CVE-2024-2097 (GCVE-0-2024-2097)
Vulnerability from cvelistv5 – Published: 2024-03-27 02:26 – Updated: 2025-10-21 14:15
VLAI?
Summary
An authenticated malicious client can send a special LINQ query
to execute arbitrary code remotely (RCE) on the SCM server
from List control, and execute the arbitrary code on the same
system where SCMArchivedEventViewerTool is installed in the
case of SCM Tools.
Severity ?
CWE
- CWE-94 - Improper Control of Generation of Code ('Code Injection')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Hitachi Energy | MACH SCM Server |
Affected:
4.0 , ≤ 4.38.3
(custom)
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T19:03:38.825Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000189\u0026languageCode=en\u0026Preview=true"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:hitachienergy:modular_advanced_control_for_hvdc:4.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "modular_advanced_control_for_hvdc",
"vendor": "hitachienergy",
"versions": [
{
"lessThanOrEqual": "4.38",
"status": "affected",
"version": "4.0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-2097",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-02T15:47:19.350980Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-94",
"description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-21T14:15:32.191Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "MACH SCM Server",
"vendor": "Hitachi Energy",
"versions": [
{
"lessThanOrEqual": "4.38.3",
"status": "affected",
"version": "4.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MACH SCM Tools",
"vendor": "Hitachi Energy",
"versions": [
{
"lessThanOrEqual": "1.8",
"status": "affected",
"version": "1.0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An authenticated malicious client can send a special LINQ query\nto execute arbitrary code remotely (RCE) on the SCM server\nfrom List control, and execute the arbitrary code on the same\nsystem where SCMArchivedEventViewerTool is installed in the\ncase of SCM Tools."
}
],
"value": "An authenticated malicious client can send a special LINQ query\nto execute arbitrary code remotely (RCE) on the SCM server\nfrom List control, and execute the arbitrary code on the same\nsystem where SCMArchivedEventViewerTool is installed in the\ncase of SCM Tools."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "MACH SCM Server"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "MACH SCM Tools"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-16T08:03:51.973Z",
"orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"shortName": "Hitachi Energy"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000189\u0026languageCode=en\u0026Preview=true"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"assignerShortName": "Hitachi Energy",
"cveId": "CVE-2024-2097",
"datePublished": "2024-03-27T02:26:17.338Z",
"dateReserved": "2024-03-01T15:56:00.646Z",
"dateUpdated": "2025-10-21T14:15:32.191Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"descriptions": "[{\"lang\": \"en\", \"value\": \"Authenticated List control client can execute the LINQ query in SCM Server to present event as list for operator. An authenticated malicious client can send special LINQ query to execute arbitrary code remotely (RCE) on the SCM Server that an attacker otherwise does not have authorization to do.\"}, {\"lang\": \"es\", \"value\": \"El cliente de control de lista autenticado puede ejecutar la consulta LINQ en el servidor SCM para presentar el evento como una lista para el operador. Un cliente malicioso autenticado puede enviar una consulta LINQ especial para ejecutar c\\u00f3digo arbitrario de forma remota (RCE) en el servidor SCM para lo cual, de otro modo, un atacante no tendr\\u00eda autorizaci\\u00f3n.\"}]",
"id": "CVE-2024-2097",
"lastModified": "2024-11-21T09:09:01.930",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"cybersecurity@hitachienergy.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"HIGH\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.6, \"impactScore\": 5.9}]}",
"published": "2024-03-27T03:15:12.290",
"references": "[{\"url\": \"https://publisher.hitachienergy.com/preview?DocumentId=8DBD000189\u0026languageCode=en\u0026Preview=true\", \"source\": \"cybersecurity@hitachienergy.com\"}, {\"url\": \"https://publisher.hitachienergy.com/preview?DocumentId=8DBD000189\u0026languageCode=en\u0026Preview=true\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}]",
"sourceIdentifier": "cybersecurity@hitachienergy.com",
"vulnStatus": "Awaiting Analysis",
"weaknesses": "[{\"source\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-94\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2024-2097\",\"sourceIdentifier\":\"cybersecurity@hitachienergy.com\",\"published\":\"2024-03-27T03:15:12.290\",\"lastModified\":\"2025-09-30T13:15:47.543\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An authenticated malicious client can send a special LINQ query\\nto execute arbitrary code remotely (RCE) on the SCM server\\nfrom List control, and execute the arbitrary code on the same\\nsystem where SCMArchivedEventViewerTool is installed in the\\ncase of SCM Tools.\"},{\"lang\":\"es\",\"value\":\"El cliente de control de lista autenticado puede ejecutar la consulta LINQ en el servidor SCM para presentar el evento como una lista para el operador. Un cliente malicioso autenticado puede enviar una consulta LINQ especial para ejecutar c\u00f3digo arbitrario de forma remota (RCE) en el servidor SCM para lo cual, de otro modo, un atacante no tendr\u00eda autorizaci\u00f3n.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cybersecurity@hitachienergy.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.6,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-94\"}]}],\"references\":[{\"url\":\"https://publisher.hitachienergy.com/preview?DocumentId=8DBD000189\u0026languageCode=en\u0026Preview=true\",\"source\":\"cybersecurity@hitachienergy.com\"},{\"url\":\"https://publisher.hitachienergy.com/preview?DocumentId=8DBD000189\u0026languageCode=en\u0026Preview=true\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://publisher.hitachienergy.com/preview?DocumentId=8DBD000189\u0026languageCode=en\u0026Preview=true\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-01T19:03:38.825Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-2097\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-08-02T15:47:19.350980Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:a:hitachienergy:modular_advanced_control_for_hvdc:4.0:*:*:*:*:*:*:*\"], \"vendor\": \"hitachienergy\", \"product\": \"modular_advanced_control_for_hvdc\", \"versions\": [{\"status\": \"affected\", \"version\": \"4.0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"4.38\"}], \"defaultStatus\": \"unaffected\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-94\", \"description\": \"CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-08-02T15:49:33.366Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.5, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"HIGH\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"MACH SCM Server\"}]}, {\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"HIGH\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"MACH SCM Tools\"}]}], \"affected\": [{\"vendor\": \"Hitachi Energy\", \"product\": \"MACH SCM Server\", \"versions\": [{\"status\": \"affected\", \"version\": \"4.0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"4.38.3\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Hitachi Energy\", \"product\": \"MACH SCM Tools\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"1.8\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://publisher.hitachienergy.com/preview?DocumentId=8DBD000189\u0026languageCode=en\u0026Preview=true\", \"tags\": [\"vendor-advisory\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"An authenticated malicious client can send a special LINQ query\\nto execute arbitrary code remotely (RCE) on the SCM server\\nfrom List control, and execute the arbitrary code on the same\\nsystem where SCMArchivedEventViewerTool is installed in the\\ncase of SCM Tools.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"An authenticated malicious client can send a special LINQ query\\nto execute arbitrary code remotely (RCE) on the SCM server\\nfrom List control, and execute the arbitrary code on the same\\nsystem where SCMArchivedEventViewerTool is installed in the\\ncase of SCM Tools.\", \"base64\": false}]}], \"providerMetadata\": {\"orgId\": \"e383dce4-0c27-4495-91c4-0db157728d17\", \"shortName\": \"Hitachi Energy\", \"dateUpdated\": \"2025-10-16T08:03:51.973Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2024-2097\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-10-21T14:15:32.191Z\", \"dateReserved\": \"2024-03-01T15:56:00.646Z\", \"assignerOrgId\": \"e383dce4-0c27-4495-91c4-0db157728d17\", \"datePublished\": \"2024-03-27T02:26:17.338Z\", \"assignerShortName\": \"Hitachi Energy\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…