CVE-2022-41688 (GCVE-0-2022-41688)

Vulnerability from cvelistv5 – Published: 2022-10-31 19:38 – Updated: 2025-04-16 16:06
VLAI?
Summary
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lack proper authentication for functions that create and modify user groups. An attacker could provide malicious serialized objects that could run these functions without authentication to create a new user and add them to the administrator group.
CWE
  • CWE-306 - Missing Authentication for Critical Function
Assigner
References
Impacted products
Vendor Product Version
Delta Electronics InfraSuite Device Master Affected: 0 , ≤ 00.00.01a (custom)
Create a notification for this product.
Credits
kimiya Trend Micro Zero Day Initiative
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T12:49:43.574Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-07"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-41688",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T15:52:42.633485Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T16:06:36.155Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "InfraSuite Device Master",
          "vendor": "Delta Electronics",
          "versions": [
            {
              "lessThanOrEqual": "00.00.01a",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "kimiya"
        },
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Trend Micro Zero Day Initiative"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics InfraSuite Device Master versions 00.00.01a and prior lack proper authentication for functions that create and modify user groups. An attacker could provide malicious serialized objects that could run these functions without authentication to create a new user and add them to the administrator group.\u003c/span\u003e\n\n"
            }
          ],
          "value": "\nDelta Electronics InfraSuite Device Master versions 00.00.01a and prior lack proper authentication for functions that create and modify user groups. An attacker could provide malicious serialized objects that could run these functions without authentication to create a new user and add them to the administrator group.\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306 Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-10-31T19:38:21.943Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-07"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-41688",
    "datePublished": "2022-10-31T19:38:21.943Z",
    "dateReserved": "2022-09-29T14:09:27.480Z",
    "dateUpdated": "2025-04-16T16:06:36.155Z",
    "requesterUserId": "bc31a57b-b1a5-40e2-9263-67c0ae8a3b8a",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:deltaww:infrasuite_device_master:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"00.00.02a\", \"matchCriteriaId\": \"0BC08CDF-4EE4-4E6D-AFF0-A4749A91A05D\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"\\nDelta Electronics InfraSuite Device Master versions 00.00.01a and prior lack proper authentication for functions that create and modify user groups. An attacker could provide malicious serialized objects that could run these functions without authentication to create a new user and add them to the administrator group.\\n\\n\"}, {\"lang\": \"es\", \"value\": \"Las versiones 00.00.01a y anteriores de Delta Electronics InfraSuite Device Master carecen de autenticaci\\u00f3n adecuada para las funciones que crean y modifican grupos de usuarios. Un atacante podr\\u00eda proporcionar objetos serializados maliciosos que podr\\u00edan ejecutar estas funciones sin autenticaci\\u00f3n para crear un nuevo usuario y agregarlo al grupo de administradores.\\n\"}]",
      "id": "CVE-2022-41688",
      "lastModified": "2024-11-21T07:23:39.087",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"ics-cert@hq.dhs.gov\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 9.8, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.9}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.6}]}",
      "published": "2022-10-31T20:15:13.527",
      "references": "[{\"url\": \"https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-07\", \"source\": \"ics-cert@hq.dhs.gov\", \"tags\": [\"Patch\", \"Third Party Advisory\", \"US Government Resource\"]}, {\"url\": \"https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-07\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Patch\", \"Third Party Advisory\", \"US Government Resource\"]}]",
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"ics-cert@hq.dhs.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-306\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2022-41688\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2022-10-31T20:15:13.527\",\"lastModified\":\"2024-11-21T07:23:39.087\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"\\nDelta Electronics InfraSuite Device Master versions 00.00.01a and prior lack proper authentication for functions that create and modify user groups. An attacker could provide malicious serialized objects that could run these functions without authentication to create a new user and add them to the administrator group.\\n\\n\"},{\"lang\":\"es\",\"value\":\"Las versiones 00.00.01a y anteriores de Delta Electronics InfraSuite Device Master carecen de autenticaci\u00f3n adecuada para las funciones que crean y modifican grupos de usuarios. Un atacante podr\u00eda proporcionar objetos serializados maliciosos que podr\u00edan ejecutar estas funciones sin autenticaci\u00f3n para crear un nuevo usuario y agregarlo al grupo de administradores.\\n\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-306\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:deltaww:infrasuite_device_master:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"00.00.02a\",\"matchCriteriaId\":\"0BC08CDF-4EE4-4E6D-AFF0-A4749A91A05D\"}]}]}],\"references\":[{\"url\":\"https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-07\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Patch\",\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-07\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Third Party Advisory\",\"US Government Resource\"]}]}}",
    "vulnrichment": {
      "containers": "{\"cna\": {\"affected\": [{\"defaultStatus\": \"unaffected\", \"product\": \"InfraSuite Device Master\", \"vendor\": \"Delta Electronics\", \"versions\": [{\"lessThanOrEqual\": \"00.00.01a\", \"status\": \"affected\", \"version\": \"0\", \"versionType\": \"custom\"}]}], \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"user\": \"00000000-0000-4000-9000-000000000000\", \"value\": \"kimiya\"}, {\"lang\": \"en\", \"type\": \"reporter\", \"user\": \"00000000-0000-4000-9000-000000000000\", \"value\": \"Trend Micro Zero Day Initiative\"}], \"descriptions\": [{\"lang\": \"en\", \"supportingMedia\": [{\"base64\": false, \"type\": \"text/html\", \"value\": \"\\n\\n\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003eDelta Electronics InfraSuite Device Master versions 00.00.01a and prior lack proper authentication for functions that create and modify user groups. An attacker could provide malicious serialized objects that could run these functions without authentication to create a new user and add them to the administrator group.\u003c/span\u003e\\n\\n\"}], \"value\": \"\\nDelta Electronics InfraSuite Device Master versions 00.00.01a and prior lack proper authentication for functions that create and modify user groups. An attacker could provide malicious serialized objects that could run these functions without authentication to create a new user and add them to the administrator group.\\n\\n\"}], \"metrics\": [{\"cvssV3_1\": {\"attackComplexity\": \"LOW\", \"attackVector\": \"NETWORK\", \"availabilityImpact\": \"HIGH\", \"baseScore\": 9.8, \"baseSeverity\": \"CRITICAL\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"scope\": \"UNCHANGED\", \"userInteraction\": \"NONE\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"version\": \"3.1\"}, \"format\": \"CVSS\", \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"problemTypes\": [{\"descriptions\": [{\"cweId\": \"CWE-306\", \"description\": \"CWE-306 Missing Authentication for Critical Function\", \"lang\": \"en\", \"type\": \"CWE\"}]}], \"providerMetadata\": {\"orgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"shortName\": \"icscert\", \"dateUpdated\": \"2022-10-31T19:38:21.943Z\"}, \"references\": [{\"tags\": [\"government-resource\"], \"url\": \"https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-07\"}], \"source\": {\"discovery\": \"UNKNOWN\"}, \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}}, \"adp\": [{\"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-03T12:49:43.574Z\"}, \"title\": \"CVE Program Container\", \"references\": [{\"tags\": [\"government-resource\", \"x_transferred\"], \"url\": \"https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-07\"}]}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2022-41688\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-04-16T15:52:42.633485Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-04-16T15:52:44.864Z\"}}]}",
      "cveMetadata": "{\"cveId\": \"CVE-2022-41688\", \"assignerOrgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"state\": \"PUBLISHED\", \"assignerShortName\": \"icscert\", \"requesterUserId\": \"bc31a57b-b1a5-40e2-9263-67c0ae8a3b8a\", \"dateReserved\": \"2022-09-29T14:09:27.480Z\", \"datePublished\": \"2022-10-31T19:38:21.943Z\", \"dateUpdated\": \"2025-04-16T16:06:36.155Z\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…