cve-2020-3233
Vulnerability from cvelistv5
Published
2020-06-03 17:55
Modified
2024-11-15 17:12
Severity ?
EPSS score ?
Summary
A vulnerability in the web-based Local Manager interface of the Cisco IOx Application Framework could allow an authenticated, remote attacker to conduct a stored cross-site scripting (XSS) attack against a user of the web-based Local Manager interface of an affected device. The attacker must have valid Local Manager credentials. The vulnerability is due to insufficient validation of user-supplied input by the web-based Local Manager interface of the affected software. An attacker could exploit this vulnerability by injecting malicious code into a system settings tab. A successful exploit could allow the attacker to execute arbitrary script code in the context of the affected web interface or allow the attacker to access sensitive browser-based information.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T07:30:56.944Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "20200603 Cisco IOx Application Framework Local Manager Stored Cross-Site Scripting Vulnerability", "tags": [ "vendor-advisory", "x_refsource_CISCO", "x_transferred" ], "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-ioxxss-wc6CqUws" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2020-3233", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-11-15T16:28:02.127138Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-15T17:12:07.926Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "Cisco IOx", "vendor": "Cisco", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2020-06-03T00:00:00", "descriptions": [ { "lang": "en", "value": "A vulnerability in the web-based Local Manager interface of the Cisco IOx Application Framework could allow an authenticated, remote attacker to conduct a stored cross-site scripting (XSS) attack against a user of the web-based Local Manager interface of an affected device. The attacker must have valid Local Manager credentials. The vulnerability is due to insufficient validation of user-supplied input by the web-based Local Manager interface of the affected software. An attacker could exploit this vulnerability by injecting malicious code into a system settings tab. A successful exploit could allow the attacker to execute arbitrary script code in the context of the affected web interface or allow the attacker to access sensitive browser-based information." } ], "exploits": [ { "lang": "en", "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-79", "description": "CWE-79", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-03T17:55:33", "orgId": "d1c1063e-7a18-46af-9102-31f8928bc633", "shortName": "cisco" }, "references": [ { "name": "20200603 Cisco IOx Application Framework Local Manager Stored Cross-Site Scripting Vulnerability", "tags": [ "vendor-advisory", "x_refsource_CISCO" ], "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-ioxxss-wc6CqUws" } ], "source": { "advisory": "cisco-sa-ioxxss-wc6CqUws", "defect": [ [ "CSCvq71085", "CSCvr88502", "CSCvr88504", "CSCvr88513", "CSCvr88539" ] ], "discovery": "INTERNAL" }, "title": "Cisco IOx Application Framework Local Manager Stored Cross-Site Scripting Vulnerability", "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "psirt@cisco.com", "DATE_PUBLIC": "2020-06-03T16:00:00", "ID": "CVE-2020-3233", "STATE": "PUBLIC", "TITLE": "Cisco IOx Application Framework Local Manager Stored Cross-Site Scripting Vulnerability" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Cisco IOx", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "Cisco" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability in the web-based Local Manager interface of the Cisco IOx Application Framework could allow an authenticated, remote attacker to conduct a stored cross-site scripting (XSS) attack against a user of the web-based Local Manager interface of an affected device. The attacker must have valid Local Manager credentials. The vulnerability is due to insufficient validation of user-supplied input by the web-based Local Manager interface of the affected software. An attacker could exploit this vulnerability by injecting malicious code into a system settings tab. A successful exploit could allow the attacker to execute arbitrary script code in the context of the affected web interface or allow the attacker to access sensitive browser-based information." } ] }, "exploit": [ { "lang": "en", "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory." } ], "impact": { "cvss": { "baseScore": "6.4", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-79" } ] } ] }, "references": { "reference_data": [ { "name": "20200603 Cisco IOx Application Framework Local Manager Stored Cross-Site Scripting Vulnerability", "refsource": "CISCO", "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-ioxxss-wc6CqUws" } ] }, "source": { "advisory": "cisco-sa-ioxxss-wc6CqUws", "defect": [ [ "CSCvq71085", "CSCvr88502", "CSCvr88504", "CSCvr88513", "CSCvr88539" ] ], "discovery": "INTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633", "assignerShortName": "cisco", "cveId": "CVE-2020-3233", "datePublished": "2020-06-03T17:55:33.850335Z", "dateReserved": "2019-12-12T00:00:00", "dateUpdated": "2024-11-15T17:12:07.926Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "fkie_nvd": { "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:cisco:iox:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.9.0\", \"matchCriteriaId\": \"43DA2F2B-ABA7-4294-922C-C2CDA197063C\"}]}]}]", "descriptions": "[{\"lang\": \"en\", \"value\": \"A vulnerability in the web-based Local Manager interface of the Cisco IOx Application Framework could allow an authenticated, remote attacker to conduct a stored cross-site scripting (XSS) attack against a user of the web-based Local Manager interface of an affected device. The attacker must have valid Local Manager credentials. The vulnerability is due to insufficient validation of user-supplied input by the web-based Local Manager interface of the affected software. An attacker could exploit this vulnerability by injecting malicious code into a system settings tab. A successful exploit could allow the attacker to execute arbitrary script code in the context of the affected web interface or allow the attacker to access sensitive browser-based information.\"}, {\"lang\": \"es\", \"value\": \"Una vulnerabilidad en la interfaz Local Manager basada en web de Cisco IOx Application Framework, podr\\u00eda permitir a un atacante remoto autenticado llevar a cabo un ataque de tipo cross site scripting (XSS) almacenado contra un usuario de la interfaz Local Manager basada en web de un dispositivo afectado . El atacante debe tener credenciales de administrador local v\\u00e1lidas. La vulnerabilidad es debido a una comprobaci\\u00f3n insuficiente de la entrada suministrada por el usuario mediante la interfaz Local Manager basada en web del software afectado. Un atacante podr\\u00eda explotar esta vulnerabilidad al inyectar c\\u00f3digo malicioso en una pesta\\u00f1a de configuraci\\u00f3n del sistema. Una explotaci\\u00f3n con \\u00e9xito podr\\u00eda permitir al atacante ejecutar c\\u00f3digo script arbitrario en el contexto de la interfaz web afectada o permitirle al atacante acceder a informaci\\u00f3n confidencial basada en navegador.\"}]", "id": "CVE-2020-3233", "lastModified": "2024-11-21T05:30:37.330", "metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N\", \"baseScore\": 5.4, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"REQUIRED\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 2.3, \"impactScore\": 2.7}], \"cvssMetricV30\": [{\"source\": \"ykramarz@cisco.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:N\", \"baseScore\": 6.4, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 3.1, \"impactScore\": 2.7}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:S/C:N/I:P/A:N\", \"baseScore\": 3.5, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"SINGLE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"LOW\", \"exploitabilityScore\": 6.8, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": true}]}", "published": "2020-06-03T18:15:21.277", "references": "[{\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-ioxxss-wc6CqUws\", \"source\": \"ykramarz@cisco.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-ioxxss-wc6CqUws\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]", "sourceIdentifier": "ykramarz@cisco.com", "vulnStatus": "Modified", "weaknesses": "[{\"source\": \"ykramarz@cisco.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-79\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-79\"}]}]" }, "nvd": "{\"cve\":{\"id\":\"CVE-2020-3233\",\"sourceIdentifier\":\"ykramarz@cisco.com\",\"published\":\"2020-06-03T18:15:21.277\",\"lastModified\":\"2024-11-21T05:30:37.330\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability in the web-based Local Manager interface of the Cisco IOx Application Framework could allow an authenticated, remote attacker to conduct a stored cross-site scripting (XSS) attack against a user of the web-based Local Manager interface of an affected device. The attacker must have valid Local Manager credentials. The vulnerability is due to insufficient validation of user-supplied input by the web-based Local Manager interface of the affected software. An attacker could exploit this vulnerability by injecting malicious code into a system settings tab. A successful exploit could allow the attacker to execute arbitrary script code in the context of the affected web interface or allow the attacker to access sensitive browser-based information.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad en la interfaz Local Manager basada en web de Cisco IOx Application Framework, podr\u00eda permitir a un atacante remoto autenticado llevar a cabo un ataque de tipo cross site scripting (XSS) almacenado contra un usuario de la interfaz Local Manager basada en web de un dispositivo afectado . El atacante debe tener credenciales de administrador local v\u00e1lidas. La vulnerabilidad es debido a una comprobaci\u00f3n insuficiente de la entrada suministrada por el usuario mediante la interfaz Local Manager basada en web del software afectado. Un atacante podr\u00eda explotar esta vulnerabilidad al inyectar c\u00f3digo malicioso en una pesta\u00f1a de configuraci\u00f3n del sistema. Una explotaci\u00f3n con \u00e9xito podr\u00eda permitir al atacante ejecutar c\u00f3digo script arbitrario en el contexto de la interfaz web afectada o permitirle al atacante acceder a informaci\u00f3n confidencial basada en navegador.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":5.4,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.3,\"impactScore\":2.7}],\"cvssMetricV30\":[{\"source\":\"ykramarz@cisco.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:N\",\"baseScore\":6.4,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.1,\"impactScore\":2.7}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:S/C:N/I:P/A:N\",\"baseScore\":3.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"LOW\",\"exploitabilityScore\":6.8,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"ykramarz@cisco.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:iox:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.9.0\",\"matchCriteriaId\":\"43DA2F2B-ABA7-4294-922C-C2CDA197063C\"}]}]}],\"references\":[{\"url\":\"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-ioxxss-wc6CqUws\",\"source\":\"ykramarz@cisco.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-ioxxss-wc6CqUws\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}", "vulnrichment": { "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-ioxxss-wc6CqUws\", \"name\": \"20200603 Cisco IOx Application Framework Local Manager Stored Cross-Site Scripting Vulnerability\", \"tags\": [\"vendor-advisory\", \"x_refsource_CISCO\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-04T07:30:56.944Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2020-3233\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-11-15T16:28:02.127138Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-11-15T16:28:34.501Z\"}}], \"cna\": {\"title\": \"Cisco IOx Application Framework Local Manager Stored Cross-Site Scripting Vulnerability\", \"source\": {\"defect\": [[\"CSCvq71085\", \"CSCvr88502\", \"CSCvr88504\", \"CSCvr88513\", \"CSCvr88539\"]], \"advisory\": \"cisco-sa-ioxxss-wc6CqUws\", \"discovery\": \"INTERNAL\"}, \"metrics\": [{\"cvssV3_0\": {\"scope\": \"CHANGED\", \"version\": \"3.0\", \"baseScore\": 6.4, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:N\", \"integrityImpact\": \"LOW\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"LOW\"}}], \"affected\": [{\"vendor\": \"Cisco\", \"product\": \"Cisco IOx\", \"versions\": [{\"status\": \"affected\", \"version\": \"n/a\"}]}], \"exploits\": [{\"lang\": \"en\", \"value\": \"The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory.\"}], \"datePublic\": \"2020-06-03T00:00:00\", \"references\": [{\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-ioxxss-wc6CqUws\", \"name\": \"20200603 Cisco IOx Application Framework Local Manager Stored Cross-Site Scripting Vulnerability\", \"tags\": [\"vendor-advisory\", \"x_refsource_CISCO\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability in the web-based Local Manager interface of the Cisco IOx Application Framework could allow an authenticated, remote attacker to conduct a stored cross-site scripting (XSS) attack against a user of the web-based Local Manager interface of an affected device. The attacker must have valid Local Manager credentials. The vulnerability is due to insufficient validation of user-supplied input by the web-based Local Manager interface of the affected software. An attacker could exploit this vulnerability by injecting malicious code into a system settings tab. A successful exploit could allow the attacker to execute arbitrary script code in the context of the affected web interface or allow the attacker to access sensitive browser-based information.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-79\", \"description\": \"CWE-79\"}]}], \"providerMetadata\": {\"orgId\": \"d1c1063e-7a18-46af-9102-31f8928bc633\", \"shortName\": \"cisco\", \"dateUpdated\": \"2020-06-03T17:55:33\"}, \"x_legacyV4Record\": {\"impact\": {\"cvss\": {\"version\": \"3.0\", \"baseScore\": \"6.4\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:N\"}}, \"source\": {\"defect\": [[\"CSCvq71085\", \"CSCvr88502\", \"CSCvr88504\", \"CSCvr88513\", \"CSCvr88539\"]], \"advisory\": \"cisco-sa-ioxxss-wc6CqUws\", \"discovery\": \"INTERNAL\"}, \"affects\": {\"vendor\": {\"vendor_data\": [{\"product\": {\"product_data\": [{\"version\": {\"version_data\": [{\"version_value\": \"n/a\"}]}, \"product_name\": \"Cisco IOx\"}]}, \"vendor_name\": \"Cisco\"}]}}, \"exploit\": [{\"lang\": \"en\", \"value\": \"The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory.\"}], \"data_type\": \"CVE\", \"references\": {\"reference_data\": [{\"url\": \"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-ioxxss-wc6CqUws\", \"name\": \"20200603 Cisco IOx Application Framework Local Manager Stored Cross-Site Scripting Vulnerability\", \"refsource\": \"CISCO\"}]}, \"data_format\": \"MITRE\", \"description\": {\"description_data\": [{\"lang\": \"eng\", \"value\": \"A vulnerability in the web-based Local Manager interface of the Cisco IOx Application Framework could allow an authenticated, remote attacker to conduct a stored cross-site scripting (XSS) attack against a user of the web-based Local Manager interface of an affected device. The attacker must have valid Local Manager credentials. The vulnerability is due to insufficient validation of user-supplied input by the web-based Local Manager interface of the affected software. An attacker could exploit this vulnerability by injecting malicious code into a system settings tab. A successful exploit could allow the attacker to execute arbitrary script code in the context of the affected web interface or allow the attacker to access sensitive browser-based information.\"}]}, \"problemtype\": {\"problemtype_data\": [{\"description\": [{\"lang\": \"eng\", \"value\": \"CWE-79\"}]}]}, \"data_version\": \"4.0\", \"CVE_data_meta\": {\"ID\": \"CVE-2020-3233\", \"STATE\": \"PUBLIC\", \"TITLE\": \"Cisco IOx Application Framework Local Manager Stored Cross-Site Scripting Vulnerability\", \"ASSIGNER\": \"psirt@cisco.com\", \"DATE_PUBLIC\": \"2020-06-03T16:00:00\"}}}}", "cveMetadata": "{\"cveId\": \"CVE-2020-3233\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-11-15T17:12:07.926Z\", \"dateReserved\": \"2019-12-12T00:00:00\", \"assignerOrgId\": \"d1c1063e-7a18-46af-9102-31f8928bc633\", \"datePublished\": \"2020-06-03T17:55:33.850335Z\", \"assignerShortName\": \"cisco\"}", "dataType": "CVE_RECORD", "dataVersion": "5.1" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.