Summary
Dell PowerScale OneFS versions 8.2.2.x through 9.7.0.x contains a cleartext transmission of sensitive information vulnerability. A local low privileged attacker could potentially exploit this vulnerability, leading to escalation of privileges.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Dell | PowerScale OneFS |
Version: 8.2.2 ≤ 9.3.0.0 Version: 9.4.0.0 ≤ 9.4.0.16 Version: 9.5.0.0 ≤ 9.5.0.7 Version: 9.6.1.0 ≤ 9.7.0.1 |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-01T23:52:06.352Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://www.dell.com/support/kbdoc/en-us/000223366/dsa-2024-115-security-update-for-dell-powerscale-onefs-for-multiple-security-vulnerabilities" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:o:dell:powerscale_onefs:*:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "powerscale_onefs", "vendor": "dell", "versions": [ { "lessThanOrEqual": "9.3.0.0", "status": "affected", "version": "8.2.2", "versionType": "semver" }, { "lessThanOrEqual": "9.4.0.16", "status": "affected", "version": "9.4.0.0", "versionType": "semver" }, { "lessThanOrEqual": "9.5.0.7", "status": "affected", "version": "9.5.0.0", "versionType": "semver" }, { "lessThanOrEqual": "9.7.0.1", "status": "affected", "version": "9.6.1.0", "versionType": "semver" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-25960", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-08-12T20:12:52.564587Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-12T20:17:22.524Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "PowerScale OneFS", "vendor": "Dell", "versions": [ { "lessThanOrEqual": "9.3.0.0", "status": "affected", "version": "8.2.2", "versionType": "semver" }, { "lessThanOrEqual": "9.4.0.16", "status": "affected", "version": "9.4.0.0", "versionType": "semver" }, { "lessThanOrEqual": "9.5.0.7", "status": "affected", "version": "9.5.0.0", "versionType": "semver" }, { "lessThanOrEqual": "9.7.0.1", "status": "affected", "version": "9.6.1.0", "versionType": "semver" } ] } ], "datePublic": "2024-03-28T06:30:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Dell PowerScale OneFS versions 8.2.2.x through 9.7.0.x contains a cleartext transmission of sensitive information vulnerability. A local low privileged attacker could potentially exploit this vulnerability, leading to escalation of privileges." } ], "value": "Dell PowerScale OneFS versions 8.2.2.x through 9.7.0.x contains a cleartext transmission of sensitive information vulnerability. A local low privileged attacker could potentially exploit this vulnerability, leading to escalation of privileges." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.3, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-319", "description": "CWE-319: Cleartext Transmission of Sensitive Information", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-28T18:13:30.210Z", "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "shortName": "dell" }, "references": [ { "tags": [ "vendor-advisory" ], "url": "https://www.dell.com/support/kbdoc/en-us/000223366/dsa-2024-115-security-update-for-dell-powerscale-onefs-for-multiple-security-vulnerabilities" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "assignerShortName": "dell", "cveId": "CVE-2024-25960", "datePublished": "2024-03-28T18:13:30.210Z", "dateReserved": "2024-02-13T05:32:19.480Z", "dateUpdated": "2024-08-12T20:17:22.524Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2024-25960\",\"sourceIdentifier\":\"security_alert@emc.com\",\"published\":\"2024-03-28T19:15:47.970\",\"lastModified\":\"2024-03-28T20:53:20.813\",\"vulnStatus\":\"Awaiting Analysis\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"Dell PowerScale OneFS versions 8.2.2.x through 9.7.0.x contains a cleartext transmission of sensitive information vulnerability. A local low privileged attacker could potentially exploit this vulnerability, leading to escalation of privileges.\"},{\"lang\":\"es\",\"value\":\"Dell PowerScale OneFS versiones 8.2.2.x a 9.7.0.x contiene una vulnerabilidad de transmisi\u00f3n de texto plano de informaci\u00f3n confidencial. Un atacante local con pocos privilegios podr\u00eda explotar esta vulnerabilidad, lo que provocar\u00eda una escalada de privilegios.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.3,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.3,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-319\"}]}],\"references\":[{\"url\":\"https://www.dell.com/support/kbdoc/en-us/000223366/dsa-2024-115-security-update-for-dell-powerscale-onefs-for-multiple-security-vulnerabilities\",\"source\":\"security_alert@emc.com\"}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.