CVE-2024-4079
Vulnerability from cvelistv5
Published
2024-07-23 13:19
Modified
2024-08-01 20:33
Summary
Out of Bounds Read Due to Missing Bounds Check in LabVIEW
Impacted products
NILabVIEW
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:ni:labview:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "labview",
            "vendor": "ni",
            "versions": [
              {
                "lessThanOrEqual": "24.1",
                "status": "affected",
                "version": "0",
                "versionType": "semver"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4079",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-23T14:10:10.492631Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-23T14:12:00.156Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:33:51.641Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/out-of-bounds-read-due-to-missing-bounds-check-in-labview.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "LabVIEW",
          "vendor": "NI",
          "versions": [
            {
              "lessThanOrEqual": "24.1",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Michael Heinzl working with CISA"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAn out of bounds read due to a missing bounds check in LabVIEW may disclose information or result in arbitrary code execution.  Successful exploitation requires an attacker to provide a user with a specially crafted VI.  This vulnerability affects LabVIEW 2024 Q1 and prior versions.\u003c/span\u003e\u003cbr\u003e"
            }
          ],
          "value": "An out of bounds read due to a missing bounds check in LabVIEW may disclose information or result in arbitrary code execution.  Successful exploitation requires an attacker to provide a user with a specially crafted VI.  This vulnerability affects LabVIEW 2024 Q1 and prior versions."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-100",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-100 Overflow Buffers"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125 Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-23T13:19:35.141Z",
        "orgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
        "shortName": "NI"
      },
      "references": [
        {
          "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/out-of-bounds-read-due-to-missing-bounds-check-in-labview.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Out of Bounds Read Due to Missing Bounds Check in LabVIEW",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
    "assignerShortName": "NI",
    "cveId": "CVE-2024-4079",
    "datePublished": "2024-07-23T13:19:35.141Z",
    "dateReserved": "2024-04-23T15:11:16.465Z",
    "dateUpdated": "2024-08-01T20:33:51.641Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-4079\",\"sourceIdentifier\":\"security@ni.com\",\"published\":\"2024-07-23T14:15:14.353\",\"lastModified\":\"2024-09-05T17:12:19.830\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An out of bounds read due to a missing bounds check in LabVIEW may disclose information or result in arbitrary code execution.  Successful exploitation requires an attacker to provide a user with a specially crafted VI.  This vulnerability affects LabVIEW 2024 Q1 and prior versions.\"},{\"lang\":\"es\",\"value\":\"Una lectura fuera de los l\u00edmites debido a una verificaci\u00f3n de l\u00edmites faltantes en LabVIEW puede revelar informaci\u00f3n o resultar en la ejecuci\u00f3n de c\u00f3digo arbitrario. La explotaci\u00f3n exitosa requiere que un atacante proporcione al usuario un VI especialmente manipulado. Esta vulnerabilidad afecta a LabVIEW 2024 Q1 y versiones anteriores.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9},{\"source\":\"security@ni.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-125\"}]},{\"source\":\"security@ni.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-125\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ni:labview:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2020\",\"matchCriteriaId\":\"E9BBCA76-7B4C-4CC5-A782-489CA4223C04\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ni:labview:2021:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"9F184512-5D11-47F4-8555-EA6FF93C106F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ni:labview:2021:sp1:*:*:*:*:*:*\",\"matchCriteriaId\":\"BF28259A-30A6-4BB1-B262-A006AB74AFFA\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ni:labview:2022:q1:*:*:*:*:*:*\",\"matchCriteriaId\":\"4D12D6CF-802F-47BA-ADF9-9E52C071BD7F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ni:labview:2022:q3:*:*:*:*:*:*\",\"matchCriteriaId\":\"340F61E5-D1ED-4C29-A894-8BC5C5B90ACE\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ni:labview:2023:q1:*:*:*:*:*:*\",\"matchCriteriaId\":\"D7DD2022-CFB7-4F38-B459-C1AFB55B5B68\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ni:labview:2023:q3:*:*:*:*:*:*\",\"matchCriteriaId\":\"18AB0B07-72FE-4861-B69D-AD2E87C5382E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ni:labview:2023:q3_patch2:*:*:*:*:*:*\",\"matchCriteriaId\":\"044C4B51-C641-41F2-ACA0-834C99D63285\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ni:labview:2024:q1:*:*:*:*:*:*\",\"matchCriteriaId\":\"7753CCDF-BAF8-4F91-B85B-EBB2B88F6F30\"}]}]}],\"references\":[{\"url\":\"https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/out-of-bounds-read-due-to-missing-bounds-check-in-labview.html\",\"source\":\"security@ni.com\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.