CVE-2023-49125
Vulnerability from cvelistv5
Published
2024-02-13 08:59
Modified
2024-08-02 21:46
Summary
A vulnerability has been identified in Parasolid V35.0 (All versions < V35.0.263), Parasolid V35.1 (All versions < V35.1.252), Parasolid V36.0 (All versions < V36.0.198), Solid Edge SE2023 (All versions < V223.0 Update 11), Solid Edge SE2024 (All versions < V224.0 Update 3). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted files containing XT format. This could allow an attacker to execute code in the context of the current process.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T21:46:29.325Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-797296.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-382651.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V35.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V35.0.263",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V35.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V35.1.252",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Parasolid V36.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V36.0.198",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Solid Edge SE2023",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V223.0 Update 11",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Solid Edge SE2024",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V224.0 Update 3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Parasolid V35.0 (All versions \u003c V35.0.263), Parasolid V35.1 (All versions \u003c V35.1.252), Parasolid V36.0 (All versions \u003c V36.0.198), Solid Edge SE2023 (All versions \u003c V223.0 Update 11), Solid Edge SE2024 (All versions \u003c V224.0 Update 3). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted files containing XT format. This could allow an attacker to execute code in the context of the current process."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-05-15T07:23:49.243Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-797296.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-382651.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-49125",
    "datePublished": "2024-02-13T08:59:57.813Z",
    "dateReserved": "2023-11-22T14:43:13.524Z",
    "dateUpdated": "2024-08-02T21:46:29.325Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2023-49125\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2024-02-13T09:15:46.173\",\"lastModified\":\"2024-10-18T17:24:19.157\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Parasolid V35.0 (All versions \u003c V35.0.263), Parasolid V35.1 (All versions \u003c V35.1.252), Parasolid V36.0 (All versions \u003c V36.0.198), Solid Edge SE2023 (All versions \u003c V223.0 Update 11), Solid Edge SE2024 (All versions \u003c V224.0 Update 3). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted files containing XT format. This could allow an attacker to execute code in the context of the current process.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en Parasolid V35.0 (Todas las versiones \u0026lt; V35.0.263), Parasolid V35.1 (Todas las versiones \u0026lt; V35.1.252), Parasolid V36.0 (Todas las versiones \u0026lt; V36.0.198). Las aplicaciones afectadas contienen una lectura fuera de los l\u00edmites m\u00e1s all\u00e1 del final de una estructura asignada mientras analizan archivos especialmente manipulados que contienen formato XT. Esto podr\u00eda permitir a un atacante ejecutar c\u00f3digo en el contexto del proceso actual.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-125\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"35.0\",\"versionEndExcluding\":\"35.0.263\",\"matchCriteriaId\":\"1E918719-9972-41B1-88FE-F37A1B73926C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"35.1\",\"versionEndExcluding\":\"35.1.252\",\"matchCriteriaId\":\"0A867E95-E661-42EA-8E58-973EBC559806\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"36.0\",\"versionEndExcluding\":\"36.0.198\",\"matchCriteriaId\":\"61E012B9-DD01-4F8C-B8EB-EBE5BD50EA82\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge_se2023:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"223.0\",\"matchCriteriaId\":\"6708C521-2523-4FFE-8D66-01386DF0FAAF\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0001:*:*:*:*:*:*\",\"matchCriteriaId\":\"619B13A0-ADF3-4CC9-A5BD-6C99AE369D43\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0002:*:*:*:*:*:*\",\"matchCriteriaId\":\"E4C4B3EA-853A-4C75-AA5F-319E2802A722\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0003:*:*:*:*:*:*\",\"matchCriteriaId\":\"28C04B66-7E6F-49E6-B7A9-E7357ADE5936\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0004:*:*:*:*:*:*\",\"matchCriteriaId\":\"99A72C67-00A3-499A-9DDC-73AD29672A08\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0005:*:*:*:*:*:*\",\"matchCriteriaId\":\"9C7B34D6-925F-4DB9-8418-962F35FE11C6\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0006:*:*:*:*:*:*\",\"matchCriteriaId\":\"211C7830-D4B9-4315-BDE8-F108FF6A609C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0007:*:*:*:*:*:*\",\"matchCriteriaId\":\"52647713-2F45-4D35-B31A-5BB2E15175EF\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0008:*:*:*:*:*:*\",\"matchCriteriaId\":\"4378378B-BAEA-4200-9336-936835322DF6\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0009:*:*:*:*:*:*\",\"matchCriteriaId\":\"57968030-2B5F-41C1-B8B4-2405C84E3A06\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge_se2023:223.0:update_0010:*:*:*:*:*:*\",\"matchCriteriaId\":\"BB884C55-636D-4DED-8865-CA83CC74FE05\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge_se2024:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"224.0\",\"matchCriteriaId\":\"D3887095-4E46-43B0-8A1E-4938EB474419\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0001:*:*:*:*:*:*\",\"matchCriteriaId\":\"829C4AEB-7C8D-408B-A79C-8684753F45E1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0002:*:*:*:*:*:*\",\"matchCriteriaId\":\"1E8FB23E-280D-46FD-BD44-5D4552639E00\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-382651.html\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-797296.html\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...
  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.