:*:*:*\",\"matchCriteriaId\":\"82090774-D894-41C8-82F1-A48A8707E9BB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack5:*:*:*:*:*:*\",\"matchCriteriaId\":\"BD346D22-9B5D-4A50-94E2-1F5C8D391EC3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack6:*:*:*:*:*:*\",\"matchCriteriaId\":\"1466AEE0-4A5C-4E2D-80B8-43680F60FC31\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack7:*:*:*:*:*:*\",\"matchCriteriaId\":\"A4173D09-C317-45FF-ABA4-39E5592862F8\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-208530.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}" } }
ghsa-pfcx-4587-hw8m
Vulnerability from github
A vulnerability has been identified in NX 1980 Series (All versions < V1984). The IFC adapter in affected application contains a use-after-free vulnerability that could be triggered while parsing user-supplied IFC files. An attacker could leverage this vulnerability to execute code in the context of the current process.
{ "affected": [], "aliases": [ "CVE-2021-37202" ], "database_specific": { "cwe_ids": [ "CWE-416" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2021-09-14T11:15:00Z", "severity": "HIGH" }, "details": "A vulnerability has been identified in NX 1980 Series (All versions \u003c V1984). The IFC adapter in affected application contains a use-after-free vulnerability that could be triggered while parsing user-supplied IFC files. An attacker could leverage this vulnerability to execute code in the context of the current process.", "id": "GHSA-pfcx-4587-hw8m", "modified": "2022-05-24T19:14:30Z", "published": "2022-05-24T19:14:30Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2021-37202" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-208530.pdf" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf" } ], "schema_version": "1.4.0", "severity": [] }
var-202109-1826
Vulnerability from variot
A vulnerability has been identified in NX 1980 Series (All versions < V1984), Solid Edge SE2021 (All versions < SE2021MP8). The IFC adapter in affected application contains a use-after-free vulnerability that could be triggered while parsing user-supplied IFC files. An attacker could leverage this vulnerability to execute code in the context of the current process. Pillow is a Python-based image processing library. There is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202109-1826", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "solid edge", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "se2021" }, { "model": "solid edge", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "se2021" }, { "model": "nx 1980", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1984" } ], "sources": [ { "db": "NVD", "id": "CVE-2021-37202" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:nx_1980:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1984", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "se2021", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:-:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack1:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack2:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack3:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack4:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack5:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack6:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack7:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-37202" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Xina1i and Trend Micro\u2019s Zero Day Initiative reported these vulnerabilities to Siemens and CISA.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202109-938" } ], "trust": 0.6 }, "cve": "CVE-2021-37202", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": null, "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULMON", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "id": "CVE-2021-37202", "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "MEDIUM", "trust": 1.1, "userInteractionRequired": null, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.8, "id": "CVE-2021-37202", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-37202", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202109-938", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-37202", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-37202" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202109-938" }, { "db": "NVD", "id": "CVE-2021-37202" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in NX 1980 Series (All versions \u003c V1984), Solid Edge SE2021 (All versions \u003c SE2021MP8). The IFC adapter in affected application contains a use-after-free vulnerability that could be triggered while parsing user-supplied IFC files. An attacker could leverage this vulnerability to execute code in the context of the current process. Pillow is a Python-based image processing library. \nThere is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements", "sources": [ { "db": "NVD", "id": "CVE-2021-37202" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "VULMON", "id": "CVE-2021-37202" } ], "trust": 1.53 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "SIEMENS", "id": "SSA-728618", "trust": 1.7 }, { "db": "SIEMENS", "id": "SSA-208530", "trust": 1.7 }, { "db": "NVD", "id": "CVE-2021-37202", "trust": 1.7 }, { "db": "CS-HELP", "id": "SB2021041363", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6 }, { "db": "ICS CERT", "id": "ICSA-21-287-06", "trust": 0.6 }, { "db": "ICS CERT", "id": "ICSA-21-257-09", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021092905", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021091517", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2021.3454", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202109-938", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-37202", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-37202" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202109-938" }, { "db": "NVD", "id": "CVE-2021-37202" } ] }, "id": "VAR-202109-1826", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.19128205 }, "last_update_date": "2022-05-04T08:28:05.251000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Siemens NX Remediation of resource management error vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=164125" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=332f5edc8b55cb21d1b9cbee1c6ab360" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=3b85ee03e935aff52e55e7402b3926a1" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-37202" }, { "db": "CNNVD", "id": "CNNVD-202109-938" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-416", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2021-37202" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-208530.pdf" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021041363" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-287-06" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021091517" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2021.3454" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-37202" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-257-09" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021092905" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/416.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://cert-portal.siemens.com/productcert/txt/ssa-208530.txt" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-37202" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202109-938" }, { "db": "NVD", "id": "CVE-2021-37202" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-37202" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "CNNVD", "id": "CNNVD-202109-938" }, { "db": "NVD", "id": "CVE-2021-37202" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-09-14T00:00:00", "db": "VULMON", "id": "CVE-2021-37202" }, { "date": "2021-04-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2021-09-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202109-938" }, { "date": "2021-09-14T11:15:00", "db": "NVD", "id": "CVE-2021-37202" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-09-28T00:00:00", "db": "VULMON", "id": "CVE-2021-37202" }, { "date": "2021-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" }, { "date": "2021-10-19T00:00:00", "db": "CNNVD", "id": "CNNVD-202109-938" }, { "date": "2021-11-18T16:08:00", "db": "NVD", "id": "CVE-2021-37202" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202109-938" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Pillow Buffer error vulnerability", "sources": [ { "db": "CNNVD", "id": "CNNVD-202104-975" } ], "trust": 0.6 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202104-975" } ], "trust": 0.6 } }
gsd-2021-37202
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2021-37202", "description": "A vulnerability has been identified in NX 1980 Series (All versions \u003c V1984), Solid Edge SE2021 (All versions \u003c SE2021MP8). The IFC adapter in affected application contains a use-after-free vulnerability that could be triggered while parsing user-supplied IFC files. An attacker could leverage this vulnerability to execute code in the context of the current process.", "id": "GSD-2021-37202" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2021-37202" ], "details": "A vulnerability has been identified in NX 1980 Series (All versions \u003c V1984), Solid Edge SE2021 (All versions \u003c SE2021MP8). The IFC adapter in affected application contains a use-after-free vulnerability that could be triggered while parsing user-supplied IFC files. An attacker could leverage this vulnerability to execute code in the context of the current process.", "id": "GSD-2021-37202", "modified": "2023-12-13T01:23:09.795564Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-37202", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "NX 1980 Series", "version": { "version_data": [ { "version_value": "All versions \u003c V1984" } ] } }, { "product_name": "Solid Edge SE2021", "version": { "version_data": [ { "version_value": "All versions \u003c SE2021MP8" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in NX 1980 Series (All versions \u003c V1984), Solid Edge SE2021 (All versions \u003c SE2021MP8). The IFC adapter in affected application contains a use-after-free vulnerability that could be triggered while parsing user-supplied IFC files. An attacker could leverage this vulnerability to execute code in the context of the current process." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-416: Use After Free" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-208530.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-208530.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:nx_1980:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1984", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "se2021", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:-:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack1:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack2:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack3:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack4:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack5:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack6:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack7:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-37202" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "A vulnerability has been identified in NX 1980 Series (All versions \u003c V1984), Solid Edge SE2021 (All versions \u003c SE2021MP8). The IFC adapter in affected application contains a use-after-free vulnerability that could be triggered while parsing user-supplied IFC files. An attacker could leverage this vulnerability to execute code in the context of the current process." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-416" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-208530.pdf", "refsource": "MISC", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-208530.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf", "refsource": "MISC", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "userInteractionRequired": true }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9 } }, "lastModifiedDate": "2021-11-18T16:08Z", "publishedDate": "2021-09-14T11:15Z" } } }
icsa-21-287-06
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "names": [ "Xina1i" ], "summary": "reporting these vulnerabilities to Siemens and CISA" }, { "organization": "Trend Micro \u0027s Zero Day Initiative", "summary": "reporting these vulnerabilities to Siemens and CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could lead the application to crash or allow arbitrary code execution on the target host system.", "title": "Risk evaluation" }, { "category": "other", "text": "Multiple Sectors", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "external", "summary": "SSA-728618: Multiple Vulnerabilities in Solid Edge before SE2021MP8 - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-728618.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-287-06 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-287-06.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-287-06 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-287-06" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ics/tips/ICS-TIP-12-146-01B" }, { "category": "external", "summary": "SSA-728618: Multiple Vulnerabilities in Solid Edge before SE2021MP8 - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf" }, { "category": "external", "summary": "SSA-728618: Multiple Vulnerabilities in Solid Edge before SE2021MP8 - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-728618.txt" } ], "title": "Siemens Solid Edge", "tracking": { "current_release_date": "2021-10-14T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-21-287-06", "initial_release_date": "2021-10-14T00:00:00.000000Z", "revision_history": [ { "date": "2021-10-14T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-21-287-06 Siemens Solid Edge" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c SE2021MP8", "product": { "name": "Solid Edge SE2021", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "Solid Edge SE2021" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2021-37202", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "The IFC adapter in affected application contains a use-after-free vulnerability that could be triggered while parsing user-supplied IFC files. An attacker could leverage this vulnerability to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-37202 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-37202.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-37202" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to SE2021MP8 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Avoid opening files from unknown sources in Solid Edge", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-37202" }, { "cve": "CVE-2021-37203", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The plmxmlAdapterIFC.dll contains an out-of-bounds read while parsing user supplied IFC files which could result in a read past the end of an allocated buffer. This could allow an attacker to cause a denial-of-service condition or read sensitive information from memory locations.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-37203 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-37203.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-37203" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to SE2021MP8 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Avoid opening files from unknown sources in Solid Edge", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-37203" }, { "cve": "CVE-2021-41533", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to an out of bounds read past the end of an allocated buffer when parsing JT files.\n\nAn attacker could leverage this vulnerability to leak information in the context of the current process (ZDI-CAN-13565).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-41533 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-41533.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-41533" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to SE2021MP8 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Avoid opening files from unknown sources in Solid Edge", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-41533" }, { "cve": "CVE-2021-41534", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to an out of bounds read past the end of an allocated buffer when parsing JT files.\n\nAn attacker could leverage this vulnerability to leak information in the context of the current process (ZDI-CAN-13703).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-41534 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-41534.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-41534" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to SE2021MP8 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Avoid opening files from unknown sources in Solid Edge", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-41534" }, { "cve": "CVE-2021-41535", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "The affected application contains a use-after-free vulnerability while parsing OBJ files.\n\nAn attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13771).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-41535 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-41535.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-41535" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to SE2021MP8 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Avoid opening files from unknown sources in Solid Edge", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-41535" }, { "cve": "CVE-2021-41536", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "The affected application contains a use-after-free vulnerability while parsing OBJ files.\n\nAn attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13778).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-41536 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-41536.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-41536" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to SE2021MP8 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Avoid opening files from unknown sources in Solid Edge", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-41536" }, { "cve": "CVE-2021-41537", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "The affected application contains a use-after-free vulnerability while parsing OBJ files.\n\nAn attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13789).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-41537 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-41537.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-41537" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to SE2021MP8 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Avoid opening files from unknown sources in Solid Edge", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-41537" }, { "cve": "CVE-2021-41538", "cwe": { "id": "CWE-824", "name": "Access of Uninitialized Pointer" }, "notes": [ { "category": "summary", "text": "The affected application is vulnerable to information disclosure by unexpected access to an uninitialized pointer while parsing user-supplied OBJ files.\n\nAn attacker could leverage this vulnerability to leak information from unexpected memory locations (ZDI-CAN-13770).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-41538 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-41538.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-41538" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to SE2021MP8 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Avoid opening files from unknown sources in Solid Edge", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-41538" }, { "cve": "CVE-2021-41539", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "The affected application contains a use-after-free vulnerability while parsing OBJ files.\n\nAn attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13773).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-41539 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-41539.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-41539" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to SE2021MP8 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Avoid opening files from unknown sources in Solid Edge", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-41539" }, { "cve": "CVE-2021-41540", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "The affected application contains a use-after-free vulnerability while parsing OBJ files.\n\nAn attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13776).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-41540 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-41540.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-41540" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to SE2021MP8 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Avoid opening files from unknown sources in Solid Edge", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-41540" } ] }
icsa-21-257-09
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens", "summary": "reporting these vulnerabilities to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could lead to an access violation and to arbitrary code execution on the target host system.", "title": "Risk evaluation" }, { "category": "other", "text": "Critical Manufacturing", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take the following measures to protect themselves from social engineering attacks:", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "external", "summary": "SSA-208530: File parsing vulnerabilities in IFC adapter in NX - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-208530.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-257-09 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-257-09.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-257-09 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-257-09" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ncas/tips/ST04-014" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ics/tips/ICS-TIP-12-146-01B" }, { "category": "external", "summary": "SSA-208530: File parsing vulnerabilities in IFC adapter in NX - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-208530.pdf" }, { "category": "external", "summary": "SSA-208530: File parsing vulnerabilities in IFC adapter in NX - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-208530.txt" } ], "title": "Siemens NX", "tracking": { "current_release_date": "2021-09-15T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-21-257-09", "initial_release_date": "2021-09-15T00:00:00.000000Z", "revision_history": [ { "date": "2021-09-15T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-21-257-09 Siemens NX" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c V1984", "product": { "name": "NX 1980 Series", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "NX 1980 Series" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2021-37202", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "The IFC adapter in affected application contains a use-after-free vulnerability that could be triggered while parsing user-supplied IFC files. An attacker could leverage this vulnerability to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-37202 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-37202.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-37202" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V1984 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Avoid opening files from unknown sources in NX", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-37202" }, { "cve": "CVE-2021-37203", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The plmxmlAdapterIFC.dll contains an out-of-bounds read while parsing user supplied IFC files which could result in a read past the end of an allocated buffer. This could allow an attacker to cause a denial-of-service condition or read sensitive information from memory locations.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-37203 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-37203.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-37202" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V1984 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Avoid opening files from unknown sources in NX", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-37203" } ] }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.