CVE-2019-8963 (GCVE-0-2019-8963)
Vulnerability from cvelistv5 – Published: 2023-03-29 00:00 – Updated: 2025-02-19 17:19- n/a
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T21:31:37.566Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://community.flexera.com/t5/FlexNet-Publisher-Knowledge-Base/CVE-2019-8963-Remediated-in-FlexNet-Publisher/ta-p/148768"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2019-8963",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-19T17:17:48.356532Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "CWE-noinfo Not enough information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-19T17:19:18.638Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A Denial of Service (DoS) vulnerability was discovered in FlexNet Publisher\u0027s lmadmin 11.16.5, when doing a crafted POST request on lmadmin using the web-based tool."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-03-29T00:00:00.000Z",
"orgId": "44d08088-2bea-4760-83a6-1e9be26b15ab",
"shortName": "flexera"
},
"references": [
{
"url": "https://community.flexera.com/t5/FlexNet-Publisher-Knowledge-Base/CVE-2019-8963-Remediated-in-FlexNet-Publisher/ta-p/148768"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "44d08088-2bea-4760-83a6-1e9be26b15ab",
"assignerShortName": "flexera",
"cveId": "CVE-2019-8963",
"datePublished": "2023-03-29T00:00:00.000Z",
"dateReserved": "2019-02-20T00:00:00.000Z",
"dateUpdated": "2025-02-19T17:19:18.638Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2019-8963",
"date": "2026-05-25",
"epss": "0.00389",
"percentile": "0.60102"
},
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:flexera:flexnet_publisher:11.16.5:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"392E1CF7-00A2-4E24-90AC-48D207D680E2\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"A Denial of Service (DoS) vulnerability was discovered in FlexNet Publisher\u0027s lmadmin 11.16.5, when doing a crafted POST request on lmadmin using the web-based tool.\"}]",
"id": "CVE-2019-8963",
"lastModified": "2024-11-21T04:50:44.573",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.6}]}",
"published": "2023-03-29T21:15:07.753",
"references": "[{\"url\": \"https://community.flexera.com/t5/FlexNet-Publisher-Knowledge-Base/CVE-2019-8963-Remediated-in-FlexNet-Publisher/ta-p/148768\", \"source\": \"PSIRT-CNA@flexerasoftware.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://community.flexera.com/t5/FlexNet-Publisher-Knowledge-Base/CVE-2019-8963-Remediated-in-FlexNet-Publisher/ta-p/148768\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
"sourceIdentifier": "PSIRT-CNA@flexerasoftware.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"NVD-CWE-noinfo\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2019-8963\",\"sourceIdentifier\":\"PSIRT-CNA@flexerasoftware.com\",\"published\":\"2023-03-29T21:15:07.753\",\"lastModified\":\"2025-02-19T18:15:20.310\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A Denial of Service (DoS) vulnerability was discovered in FlexNet Publisher\u0027s lmadmin 11.16.5, when doing a crafted POST request on lmadmin using the web-based tool.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:flexera:flexnet_publisher:11.16.5:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"392E1CF7-00A2-4E24-90AC-48D207D680E2\"}]}]}],\"references\":[{\"url\":\"https://community.flexera.com/t5/FlexNet-Publisher-Knowledge-Base/CVE-2019-8963-Remediated-in-FlexNet-Publisher/ta-p/148768\",\"source\":\"PSIRT-CNA@flexerasoftware.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://community.flexera.com/t5/FlexNet-Publisher-Knowledge-Base/CVE-2019-8963-Remediated-in-FlexNet-Publisher/ta-p/148768\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://community.flexera.com/t5/FlexNet-Publisher-Knowledge-Base/CVE-2019-8963-Remediated-in-FlexNet-Publisher/ta-p/148768\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-04T21:31:37.566Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.5, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"NONE\"}}, {\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2019-8963\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-02-19T17:17:48.356532Z\"}}}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"description\": \"CWE-noinfo Not enough information\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-02-19T17:19:12.963Z\"}}], \"cna\": {\"affected\": [{\"vendor\": \"n/a\", \"product\": \"n/a\", \"versions\": [{\"status\": \"affected\", \"version\": \"n/a\"}]}], \"references\": [{\"url\": \"https://community.flexera.com/t5/FlexNet-Publisher-Knowledge-Base/CVE-2019-8963-Remediated-in-FlexNet-Publisher/ta-p/148768\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A Denial of Service (DoS) vulnerability was discovered in FlexNet Publisher\u0027s lmadmin 11.16.5, when doing a crafted POST request on lmadmin using the web-based tool.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"text\", \"description\": \"n/a\"}]}], \"providerMetadata\": {\"orgId\": \"44d08088-2bea-4760-83a6-1e9be26b15ab\", \"shortName\": \"flexera\", \"dateUpdated\": \"2023-03-29T00:00:00.000Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2019-8963\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-02-19T17:19:18.638Z\", \"dateReserved\": \"2019-02-20T00:00:00.000Z\", \"assignerOrgId\": \"44d08088-2bea-4760-83a6-1e9be26b15ab\", \"datePublished\": \"2023-03-29T00:00:00.000Z\", \"assignerShortName\": \"flexera\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
CERTFR-2022-AVI-017
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| N/A | N/A | Easergy P5, versions antérieures à 01.401.101, se référer aux informations fournies par l'éditeur pour appliquer les mesures de contournement | ||
| N/A | N/A | ConneXium Tofino Firewall TCSEFEA23F3F20 et 21, toutes versions. Ces produits ne sont plus maintenus par l'éditeur qui incite fortement à mettre à jour vers la gamme TCSEFA23F3F22 | ||
| Schneider Electric | N/A | ConneXium Tofino OPC-LSM TCSEFM0000, versions antérieures à 03.23 | ||
| N/A | N/A | CODESYS V3, vérifier l'avis SEVD-2022-011-06 pour identifier les périphériques utilisant ce système d'exploitation et appliquer les mesures de contournement suggérées par l'éditeur | ||
| N/A | N/A | Easergy T300, versions antérieures à 2.7.1 | ||
| Schneider Electric | N/A | Easergy P3, versions antérieures à 30.205, se référer aux informations fournies par l'éditeur pour appliquer les mesures de contournement | ||
| Schneider Electric | N/A | EcoStruxure Power Monitoring Expert 2020, versions antérieures à 2020 CU3 sans le composant Floating License Manager 2.7 | ||
| Schneider Electric | N/A | ConneXium Tofino Firewall TCSEFEA23F3F22, versions antérieures à 03.23 | ||
| Schneider Electric | Modicon M340 | Modicon M340 Quantum et Premium Quantum CPUs, vérifier l'avis SEVD-2022-011-01 pour identifier les autres systèmes Modicon vulnérables et appliquer les mesures de contournement suggérées par l'éditeur | ||
| Schneider Electric | N/A | EcoStruxure Power Monitoring Expert 9.0, toutes versions. Ces produits ne sont plus maintenus par l'éditeur qui incite fortement à mettre à jour vers la gamme Power Monitoring Expert 2021 |
| Title | Publication Time | Tags | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Easergy P5, versions ant\u00e9rieures \u00e0 01.401.101, se r\u00e9f\u00e9rer aux informations fournies par l\u0027\u00e9diteur pour appliquer les mesures de contournement",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "ConneXium Tofino Firewall TCSEFEA23F3F20 et 21, toutes versions. Ces produits ne sont plus maintenus par l\u0027\u00e9diteur qui incite fortement \u00e0 mettre \u00e0 jour vers la gamme TCSEFA23F3F22",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "ConneXium Tofino OPC-LSM TCSEFM0000, versions ant\u00e9rieures \u00e0 03.23",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "CODESYS V3, v\u00e9rifier l\u0027avis SEVD-2022-011-06 pour identifier les p\u00e9riph\u00e9riques utilisant ce syst\u00e8me d\u0027exploitation et appliquer les mesures de contournement sugg\u00e9r\u00e9es par l\u0027\u00e9diteur",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Easergy T300, versions ant\u00e9rieures \u00e0 2.7.1",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Easergy P3, versions ant\u00e9rieures \u00e0 30.205, se r\u00e9f\u00e9rer aux informations fournies par l\u0027\u00e9diteur pour appliquer les mesures de contournement",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Monitoring Expert 2020, versions ant\u00e9rieures \u00e0 2020 CU3 sans le composant Floating License Manager 2.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "ConneXium Tofino Firewall TCSEFEA23F3F22, versions ant\u00e9rieures \u00e0 03.23",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M340 Quantum et Premium Quantum CPUs, v\u00e9rifier l\u0027avis SEVD-2022-011-01 pour identifier les autres syst\u00e8mes Modicon vuln\u00e9rables et appliquer les mesures de contournement sugg\u00e9r\u00e9es par l\u0027\u00e9diteur",
"product": {
"name": "Modicon M340",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Monitoring Expert 9.0, toutes versions. Ces produits ne sont plus maintenus par l\u0027\u00e9diteur qui incite fortement \u00e0 mettre \u00e0 jour vers la gamme Power Monitoring Expert 2021",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2022-22723",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22723"
},
{
"name": "CVE-2021-21869",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21869"
},
{
"name": "CVE-2021-21866",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21866"
},
{
"name": "CVE-2021-30066",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-30066"
},
{
"name": "CVE-2021-30064",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-30064"
},
{
"name": "CVE-2022-22724",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22724"
},
{
"name": "CVE-2019-8963",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8963"
},
{
"name": "CVE-2021-30063",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-30063"
},
{
"name": "CVE-2021-30061",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-30061"
},
{
"name": "CVE-2021-21863",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21863"
},
{
"name": "CVE-2022-22722",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22722"
},
{
"name": "CVE-2021-21865",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21865"
},
{
"name": "CVE-2020-7534",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7534"
},
{
"name": "CVE-2021-21867",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21867"
},
{
"name": "CVE-2022-22804",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22804"
},
{
"name": "CVE-2021-30062",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-30062"
},
{
"name": "CVE-2022-22726",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22726"
},
{
"name": "CVE-2022-22725",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22725"
},
{
"name": "CVE-2021-29241",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-29241"
},
{
"name": "CVE-2020-8597",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-8597"
},
{
"name": "CVE-2021-29240",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-29240"
},
{
"name": "CVE-2022-22727",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22727"
},
{
"name": "CVE-2021-21864",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21864"
},
{
"name": "CVE-2021-21868",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21868"
},
{
"name": "CVE-2021-30065",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-30065"
},
{
"name": "CVE-2021-33485",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-33485"
}
],
"links": [],
"reference": "CERTFR-2022-AVI-017",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2022-01-11T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Injection de code indirecte \u00e0 distance (XSS)"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Ex\u00e9cution de code arbitraire"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire, un d\u00e9ni de service \u00e0\ndistance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-011-07 du 11 janvier 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-07"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-011-03 du 11 janvier 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-03"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-011-04 du 11 janvier 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-04"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-011-01 du 11 janvier 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-01"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-011-02 du 11 janvier 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-02"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-011-05 du 11 janvier 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-011-06 du 11 janvier 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-06"
}
]
}
CERTFR-2022-AVI-017
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| N/A | N/A | Easergy P5, versions antérieures à 01.401.101, se référer aux informations fournies par l'éditeur pour appliquer les mesures de contournement | ||
| N/A | N/A | ConneXium Tofino Firewall TCSEFEA23F3F20 et 21, toutes versions. Ces produits ne sont plus maintenus par l'éditeur qui incite fortement à mettre à jour vers la gamme TCSEFA23F3F22 | ||
| Schneider Electric | N/A | ConneXium Tofino OPC-LSM TCSEFM0000, versions antérieures à 03.23 | ||
| N/A | N/A | CODESYS V3, vérifier l'avis SEVD-2022-011-06 pour identifier les périphériques utilisant ce système d'exploitation et appliquer les mesures de contournement suggérées par l'éditeur | ||
| N/A | N/A | Easergy T300, versions antérieures à 2.7.1 | ||
| Schneider Electric | N/A | Easergy P3, versions antérieures à 30.205, se référer aux informations fournies par l'éditeur pour appliquer les mesures de contournement | ||
| Schneider Electric | N/A | EcoStruxure Power Monitoring Expert 2020, versions antérieures à 2020 CU3 sans le composant Floating License Manager 2.7 | ||
| Schneider Electric | N/A | ConneXium Tofino Firewall TCSEFEA23F3F22, versions antérieures à 03.23 | ||
| Schneider Electric | Modicon M340 | Modicon M340 Quantum et Premium Quantum CPUs, vérifier l'avis SEVD-2022-011-01 pour identifier les autres systèmes Modicon vulnérables et appliquer les mesures de contournement suggérées par l'éditeur | ||
| Schneider Electric | N/A | EcoStruxure Power Monitoring Expert 9.0, toutes versions. Ces produits ne sont plus maintenus par l'éditeur qui incite fortement à mettre à jour vers la gamme Power Monitoring Expert 2021 |
| Title | Publication Time | Tags | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Easergy P5, versions ant\u00e9rieures \u00e0 01.401.101, se r\u00e9f\u00e9rer aux informations fournies par l\u0027\u00e9diteur pour appliquer les mesures de contournement",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "ConneXium Tofino Firewall TCSEFEA23F3F20 et 21, toutes versions. Ces produits ne sont plus maintenus par l\u0027\u00e9diteur qui incite fortement \u00e0 mettre \u00e0 jour vers la gamme TCSEFA23F3F22",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "ConneXium Tofino OPC-LSM TCSEFM0000, versions ant\u00e9rieures \u00e0 03.23",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "CODESYS V3, v\u00e9rifier l\u0027avis SEVD-2022-011-06 pour identifier les p\u00e9riph\u00e9riques utilisant ce syst\u00e8me d\u0027exploitation et appliquer les mesures de contournement sugg\u00e9r\u00e9es par l\u0027\u00e9diteur",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Easergy T300, versions ant\u00e9rieures \u00e0 2.7.1",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Easergy P3, versions ant\u00e9rieures \u00e0 30.205, se r\u00e9f\u00e9rer aux informations fournies par l\u0027\u00e9diteur pour appliquer les mesures de contournement",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Monitoring Expert 2020, versions ant\u00e9rieures \u00e0 2020 CU3 sans le composant Floating License Manager 2.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "ConneXium Tofino Firewall TCSEFEA23F3F22, versions ant\u00e9rieures \u00e0 03.23",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M340 Quantum et Premium Quantum CPUs, v\u00e9rifier l\u0027avis SEVD-2022-011-01 pour identifier les autres syst\u00e8mes Modicon vuln\u00e9rables et appliquer les mesures de contournement sugg\u00e9r\u00e9es par l\u0027\u00e9diteur",
"product": {
"name": "Modicon M340",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Power Monitoring Expert 9.0, toutes versions. Ces produits ne sont plus maintenus par l\u0027\u00e9diteur qui incite fortement \u00e0 mettre \u00e0 jour vers la gamme Power Monitoring Expert 2021",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2022-22723",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22723"
},
{
"name": "CVE-2021-21869",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21869"
},
{
"name": "CVE-2021-21866",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21866"
},
{
"name": "CVE-2021-30066",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-30066"
},
{
"name": "CVE-2021-30064",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-30064"
},
{
"name": "CVE-2022-22724",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22724"
},
{
"name": "CVE-2019-8963",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8963"
},
{
"name": "CVE-2021-30063",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-30063"
},
{
"name": "CVE-2021-30061",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-30061"
},
{
"name": "CVE-2021-21863",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21863"
},
{
"name": "CVE-2022-22722",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22722"
},
{
"name": "CVE-2021-21865",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21865"
},
{
"name": "CVE-2020-7534",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7534"
},
{
"name": "CVE-2021-21867",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21867"
},
{
"name": "CVE-2022-22804",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22804"
},
{
"name": "CVE-2021-30062",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-30062"
},
{
"name": "CVE-2022-22726",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22726"
},
{
"name": "CVE-2022-22725",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22725"
},
{
"name": "CVE-2021-29241",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-29241"
},
{
"name": "CVE-2020-8597",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-8597"
},
{
"name": "CVE-2021-29240",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-29240"
},
{
"name": "CVE-2022-22727",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22727"
},
{
"name": "CVE-2021-21864",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21864"
},
{
"name": "CVE-2021-21868",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-21868"
},
{
"name": "CVE-2021-30065",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-30065"
},
{
"name": "CVE-2021-33485",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-33485"
}
],
"links": [],
"reference": "CERTFR-2022-AVI-017",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2022-01-11T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Injection de code indirecte \u00e0 distance (XSS)"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Ex\u00e9cution de code arbitraire"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire, un d\u00e9ni de service \u00e0\ndistance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-011-07 du 11 janvier 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-07"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-011-03 du 11 janvier 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-03"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-011-04 du 11 janvier 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-04"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-011-01 du 11 janvier 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-01"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-011-02 du 11 janvier 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-02"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-011-05 du 11 janvier 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-05"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-011-06 du 11 janvier 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-06"
}
]
}
BDU:2023-02700
Vulnerability from fstec - Published: 01.06.2020{
"CVSS 2.0": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"CVSS 3.0": "AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"CVSS 4.0": null,
"remediation_\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": null,
"remediation_\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435": null,
"\u0412\u0435\u043d\u0434\u043e\u0440 \u041f\u041e": "Schneider Electric, Flexera Software",
"\u0412\u0435\u0440\u0441\u0438\u044f \u041f\u041e": "\u0434\u043e 2020 \u0432\u043a\u043b\u044e\u0447\u0438\u0442\u0435\u043b\u044c\u043d\u043e (EcoStruxure Power Monitoring Expert), \u0434\u043e 11.17.0 (FlexNet Publisher)",
"\u0412\u043e\u0437\u043c\u043e\u0436\u043d\u044b\u0435 \u043c\u0435\u0440\u044b \u043f\u043e \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044e": "\u0418\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438 \u0440\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0430\u0446\u0438\u0439: \n\u0414\u043b\u044f EcoStruxure Power Monitoring Expert:\nhttps://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-07\n\n\u0414\u043b\u044f FlexNet Publisher:\nhttps://community.flexera.com/t5/FlexNet-Publisher-Knowledge-Base/CVE-2019-8963-Remediated-in-FlexNet-Publisher/ta-p/148768",
"\u0414\u0430\u0442\u0430 \u0432\u044b\u044f\u0432\u043b\u0435\u043d\u0438\u044f": "01.06.2020",
"\u0414\u0430\u0442\u0430 \u043f\u043e\u0441\u043b\u0435\u0434\u043d\u0435\u0433\u043e \u043e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u044f": "22.05.2023",
"\u0414\u0430\u0442\u0430 \u043f\u0443\u0431\u043b\u0438\u043a\u0430\u0446\u0438\u0438": "22.05.2023",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": "BDU:2023-02700",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440\u044b \u0434\u0440\u0443\u0433\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c \u043e\u043f\u0438\u0441\u0430\u043d\u0438\u0439 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "CVE-2019-8963",
"\u0418\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f \u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0430",
"\u041a\u043b\u0430\u0441\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043a\u043e\u0434\u0430",
"\u041d\u0430\u0437\u0432\u0430\u043d\u0438\u0435 \u041f\u041e": "EcoStruxure Power Monitoring Expert, FlexNet Publisher",
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u041e\u0421 \u0438 \u0442\u0438\u043f \u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u043e\u0439 \u043f\u043b\u0430\u0442\u0444\u043e\u0440\u043c\u044b": null,
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u0434\u0438\u0441\u043f\u0435\u0442\u0447\u0435\u0440\u0430 \u0441\u0435\u0440\u0432\u0435\u0440\u043e\u0432 \u043b\u0438\u0446\u0435\u043d\u0437\u0438\u0439 lmadmin FlexNet Publisher, \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044e\u0449\u0430\u044f \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e \u0432\u044b\u0437\u0432\u0430\u0442\u044c \u043e\u0442\u043a\u0430\u0437 \u0432 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0438",
"\u041d\u0430\u043b\u0438\u0447\u0438\u0435 \u044d\u043a\u0441\u043f\u043b\u043e\u0439\u0442\u0430": "\u0414\u0430\u043d\u043d\u044b\u0435 \u0443\u0442\u043e\u0447\u043d\u044f\u044e\u0442\u0441\u044f",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "\u041d\u0435\u043a\u043e\u0440\u0440\u0435\u043a\u0442\u043d\u0430\u044f \u0437\u0430\u0447\u0438\u0441\u0442\u043a\u0430 \u0438\u043b\u0438 \u043e\u0441\u0432\u043e\u0431\u043e\u0436\u0434\u0435\u043d\u0438\u0435 \u0440\u0435\u0441\u0443\u0440\u0441\u043e\u0432 (CWE-404)",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u0434\u0438\u0441\u043f\u0435\u0442\u0447\u0435\u0440\u0430 \u0441\u0435\u0440\u0432\u0435\u0440\u043e\u0432 \u043b\u0438\u0446\u0435\u043d\u0437\u0438\u0439 lmadmin FlexNet Publisher \u0441\u0432\u044f\u0437\u0430\u043d\u0430 \u0441 \u043e\u0448\u0438\u0431\u043a\u0430\u043c\u0438 \u043f\u0440\u0438 \u043e\u0441\u0432\u043e\u0431\u043e\u0436\u0434\u0435\u043d\u0438\u0438 \u0440\u0435\u0441\u0443\u0440\u0441\u043e\u0432. \u042d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044f \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438 \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u0435\u0442 \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e, \u0434\u0435\u0439\u0441\u0442\u0432\u0443\u044e\u0449\u0435\u043c\u0443 \u0443\u0434\u0430\u043b\u0435\u043d\u043d\u043e, \u0432\u044b\u0437\u0432\u0430\u0442\u044c \u043e\u0442\u043a\u0430\u0437 \u0432 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0438",
"\u041f\u043e\u0441\u043b\u0435\u0434\u0441\u0442\u0432\u0438\u044f \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": null,
"\u041f\u0440\u043e\u0447\u0430\u044f \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f": null,
"\u0421\u0432\u044f\u0437\u044c \u0441 \u0438\u043d\u0446\u0438\u0434\u0435\u043d\u0442\u0430\u043c\u0438 \u0418\u0411": "\u0414\u0430\u043d\u043d\u044b\u0435 \u0443\u0442\u043e\u0447\u043d\u044f\u044e\u0442\u0441\u044f",
"\u0421\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041e\u043f\u0443\u0431\u043b\u0438\u043a\u043e\u0432\u0430\u043d\u0430",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044f": "\u041e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u0435 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438": "\u0418\u0441\u0447\u0435\u0440\u043f\u0430\u043d\u0438\u0435 \u0440\u0435\u0441\u0443\u0440\u0441\u043e\u0432",
"\u0421\u0441\u044b\u043b\u043a\u0438 \u043d\u0430 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u0438": "https://vuldb.com/ru/?id.190193\nhttps://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-07\nhttps://community.flexera.com/t5/FlexNet-Publisher-Knowledge-Base/CVE-2019-8963-Remediated-in-FlexNet-Publisher/ta-p/148768",
"\u0421\u0442\u0430\u0442\u0443\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0430 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u043c",
"\u0422\u0438\u043f \u041f\u041e": "\u041f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0435 \u0441\u0440\u0435\u0434\u0441\u0442\u0432\u043e \u0410\u0421\u0423 \u0422\u041f, \u041f\u0440\u0438\u043a\u043b\u0430\u0434\u043d\u043e\u0435 \u041f\u041e \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u043e\u043d\u043d\u044b\u0445 \u0441\u0438\u0441\u0442\u0435\u043c",
"\u0422\u0438\u043f \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "CWE-404",
"\u0423\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0412\u044b\u0441\u043e\u043a\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 2.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 7,8)\n\u0412\u044b\u0441\u043e\u043a\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 3.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 7,5)"
}
FKIE_CVE-2019-8963
Vulnerability from fkie_nvd - Published: 2023-03-29 21:15 - Updated: 2025-02-19 18:157.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
| Vendor | Product | Version | |
|---|---|---|---|
| flexera | flexnet_publisher | 11.16.5 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:flexera:flexnet_publisher:11.16.5:*:*:*:*:*:*:*",
"matchCriteriaId": "392E1CF7-00A2-4E24-90AC-48D207D680E2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A Denial of Service (DoS) vulnerability was discovered in FlexNet Publisher\u0027s lmadmin 11.16.5, when doing a crafted POST request on lmadmin using the web-based tool."
}
],
"id": "CVE-2019-8963",
"lastModified": "2025-02-19T18:15:20.310",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2023-03-29T21:15:07.753",
"references": [
{
"source": "PSIRT-CNA@flexerasoftware.com",
"tags": [
"Vendor Advisory"
],
"url": "https://community.flexera.com/t5/FlexNet-Publisher-Knowledge-Base/CVE-2019-8963-Remediated-in-FlexNet-Publisher/ta-p/148768"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://community.flexera.com/t5/FlexNet-Publisher-Knowledge-Base/CVE-2019-8963-Remediated-in-FlexNet-Publisher/ta-p/148768"
}
],
"sourceIdentifier": "PSIRT-CNA@flexerasoftware.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
GHSA-6GPC-QW5Q-FRJV
Vulnerability from github – Published: 2023-03-29 21:30 – Updated: 2023-04-06 21:30A Denial of Service (DoS) vulnerability was discovered in FlexNet Publisher's lmadmin 11.16.5, when doing a crafted POST request on lmadmin using the web-based tool.
{
"affected": [],
"aliases": [
"CVE-2019-8963"
],
"database_specific": {
"cwe_ids": [],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2023-03-29T21:15:00Z",
"severity": "HIGH"
},
"details": "A Denial of Service (DoS) vulnerability was discovered in FlexNet Publisher\u0027s lmadmin 11.16.5, when doing a crafted POST request on lmadmin using the web-based tool.",
"id": "GHSA-6gpc-qw5q-frjv",
"modified": "2023-04-06T21:30:20Z",
"published": "2023-03-29T21:30:16Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2019-8963"
},
{
"type": "WEB",
"url": "https://community.flexera.com/t5/FlexNet-Publisher-Knowledge-Base/CVE-2019-8963-Remediated-in-FlexNet-Publisher/ta-p/148768"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"type": "CVSS_V3"
}
]
}
GSD-2019-8963
Vulnerability from gsd - Updated: 2023-12-13 01:23{
"GSD": {
"alias": "CVE-2019-8963",
"id": "GSD-2019-8963"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2019-8963"
],
"details": "A Denial of Service (DoS) vulnerability was discovered in FlexNet Publisher\u0027s lmadmin 11.16.5, when doing a crafted POST request on lmadmin using the web-based tool.",
"id": "GSD-2019-8963",
"modified": "2023-12-13T01:23:48.178928Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "PSIRT-CNA@flexerasoftware.com",
"ID": "CVE-2019-8963",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A Denial of Service (DoS) vulnerability was discovered in FlexNet Publisher\u0027s lmadmin 11.16.5, when doing a crafted POST request on lmadmin using the web-based tool."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://community.flexera.com/t5/FlexNet-Publisher-Knowledge-Base/CVE-2019-8963-Remediated-in-FlexNet-Publisher/ta-p/148768",
"refsource": "CONFIRM",
"url": "https://community.flexera.com/t5/FlexNet-Publisher-Knowledge-Base/CVE-2019-8963-Remediated-in-FlexNet-Publisher/ta-p/148768"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:flexera:flexnet_publisher:11.16.5:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "PSIRT-CNA@flexerasoftware.com",
"ID": "CVE-2019-8963"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A Denial of Service (DoS) vulnerability was discovered in FlexNet Publisher\u0027s lmadmin 11.16.5, when doing a crafted POST request on lmadmin using the web-based tool."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://community.flexera.com/t5/FlexNet-Publisher-Knowledge-Base/CVE-2019-8963-Remediated-in-FlexNet-Publisher/ta-p/148768",
"refsource": "CONFIRM",
"tags": [
"Vendor Advisory"
],
"url": "https://community.flexera.com/t5/FlexNet-Publisher-Knowledge-Base/CVE-2019-8963-Remediated-in-FlexNet-Publisher/ta-p/148768"
}
]
}
},
"impact": {
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6
}
},
"lastModifiedDate": "2023-04-06T19:29Z",
"publishedDate": "2023-03-29T21:15Z"
}
}
}
SEVD-2022-011-07
Vulnerability from csaf_se - Published: 2022-01-11 13:20 - Updated: 2022-01-11 13:20A CWE-20: Improper Input Validation vulnerability exists that could allow arbitrary files on the server to be read by authenticated users through a limited operating system service account.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Schneider Electric EcoStruxure Power Monitoring Exper <=2020
Schneider Electric / EcoStruxure Power Monitoring Exper
|
<=2020 |
Vendor Fix
fix
Vendor Fix
fix
|
|
|
Schneider Electric EcoStruxure Power Monitoring Exper <=9.0
Schneider Electric / EcoStruxure Power Monitoring Exper
|
<=9.0 |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Schneider Electric EcoStruxure Power Monitoring Exper 2020 CU3
Schneider Electric / EcoStruxure Power Monitoring Exper
|
2020 CU3 | ||
|
Schneider Electric EcoStruxure Power Monitoring Exper 2021
Schneider Electric / EcoStruxure Power Monitoring Exper
|
2021 |
A CWE-20: Improper Input Validation vulnerability exists that could allow an unauthenticated attacker to view data, change settings, impact availability of the software, or potentially impact a user’s local machine when the user clicks a specially crafted link.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Schneider Electric EcoStruxure Power Monitoring Exper <=2020
Schneider Electric / EcoStruxure Power Monitoring Exper
|
<=2020 |
Vendor Fix
fix
Vendor Fix
fix
|
|
|
Schneider Electric EcoStruxure Power Monitoring Exper <=9.0
Schneider Electric / EcoStruxure Power Monitoring Exper
|
<=9.0 |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Schneider Electric EcoStruxure Power Monitoring Exper 2020 CU3
Schneider Electric / EcoStruxure Power Monitoring Exper
|
2020 CU3 | ||
|
Schneider Electric EcoStruxure Power Monitoring Exper 2021
Schneider Electric / EcoStruxure Power Monitoring Exper
|
2021 |
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could allow an authenticated attacker to view data, change settings, or impact availability of the software when the user visits a page containing the injected payload.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Schneider Electric EcoStruxure Power Monitoring Exper <=2020
Schneider Electric / EcoStruxure Power Monitoring Exper
|
<=2020 |
Vendor Fix
fix
Vendor Fix
fix
|
|
|
Schneider Electric EcoStruxure Power Monitoring Exper <=9.0
Schneider Electric / EcoStruxure Power Monitoring Exper
|
<=9.0 |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Schneider Electric EcoStruxure Power Monitoring Exper 2020 CU3
Schneider Electric / EcoStruxure Power Monitoring Exper
|
2020 CU3 | ||
|
Schneider Electric EcoStruxure Power Monitoring Exper 2021
Schneider Electric / EcoStruxure Power Monitoring Exper
|
2021 |
A Denial of Service vulnerability exists in FlexNet Publisher's lmadmin tool, when doing a crafted POST request on lmadmin using web-based tool. This tool is deployed with PME and an attacker leveraging this vulnerability may be able, with a sustained attack, to stop PME from operating
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Schneider Electric EcoStruxure Power Monitoring Exper <=2020
Schneider Electric / EcoStruxure Power Monitoring Exper
|
<=2020 |
Vendor Fix
fix
Vendor Fix
fix
|
|
|
Schneider Electric EcoStruxure Power Monitoring Exper <=9.0
Schneider Electric / EcoStruxure Power Monitoring Exper
|
<=9.0 |
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Schneider Electric EcoStruxure Power Monitoring Exper 2020 CU3
Schneider Electric / EcoStruxure Power Monitoring Exper
|
2020 CU3 | ||
|
Schneider Electric EcoStruxure Power Monitoring Exper 2021
Schneider Electric / EcoStruxure Power Monitoring Exper
|
2021 |
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Public",
"tlp": {
"label": "WHITE"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "We strongly recommend the following industry cybersecurity best practices.\n\nhttps://www.se.com/us/en/download/document/7EN52-0390/\n* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\n* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.\n* Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.\n* Never connect programming software to any network other than the network intended for that device.\n* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.\n* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.\n* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.\n* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\nFor more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. \n",
"title": "General Security Recommendations"
},
{
"category": "general",
"text": "This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.\nFor further information related to cybersecurity in Schneider Electric\u2019s products, visit the company\u2019s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp",
"title": "For More Information"
},
{
"category": "legal_disclaimer",
"text": "THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION",
"title": "LEGAL DISCLAIMER"
},
{
"category": "general",
"text": "At Schneider, we believe access to energy and digital is a basic human right. We empower all to do more with less, ensuring Life Is On everywhere, for everyone, at every moment.\n\nWe provide energy and automation digital solutions for efficiency and sustainability. We combine world-leading energy technologies, real-time automation, software and services into integrated solutions for Homes, Buildings, Data Centers, Infrastructure and Industries.\n\nWe are committed to unleash the infinite possibilities of an open, global, innovative community that is passionate with our Meaningful Purpose, Inclusive and Empowered values.\n\nwww.se.com ",
"title": "About Schneider Electric"
},
{
"category": "summary",
"text": "Schneider Electric is aware of multiple vulnerabilities in its EcoStruxure\u2122 Power Monitoring\r\nExpert product (PME).\r\nEcoStruxure Power Monitoring Expert is on-premise software used to help power-critical and energy-intensive facilities maximize uptime and operational efficiency.\r\nFailure to apply the remediation provided below may risk loss of data confidentiality, data integrity issues, or a loss of access to the server.\r",
"title": "Overview"
}
],
"publisher": {
"category": "vendor",
"contact_details": "cybersecurity@se.com",
"name": "Schneider Electric CPCERT",
"namespace": "https://www.se.com/ww/en/work/support/cybersecurity/security-notifications.jsp"
},
"references": [
{
"category": "self",
"summary": "EcoStruxure\u2122 Power Monitoring Expert - SEVD-2022-011-07 PDF Version",
"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-011-07_EcoStruxure_Power_Monitoring_Expert_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2022-011-07\u0026_ga=2.264993807.1277613497.1664186063-1964063624.1663165410"
},
{
"category": "self",
"summary": "EcoStruxure\u2122 Power Monitoring Expert - SEVD-2022-011-07 CSAF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-011-07\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2022-011-07.json"
},
{
"category": "self",
"summary": "Recommended Cybersecurity Best Practices",
"url": "https://www.se.com/us/en/download/document/7EN52-0390/"
}
],
"title": "EcoStruxure\u2122 Power Monitoring Expert",
"tracking": {
"current_release_date": "2022-01-11T13:20:28.000Z",
"generator": {
"date": "2022-09-26T13:28:40.154Z",
"engine": {
"name": "Secvisogram",
"version": "1.14.0"
}
},
"id": "SEVD-2022-011-07",
"initial_release_date": "2022-01-11T13:20:28.000Z",
"revision_history": [
{
"date": "2022-01-11T13:20:28.000Z",
"number": "1",
"summary": "Original Release"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=2020",
"product": {
"name": "Schneider Electric EcoStruxure Power Monitoring Exper \u003c=2020",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "EcoStruxure Power Monitoring Exper"
},
{
"branches": [
{
"category": "product_version",
"name": "2020 CU3",
"product": {
"name": "Schneider Electric EcoStruxure Power Monitoring Exper 2020 CU3",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "EcoStruxure Power Monitoring Exper"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=9.0",
"product": {
"name": "Schneider Electric EcoStruxure Power Monitoring Exper \u003c=9.0",
"product_id": "3"
}
}
],
"category": "product_name",
"name": "EcoStruxure Power Monitoring Exper"
},
{
"branches": [
{
"category": "product_version",
"name": "2021",
"product": {
"name": "Schneider Electric EcoStruxure Power Monitoring Exper 2021",
"product_id": "4"
}
}
],
"category": "product_name",
"name": "EcoStruxure Power Monitoring Exper"
}
],
"category": "vendor",
"name": "Schneider Electric"
}
]
},
"vulnerabilities": [
{
"acknowledgments": [
{
"names": [
"Robert Erbes"
],
"organization": "U.S. Department of Energy CyTRICS- INL"
}
],
"cve": "CVE-2022-22726",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"category": "description",
"text": "A CWE-20: Improper Input Validation vulnerability exists that could allow arbitrary files on the\r\nserver to be read by authenticated users through a limited operating system service account. \r",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"2",
"4"
],
"known_affected": [
"1",
"3"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Remediation Steps:\r\n1. Install Version 2020 CU3 of EcoStruxure Power Monitoring\r\nExpert which includes a fix for CVE-2022-22726, CVE-2022-\r\n22727, and CVE-2022-22804.\r\n2. Install Floating License Manager 2.7 after PME 2020 CU3\r\ninstallation to address CVE-2019-8963.\r\nBoth updates can be downloaded here:\r\nhttps://schneiderelectric.app.box.com/folder/152201039971?s=dwbjm0bp3850ek95zyinv6g7nqjj86fm",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://schneider-electric.app.box.com/folder/152201039971?s=dwbjm0bp3850ek95zyinv6g7nqjj86fm"
},
{
"category": "vendor_fix",
"details": "Contact your Schneider Electric representative for details on how to\r\nupgrade to PME 2021",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://schneider-electric.app.box.com/folder/152201039971?s=dwbjm0bp3850ek95zyinv6g7nqjj86fm"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N",
"version": "3.1"
},
"products": [
"1",
"3"
]
}
],
"title": "CVE-2022-22726"
},
{
"acknowledgments": [
{
"names": [
"Robert Erbes"
],
"organization": "U.S. Department of Energy CyTRICS- INL"
}
],
"cve": "CVE-2022-22727",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"category": "description",
"text": "A CWE-20: Improper Input Validation vulnerability exists that could allow an unauthenticated\r\nattacker to view data, change settings, impact availability of the software, or potentially impact a\r\nuser\u2019s local machine when the user clicks a specially crafted link.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"2",
"4"
],
"known_affected": [
"1",
"3"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Remediation Steps:\r\n1. Install Version 2020 CU3 of EcoStruxure Power Monitoring\r\nExpert which includes a fix for CVE-2022-22726, CVE-2022-\r\n22727, and CVE-2022-22804.\r\n2. Install Floating License Manager 2.7 after PME 2020 CU3\r\ninstallation to address CVE-2019-8963.\r\nBoth updates can be downloaded here:\r\nhttps://schneiderelectric.app.box.com/folder/152201039971?s=dwbjm0bp3850ek95zyinv6g7nqjj86fm",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://schneider-electric.app.box.com/folder/152201039971?s=dwbjm0bp3850ek95zyinv6g7nqjj86fm"
},
{
"category": "vendor_fix",
"details": "Contact your Schneider Electric representative for details on how to\r\nupgrade to PME 2021",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://schneider-electric.app.box.com/folder/152201039971?s=dwbjm0bp3850ek95zyinv6g7nqjj86fm"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:H",
"version": "3.1"
},
"products": [
"1",
"3"
]
}
],
"title": "CVE-2022-22727"
},
{
"acknowledgments": [
{
"names": [
"Robert Erbes"
],
"organization": "U.S. Department of Energy CyTRICS- INL"
}
],
"cve": "CVE-2022-22804",
"cwe": {
"id": "CWE-79",
"name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
},
"notes": [
{
"category": "description",
"text": "A CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site\r\nScripting\u0027) vulnerability exists that could allow an authenticated attacker to view data, change\r\nsettings, or impact availability of the software when the user visits a page containing the injected\r\npayload.",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"2",
"4"
],
"known_affected": [
"1",
"3"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Remediation Steps:\r\n1. Install Version 2020 CU3 of EcoStruxure Power Monitoring\r\nExpert which includes a fix for CVE-2022-22726, CVE-2022-\r\n22727, and CVE-2022-22804.\r\n2. Install Floating License Manager 2.7 after PME 2020 CU3\r\ninstallation to address CVE-2019-8963.\r\nBoth updates can be downloaded here:\r\nhttps://schneiderelectric.app.box.com/folder/152201039971?s=dwbjm0bp3850ek95zyinv6g7nqjj86fm",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://schneider-electric.app.box.com/folder/152201039971?s=dwbjm0bp3850ek95zyinv6g7nqjj86fm"
},
{
"category": "vendor_fix",
"details": "Contact your Schneider Electric representative for details on how to\r\nupgrade to PME 2021",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://schneider-electric.app.box.com/folder/152201039971?s=dwbjm0bp3850ek95zyinv6g7nqjj86fm"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:L/I:H/A:H",
"version": "3.1"
},
"products": [
"1",
"3"
]
}
],
"title": "CVE-2022-22804"
},
{
"cve": "CVE-2019-8963",
"notes": [
{
"category": "description",
"text": "A Denial of Service vulnerability exists in FlexNet Publisher\u0027s lmadmin tool, when doing a\r\ncrafted POST request on lmadmin using web-based tool. This tool is deployed with PME and an\r\nattacker leveraging this vulnerability may be able, with a sustained attack, to stop PME from\r\noperating",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"2",
"4"
],
"known_affected": [
"1",
"3"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "Remediation Steps:\r\n1. Install Version 2020 CU3 of EcoStruxure Power Monitoring\r\nExpert which includes a fix for CVE-2022-22726, CVE-2022-\r\n22727, and CVE-2022-22804.\r\n2. Install Floating License Manager 2.7 after PME 2020 CU3\r\ninstallation to address CVE-2019-8963.\r\nBoth updates can be downloaded here:\r\nhttps://schneiderelectric.app.box.com/folder/152201039971?s=dwbjm0bp3850ek95zyinv6g7nqjj86fm",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://schneider-electric.app.box.com/folder/152201039971?s=dwbjm0bp3850ek95zyinv6g7nqjj86fm"
},
{
"category": "vendor_fix",
"details": "Contact your Schneider Electric representative for details on how to\r\nupgrade to PME 2021",
"product_ids": [
"1"
],
"restart_required": {
"category": "none"
},
"url": "https://schneider-electric.app.box.com/folder/152201039971?s=dwbjm0bp3850ek95zyinv6g7nqjj86fm"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"products": [
"1",
"3"
]
}
],
"title": "CVE-2019-8963"
}
]
}
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.