CVE-2018-7239 (GCVE-0-2018-7239)
Vulnerability from cvelistv5 – Published: 2018-03-09 23:00 – Updated: 2024-09-16 23:21
VLAI
Summary
A DLL hijacking vulnerability exists in Schneider Electric's SoMove Software and associated DTM software components in all versions prior to 2.6.2 which could allow an attacker to execute arbitrary code.
Severity
7.8 (High)
CWE
- DLL Hijacking
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://ics-cert.us-cert.gov/advisories/ICSA-18-065-02 | x_refsource_MISC |
| https://www.schneider-electric.com/en/download/do… | x_refsource_CONFIRM |
| http://www.securityfocus.com/bid/103338 | vdb-entryx_refsource_BID |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric SE | SoMove |
Affected:
n/a
|
Date Public
2018-03-01 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:24:11.489Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-065-02"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-060-01/"
},
{
"name": "103338",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/103338"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SoMove",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2018-03-01T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A DLL hijacking vulnerability exists in Schneider Electric\u0027s SoMove Software and associated DTM software components in all versions prior to 2.6.2 which could allow an attacker to execute arbitrary code."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "DLL Hijacking",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-03-12T16:57:01.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-065-02"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-060-01/"
},
{
"name": "103338",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/103338"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"DATE_PUBLIC": "2018-03-01T00:00:00",
"ID": "CVE-2018-7239",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SoMove",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A DLL hijacking vulnerability exists in Schneider Electric\u0027s SoMove Software and associated DTM software components in all versions prior to 2.6.2 which could allow an attacker to execute arbitrary code."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "DLL Hijacking"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-065-02",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-065-02"
},
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2018-060-01/",
"refsource": "CONFIRM",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2018-060-01/"
},
{
"name": "103338",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/103338"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7239",
"datePublished": "2018-03-09T23:00:00.000Z",
"dateReserved": "2018-02-19T00:00:00.000Z",
"dateUpdated": "2024-09-16T23:21:36.267Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2018-7239",
"date": "2026-06-01",
"epss": "0.00457",
"percentile": "0.64205"
},
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:atv_lift_dtm:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"12.7.0\", \"matchCriteriaId\": \"8F0F8212-5CC6-4EB7-9F37-4587FC849A54\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:atv12_dtm:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"12.7.0\", \"matchCriteriaId\": \"70DDF782-E80B-41A6-88F0-52D3BCCD0BE6\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:atv212_dtm:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"12.7.0\", \"matchCriteriaId\": \"8A9E382F-DBB4-4B24-81C7-EE33B5248935\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:atv31_dtm:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"12.7.0\", \"matchCriteriaId\": \"2429408E-48C9-4F97-A918-4DDECF6A7AB2\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:atv312_dtm:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"12.7.0\", \"matchCriteriaId\": \"44D79762-E0D3-4DB9-8DD8-AE6A93953411\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:atv32_dtm:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"12.7.0\", \"matchCriteriaId\": \"DC70CB2D-2AA8-40EC-97BC-0527D5F100ED\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:atv320_dtm:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.1.6\", \"matchCriteriaId\": \"1D1862C8-5571-4DAC-B9F0-96DC3F2F846F\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:atv340_dtm:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.2.3\", \"matchCriteriaId\": \"CB77B51C-CA0B-4C6E-91D2-41C450C6214E\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:atv600_dtm:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.8.0\", \"matchCriteriaId\": \"FE8C39E7-A682-4453-945F-D1DFC9418A7C\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:atv61_dtm:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"12.7.0\", \"matchCriteriaId\": \"988EB546-BB63-4DEF-800E-5C5A3C796163\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:atv71_dtm:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"12.7.0\", \"matchCriteriaId\": \"848353C2-B49E-4B88-A57A-C783BF47C84C\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:atv900_dtm:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.3.5\", \"matchCriteriaId\": \"3BA8B718-4947-41FE-9DDC-DA3AB85992B3\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:somove:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"2.6.2\", \"matchCriteriaId\": \"AD8AD349-3536-4244-8D10-D860A5A7F1FF\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"A DLL hijacking vulnerability exists in Schneider Electric\u0027s SoMove Software and associated DTM software components in all versions prior to 2.6.2 which could allow an attacker to execute arbitrary code.\"}, {\"lang\": \"es\", \"value\": \"Existe una vulnerabilidad de secuestro de DLL en SoMove Software de Schneider Electric y en los componentes de software DTM asociados, en todas las versiones anteriores a la 2.6.2. Esto podr\\u00eda permitir que un atacante ejecute c\\u00f3digo arbitrario.\"}]",
"id": "CVE-2018-7239",
"lastModified": "2024-11-21T04:11:51.273",
"metrics": "{\"cvssMetricV30\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\", \"baseScore\": 7.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:N/C:P/I:P/A:P\", \"baseScore\": 6.8, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 8.6, \"impactScore\": 6.4, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": true}]}",
"published": "2018-03-09T23:29:00.967",
"references": "[{\"url\": \"http://www.securityfocus.com/bid/103338\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://ics-cert.us-cert.gov/advisories/ICSA-18-065-02\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}, {\"url\": \"https://www.schneider-electric.com/en/download/document/SEVD-2018-060-01/\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"http://www.securityfocus.com/bid/103338\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://ics-cert.us-cert.gov/advisories/ICSA-18-065-02\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}, {\"url\": \"https://www.schneider-electric.com/en/download/document/SEVD-2018-060-01/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-426\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2018-7239\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2018-03-09T23:29:00.967\",\"lastModified\":\"2024-11-21T04:11:51.273\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A DLL hijacking vulnerability exists in Schneider Electric\u0027s SoMove Software and associated DTM software components in all versions prior to 2.6.2 which could allow an attacker to execute arbitrary code.\"},{\"lang\":\"es\",\"value\":\"Existe una vulnerabilidad de secuestro de DLL en SoMove Software de Schneider Electric y en los componentes de software DTM asociados, en todas las versiones anteriores a la 2.6.2. Esto podr\u00eda permitir que un atacante ejecute c\u00f3digo arbitrario.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:P\",\"baseScore\":6.8,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-426\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:atv_lift_dtm:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"12.7.0\",\"matchCriteriaId\":\"8F0F8212-5CC6-4EB7-9F37-4587FC849A54\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:atv12_dtm:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"12.7.0\",\"matchCriteriaId\":\"70DDF782-E80B-41A6-88F0-52D3BCCD0BE6\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:atv212_dtm:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"12.7.0\",\"matchCriteriaId\":\"8A9E382F-DBB4-4B24-81C7-EE33B5248935\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:atv31_dtm:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"12.7.0\",\"matchCriteriaId\":\"2429408E-48C9-4F97-A918-4DDECF6A7AB2\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:atv312_dtm:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"12.7.0\",\"matchCriteriaId\":\"44D79762-E0D3-4DB9-8DD8-AE6A93953411\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:atv32_dtm:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"12.7.0\",\"matchCriteriaId\":\"DC70CB2D-2AA8-40EC-97BC-0527D5F100ED\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:atv320_dtm:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.1.6\",\"matchCriteriaId\":\"1D1862C8-5571-4DAC-B9F0-96DC3F2F846F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:atv340_dtm:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.2.3\",\"matchCriteriaId\":\"CB77B51C-CA0B-4C6E-91D2-41C450C6214E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:atv600_dtm:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.8.0\",\"matchCriteriaId\":\"FE8C39E7-A682-4453-945F-D1DFC9418A7C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:atv61_dtm:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"12.7.0\",\"matchCriteriaId\":\"988EB546-BB63-4DEF-800E-5C5A3C796163\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:atv71_dtm:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"12.7.0\",\"matchCriteriaId\":\"848353C2-B49E-4B88-A57A-C783BF47C84C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:atv900_dtm:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.3.5\",\"matchCriteriaId\":\"3BA8B718-4947-41FE-9DDC-DA3AB85992B3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:somove:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.6.2\",\"matchCriteriaId\":\"AD8AD349-3536-4244-8D10-D860A5A7F1FF\"}]}]}],\"references\":[{\"url\":\"http://www.securityfocus.com/bid/103338\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-18-065-02\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.schneider-electric.com/en/download/document/SEVD-2018-060-01/\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/103338\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-18-065-02\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.schneider-electric.com/en/download/document/SEVD-2018-060-01/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…