A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0). Affected products contain an open redirect vulnerability. An attacker could trick a valid authenticated user to the device into clicking a malicious link there by leading to phishing attacks.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T03:36:19.220Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-654775.pdf"
          },
          {
            "name": "20220210 SEC Consult SA-20220209 :: Open Redirect in Login Page in SIEMENS-SINEMA Remote Connect",
            "tags": [
              "mailing-list",
              "x_refsource_FULLDISC",
              "x_transferred"
            ],
            "url": "http://seclists.org/fulldisclosure/2022/Feb/20"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://packetstormsecurity.com/files/165966/SIEMENS-SINEMA-Remote-Connect-1.0-SP3-HF1-Open-Redirection.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SINEMA Remote Connect Server",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SINEMA Remote Connect Server (All versions \u003c V2.0). Affected products contain an open redirect vulnerability. An attacker could trick a valid authenticated user to the device into clicking a malicious link there by leading to phishing attacks."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-601",
              "description": "CWE-601: URL Redirection to Untrusted Site (\u0027Open Redirect\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-02-11T17:06:16",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-654775.pdf"
        },
        {
          "name": "20220210 SEC Consult SA-20220209 :: Open Redirect in Login Page in SIEMENS-SINEMA Remote Connect",
          "tags": [
            "mailing-list",
            "x_refsource_FULLDISC"
          ],
          "url": "http://seclists.org/fulldisclosure/2022/Feb/20"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://packetstormsecurity.com/files/165966/SIEMENS-SINEMA-Remote-Connect-1.0-SP3-HF1-Open-Redirection.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-23102",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SINEMA Remote Connect Server",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SINEMA Remote Connect Server (All versions \u003c V2.0). Affected products contain an open redirect vulnerability. An attacker could trick a valid authenticated user to the device into clicking a malicious link there by leading to phishing attacks."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-601: URL Redirection to Untrusted Site (\u0027Open Redirect\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-654775.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-654775.pdf"
            },
            {
              "name": "20220210 SEC Consult SA-20220209 :: Open Redirect in Login Page in SIEMENS-SINEMA Remote Connect",
              "refsource": "FULLDISC",
              "url": "http://seclists.org/fulldisclosure/2022/Feb/20"
            },
            {
              "name": "http://packetstormsecurity.com/files/165966/SIEMENS-SINEMA-Remote-Connect-1.0-SP3-HF1-Open-Redirection.html",
              "refsource": "MISC",
              "url": "http://packetstormsecurity.com/files/165966/SIEMENS-SINEMA-Remote-Connect-1.0-SP3-HF1-Open-Redirection.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-23102",
    "datePublished": "2022-02-09T15:17:29",
    "dateReserved": "2022-01-11T00:00:00",
    "dateUpdated": "2024-08-03T03:36:19.220Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2022-23102\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2022-02-09T16:15:15.617\",\"lastModified\":\"2022-02-18T14:51:26.057\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SINEMA Remote Connect Server (All versions \u003c V2.0). Affected products contain an open redirect vulnerability. An attacker could trick a valid authenticated user to the device into clicking a malicious link there by leading to phishing attacks.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en SINEMA Remote Connect Server (Todas las versiones anteriores a la versi\u00f3n V2.0). Los productos afectados contienen una vulnerabilidad de redirecci\u00f3n abierta. Un atacante podr\u00eda enga\u00f1ar a un usuario v\u00e1lido autentificado en el dispositivo para que haga clic en un enlace malicioso, lo que llevar\u00eda a ataques de phishing.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":2.8,\"impactScore\":2.7}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:N\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\",\"baseScore\":5.8},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":4.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-601\"}]},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-601\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinema_remote_connect_server:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.0\",\"matchCriteriaId\":\"380C606D-43A0-4362-9A5E-BC7320890196\"}]}]}],\"references\":[{\"url\":\"http://packetstormsecurity.com/files/165966/SIEMENS-SINEMA-Remote-Connect-1.0-SP3-HF1-Open-Redirection.html\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"http://seclists.org/fulldisclosure/2022/Feb/20\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-654775.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.