cve-2019-12690
Vulnerability from cvelistv5
Published
2019-10-02 19:06
Modified
2024-09-16 19:30
Severity
Summary
Cisco Firepower Management Center Command Injection Vulnerability
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T23:24:39.187Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "20191002 Cisco Firepower Management Center Command Injection Vulnerability",
            "tags": [
              "vendor-advisory",
              "x_refsource_CISCO",
              "x_transferred"
            ],
            "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191002-fmc-com-inj"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Cisco Firepower Management Center",
          "vendor": "Cisco",
          "versions": [
            {
              "lessThan": "n/a",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2019-10-02T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability in the web UI of the Cisco Firepower Management Center (FMC) could allow an authenticated, remote attacker to inject arbitrary commands that are executed with the privileges of the root user of the underlying operating system. The vulnerability is due to insufficient validation of user-supplied input to the web UI. An attacker could exploit this vulnerability by submitting crafted input in the web UI. A successful exploit could allow an attacker to execute arbitrary commands on the device with full root privileges."
        }
      ],
      "exploits": [
        {
          "lang": "en",
          "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-10-02T19:06:45",
        "orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
        "shortName": "cisco"
      },
      "references": [
        {
          "name": "20191002 Cisco Firepower Management Center Command Injection Vulnerability",
          "tags": [
            "vendor-advisory",
            "x_refsource_CISCO"
          ],
          "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191002-fmc-com-inj"
        }
      ],
      "source": {
        "advisory": "cisco-sa-20191002-fmc-com-inj",
        "defect": [
          [
            "CSCvh03962"
          ]
        ],
        "discovery": "INTERNAL"
      },
      "title": "Cisco Firepower Management Center Command Injection Vulnerability",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@cisco.com",
          "DATE_PUBLIC": "2019-10-02T16:00:00-0700",
          "ID": "CVE-2019-12690",
          "STATE": "PUBLIC",
          "TITLE": "Cisco Firepower Management Center Command Injection Vulnerability"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Cisco Firepower Management Center",
                      "version": {
                        "version_data": [
                          {
                            "affected": "\u003c",
                            "version_affected": "\u003c",
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Cisco"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability in the web UI of the Cisco Firepower Management Center (FMC) could allow an authenticated, remote attacker to inject arbitrary commands that are executed with the privileges of the root user of the underlying operating system. The vulnerability is due to insufficient validation of user-supplied input to the web UI. An attacker could exploit this vulnerability by submitting crafted input in the web UI. A successful exploit could allow an attacker to execute arbitrary commands on the device with full root privileges."
            }
          ]
        },
        "exploit": [
          {
            "lang": "en",
            "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
          }
        ],
        "impact": {
          "cvss": {
            "baseScore": "7.2",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-78"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "20191002 Cisco Firepower Management Center Command Injection Vulnerability",
              "refsource": "CISCO",
              "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191002-fmc-com-inj"
            }
          ]
        },
        "source": {
          "advisory": "cisco-sa-20191002-fmc-com-inj",
          "defect": [
            [
              "CSCvh03962"
            ]
          ],
          "discovery": "INTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
    "assignerShortName": "cisco",
    "cveId": "CVE-2019-12690",
    "datePublished": "2019-10-02T19:06:45.492396Z",
    "dateReserved": "2019-06-04T00:00:00",
    "dateUpdated": "2024-09-16T19:30:19.088Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2019-12690\",\"sourceIdentifier\":\"ykramarz@cisco.com\",\"published\":\"2019-10-02T19:15:13.203\",\"lastModified\":\"2019-10-10T17:17:05.330\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability in the web UI of the Cisco Firepower Management Center (FMC) could allow an authenticated, remote attacker to inject arbitrary commands that are executed with the privileges of the root user of the underlying operating system. The vulnerability is due to insufficient validation of user-supplied input to the web UI. An attacker could exploit this vulnerability by submitting crafted input in the web UI. A successful exploit could allow an attacker to execute arbitrary commands on the device with full root privileges.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad en la Interfaz de Usuario web de Cisco Firepower Management Center (FMC), podr\u00eda permitir a un atacante remoto autenticado inyectar comandos arbitrarios que son ejecutados con los privilegios del usuario root del sistema operativo subyacente. La vulnerabilidad es debido a una comprobaci\u00f3n insuficiente de la entrada suministrada por el usuario en la Interfaz de Usuario web. Un atacante podr\u00eda explotar esta vulnerabilidad mediante el env\u00edo de una entrada dise\u00f1ada en la Interfaz de Usuario web. Una explotaci\u00f3n con \u00e9xito podr\u00eda permitir a un atacante ejecutar comandos arbitrarios en el dispositivo con todos los privilegios de root.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.2,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":5.9}],\"cvssMetricV30\":[{\"source\":\"ykramarz@cisco.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.2,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:C/I:C/A:C\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\",\"baseScore\":9.0},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":8.0,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]},{\"source\":\"ykramarz@cisco.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:firepower_management_center:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"6.3.0.5\",\"matchCriteriaId\":\"227DF268-DDA0-4888-A0CE-478E41E9E0DF\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:firepower_management_center:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"6.4.0\",\"versionEndExcluding\":\"6.4.0.4\",\"matchCriteriaId\":\"91F74AF1-E66C-4CE7-A69B-CC2505718C01\"}]}]}],\"references\":[{\"url\":\"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191002-fmc-com-inj\",\"source\":\"ykramarz@cisco.com\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...