CVE-2017-7902 (GCVE-0-2017-7902)
Vulnerability from cvelistv5 – Published: 2017-06-30 02:35 – Updated: 2024-08-05 16:19| URL | Tags |
|---|---|
| http://www.securitytracker.com/id/1038546 | vdb-entryx_refsource_SECTRACK |
| https://ics-cert.us-cert.gov/advisories/ICSA-17-115-04 | x_refsource_MISC |
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| n/a | Rockwell Automation Allen-Bradley MicroLogix 1100 and 1400 |
Affected:
Rockwell Automation Allen-Bradley MicroLogix 1100 and 1400
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T16:19:28.546Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "1038546",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK",
"x_transferred"
],
"url": "http://www.securitytracker.com/id/1038546"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-115-04"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Rockwell Automation Allen-Bradley MicroLogix 1100 and 1400",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Rockwell Automation Allen-Bradley MicroLogix 1100 and 1400"
}
]
}
],
"datePublic": "2017-06-29T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A \"Reusing a Nonce, Key Pair in Encryption\" issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. The affected product reuses nonces, which may allow an attacker to capture and replay a valid request until the nonce is changed."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-323",
"description": "CWE-323",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-07-07T09:57:01.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"name": "1038546",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK"
],
"url": "http://www.securitytracker.com/id/1038546"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-115-04"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2017-7902",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Rockwell Automation Allen-Bradley MicroLogix 1100 and 1400",
"version": {
"version_data": [
{
"version_value": "Rockwell Automation Allen-Bradley MicroLogix 1100 and 1400"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A \"Reusing a Nonce, Key Pair in Encryption\" issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. The affected product reuses nonces, which may allow an attacker to capture and replay a valid request until the nonce is changed."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-323"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "1038546",
"refsource": "SECTRACK",
"url": "http://www.securitytracker.com/id/1038546"
},
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-115-04",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-115-04"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2017-7902",
"datePublished": "2017-06-30T02:35:00.000Z",
"dateReserved": "2017-04-18T00:00:00.000Z",
"dateUpdated": "2024-08-05T16:19:28.546Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2017-7902",
"date": "2026-11-08",
"epss": "0.02559",
"percentile": "0.85191"
},
"fkie_nvd": {
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:rockwellautomation:1763-l16awa_series_a:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E44D0CCE-EDA7-4DF2-B67B-C59DFAE7F888",
"versionEndIncluding": "16.000",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:rockwellautomation:1763-l16awa_series_b:*:*:*:*:*:*:*:*",
"matchCriteriaId": "58E4AB51-E136-4AA3-AFF9-50F240489856",
"versionEndIncluding": "16.000",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:rockwellautomation:1763-l16bbb_series_a:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6006CE1E-08EC-4AFC-8F35-73B24AA7F08D",
"versionEndIncluding": "16.000",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:rockwellautomation:1763-l16bbb_series_b:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F52398D3-996E-4291-887F-6B8E0AF24AFF",
"versionEndIncluding": "16.000",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:rockwellautomation:1763-l16bwa_series_a:*:*:*:*:*:*:*:*",
"matchCriteriaId": "61603F24-7505-4A9E-BA9E-57C7B5A60A6E",
"versionEndIncluding": "16.000",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:rockwellautomation:1763-l16bwa_series_b:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9558148B-3000-4D83-9AB0-380D7FBB0C9A",
"versionEndIncluding": "16.000",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:rockwellautomation:1763-l16dwd_series_a:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C805AFD6-481C-4A32-9CE8-281F9B793263",
"versionEndIncluding": "16.000",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:rockwellautomation:1763-l16dwd_series_b:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DC9E1F42-4F17-4EA4-8D0F-30220F560A0E",
"versionEndIncluding": "16.000",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:ab_micrologix_controller:1100:*:*:*:*:*:*:*",
"matchCriteriaId": "FA98842B-9D09-4C37-AB34-4E9FA566BAD8",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:rockwellautomation:1766-l32awa_series_a:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8C8E3AF6-1017-4A18-99CA-854F1022ED66",
"versionEndIncluding": "16.000",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:rockwellautomation:1766-l32awa_series_b:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A093AA8B-7DB9-4373-AE8F-F8B879A4BE5E",
"versionEndIncluding": "16.000",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:rockwellautomation:1766-l32awaa_series_a:*:*:*:*:*:*:*:*",
"matchCriteriaId": "25DA9309-964B-4C1C-8B95-9C1CD80DDC74",
"versionEndIncluding": "16.000",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:rockwellautomation:1766-l32awaa_series_b:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6D51D3F6-ABB3-4FFD-81D5-B3D3C29F0A46",
"versionEndIncluding": "16.000",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:rockwellautomation:1766-l32bwa_series_a:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DC05C3A1-1042-46AD-83D8-765AF4C9BCD9",
"versionEndIncluding": "16.000",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:rockwellautomation:1766-l32bwa_series_b:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6218A006-1F60-4E29-85CC-7D1BCBD7C734",
"versionEndIncluding": "16.000",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:rockwellautomation:1766-l32bwaa_series_a:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6B863572-CECF-47DF-AF6F-C25F88200DBE",
"versionEndIncluding": "16.000",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:rockwellautomation:1766-l32bwaa_series_b:*:*:*:*:*:*:*:*",
"matchCriteriaId": "59BEBB0E-8C6E-4663-9E0C-E755C2EF0041",
"versionEndIncluding": "16.000",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:rockwellautomation:1766-l32bxb_series_a:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1303D987-4A44-4F33-992E-0C7E683EC7A9",
"versionEndIncluding": "16.000",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:rockwellautomation:1766-l32bxb_series_b:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1E7D8E09-D97D-45FF-9AD0-A9B0A846E600",
"versionEndIncluding": "16.000",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:rockwellautomation:1766-l32bxba_series_a:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9D9C64FB-A613-4940-86E6-95431B907159",
"versionEndIncluding": "16.000",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:rockwellautomation:1766-l32bxba_series_b:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B5C50D4A-EB32-4BE4-B9E6-D25494E2EF55",
"versionEndIncluding": "16.000",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:ab_micrologix_controller:1400:*:*:*:*:*:*:*",
"matchCriteriaId": "FFF2EF59-F451-490D-A7AF-E66D11493948",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"descriptions": [
{
"lang": "en",
"value": "A \"Reusing a Nonce, Key Pair in Encryption\" issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. The affected product reuses nonces, which may allow an attacker to capture and replay a valid request until the nonce is changed."
},
{
"lang": "es",
"value": "Se detect\u00f3 un problema de \"Reusing a Nonce, Key Pair in Encryption\" en los controladores de l\u00f3gica programable MicroLogix 1100 de Allen-Bradley 1763-L16AWA, Serie A y B, Versi\u00f3n 16.00 y versiones anteriores; 1763-L16BBB, Serie A y B, Versi\u00f3n 16.00 y versiones anteriores; 1763-L16BWA, Serie A y B, Versi\u00f3n 16.00 y versiones anteriores; y 1763-L16DWD, Serie A y B, Versi\u00f3n 16.00 y versiones anteriores y Controladores l\u00f3gicos programables Allen-Bradley MicroLogix 1400 1766-L32AWA, Serie A y B, Versi\u00f3n 16.00 y versiones anteriores; 1766-L32BWA, Series A y B, versi\u00f3n 16.00 y versiones anteriores; 1766-L32BWAA, Serie A y B, Versi\u00f3n 16.00 y versiones anteriores; 1766-L32BXB, Serie A y B, Versi\u00f3n 16.00 y versiones anteriores; 1766-L32BXBA, Serie A y B, Versi\u00f3n 16.00 y versiones anteriores; y 1766-L32AWAA, Serie A y B, Versi\u00f3n 16.00 y versiones anteriores. El producto afectado reutiliza nonces, lo que puede permitir que un atacante capture y reproduzca una solicitud v\u00e1lida hasta que se cambie el nonce."
}
],
"id": "CVE-2017-7902",
"lastModified": "2024-11-21T03:32:55.810",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2017-06-30T03:29:00.827",
"references": [
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securitytracker.com/id/1038546"
},
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Patch",
"Third Party Advisory",
"US Government Resource"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-115-04"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securitytracker.com/id/1038546"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Third Party Advisory",
"US Government Resource"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-115-04"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-323"
}
],
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-330"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"nvd": {
"cve": {
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:rockwellautomation:1763-l16awa_series_a:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E44D0CCE-EDA7-4DF2-B67B-C59DFAE7F888",
"versionEndIncluding": "16.000",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:rockwellautomation:1763-l16awa_series_b:*:*:*:*:*:*:*:*",
"matchCriteriaId": "58E4AB51-E136-4AA3-AFF9-50F240489856",
"versionEndIncluding": "16.000",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:rockwellautomation:1763-l16bbb_series_a:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6006CE1E-08EC-4AFC-8F35-73B24AA7F08D",
"versionEndIncluding": "16.000",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:rockwellautomation:1763-l16bbb_series_b:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F52398D3-996E-4291-887F-6B8E0AF24AFF",
"versionEndIncluding": "16.000",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:rockwellautomation:1763-l16bwa_series_a:*:*:*:*:*:*:*:*",
"matchCriteriaId": "61603F24-7505-4A9E-BA9E-57C7B5A60A6E",
"versionEndIncluding": "16.000",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:rockwellautomation:1763-l16bwa_series_b:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9558148B-3000-4D83-9AB0-380D7FBB0C9A",
"versionEndIncluding": "16.000",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:rockwellautomation:1763-l16dwd_series_a:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C805AFD6-481C-4A32-9CE8-281F9B793263",
"versionEndIncluding": "16.000",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:rockwellautomation:1763-l16dwd_series_b:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DC9E1F42-4F17-4EA4-8D0F-30220F560A0E",
"versionEndIncluding": "16.000",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:ab_micrologix_controller:1100:*:*:*:*:*:*:*",
"matchCriteriaId": "FA98842B-9D09-4C37-AB34-4E9FA566BAD8",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:rockwellautomation:1766-l32awa_series_a:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8C8E3AF6-1017-4A18-99CA-854F1022ED66",
"versionEndIncluding": "16.000",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:rockwellautomation:1766-l32awa_series_b:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A093AA8B-7DB9-4373-AE8F-F8B879A4BE5E",
"versionEndIncluding": "16.000",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:rockwellautomation:1766-l32awaa_series_a:*:*:*:*:*:*:*:*",
"matchCriteriaId": "25DA9309-964B-4C1C-8B95-9C1CD80DDC74",
"versionEndIncluding": "16.000",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:rockwellautomation:1766-l32awaa_series_b:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6D51D3F6-ABB3-4FFD-81D5-B3D3C29F0A46",
"versionEndIncluding": "16.000",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:rockwellautomation:1766-l32bwa_series_a:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DC05C3A1-1042-46AD-83D8-765AF4C9BCD9",
"versionEndIncluding": "16.000",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:rockwellautomation:1766-l32bwa_series_b:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6218A006-1F60-4E29-85CC-7D1BCBD7C734",
"versionEndIncluding": "16.000",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:rockwellautomation:1766-l32bwaa_series_a:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6B863572-CECF-47DF-AF6F-C25F88200DBE",
"versionEndIncluding": "16.000",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:rockwellautomation:1766-l32bwaa_series_b:*:*:*:*:*:*:*:*",
"matchCriteriaId": "59BEBB0E-8C6E-4663-9E0C-E755C2EF0041",
"versionEndIncluding": "16.000",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:rockwellautomation:1766-l32bxb_series_a:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1303D987-4A44-4F33-992E-0C7E683EC7A9",
"versionEndIncluding": "16.000",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:rockwellautomation:1766-l32bxb_series_b:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1E7D8E09-D97D-45FF-9AD0-A9B0A846E600",
"versionEndIncluding": "16.000",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:rockwellautomation:1766-l32bxba_series_a:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9D9C64FB-A613-4940-86E6-95431B907159",
"versionEndIncluding": "16.000",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:rockwellautomation:1766-l32bxba_series_b:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B5C50D4A-EB32-4BE4-B9E6-D25494E2EF55",
"versionEndIncluding": "16.000",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:ab_micrologix_controller:1400:*:*:*:*:*:*:*",
"matchCriteriaId": "FFF2EF59-F451-490D-A7AF-E66D11493948",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A \"Reusing a Nonce, Key Pair in Encryption\" issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. The affected product reuses nonces, which may allow an attacker to capture and replay a valid request until the nonce is changed."
},
{
"lang": "es",
"value": "Se detect\u00f3 un problema de \"Reusing a Nonce, Key Pair in Encryption\" en los controladores de l\u00f3gica programable MicroLogix 1100 de Allen-Bradley 1763-L16AWA, Serie A y B, Versi\u00f3n 16.00 y versiones anteriores; 1763-L16BBB, Serie A y B, Versi\u00f3n 16.00 y versiones anteriores; 1763-L16BWA, Serie A y B, Versi\u00f3n 16.00 y versiones anteriores; y 1763-L16DWD, Serie A y B, Versi\u00f3n 16.00 y versiones anteriores y Controladores l\u00f3gicos programables Allen-Bradley MicroLogix 1400 1766-L32AWA, Serie A y B, Versi\u00f3n 16.00 y versiones anteriores; 1766-L32BWA, Series A y B, versi\u00f3n 16.00 y versiones anteriores; 1766-L32BWAA, Serie A y B, Versi\u00f3n 16.00 y versiones anteriores; 1766-L32BXB, Serie A y B, Versi\u00f3n 16.00 y versiones anteriores; 1766-L32BXBA, Serie A y B, Versi\u00f3n 16.00 y versiones anteriores; y 1766-L32AWAA, Serie A y B, Versi\u00f3n 16.00 y versiones anteriores. El producto afectado reutiliza nonces, lo que puede permitir que un atacante capture y reproduzca una solicitud v\u00e1lida hasta que se cambie el nonce."
}
],
"id": "CVE-2017-7902",
"lastModified": "2026-05-13T00:24:29.033",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2017-06-30T03:29:00.827",
"references": [
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securitytracker.com/id/1038546"
},
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Patch",
"Third Party Advisory",
"US Government Resource"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-115-04"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securitytracker.com/id/1038546"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Third Party Advisory",
"US Government Resource"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-115-04"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-323"
}
],
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-330"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
}
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.