Summary
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
vulnerability exists that could cause arbitrary file deletion upon service restart when accessed by
a local and low-privileged attacker.
References
Impacted products
▼ | Vendor | Product |
---|---|---|
Schneider Electric | Easy UPS Online Monitoring Software |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T08:28:21.777Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-346-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-346-03.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Easy UPS Online Monitoring Software", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "2.6-GA-01-23116 and prior (Windows 10, 11, Windows Server 2016, 2019, 2022)" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\nA CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)\nvulnerability exists that could cause arbitrary file deletion upon service restart when accessed by\na local and low-privileged attacker.\n\n" } ], "value": "\nA CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)\nvulnerability exists that could cause arbitrary file deletion upon service restart when accessed by\na local and low-privileged attacker.\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:N/I:L/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-22", "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-12-14T05:02:30.242Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-346-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-346-03.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2023-6407", "datePublished": "2023-12-14T05:02:30.242Z", "dateReserved": "2023-11-30T09:44:49.961Z", "dateUpdated": "2024-08-02T08:28:21.777Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2023-6407\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2023-12-14T05:15:14.407\",\"lastModified\":\"2023-12-18T19:34:53.843\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"\\nA CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)\\nvulnerability exists that could cause arbitrary file deletion upon service restart when accessed by\\na local and low-privileged attacker.\\n\\n\"},{\"lang\":\"es\",\"value\":\"Existe una vulnerabilidad CWE-22: limitaci\u00f3n inadecuada de un nombre de ruta a un directorio restringido (\\\"Path Traversal\\\") que podr\u00eda causar la eliminaci\u00f3n arbitraria de archivos al reiniciar el servicio cuando un atacante local y con pocos privilegios accede a \u00e9l.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.1,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.2},{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:N/I:L/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"HIGH\",\"baseScore\":5.3,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":1.0,\"impactScore\":4.2}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-22\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_10_1507:-:*:*:*:*:*:x64:*\",\"matchCriteriaId\":\"A045AC0A-471E-444C-B3B0-4CABC23E8CFB\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_10_1507:-:*:*:*:*:*:x86:*\",\"matchCriteriaId\":\"28A7FEE9-B473-48A0-B0ED-A5CC1E44194C\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_11_21h2:-:*:*:*:*:*:arm64:*\",\"matchCriteriaId\":\"F2D718BD-C4B7-48DB-BE78-B9CA22F27DD0\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_11_21h2:-:*:*:*:*:*:x64:*\",\"matchCriteriaId\":\"0C3552E0-F793-4CDD-965D-457495475805\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_server_2016:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"041FF8BA-0B12-4A1F-B4BF-9C4F33B7C1E7\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_server_2019:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DB79EE26-FC32-417D-A49C-A1A63165A968\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_server_2022:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"821614DD-37DD-44E2-A8A4-FE8D23A33C3C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:easy_ups_online_monitoring_software:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.6-ga-01-23248\",\"matchCriteriaId\":\"717BACD7-C79C-4CC1-B003-6377C26386D7\"}]}]}],\"references\":[{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-346-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-346-03.pdf\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.