An Improper Authentication issue was discovered in ABB VSN300 WiFi Logger Card versions 1.8.15 and prior, and VSN300 WiFi Logger Card for React versions 2.1.3 and prior. By accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access internal information about status and connected devices without authenticating.
Severity
No CVSS data available.
CWE
Assigner
References
Impacted products
Vendor Product Version
n/a ABB VSN300 WiFi Logger Card Affected: ABB VSN300 WiFi Logger Card
Date Public
2017-08-07 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T16:19:29.337Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "99558",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/99558"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://search.abb.com/library/Download.aspx?DocumentID=9AKK107045A1977\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-192-03"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "ABB VSN300 WiFi Logger Card",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "ABB VSN300 WiFi Logger Card"
            }
          ]
        }
      ],
      "datePublic": "2017-08-07T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "An Improper Authentication issue was discovered in ABB VSN300 WiFi Logger Card versions 1.8.15 and prior, and VSN300 WiFi Logger Card for React versions 2.1.3 and prior. By accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access internal information about status and connected devices without authenticating."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-08-07T09:57:02.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "99558",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/99558"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://search.abb.com/library/Download.aspx?DocumentID=9AKK107045A1977\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-192-03"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-7920",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "ABB VSN300 WiFi Logger Card",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "ABB VSN300 WiFi Logger Card"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An Improper Authentication issue was discovered in ABB VSN300 WiFi Logger Card versions 1.8.15 and prior, and VSN300 WiFi Logger Card for React versions 2.1.3 and prior. By accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access internal information about status and connected devices without authenticating."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-287"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "99558",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/99558"
            },
            {
              "name": "http://search.abb.com/library/Download.aspx?DocumentID=9AKK107045A1977\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
              "refsource": "MISC",
              "url": "http://search.abb.com/library/Download.aspx?DocumentID=9AKK107045A1977\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-192-03",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-192-03"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-7920",
    "datePublished": "2017-08-07T08:00:00.000Z",
    "dateReserved": "2017-04-18T00:00:00.000Z",
    "dateUpdated": "2024-08-05T16:19:29.337Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2017-7920",
      "date": "2026-05-30",
      "epss": "0.01403",
      "percentile": "0.80759"
    },
    "fkie_nvd": {
      "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:abb:vsn300_firmware:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"1.8.15\", \"matchCriteriaId\": \"55CE1554-02F3-48C7-9358-5BFAE8C73088\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:abb:vsn300:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"440423E1-CF52-4E64-9FFF-BA00636DAB57\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:abb:vsn300_for_react_firmware:2.1.3:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"7A99018B-9729-45B8-8E1C-1A3940329897\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:abb:vsn300_for_react:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"A14628BB-774D-436E-A2DF-C9CC66A1D3CE\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"An Improper Authentication issue was discovered in ABB VSN300 WiFi Logger Card versions 1.8.15 and prior, and VSN300 WiFi Logger Card for React versions 2.1.3 and prior. By accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access internal information about status and connected devices without authenticating.\"}, {\"lang\": \"es\", \"value\": \"Se ha descubierto un problema de autenticaci\\u00f3n incorrecta en ABB VSN300 WiFi Logger Card versiones 1.8.15 y anteriores, y VSN300 WiFi Logger Card for React versiones 2.1.3 y anteriores. Al acceder a una URL concreta en el servidor web, un usuario malicioso es capaz de acceder a informaci\\u00f3n interna acerca del estado y los dispositivos conectados sin autenticarse.\"}]",
      "id": "CVE-2017-7920",
      "lastModified": "2024-11-21T03:32:57.993",
      "metrics": "{\"cvssMetricV30\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.6}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:P/I:N/A:N\", \"baseScore\": 5.0, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 10.0, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
      "published": "2017-08-07T08:29:00.243",
      "references": "[{\"url\": \"http://search.abb.com/library/Download.aspx?DocumentID=9AKK107045A1977\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\", \"source\": \"ics-cert@hq.dhs.gov\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"http://www.securityfocus.com/bid/99558\", \"source\": \"ics-cert@hq.dhs.gov\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://ics-cert.us-cert.gov/advisories/ICSA-17-192-03\", \"source\": \"ics-cert@hq.dhs.gov\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}, {\"url\": \"http://search.abb.com/library/Download.aspx?DocumentID=9AKK107045A1977\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"http://www.securityfocus.com/bid/99558\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://ics-cert.us-cert.gov/advisories/ICSA-17-192-03\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}]",
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"ics-cert@hq.dhs.gov\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-287\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-287\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2017-7920\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2017-08-07T08:29:00.243\",\"lastModified\":\"2026-05-13T00:24:29.033\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An Improper Authentication issue was discovered in ABB VSN300 WiFi Logger Card versions 1.8.15 and prior, and VSN300 WiFi Logger Card for React versions 2.1.3 and prior. By accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access internal information about status and connected devices without authenticating.\"},{\"lang\":\"es\",\"value\":\"Se ha descubierto un problema de autenticaci\u00f3n incorrecta en ABB VSN300 WiFi Logger Card versiones 1.8.15 y anteriores, y VSN300 WiFi Logger Card for React versiones 2.1.3 y anteriores. Al acceder a una URL concreta en el servidor web, un usuario malicioso es capaz de acceder a informaci\u00f3n interna acerca del estado y los dispositivos conectados sin autenticarse.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:N/A:N\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-287\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-287\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:abb:vsn300_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"1.8.15\",\"matchCriteriaId\":\"55CE1554-02F3-48C7-9358-5BFAE8C73088\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:abb:vsn300:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"440423E1-CF52-4E64-9FFF-BA00636DAB57\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:abb:vsn300_for_react_firmware:2.1.3:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7A99018B-9729-45B8-8E1C-1A3940329897\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:abb:vsn300_for_react:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A14628BB-774D-436E-A2DF-C9CC66A1D3CE\"}]}]}],\"references\":[{\"url\":\"http://search.abb.com/library/Download.aspx?DocumentID=9AKK107045A1977\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/99558\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-17-192-03\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"http://search.abb.com/library/Download.aspx?DocumentID=9AKK107045A1977\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/99558\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-17-192-03\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…