Action not permitted
Modal body text goes here.
Modal Title
Modal Body
BDU:2023-07440
Vulnerability from fstec - Published: 14.02.2023
VLAI Severity ?
Title
Уязвимость набора инструментов для проектирования и моделирования Siemens Solid Edge, связанная с чтением за границами памяти, позволяющая нарушителю выполнить произвольный код
Description
Уязвимость набора инструментов для проектирования и моделирования Siemens Solid Edge связана с чтением за границами памяти. Эксплуатация уязвимости может позволить нарушителю выполнить произвольный код с помощью специально созданных PAR-файлов
Severity ?
Vendor
Siemens AG
Software Name
Solid Edge SE2022
Software Version
до 222.0 MP12 (Solid Edge SE2022)
Possible Mitigations
Использование рекомендаций:
https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf
Reference
https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf
https://vuldb.com/ru/?id.220884
CWE
CWE-125
{
"CVSS 2.0": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"CVSS 3.0": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"CVSS 4.0": null,
"remediation_\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": null,
"remediation_\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435": null,
"\u0412\u0435\u043d\u0434\u043e\u0440 \u041f\u041e": "Siemens AG",
"\u0412\u0435\u0440\u0441\u0438\u044f \u041f\u041e": "\u0434\u043e 222.0 MP12 (Solid Edge SE2022)",
"\u0412\u043e\u0437\u043c\u043e\u0436\u043d\u044b\u0435 \u043c\u0435\u0440\u044b \u043f\u043e \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044e": "\u0418\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u0440\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0430\u0446\u0438\u0439:\nhttps://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf",
"\u0414\u0430\u0442\u0430 \u0432\u044b\u044f\u0432\u043b\u0435\u043d\u0438\u044f": "14.02.2023",
"\u0414\u0430\u0442\u0430 \u043f\u043e\u0441\u043b\u0435\u0434\u043d\u0435\u0433\u043e \u043e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u044f": "02.11.2023",
"\u0414\u0430\u0442\u0430 \u043f\u0443\u0431\u043b\u0438\u043a\u0430\u0446\u0438\u0438": "02.11.2023",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": "BDU:2023-07440",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440\u044b \u0434\u0440\u0443\u0433\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c \u043e\u043f\u0438\u0441\u0430\u043d\u0438\u0439 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "CVE-2023-24558, SSA-491245",
"\u0418\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f \u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0430",
"\u041a\u043b\u0430\u0441\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043a\u043e\u0434\u0430",
"\u041d\u0430\u0437\u0432\u0430\u043d\u0438\u0435 \u041f\u041e": "Solid Edge SE2022",
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u041e\u0421 \u0438 \u0442\u0438\u043f \u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u043e\u0439 \u043f\u043b\u0430\u0442\u0444\u043e\u0440\u043c\u044b": null,
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043d\u0430\u0431\u043e\u0440\u0430 \u0438\u043d\u0441\u0442\u0440\u0443\u043c\u0435\u043d\u0442\u043e\u0432 \u0434\u043b\u044f \u043f\u0440\u043e\u0435\u043a\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f \u0438 \u043c\u043e\u0434\u0435\u043b\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f Siemens Solid Edge, \u0441\u0432\u044f\u0437\u0430\u043d\u043d\u0430\u044f \u0441 \u0447\u0442\u0435\u043d\u0438\u0435\u043c \u0437\u0430 \u0433\u0440\u0430\u043d\u0438\u0446\u0430\u043c\u0438 \u043f\u0430\u043c\u044f\u0442\u0438, \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044e\u0449\u0430\u044f \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e \u0432\u044b\u043f\u043e\u043b\u043d\u0438\u0442\u044c \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u043b\u044c\u043d\u044b\u0439 \u043a\u043e\u0434",
"\u041d\u0430\u043b\u0438\u0447\u0438\u0435 \u044d\u043a\u0441\u043f\u043b\u043e\u0439\u0442\u0430": "\u0414\u0430\u043d\u043d\u044b\u0435 \u0443\u0442\u043e\u0447\u043d\u044f\u044e\u0442\u0441\u044f",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "\u0427\u0442\u0435\u043d\u0438\u0435 \u0437\u0430 \u0433\u0440\u0430\u043d\u0438\u0446\u0430\u043c\u0438 \u0431\u0443\u0444\u0435\u0440\u0430 (CWE-125)",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043d\u0430\u0431\u043e\u0440\u0430 \u0438\u043d\u0441\u0442\u0440\u0443\u043c\u0435\u043d\u0442\u043e\u0432 \u0434\u043b\u044f \u043f\u0440\u043e\u0435\u043a\u0442\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f \u0438 \u043c\u043e\u0434\u0435\u043b\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u044f Siemens Solid Edge \u0441\u0432\u044f\u0437\u0430\u043d\u0430 \u0441 \u0447\u0442\u0435\u043d\u0438\u0435\u043c \u0437\u0430 \u0433\u0440\u0430\u043d\u0438\u0446\u0430\u043c\u0438 \u043f\u0430\u043c\u044f\u0442\u0438. \u042d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044f \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438 \u043c\u043e\u0436\u0435\u0442 \u043f\u043e\u0437\u0432\u043e\u043b\u0438\u0442\u044c \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e \u0432\u044b\u043f\u043e\u043b\u043d\u0438\u0442\u044c \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u043b\u044c\u043d\u044b\u0439 \u043a\u043e\u0434 \u0441 \u043f\u043e\u043c\u043e\u0449\u044c\u044e \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u044c\u043d\u043e \u0441\u043e\u0437\u0434\u0430\u043d\u043d\u044b\u0445 PAR-\u0444\u0430\u0439\u043b\u043e\u0432",
"\u041f\u043e\u0441\u043b\u0435\u0434\u0441\u0442\u0432\u0438\u044f \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": null,
"\u041f\u0440\u043e\u0447\u0430\u044f \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f": null,
"\u0421\u0432\u044f\u0437\u044c \u0441 \u0438\u043d\u0446\u0438\u0434\u0435\u043d\u0442\u0430\u043c\u0438 \u0418\u0411": "\u0414\u0430\u043d\u043d\u044b\u0435 \u0443\u0442\u043e\u0447\u043d\u044f\u044e\u0442\u0441\u044f",
"\u0421\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041e\u043f\u0443\u0431\u043b\u0438\u043a\u043e\u0432\u0430\u043d\u0430",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044f": "\u041e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u0435 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438": "\u041c\u0430\u043d\u0438\u043f\u0443\u043b\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0441\u0442\u0440\u0443\u043a\u0442\u0443\u0440\u0430\u043c\u0438 \u0434\u0430\u043d\u043d\u044b\u0445",
"\u0421\u0441\u044b\u043b\u043a\u0438 \u043d\u0430 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u0438": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf\nhttps://vuldb.com/ru/?id.220884",
"\u0421\u0442\u0430\u0442\u0443\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0430 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u043c",
"\u0422\u0438\u043f \u041f\u041e": "\u041f\u0440\u0438\u043a\u043b\u0430\u0434\u043d\u043e\u0435 \u041f\u041e \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u043e\u043d\u043d\u044b\u0445 \u0441\u0438\u0441\u0442\u0435\u043c",
"\u0422\u0438\u043f \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "CWE-125",
"\u0423\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0412\u044b\u0441\u043e\u043a\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 2.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 7,2)\n\u0412\u044b\u0441\u043e\u043a\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 3.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 7,8)"
}
SSA-491245
Vulnerability from csaf_siemens - Published: 2023-02-14 00:00 - Updated: 2023-03-14 00:00Summary
SSA-491245: Multiple File Parsing Vulnerabilities in Solid Edge
Notes
Summary: Solid Edge is affected by multiple memory corruption vulnerabilities that could be triggered when the application reads specially crafted files in various formats such as X_B, DWG, DXF, STL, STP, SLDPRT and PAR format. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the vulnerability to crash the application, extract data or potentially lead to arbitrary code execution.
Siemens has released updates for the affected products and recommends to update to the latest versions.
General Recommendations: As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download:
https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources: For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use: Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.
CWE-787
- Out-of-bounds Write
Mitigation
Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge
Vendor Fix
Update to V222.0MP12 or later version
https://support.sw.siemens.com/
CWE-125
- Out-of-bounds Read
Mitigation
Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge
Vendor Fix
Update to V222.0MP12 or later version
https://support.sw.siemens.com/
CWE-787
- Out-of-bounds Write
Mitigation
Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge
Vendor Fix
Update to V222.0MP12 or later version
https://support.sw.siemens.com/
CWE-787
- Out-of-bounds Write
Mitigation
Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge
Vendor Fix
Update to V222.0MP12 or later version
https://support.sw.siemens.com/
CWE-125
- Out-of-bounds Read
Mitigation
Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge
Vendor Fix
Update to V222.0MP12 or later version
https://support.sw.siemens.com/
CWE-787
- Out-of-bounds Write
Mitigation
Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge
No Fix Planned
Currently no fix is planned
Vendor Fix
Update to V222.0MP12 or later version
https://support.sw.siemens.com/
Vendor Fix
Update to V223.0Update2 or later version
https://support.sw.siemens.com/
CWE-787
- Out-of-bounds Write
Mitigation
Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge
No Fix Planned
Currently no fix is planned
Vendor Fix
Update to V222.0MP12 or later version
https://support.sw.siemens.com/
Vendor Fix
Update to V223.0Update2 or later version
https://support.sw.siemens.com/
CWE-787
- Out-of-bounds Write
Mitigation
Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge
No Fix Planned
Currently no fix is planned
Vendor Fix
Update to V222.0MP12 or later version
https://support.sw.siemens.com/
Vendor Fix
Update to V223.0Update2 or later version
https://support.sw.siemens.com/
CWE-787
- Out-of-bounds Write
Mitigation
Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge
No Fix Planned
Currently no fix is planned
Vendor Fix
Update to V222.0MP12 or later version
https://support.sw.siemens.com/
Vendor Fix
Update to V223.0Update2 or later version
https://support.sw.siemens.com/
CWE-125
- Out-of-bounds Read
Mitigation
Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge
No Fix Planned
Currently no fix is planned
Vendor Fix
Update to V222.0MP12 or later version
https://support.sw.siemens.com/
Vendor Fix
Update to V223.0Update2 or later version
https://support.sw.siemens.com/
CWE-125
- Out-of-bounds Read
Mitigation
Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge
No Fix Planned
Currently no fix is planned
Vendor Fix
Update to V222.0MP12 or later version
https://support.sw.siemens.com/
Vendor Fix
Update to V223.0Update2 or later version
https://support.sw.siemens.com/
CWE-125
- Out-of-bounds Read
Mitigation
Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge
No Fix Planned
Currently no fix is planned
Vendor Fix
Update to V222.0MP12 or later version
https://support.sw.siemens.com/
Vendor Fix
Update to V223.0Update2 or later version
https://support.sw.siemens.com/
CWE-125
- Out-of-bounds Read
Mitigation
Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge
No Fix Planned
Currently no fix is planned
Vendor Fix
Update to V222.0MP12 or later version
https://support.sw.siemens.com/
Vendor Fix
Update to V223.0Update2 or later version
https://support.sw.siemens.com/
CWE-122
- Heap-based Buffer Overflow
Mitigation
Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge
No Fix Planned
Currently no fix is planned
Vendor Fix
Update to V222.0MP12 or later version
https://support.sw.siemens.com/
Vendor Fix
Update to V223.0Update2 or later version
https://support.sw.siemens.com/
CWE-122
- Heap-based Buffer Overflow
Mitigation
Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge
No Fix Planned
Currently no fix is planned
Vendor Fix
Update to V222.0MP12 or later version
https://support.sw.siemens.com/
Vendor Fix
Update to V223.0Update2 or later version
https://support.sw.siemens.com/
CWE-125
- Out-of-bounds Read
Mitigation
Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge
No Fix Planned
Currently no fix is planned
Vendor Fix
Update to V222.0MP12 or later version
https://support.sw.siemens.com/
Vendor Fix
Update to V223.0Update2 or later version
https://support.sw.siemens.com/
CWE-787
- Out-of-bounds Write
Mitigation
Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge
No Fix Planned
Currently no fix is planned
Vendor Fix
Update to V222.0MP12 or later version
https://support.sw.siemens.com/
Vendor Fix
Update to V223.0Update2 or later version
https://support.sw.siemens.com/
CWE-121
- Stack-based Buffer Overflow
Mitigation
Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge
Vendor Fix
Update to V222.0MP12 or later version
https://support.sw.siemens.com/
Vendor Fix
Update to V223.0Update2 or later version
https://support.sw.siemens.com/
CWE-122
- Heap-based Buffer Overflow
Mitigation
Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge
Vendor Fix
Update to V222.0MP12 or later version
https://support.sw.siemens.com/
Vendor Fix
Update to V223.0Update2 or later version
https://support.sw.siemens.com/
CWE-122
- Heap-based Buffer Overflow
Mitigation
Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge
Vendor Fix
Update to V222.0MP12 or later version
https://support.sw.siemens.com/
Vendor Fix
Update to V223.0Update2 or later version
https://support.sw.siemens.com/
CWE-125
- Out-of-bounds Read
Mitigation
Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge
Vendor Fix
Update to V222.0MP12 or later version
https://support.sw.siemens.com/
Vendor Fix
Update to V223.0Update2 or later version
https://support.sw.siemens.com/
CWE-125
- Out-of-bounds Read
Mitigation
Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge
Vendor Fix
Update to V222.0MP12 or later version
https://support.sw.siemens.com/
Vendor Fix
Update to V223.0Update2 or later version
https://support.sw.siemens.com/
CWE-125
- Out-of-bounds Read
Mitigation
Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge
Vendor Fix
Update to V222.0MP12 or later version
https://support.sw.siemens.com/
Vendor Fix
Update to V223.0Update2 or later version
https://support.sw.siemens.com/
CWE-125
- Out-of-bounds Read
Mitigation
Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge
Vendor Fix
Update to V222.0MP12 or later version
https://support.sw.siemens.com/
Vendor Fix
Update to V223.0Update2 or later version
https://support.sw.siemens.com/
CWE-125
- Out-of-bounds Read
Mitigation
Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge
Vendor Fix
Update to V222.0MP12 or later version
https://support.sw.siemens.com/
Vendor Fix
Update to V223.0Update2 or later version
https://support.sw.siemens.com/
CWE-125
- Out-of-bounds Read
Mitigation
Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge
Vendor Fix
Update to V222.0MP12 or later version
https://support.sw.siemens.com/
Vendor Fix
Update to V223.0Update2 or later version
https://support.sw.siemens.com/
CWE-125
- Out-of-bounds Read
Mitigation
Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge
Vendor Fix
Update to V222.0MP12 or later version
https://support.sw.siemens.com/
Vendor Fix
Update to V223.0Update2 or later version
https://support.sw.siemens.com/
CWE-125
- Out-of-bounds Read
Mitigation
Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge
Vendor Fix
Update to V222.0MP12 or later version
https://support.sw.siemens.com/
Vendor Fix
Update to V223.0Update2 or later version
https://support.sw.siemens.com/
CWE-787
- Out-of-bounds Write
Mitigation
Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge
Vendor Fix
Update to V222.0MP12 or later version
https://support.sw.siemens.com/
Vendor Fix
Update to V223.0Update2 or later version
https://support.sw.siemens.com/
CWE-824
- Access of Uninitialized Pointer
Mitigation
Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge
Vendor Fix
Update to V222.0MP12 or later version
https://support.sw.siemens.com/
Vendor Fix
Update to V223.0Update2 or later version
https://support.sw.siemens.com/
CWE-824
- Access of Uninitialized Pointer
Mitigation
Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge
Vendor Fix
Update to V222.0MP12 or later version
https://support.sw.siemens.com/
Vendor Fix
Update to V223.0Update2 or later version
https://support.sw.siemens.com/
CWE-824
- Access of Uninitialized Pointer
Mitigation
Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge
Vendor Fix
Update to V222.0MP12 or later version
https://support.sw.siemens.com/
Vendor Fix
Update to V223.0Update2 or later version
https://support.sw.siemens.com/
CWE-119
- Improper Restriction of Operations within the Bounds of a Memory Buffer
Mitigation
Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge
No Fix Planned
Currently no fix is planned
Vendor Fix
Update to V222.0MP12 or later version
https://support.sw.siemens.com/
Vendor Fix
Update to V223.0Update2 or later version
https://support.sw.siemens.com/
CWE-125
- Out-of-bounds Read
Mitigation
Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge
No Fix Planned
Currently no fix is planned
Vendor Fix
Update to V222.0MP12 or later version
https://support.sw.siemens.com/
Vendor Fix
Update to V223.0Update2 or later version
https://support.sw.siemens.com/
CWE-121
- Stack-based Buffer Overflow
Mitigation
Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge
No Fix Planned
Currently no fix is planned
Vendor Fix
Update to V222.0MP12 or later version
https://support.sw.siemens.com/
Vendor Fix
Update to V223.0Update2 or later version
https://support.sw.siemens.com/
CWE-416
- Use After Free
Mitigation
Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge
No Fix Planned
Currently no fix is planned
Vendor Fix
Update to V222.0MP12 or later version
https://support.sw.siemens.com/
Vendor Fix
Update to V223.0Update2 or later version
https://support.sw.siemens.com/
CWE-125
- Out-of-bounds Read
Mitigation
Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge
Vendor Fix
Update to V222.0MP12 or later version
https://support.sw.siemens.com/
References
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
"tlp": {
"label": "WHITE"
}
},
"notes": [
{
"category": "summary",
"text": "Solid Edge is affected by multiple memory corruption vulnerabilities that could be triggered when the application reads specially crafted files in various formats such as X_B, DWG, DXF, STL, STP, SLDPRT and PAR format. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the vulnerability to crash the application, extract data or potentially lead to arbitrary code execution.\n\nSiemens has released updates for the affected products and recommends to update to the latest versions.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-491245: Multiple File Parsing Vulnerabilities in Solid Edge - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf"
},
{
"category": "self",
"summary": "SSA-491245: Multiple File Parsing Vulnerabilities in Solid Edge - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-491245.txt"
},
{
"category": "self",
"summary": "SSA-491245: Multiple File Parsing Vulnerabilities in Solid Edge - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-491245.json"
}
],
"title": "SSA-491245: Multiple File Parsing Vulnerabilities in Solid Edge",
"tracking": {
"current_release_date": "2023-03-14T00:00:00Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-491245",
"initial_release_date": "2023-02-14T00:00:00Z",
"revision_history": [
{
"date": "2023-02-14T00:00:00Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2023-03-14T00:00:00Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Correction in version formats of fixes"
}
],
"status": "interim",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Solid Edge SE2022",
"product_id": "1"
}
},
{
"category": "product_version_range",
"name": "\u003c V222.0MP12",
"product": {
"name": "Solid Edge SE2022",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "Solid Edge SE2022"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V223.0Update2",
"product": {
"name": "Solid Edge SE2023",
"product_id": "3"
}
}
],
"category": "product_name",
"name": "Solid Edge SE2023"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2021-32936",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "Open Design Alliance Drawings SDK before 2022.4 contains an out-of-bounds write issue while parsing specially crafted DXF files. This could result in a write past the end of an allocated buffer and allow an attacker to execute code in the context of the current process. (ZDI-CAN-13408, ZDI-CAN-19072)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2"
]
}
],
"title": "CVE-2021-32936"
},
{
"cve": "CVE-2021-32938",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "Open Design Alliance Drawings SDK before 2022.4 are vulnerable to an out-of-bounds read while parsing specially crafted DWG files. This could allow an attacker to read sensitive information from memory locations and to cause a denial of service (crash). (ZDI-CAN-13378, ZDI-CAN-19073)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2"
]
}
],
"title": "CVE-2021-32938"
},
{
"cve": "CVE-2021-32948",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "Open Design Alliance Drawings SDK before 2022.4 contains an out-of-bounds write issue while parsing specially crafted DWG files. This could result in a write past the end of an allocated buffer and allow an attacker to execute code in the context of the current process. (ZDI-CAN-19074, ZDI-CAN-13410)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2"
]
}
],
"title": "CVE-2021-32948"
},
{
"cve": "CVE-2021-43336",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "Open Design Alliance Drawings SDK before 2022.11 used in affected products contains an out of bounds write vulnerability when parsing a DXF file. An attacker can leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-15107, ZDI-CAN-19080, ZDI-CAN-19075)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2"
]
}
],
"title": "CVE-2021-43336"
},
{
"cve": "CVE-2021-43391",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "Open Design Alliance Drawings SDK before 2022.11 used in affected products contains an out of bounds write vulnerability when parsing a DXF file. An attacker can leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19082)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2"
]
}
],
"title": "CVE-2021-43391"
},
{
"cve": "CVE-2022-46345",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19070)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"1",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"1",
"3"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"1",
"3"
]
}
],
"title": "CVE-2022-46345"
},
{
"cve": "CVE-2022-46346",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19071)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"1",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"1",
"3"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"1",
"3"
]
}
],
"title": "CVE-2022-46346"
},
{
"cve": "CVE-2022-46347",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19079)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"1",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"1",
"3"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"1",
"3"
]
}
],
"title": "CVE-2022-46347"
},
{
"cve": "CVE-2022-46348",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19383)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"1",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"1",
"3"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"1",
"3"
]
}
],
"title": "CVE-2022-46348"
},
{
"cve": "CVE-2022-46349",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19384)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"1",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"1",
"3"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"1",
"3"
]
}
],
"title": "CVE-2022-46349"
},
{
"cve": "CVE-2023-22295",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "Datakit CrossCadWare_x64.dll used in affected products contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted SLDPRT file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19448)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"1",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"1",
"3"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"1",
"3"
]
}
],
"title": "CVE-2023-22295"
},
{
"cve": "CVE-2023-22321",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "Datakit CrossCadWare_x64.dll used in affected products contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted SLDPRT file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19501)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"1",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"1",
"3"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"1",
"3"
]
}
],
"title": "CVE-2023-22321"
},
{
"cve": "CVE-2023-22354",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "Datakit CrossCadWare_x64.dll used in affected products \r\n contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted SLDPRT file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19424)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"1",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"1",
"3"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"1",
"3"
]
}
],
"title": "CVE-2023-22354"
},
{
"cve": "CVE-2023-22669",
"cwe": {
"id": "CWE-122",
"name": "Heap-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "Open Design Alliance Drawings SDK used in affected application is vulnerable to heap-based buffer while parsing specially crafted DWG files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19104)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"1",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"1",
"3"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"1",
"3"
]
}
],
"title": "CVE-2023-22669"
},
{
"cve": "CVE-2023-22670",
"cwe": {
"id": "CWE-122",
"name": "Heap-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "Open Design Alliance Drawings SDK used in affected application is vulnerable to heap-based buffer while parsing specially crafted DWG files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19382)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"1",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"1",
"3"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"1",
"3"
]
}
],
"title": "CVE-2023-22670"
},
{
"cve": "CVE-2023-22846",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "Datakit CrossCadWare_x64.dll used in affected products contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted SLDPRT file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19473)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"1",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"1",
"3"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"1",
"3"
]
}
],
"title": "CVE-2023-22846"
},
{
"cve": "CVE-2023-23579",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "Datakit CrossCadWare_x64.dll used in affected products contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SLDPRT file. This could allow an attacker to to execute code in the context of the current process. (ZDI-CAN-19423)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"1",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"1",
"3"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"1",
"3"
]
}
],
"title": "CVE-2023-23579"
},
{
"cve": "CVE-2023-24549",
"cwe": {
"id": "CWE-121",
"name": "Stack-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "The affected application is vulnerable to stack-based buffer while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"3"
]
}
],
"title": "CVE-2023-24549"
},
{
"cve": "CVE-2023-24550",
"cwe": {
"id": "CWE-122",
"name": "Heap-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "The affected application is vulnerable to heap-based buffer while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"3"
]
}
],
"title": "CVE-2023-24550"
},
{
"cve": "CVE-2023-24551",
"cwe": {
"id": "CWE-122",
"name": "Heap-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "The affected application is vulnerable to heap-based buffer underflow while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"3"
]
}
],
"title": "CVE-2023-24551"
},
{
"cve": "CVE-2023-24552",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "The affected application contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted PAR file. This could allow an attacker to to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"3"
]
}
],
"title": "CVE-2023-24552"
},
{
"cve": "CVE-2023-24553",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"3"
]
}
],
"title": "CVE-2023-24553"
},
{
"cve": "CVE-2023-24554",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"3"
]
}
],
"title": "CVE-2023-24554"
},
{
"cve": "CVE-2023-24555",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"3"
]
}
],
"title": "CVE-2023-24555"
},
{
"cve": "CVE-2023-24556",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"3"
]
}
],
"title": "CVE-2023-24556"
},
{
"cve": "CVE-2023-24557",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"3"
]
}
],
"title": "CVE-2023-24557"
},
{
"cve": "CVE-2023-24558",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"3"
]
}
],
"title": "CVE-2023-24558"
},
{
"cve": "CVE-2023-24559",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"3"
]
}
],
"title": "CVE-2023-24559"
},
{
"cve": "CVE-2023-24560",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted PAR file. This could allow an attacker to to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"3"
]
}
],
"title": "CVE-2023-24560"
},
{
"cve": "CVE-2023-24561",
"cwe": {
"id": "CWE-824",
"name": "Access of Uninitialized Pointer"
},
"notes": [
{
"category": "summary",
"text": "The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"3"
]
}
],
"title": "CVE-2023-24561"
},
{
"cve": "CVE-2023-24562",
"cwe": {
"id": "CWE-824",
"name": "Access of Uninitialized Pointer"
},
"notes": [
{
"category": "summary",
"text": "The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"3"
]
}
],
"title": "CVE-2023-24562"
},
{
"cve": "CVE-2023-24563",
"cwe": {
"id": "CWE-824",
"name": "Access of Uninitialized Pointer"
},
"notes": [
{
"category": "summary",
"text": "The affected application is vulnerable to uninitialized pointer access while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"3"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"3"
]
}
],
"title": "CVE-2023-24563"
},
{
"cve": "CVE-2023-24564",
"cwe": {
"id": "CWE-119",
"name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
},
"notes": [
{
"category": "summary",
"text": "The affected application contains a memory corruption vulnerability while parsing specially crafted DWG files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19069)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"1",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"1",
"3"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"1",
"3"
]
}
],
"title": "CVE-2023-24564"
},
{
"cve": "CVE-2023-24565",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "The affected application contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted STL file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19428)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"1",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"1",
"3"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"1",
"3"
]
}
],
"title": "CVE-2023-24565"
},
{
"cve": "CVE-2023-24566",
"cwe": {
"id": "CWE-121",
"name": "Stack-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "The affected application is vulnerable to stack-based buffer while parsing specially crafted PAR files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19472)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"1",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"1",
"3"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.3,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"1",
"3"
]
}
],
"title": "CVE-2023-24566"
},
{
"cve": "CVE-2023-24581",
"cwe": {
"id": "CWE-416",
"name": "Use After Free"
},
"notes": [
{
"category": "summary",
"text": "The affected application contains a use-after-free vulnerability that could be triggered while parsing specially crafted STP files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-19425)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2",
"1",
"3"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2",
"1",
"3"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V223.0Update2 or later version",
"product_ids": [
"3"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2",
"1",
"3"
]
}
],
"title": "CVE-2023-24581"
},
{
"cve": "CVE-2023-25140",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"2"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted X_B, DWG, DXF, STL, STP, SLDPRT and PAR files in Solid Edge",
"product_ids": [
"2"
]
},
{
"category": "vendor_fix",
"details": "Update to V222.0MP12 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"2"
]
}
],
"title": "CVE-2023-25140"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…