Summary
Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4. The authentication mechanism on affected systems does not provide a sufficient level of protection against unauthorized configuration changes. Primary operations, namely turning the cooling unit on and off and setting the temperature set point, can be modified without authentication.
Severity
No CVSS data available.
CWE
- CWE-306 - MISSING AUTHENTICATION FOR CRITICAL FUNCTION CWE-306
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.us-cert.gov/ics/advisories/icsa-19-297-01 | x_refsource_MISC |
| http://seclists.org/fulldisclosure/2019/Oct/46 | mailing-listx_refsource_FULLDISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Rittal Chiller SK 3232-Series |
Affected:
Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T23:57:39.519Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-297-01"
},
{
"name": "20191031 [RT-SA-2019-014] Unauthenticated Access to Modbus Interface in Carel pCOWeb HVAC",
"tags": [
"mailing-list",
"x_refsource_FULLDISC",
"x_transferred"
],
"url": "http://seclists.org/fulldisclosure/2019/Oct/46"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Rittal Chiller SK 3232-Series",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 \u2013 B1.2.4"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 \u2013 B1.2.4. The authentication mechanism on affected systems does not provide a sufficient level of protection against unauthorized configuration changes. Primary operations, namely turning the cooling unit on and off and setting the temperature set point, can be modified without authentication."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "MISSING AUTHENTICATION FOR CRITICAL FUNCTION CWE-306",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-11-01T02:06:25.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-297-01"
},
{
"name": "20191031 [RT-SA-2019-014] Unauthenticated Access to Modbus Interface in Carel pCOWeb HVAC",
"tags": [
"mailing-list",
"x_refsource_FULLDISC"
],
"url": "http://seclists.org/fulldisclosure/2019/Oct/46"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2019-13549",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Rittal Chiller SK 3232-Series",
"version": {
"version_data": [
{
"version_value": "Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 \u2013 B1.2.4"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 \u2013 B1.2.4. The authentication mechanism on affected systems does not provide a sufficient level of protection against unauthorized configuration changes. Primary operations, namely turning the cooling unit on and off and setting the temperature set point, can be modified without authentication."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "MISSING AUTHENTICATION FOR CRITICAL FUNCTION CWE-306"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-19-297-01",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-297-01"
},
{
"name": "20191031 [RT-SA-2019-014] Unauthenticated Access to Modbus Interface in Carel pCOWeb HVAC",
"refsource": "FULLDISC",
"url": "http://seclists.org/fulldisclosure/2019/Oct/46"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2019-13549",
"datePublished": "2019-10-25T17:43:09.000Z",
"dateReserved": "2019-07-11T00:00:00.000Z",
"dateUpdated": "2024-08-04T23:57:39.519Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2019-13549",
"date": "2026-05-28",
"epss": "0.00343",
"percentile": "0.57084"
},
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:carel:pcoweb_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"a1.5.3\", \"versionEndIncluding\": \"b1.2.4\", \"matchCriteriaId\": \"6B7B4C31-67E0-488A-9297-B8E8E158DC3E\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:rittal:chiller_sk_3232:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"3FAC3FD5-429B-48BF-B519-47CAD3E718C0\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 \\u2013 B1.2.4. The authentication mechanism on affected systems does not provide a sufficient level of protection against unauthorized configuration changes. Primary operations, namely turning the cooling unit on and off and setting the temperature set point, can be modified without authentication.\"}, {\"lang\": \"es\", \"value\": \"El Interfaz web Rittal Chiller SK 3232-Series seg\\u00fan el firmware Carel pCOWeb A1.5.3 - B1.2.4. El mecanismo de autenticaci\\u00f3n en los sistemas afectados no proporciona un nivel suficiente de protecci\\u00f3n contra cambios de configuraci\\u00f3n no autorizados. Las operaciones primarias, a saber, encender y apagar la unidad de enfriamiento y establecer el punto de ajuste de temperatura, se pueden modificar sin autenticaci\\u00f3n.\"}]",
"id": "CVE-2019-13549",
"lastModified": "2024-11-21T04:25:07.587",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.6}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:N/I:P/A:N\", \"baseScore\": 5.0, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 10.0, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2019-10-25T18:15:10.880",
"references": "[{\"url\": \"http://seclists.org/fulldisclosure/2019/Oct/46\", \"source\": \"ics-cert@hq.dhs.gov\"}, {\"url\": \"https://www.us-cert.gov/ics/advisories/icsa-19-297-01\", \"source\": \"ics-cert@hq.dhs.gov\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}, {\"url\": \"http://seclists.org/fulldisclosure/2019/Oct/46\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}, {\"url\": \"https://www.us-cert.gov/ics/advisories/icsa-19-297-01\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}]",
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"ics-cert@hq.dhs.gov\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-306\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-306\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2019-13549\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2019-10-25T18:15:10.880\",\"lastModified\":\"2024-11-21T04:25:07.587\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 \u2013 B1.2.4. The authentication mechanism on affected systems does not provide a sufficient level of protection against unauthorized configuration changes. Primary operations, namely turning the cooling unit on and off and setting the temperature set point, can be modified without authentication.\"},{\"lang\":\"es\",\"value\":\"El Interfaz web Rittal Chiller SK 3232-Series seg\u00fan el firmware Carel pCOWeb A1.5.3 - B1.2.4. El mecanismo de autenticaci\u00f3n en los sistemas afectados no proporciona un nivel suficiente de protecci\u00f3n contra cambios de configuraci\u00f3n no autorizados. Las operaciones primarias, a saber, encender y apagar la unidad de enfriamiento y establecer el punto de ajuste de temperatura, se pueden modificar sin autenticaci\u00f3n.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:P/A:N\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-306\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-306\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:carel:pcoweb_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"a1.5.3\",\"versionEndIncluding\":\"b1.2.4\",\"matchCriteriaId\":\"6B7B4C31-67E0-488A-9297-B8E8E158DC3E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:rittal:chiller_sk_3232:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3FAC3FD5-429B-48BF-B519-47CAD3E718C0\"}]}]}],\"references\":[{\"url\":\"http://seclists.org/fulldisclosure/2019/Oct/46\",\"source\":\"ics-cert@hq.dhs.gov\"},{\"url\":\"https://www.us-cert.gov/ics/advisories/icsa-19-297-01\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"http://seclists.org/fulldisclosure/2019/Oct/46\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://www.us-cert.gov/ics/advisories/icsa-19-297-01\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}"
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…