CVE-2024-2425
Vulnerability from cvelistv5
Published
2024-03-25 20:14
Modified
2024-08-01 19:11
Severity ?
EPSS score ?
Summary
Rockwell Automation - Denial-of-service and Input Validation Vulnerabilities in PowerFlex® 527
References
Impacted products
▼ | Vendor | Product |
---|---|---|
Rockwell Automation | PowerFlex® 527 |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-2425", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-03-28T18:27:55.373294Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-04T17:30:25.436Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T19:11:53.614Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://https://www.rockwellautomation.com/en-us/support/advisory.SD1664.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "PowerFlex\u00ae 527", "vendor": "Rockwell Automation ", "versions": [ { "status": "affected", "version": " v2.001.x \u003c" } ] } ], "datePublic": "2024-03-21T13:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA denial-of-service vulnerability exists in the Rockwell Automation PowerFlex\u00ae 527 due to improper input validation in the device. If exploited, the web server will crash and need a manual restart to recover it.\u003c/span\u003e\n\n" } ], "value": "\nA denial-of-service vulnerability exists in the Rockwell Automation PowerFlex\u00ae 527 due to improper input validation in the device. If exploited, the web server will crash and need a manual restart to recover it.\n\n" } ], "impacts": [ { "capecId": "CAPEC-153", "descriptions": [ { "lang": "en", "value": "CAPEC-153 Input Data Manipulation" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-20", "description": "CWE-20 Improper Input Validation", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-25T20:18:14.816Z", "orgId": "b73dd486-f505-4403-b634-40b078b177f0", "shortName": "Rockwell" }, "references": [ { "url": "https://https://www.rockwellautomation.com/en-us/support/advisory.SD1664.html" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cp\u003eThere is no fix currently for this vulnerability. Users using the affected software are encouraged to apply risk mitigations and security best practices, where possible.\u003c/p\u003e\u003cul\u003e\u003cli\u003eImplement network segmentation confirming the device is on an isolated network.\u003c/li\u003e\u003cli\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://literature.rockwellautomation.com/idc/groups/literature/documents/um/520-um002_-en-e.pdf\"\u003eDisable the web server\u003c/a\u003e, if not needed. The web server is disabled by default. Disabling this feature is available in v2.001.x and later.\u003c/li\u003e\u003cli\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\"\u003eSecurity Best Practices\u003c/a\u003e\u003c/li\u003e\u003c/ul\u003e" } ], "value": "\nThere is no fix currently for this vulnerability. Users using the affected software are encouraged to apply risk mitigations and security best practices, where possible.\n\n * Implement network segmentation confirming the device is on an isolated network.\n * Disable the web server https://literature.rockwellautomation.com/idc/groups/literature/documents/um/520-um002_-en-e.pdf , if not needed. The web server is disabled by default. Disabling this feature is available in v2.001.x and later.\n * Security Best Practices https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight \n\n" } ], "source": { "discovery": "INTERNAL" }, "title": "Rockwell Automation - Denial-of-service and Input Validation Vulnerabilities in PowerFlex\u00ae 527", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0", "assignerShortName": "Rockwell", "cveId": "CVE-2024-2425", "datePublished": "2024-03-25T20:14:01.767Z", "dateReserved": "2024-03-13T14:45:09.065Z", "dateUpdated": "2024-08-01T19:11:53.614Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2024-2425\",\"sourceIdentifier\":\"PSIRT@rockwellautomation.com\",\"published\":\"2024-03-25T21:15:47.273\",\"lastModified\":\"2024-03-26T12:55:05.010\",\"vulnStatus\":\"Awaiting Analysis\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"\\nA denial-of-service vulnerability exists in the Rockwell Automation PowerFlex\u00ae 527 due to improper input validation in the device. If exploited, the web server will crash and need a manual restart to recover it.\\n\\n\"},{\"lang\":\"es\",\"value\":\"Existe una vulnerabilidad de denegaci\u00f3n de servicio en Rockwell Automation PowerFlex\u00ae 527 debido a una validaci\u00f3n de entrada incorrecta en el dispositivo. Si se explota, el servidor web fallar\u00e1 y ser\u00e1 necesario reiniciarlo manualmente para recuperarlo.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"PSIRT@rockwellautomation.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"PSIRT@rockwellautomation.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-20\"}]}],\"references\":[{\"url\":\"https://https://www.rockwellautomation.com/en-us/support/advisory.SD1664.html\",\"source\":\"PSIRT@rockwellautomation.com\"}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.