CVE-2024-12194
Vulnerability from cvelistv5
Published
2024-12-17 15:20
Modified
2024-12-17 16:00
Summary
A maliciously crafted DWFX file, when parsed through Autodesk Navisworks, can force a Memory Corruption vulnerability. A malicious actor can leverage this vulnerability to execute arbitrary code in the context of the current process.
Impacted products
Vendor Product Version
Autodesk Navisworks Simulate Version: 2025
Autodesk Navisworks Manage Version: 2025
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-12194",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-12-17T16:00:36.826047Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-12-17T16:00:47.336Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Windows"
          ],
          "product": "Navisworks Freedom",
          "vendor": "Autodesk",
          "versions": [
            {
              "status": "affected",
              "version": "2025"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Windows"
          ],
          "product": "Navisworks Simulate",
          "vendor": "Autodesk",
          "versions": [
            {
              "status": "affected",
              "version": "2025"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Windows"
          ],
          "product": "Navisworks Manage",
          "vendor": "Autodesk",
          "versions": [
            {
              "status": "affected",
              "version": "2025"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u003cspan style=\"background-color: rgb(248, 248, 248);\"\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA maliciously crafted DWFX file, when parsed through Autodesk Navisworks, can force \u003c/span\u003ea Memory Corruption vulnerability\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e. A malicious actor can leverage this vulnerability to execute arbitrary code in the context of the current process.\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e\u003c/span\u003e\u003cbr\u003e"
            }
          ],
          "value": "A maliciously crafted DWFX file, when parsed through Autodesk Navisworks, can force a Memory Corruption vulnerability. A malicious actor can leverage this vulnerability to execute arbitrary code in the context of the current process."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-100",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-100 Overflow Buffers"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-12-17T15:20:17.674Z",
        "orgId": "7e40ea87-bc65-4944-9723-dd79dd760601",
        "shortName": "autodesk"
      },
      "references": [
        {
          "url": "https://autodesk.com/trust/security-advisories/adsk-sa-2024-0027"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "DWFX File Parsing Vulnerabilities in Autodesk Navisworks Desktop Software",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7e40ea87-bc65-4944-9723-dd79dd760601",
    "assignerShortName": "autodesk",
    "cveId": "CVE-2024-12194",
    "datePublished": "2024-12-17T15:20:17.674Z",
    "dateReserved": "2024-12-04T17:03:52.996Z",
    "dateUpdated": "2024-12-17T16:00:47.336Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-12194\",\"sourceIdentifier\":\"psirt@autodesk.com\",\"published\":\"2024-12-17T16:15:24.370\",\"lastModified\":\"2024-12-17T16:15:24.370\",\"vulnStatus\":\"Received\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A maliciously crafted DWFX file, when parsed through Autodesk Navisworks, can force a Memory Corruption vulnerability. A malicious actor can leverage this vulnerability to execute arbitrary code in the context of the current process.\"},{\"lang\":\"es\",\"value\":\"Un archivo DWFX manipulado con fines malintencionados, al analizarse mediante Autodesk Navisworks, puede provocar una vulnerabilidad de corrupci\u00f3n de memoria. Un actor malintencionado puede aprovechar esta vulnerabilidad para ejecutar c\u00f3digo arbitrario en el contexto del proceso actual.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"psirt@autodesk.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"psirt@autodesk.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-120\"}]}],\"references\":[{\"url\":\"https://autodesk.com/trust/security-advisories/adsk-sa-2024-0027\",\"source\":\"psirt@autodesk.com\"}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.