CVE-2018-12208 (GCVE-0-2018-12208)
Vulnerability from cvelistv5 – Published: 2019-03-14 20:00 – Updated: 2024-09-17 00:16
VLAI?
Summary
Buffer overflow in HECI subsystem in Intel(R) CSME before versions 11.8.60, 11.11.60, 11.22.60 or 12.0.20 and Intel(R) TXE version before 3.1.60 or 4.0.10, or Intel(R) Server Platform Services before version 5.00.04.012 may allow an unauthenticated user to potentially execute arbitrary code via physical access.
Severity ?
No CVSS data available.
CWE
- Escalation of Privilege
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Intel Corporation | Intel(R) CSME, Server Platform Services, Trusted Execution Engine and Intel(R) Active Management Technology |
Affected:
Multiple versions.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T08:30:59.094Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/INTEL-SA-00185.html"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20190318-0001/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03914en_us"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Intel(R) CSME, Server Platform Services, Trusted Execution Engine and Intel(R) Active Management Technology",
"vendor": "Intel Corporation",
"versions": [
{
"status": "affected",
"version": "Multiple versions."
}
]
}
],
"datePublic": "2019-03-12T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Buffer overflow in HECI subsystem in Intel(R) CSME before versions 11.8.60, 11.11.60, 11.22.60 or 12.0.20 and Intel(R) TXE version before 3.1.60 or 4.0.10, or Intel(R) Server Platform Services before version 5.00.04.012 may allow an unauthenticated user to potentially execute arbitrary code via physical access."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Escalation of Privilege",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-04-04T21:06:06",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/INTEL-SA-00185.html"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://security.netapp.com/advisory/ntap-20190318-0001/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03914en_us"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@intel.com",
"DATE_PUBLIC": "2019-03-12T00:00:00",
"ID": "CVE-2018-12208",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Intel(R) CSME, Server Platform Services, Trusted Execution Engine and Intel(R) Active Management Technology",
"version": {
"version_data": [
{
"version_value": "Multiple versions."
}
]
}
}
]
},
"vendor_name": "Intel Corporation"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Buffer overflow in HECI subsystem in Intel(R) CSME before versions 11.8.60, 11.11.60, 11.22.60 or 12.0.20 and Intel(R) TXE version before 3.1.60 or 4.0.10, or Intel(R) Server Platform Services before version 5.00.04.012 may allow an unauthenticated user to potentially execute arbitrary code via physical access."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Escalation of Privilege"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/INTEL-SA-00185.html",
"refsource": "CONFIRM",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/INTEL-SA-00185.html"
},
{
"name": "https://security.netapp.com/advisory/ntap-20190318-0001/",
"refsource": "CONFIRM",
"url": "https://security.netapp.com/advisory/ntap-20190318-0001/"
},
{
"name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03914en_us",
"refsource": "CONFIRM",
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03914en_us"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2018-12208",
"datePublished": "2019-03-14T20:00:00Z",
"dateReserved": "2018-06-11T00:00:00",
"dateUpdated": "2024-09-17T00:16:21.349Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:intel:converged_security_management_engine_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"11.0\", \"versionEndExcluding\": \"11.8.60\", \"matchCriteriaId\": \"89FAC2D9-E921-4F45-B786-0902B310C2A3\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:intel:converged_security_management_engine_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"11.10\", \"versionEndExcluding\": \"11.11.60\", \"matchCriteriaId\": \"EB85F0E9-95F9-452C-AAAF-0C8CCCE76C59\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:intel:converged_security_management_engine_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"11.20\", \"versionEndExcluding\": \"11.22.60\", \"matchCriteriaId\": \"3A44D8E6-445C-475D-BB1A-75C03AEE940B\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:intel:converged_security_management_engine_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"12.0.0\", \"versionEndExcluding\": \"12.0.20\", \"matchCriteriaId\": \"91671FB7-F021-4781-9CBD-E7B66727B747\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:intel:server_platform_services_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"5.00.04.012\", \"matchCriteriaId\": \"7202A001-9A4F-4E3D-8B61-9DB27638A7AD\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:intel:trusted_execution_engine_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"3.0\", \"versionEndExcluding\": \"3.1.60\", \"matchCriteriaId\": \"3029FF22-3BD0-41A7-BBF9-E6183DF2BD31\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:intel:trusted_execution_engine_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"4.0\", \"versionEndExcluding\": \"4.0.10\", \"matchCriteriaId\": \"916A348F-144A-4A81-B93F-D3422A662D09\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"Buffer overflow in HECI subsystem in Intel(R) CSME before versions 11.8.60, 11.11.60, 11.22.60 or 12.0.20 and Intel(R) TXE version before 3.1.60 or 4.0.10, or Intel(R) Server Platform Services before version 5.00.04.012 may allow an unauthenticated user to potentially execute arbitrary code via physical access.\"}, {\"lang\": \"es\", \"value\": \"Desbordamiento de b\\u00fafer en el subsistema HECI de Intel(R) CSME, en versiones anteriores a las 11.8.60, 11.11.60, 11.22.60 o 12.0.20; o Intel (R) TXE, en versiones anteriores a la 3.1.60 o 4.0.10; o Intel(R) Server Platform Services en versiones anteriores a la 5.00.04.012 podr\\u00eda permitir que un usuario no autenticado pueda ejecutar c\\u00f3digo arbitrario mediante acceso f\\u00edsico.\"}]",
"id": "CVE-2018-12208",
"lastModified": "2024-11-21T03:44:46.920",
"metrics": "{\"cvssMetricV30\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H\", \"baseScore\": 7.6, \"baseSeverity\": \"HIGH\", \"attackVector\": \"PHYSICAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 0.9, \"impactScore\": 6.0}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:L/AC:L/Au:N/C:P/I:P/A:P\", \"baseScore\": 4.6, \"accessVector\": \"LOCAL\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 3.9, \"impactScore\": 6.4, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2019-03-14T20:29:00.850",
"references": "[{\"url\": \"https://security.netapp.com/advisory/ntap-20190318-0001/\", \"source\": \"secure@intel.com\"}, {\"url\": \"https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03914en_us\", \"source\": \"secure@intel.com\"}, {\"url\": \"https://www.intel.com/content/www/us/en/security-center/advisory/INTEL-SA-00185.html\", \"source\": \"secure@intel.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://security.netapp.com/advisory/ntap-20190318-0001/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}, {\"url\": \"https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03914en_us\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}, {\"url\": \"https://www.intel.com/content/www/us/en/security-center/advisory/INTEL-SA-00185.html\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
"sourceIdentifier": "secure@intel.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-119\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2018-12208\",\"sourceIdentifier\":\"secure@intel.com\",\"published\":\"2019-03-14T20:29:00.850\",\"lastModified\":\"2024-11-21T03:44:46.920\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Buffer overflow in HECI subsystem in Intel(R) CSME before versions 11.8.60, 11.11.60, 11.22.60 or 12.0.20 and Intel(R) TXE version before 3.1.60 or 4.0.10, or Intel(R) Server Platform Services before version 5.00.04.012 may allow an unauthenticated user to potentially execute arbitrary code via physical access.\"},{\"lang\":\"es\",\"value\":\"Desbordamiento de b\u00fafer en el subsistema HECI de Intel(R) CSME, en versiones anteriores a las 11.8.60, 11.11.60, 11.22.60 o 12.0.20; o Intel (R) TXE, en versiones anteriores a la 3.1.60 o 4.0.10; o Intel(R) Server Platform Services en versiones anteriores a la 5.00.04.012 podr\u00eda permitir que un usuario no autenticado pueda ejecutar c\u00f3digo arbitrario mediante acceso f\u00edsico.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H\",\"baseScore\":7.6,\"baseSeverity\":\"HIGH\",\"attackVector\":\"PHYSICAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":0.9,\"impactScore\":6.0}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":4.6,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":3.9,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-119\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:intel:converged_security_management_engine_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"11.0\",\"versionEndExcluding\":\"11.8.60\",\"matchCriteriaId\":\"89FAC2D9-E921-4F45-B786-0902B310C2A3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:intel:converged_security_management_engine_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"11.10\",\"versionEndExcluding\":\"11.11.60\",\"matchCriteriaId\":\"EB85F0E9-95F9-452C-AAAF-0C8CCCE76C59\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:intel:converged_security_management_engine_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"11.20\",\"versionEndExcluding\":\"11.22.60\",\"matchCriteriaId\":\"3A44D8E6-445C-475D-BB1A-75C03AEE940B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:intel:converged_security_management_engine_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"12.0.0\",\"versionEndExcluding\":\"12.0.20\",\"matchCriteriaId\":\"91671FB7-F021-4781-9CBD-E7B66727B747\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:intel:server_platform_services_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"5.00.04.012\",\"matchCriteriaId\":\"7202A001-9A4F-4E3D-8B61-9DB27638A7AD\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:intel:trusted_execution_engine_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"3.0\",\"versionEndExcluding\":\"3.1.60\",\"matchCriteriaId\":\"3029FF22-3BD0-41A7-BBF9-E6183DF2BD31\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:intel:trusted_execution_engine_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"4.0\",\"versionEndExcluding\":\"4.0.10\",\"matchCriteriaId\":\"916A348F-144A-4A81-B93F-D3422A662D09\"}]}]}],\"references\":[{\"url\":\"https://security.netapp.com/advisory/ntap-20190318-0001/\",\"source\":\"secure@intel.com\"},{\"url\":\"https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03914en_us\",\"source\":\"secure@intel.com\"},{\"url\":\"https://www.intel.com/content/www/us/en/security-center/advisory/INTEL-SA-00185.html\",\"source\":\"secure@intel.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://security.netapp.com/advisory/ntap-20190318-0001/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03914en_us\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://www.intel.com/content/www/us/en/security-center/advisory/INTEL-SA-00185.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…