CVE-2026-53483 (GCVE-0-2026-53483)
Vulnerability from cvelistv5 – Published: 2026-07-07 12:57 – Updated: 2026-07-08 03:56- CWE-287 - Improper Authentication
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00048126… | vendor-advisory |
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Dell | PowerProtect Data Domain |
Affected:
0 , < 8.8.0.0 or later
(semver)
Affected: 0 , < 8.6.1.20 or later (semver) Affected: 0 , < 8.3.1.40 or later (semver) Affected: 0 , < 7.13.1.80 or later (semver) |
guessed |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-53483",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-07T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-08T03:56:40.966Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect Data Domain",
"vendor": "Dell",
"versions": [
{
"lessThan": "8.8.0.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.6.1.20 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.3.1.40 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "7.13.1.80 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "other",
"value": "Dell would like to thank Ahmed Y. Elmogy for reporting these issues."
}
],
"datePublic": "2026-07-02T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 an improper authentication vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to unauthorized access. This is a critical severity vulnerability as it allows an attacker to take complete control of system; so Dell recommends customers to upgrade at the earliest opportunity."
}
],
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 an improper authentication vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to unauthorized access. This is a critical severity vulnerability as it allows an attacker to take complete control of system; so Dell recommends customers to upgrade at the earliest opportunity."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287: Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-07T12:57:07.708Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-53483",
"datePublished": "2026-07-07T12:57:07.708Z",
"dateReserved": "2026-06-09T17:04:35.250Z",
"dateUpdated": "2026-07-08T03:56:40.966Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2026-53483",
"date": "2026-10-30",
"epss": "0.00625",
"percentile": "0.49961"
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect Data Domain",
"vendor": "Dell",
"versions": [
{
"lessThan": "8.8.0.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.6.1.20 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.3.1.40 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "7.13.1.80 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"source": "security_alert@emc.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "064F56BA-B974-4133-9DFA-B13D503766AC",
"versionEndExcluding": "7.13.1.80",
"versionStartIncluding": "7.7.1.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EB4BB568-B169-4202-94E0-8D808419241B",
"versionEndExcluding": "8.3.1.40",
"versionStartIncluding": "7.14.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BA61361F-FED8-4936-A9F6-FFA35BE413F8",
"versionEndExcluding": "8.6.1.20",
"versionStartIncluding": "8.4.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "4BA45B0F-6A67-476D-9101-0DDC91B77D51",
"versionEndExcluding": "8.8.0.0",
"versionStartIncluding": "8.7.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 an improper authentication vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to unauthorized access. This is a critical severity vulnerability as it allows an attacker to take complete control of system; so Dell recommends customers to upgrade at the earliest opportunity."
},
{
"lang": "es",
"value": "Dell PowerProtect Data Domain, versiones 7.7.1.0 hasta 8.7, versi\u00f3n de lanzamiento LTS2026 8.6.1.0 hasta 8.6.1.10, versi\u00f3n de lanzamiento LTS2025 8.3.1.0 hasta 8.3.1.30, versiones de lanzamiento LTS2024 7.13.1.0 hasta 7.13.1.70 una vulnerabilidad de autenticaci\u00f3n impropia. Un atacante no autenticado con acceso remoto podr\u00eda potencialmente explotar esta vulnerabilidad, lo que llevar\u00eda a un acceso no autorizado. Esta es una vulnerabilidad de gravedad cr\u00edtica ya que permite a un atacante tomar el control completo del sistema; por lo que Dell recomienda a los clientes actualizar a la primera oportunidad."
}
],
"id": "CVE-2026-53483",
"lastModified": "2026-10-25T20:10:00.147",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "security_alert@emc.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2026-53483",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-07T00:00:00+00:00",
"version": "2.0.3"
}
}
]
},
"published": "2026-07-07T13:16:31.590",
"references": [
{
"source": "security_alert@emc.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities"
}
],
"sourceIdentifier": "security_alert@emc.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-287"
}
],
"source": "security_alert@emc.com",
"type": "Secondary"
}
]
}
},
"vulnrichment": {
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-53483",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-07T13:40:19.105432Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-07T13:40:22.378Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect Data Domain",
"vendor": "Dell",
"versions": [
{
"lessThan": "8.8.0.0 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.6.1.20 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "8.3.1.40 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "7.13.1.80 or later",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "other",
"value": "Dell would like to thank Ahmed Y. Elmogy for reporting these issues."
}
],
"datePublic": "2026-07-02T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 an improper authentication vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to unauthorized access. This is a critical severity vulnerability as it allows an attacker to take complete control of system; so Dell recommends customers to upgrade at the earliest opportunity."
}
],
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.7, LTS2026 release version 8.6.1.0 through 8.6.1.10, LTS2025 release version 8.3.1.0 through 8.3.1.30, LTS2024 release versions 7.13.1.0 through 7.13.1.70 an improper authentication vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to unauthorized access. This is a critical severity vulnerability as it allows an attacker to take complete control of system; so Dell recommends customers to upgrade at the earliest opportunity."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287: Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-07T12:57:07.708Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000481268/dsa-2026-278-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2026-53483",
"datePublished": "2026-07-07T12:57:07.708Z",
"dateReserved": "2026-06-09T17:04:35.250Z",
"dateUpdated": "2026-07-08T03:56:40.966Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.