GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

CVE-2022-1704 (GCVE-0-2022-1704)

Vulnerability from cvelistv5 – Published: 2022-08-05 15:25 – Updated: 2025-04-16 16:13
VLAI
Title
Inductive Automation Ignition
Summary
Due to an XML external entity reference, the software parses XML in the backup/restore functionality without XML security flags, which may lead to a XXE attack while restoring the backup.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-04-16 15:50 UTC
CWE
  • CWE-611 - Improper Restriction of XML External Entity Reference ('XXE')
References
Impacted products
Vendor Product Version CPE status
Inductive Automation Ignition Affected: 8.1 , ≤ 8.1.7 (custom)
Affected: All , < 7.9.21 (custom)
guessed Create a notification for this product.
Date Public
2022-07-26 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T00:10:03.916Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-207-01"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-1704",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T15:50:51.760136Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T16:13:45.512Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Ignition",
          "vendor": "Inductive Automation",
          "versions": [
            {
              "lessThanOrEqual": "8.1.7",
              "status": "affected",
              "version": "8.1",
              "versionType": "custom"
            },
            {
              "lessThan": "7.9.21",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Keval Shah reported this vulnerability to CISA"
        }
      ],
      "datePublic": "2022-07-26T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Due to an XML external entity reference, the software parses XML in the backup/restore functionality without XML security flags, which may lead to a XXE attack while restoring the backup."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 7.6,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-611",
              "description": "CWE-611 Improper Restriction of XML External Entity Reference (\u0027XXE\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-05T15:25:19.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-207-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Inductive Automation recommends users upgrade the Ignition software to the latest version:\n\nInductive Automation Ignition: Version 8.1.9 or later\nInductive Automation Ignition: Version 7.9.21 or later"
        }
      ],
      "source": {
        "advisory": "ICSA-22-207-01",
        "discovery": "EXTERNAL"
      },
      "title": "Inductive Automation Ignition",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2022-07-26T17:00:00.000Z",
          "ID": "CVE-2022-1704",
          "STATE": "PUBLIC",
          "TITLE": "Inductive Automation Ignition"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Ignition",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "8.1",
                            "version_value": "8.1.7"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "All",
                            "version_value": "7.9.21"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Inductive Automation"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Keval Shah reported this vulnerability to CISA"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Due to an XML external entity reference, the software parses XML in the backup/restore functionality without XML security flags, which may lead to a XXE attack while restoring the backup."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 7.6,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:L",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-611 Improper Restriction of XML External Entity Reference (\u0027XXE\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-207-01",
              "refsource": "MISC",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-207-01"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Inductive Automation recommends users upgrade the Ignition software to the latest version:\n\nInductive Automation Ignition: Version 8.1.9 or later\nInductive Automation Ignition: Version 7.9.21 or later"
          }
        ],
        "source": {
          "advisory": "ICSA-22-207-01",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-1704",
    "datePublished": "2022-08-05T15:25:19.220Z",
    "dateReserved": "2022-05-12T00:00:00.000Z",
    "dateUpdated": "2025-04-16T16:13:45.512Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2022-1704",
      "date": "2026-09-19",
      "epss": "0.00956",
      "percentile": "0.59878"
    },
    "fkie_nvd": {
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:inductiveautomation:ignition:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "53657378-BA98-47A3-8922-B743A5A76DC1",
                  "versionEndExcluding": "7.9.21",
                  "versionStartIncluding": "7.9.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:inductiveautomation:ignition:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "66AA9D0C-35EC-4BE5-84EA-029149AF543C",
                  "versionEndExcluding": "8.1.8",
                  "versionStartIncluding": "8.1.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Due to an XML external entity reference, the software parses XML in the backup/restore functionality without XML security flags, which may lead to a XXE attack while restoring the backup."
        },
        {
          "lang": "es",
          "value": "Debido a una vulnerabilidad de tipo XML external entity, el software analiza XML en la funcionalidad backup/restore sin banderas de seguridad XML, lo que puede conllevar a un ataque de tipo XXE al restaurar la copia de seguridad"
        }
      ],
      "id": "CVE-2022-1704",
      "lastModified": "2024-11-21T06:41:17.193",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "LOW",
              "baseScore": 7.6,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "HIGH",
              "scope": "CHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:L",
              "version": "3.1"
            },
            "exploitabilityScore": 2.3,
            "impactScore": 4.7,
            "source": "ics-cert@hq.dhs.gov",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2022-08-05T16:15:11.423",
      "references": [
        {
          "source": "ics-cert@hq.dhs.gov",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-207-01"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "US Government Resource"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-207-01"
        }
      ],
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-611"
            }
          ],
          "source": "ics-cert@hq.dhs.gov",
          "type": "Primary"
        }
      ]
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "product": "Ignition",
                "vendor": "Inductive Automation",
                "versions": [
                  {
                    "lessThanOrEqual": "8.1.7",
                    "status": "affected",
                    "version": "8.1",
                    "versionType": "custom"
                  },
                  {
                    "lessThan": "7.9.21",
                    "status": "affected",
                    "version": "All",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "source": "ics-cert@hq.dhs.gov"
          }
        ],
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:inductiveautomation:ignition:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "53657378-BA98-47A3-8922-B743A5A76DC1",
                    "versionEndExcluding": "7.9.21",
                    "versionStartIncluding": "7.9.0",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:inductiveautomation:ignition:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "66AA9D0C-35EC-4BE5-84EA-029149AF543C",
                    "versionEndExcluding": "8.1.8",
                    "versionStartIncluding": "8.1.0",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "Due to an XML external entity reference, the software parses XML in the backup/restore functionality without XML security flags, which may lead to a XXE attack while restoring the backup."
          },
          {
            "lang": "es",
            "value": "Debido a una vulnerabilidad de tipo XML external entity, el software analiza XML en la funcionalidad backup/restore sin banderas de seguridad XML, lo que puede conllevar a un ataque de tipo XXE al restaurar la copia de seguridad"
          }
        ],
        "id": "CVE-2022-1704",
        "lastModified": "2026-06-17T04:22:57.110",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 7.6,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:L",
                "version": "3.1"
              },
              "exploitabilityScore": 2.3,
              "impactScore": 4.7,
              "source": "ics-cert@hq.dhs.gov",
              "type": "Secondary"
            },
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 5.9,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2022-1704",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T15:50:51.760136Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2022-08-05T16:15:11.423",
        "references": [
          {
            "source": "ics-cert@hq.dhs.gov",
            "tags": [
              "Third Party Advisory",
              "US Government Resource"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-207-01"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Third Party Advisory",
              "US Government Resource"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-207-01"
          }
        ],
        "sourceIdentifier": "ics-cert@hq.dhs.gov",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-611"
              }
            ],
            "source": "ics-cert@hq.dhs.gov",
            "type": "Secondary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2025-05-29T02:35:36+00:00",
      "cve": "CVE-2022-1704",
      "id": "CVE-2022-1704",
      "initial_release_date": "2022-07-26T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "Inductive Automation Ignition",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2022/cve-2022-1704.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T00:10:03.916Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-207-01"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-1704",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-16T15:50:51.760136Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-16T15:50:53.429Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Ignition",
              "vendor": "Inductive Automation",
              "versions": [
                {
                  "lessThanOrEqual": "8.1.7",
                  "status": "affected",
                  "version": "8.1",
                  "versionType": "custom"
                },
                {
                  "lessThan": "7.9.21",
                  "status": "affected",
                  "version": "All",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Keval Shah reported this vulnerability to CISA"
            }
          ],
          "datePublic": "2022-07-26T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Due to an XML external entity reference, the software parses XML in the backup/restore functionality without XML security flags, which may lead to a XXE attack while restoring the backup."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 7.6,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:L",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-611",
                  "description": "CWE-611 Improper Restriction of XML External Entity Reference (\u0027XXE\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-08-05T15:25:19.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-207-01"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Inductive Automation recommends users upgrade the Ignition software to the latest version:\n\nInductive Automation Ignition: Version 8.1.9 or later\nInductive Automation Ignition: Version 7.9.21 or later"
            }
          ],
          "source": {
            "advisory": "ICSA-22-207-01",
            "discovery": "EXTERNAL"
          },
          "title": "Inductive Automation Ignition",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2022-07-26T17:00:00.000Z",
              "ID": "CVE-2022-1704",
              "STATE": "PUBLIC",
              "TITLE": "Inductive Automation Ignition"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Ignition",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_name": "8.1",
                                "version_value": "8.1.7"
                              },
                              {
                                "version_affected": "\u003c",
                                "version_name": "All",
                                "version_value": "7.9.21"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Inductive Automation"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Keval Shah reported this vulnerability to CISA"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Due to an XML external entity reference, the software parses XML in the backup/restore functionality without XML security flags, which may lead to a XXE attack while restoring the backup."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 7.6,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:L",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-611 Improper Restriction of XML External Entity Reference (\u0027XXE\u0027)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-207-01",
                  "refsource": "MISC",
                  "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-207-01"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Inductive Automation recommends users upgrade the Ignition software to the latest version:\n\nInductive Automation Ignition: Version 8.1.9 or later\nInductive Automation Ignition: Version 7.9.21 or later"
              }
            ],
            "source": {
              "advisory": "ICSA-22-207-01",
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2022-1704",
        "datePublished": "2022-08-05T15:25:19.220Z",
        "dateReserved": "2022-05-12T00:00:00.000Z",
        "dateUpdated": "2025-04-16T16:13:45.512Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…