CVE-2023-43087
Vulnerability from cvelistv5
Published
2023-11-02 10:30
Modified
2024-09-05 18:54
Severity ?
EPSS score ?
Summary
Dell PowerScale OneFS 8.2.x, 9.0.0.x-9.5.0.x contains an improper handling of insufficient permissions. A low privileged remote attacker could potentially exploit this vulnerability to cause information disclosure.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Dell | PowerScale OneFS |
Version: Version 9.2.1.0 through 9.2.1.23 |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T19:37:23.334Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://www.dell.com/support/kbdoc/en-us/000218934/powerscale-onefs-security-updates-for-multiple-security-vulnerabilities" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-43087", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-09-05T18:48:41.154519Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-09-05T18:54:12.369Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "PowerScale OneFS", "vendor": "Dell", "versions": [ { "status": "affected", "version": "Version 9.2.1.0 through 9.2.1.23" } ] } ], "datePublic": "2023-11-02T06:30:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell PowerScale OneFS 8.2.x, 9.0.0.x-9.5.0.x contains an improper handling of insufficient permissions. A low privileged remote attacker could potentially exploit this vulnerability to cause information disclosure.\u003c/span\u003e\n\n" } ], "value": "\nDell PowerScale OneFS 8.2.x, 9.0.0.x-9.5.0.x contains an improper handling of insufficient permissions. A low privileged remote attacker could potentially exploit this vulnerability to cause information disclosure.\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-280", "description": "CWE-280: Improper Handling of Insufficient Permissions or Privileges", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-11-02T10:30:31.343Z", "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "shortName": "dell" }, "references": [ { "tags": [ "vendor-advisory" ], "url": "https://www.dell.com/support/kbdoc/en-us/000218934/powerscale-onefs-security-updates-for-multiple-security-vulnerabilities" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "assignerShortName": "dell", "cveId": "CVE-2023-43087", "datePublished": "2023-11-02T10:30:31.343Z", "dateReserved": "2023-09-15T07:03:52.366Z", "dateUpdated": "2024-09-05T18:54:12.369Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2023-43087\",\"sourceIdentifier\":\"security_alert@emc.com\",\"published\":\"2023-11-02T11:15:14.460\",\"lastModified\":\"2023-11-09T19:15:15.187\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"\\nDell PowerScale OneFS 8.2.x, 9.0.0.x-9.5.0.x contains an improper handling of insufficient permissions. A low privileged remote attacker could potentially exploit this vulnerability to cause information disclosure.\\n\\n\"},{\"lang\":\"es\",\"value\":\"Dell PowerScale OneFS 8.2.x, 9.0.0.x-9.5.0.x contiene un manejo inadecuado de permisos insuficientes. Un atacante remoto con pocos privilegios podr\u00eda explotar esta vulnerabilidad para provocar la divulgaci\u00f3n de informaci\u00f3n.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":2.8,\"impactScore\":3.6},{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":4.3,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":2.8,\"impactScore\":1.4}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-755\"}]},{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-280\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:dell:powerscale_onefs:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"8.2.0\",\"versionEndIncluding\":\"8.2.2\",\"matchCriteriaId\":\"EEB90F51-C02F-47F4-A3DF-CA74BD64A48F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:dell:powerscale_onefs:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"9.2.1\",\"versionEndExcluding\":\"9.2.1.24\",\"matchCriteriaId\":\"EFCA09F1-AC1F-4664-BD44-84905EF67C21\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:dell:powerscale_onefs:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"9.4\",\"versionEndExcluding\":\"9.4.0.15\",\"matchCriteriaId\":\"B3DA3B74-39E0-49B9-91E7-CDA79C1B6A6F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:dell:powerscale_onefs:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"9.5\",\"versionEndExcluding\":\"9.5.0.6\",\"matchCriteriaId\":\"58030370-13DD-46EB-9EA9-4161ABE93255\"}]}]}],\"references\":[{\"url\":\"https://www.dell.com/support/kbdoc/en-us/000218934/powerscale-onefs-security-updates-for-multiple-security-vulnerabilities\",\"source\":\"security_alert@emc.com\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.