cve-2020-3301
Vulnerability from cvelistv5
Published
2020-05-06 16:42
Modified
2024-11-15 17:23
Severity ?
EPSS score ?
Summary
Cisco Firepower Management Center Static Credential Vulnerabilities
References
Impacted products
▼ | Vendor | Product |
---|---|---|
Cisco | Cisco Firepower Management Center |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T07:30:57.688Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "20200506 Cisco Firepower Management Center Static Credential Vulnerabilities", "tags": [ "vendor-advisory", "x_refsource_CISCO", "x_transferred" ], "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmcua-statcred-weeCcZct" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2020-3301", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-11-15T16:24:40.231838Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-15T17:23:23.050Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "Cisco Firepower Management Center", "vendor": "Cisco", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2020-05-06T00:00:00", "descriptions": [ { "lang": "en", "value": "Multiple vulnerabilities in Cisco Firepower Management Center (FMC) Software and Cisco Firepower User Agent Software could allow an attacker to access a sensitive part of an affected system with a high-privileged account. For more information about these vulnerabilities, see the Details section of this advisory." } ], "exploits": [ { "lang": "en", "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-798", "description": "CWE-798", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-05-06T16:42:11", "orgId": "d1c1063e-7a18-46af-9102-31f8928bc633", "shortName": "cisco" }, "references": [ { "name": "20200506 Cisco Firepower Management Center Static Credential Vulnerabilities", "tags": [ "vendor-advisory", "x_refsource_CISCO" ], "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmcua-statcred-weeCcZct" } ], "source": { "advisory": "cisco-sa-fmcua-statcred-weeCcZct", "defect": [ [ "CSCvo08211", "CSCvq50674" ] ], "discovery": "INTERNAL" }, "title": "Cisco Firepower Management Center Static Credential Vulnerabilities", "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "psirt@cisco.com", "DATE_PUBLIC": "2020-05-06T16:00:00-0700", "ID": "CVE-2020-3301", "STATE": "PUBLIC", "TITLE": "Cisco Firepower Management Center Static Credential Vulnerabilities" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Cisco Firepower Management Center", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "Cisco" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Multiple vulnerabilities in Cisco Firepower Management Center (FMC) Software and Cisco Firepower User Agent Software could allow an attacker to access a sensitive part of an affected system with a high-privileged account. For more information about these vulnerabilities, see the Details section of this advisory." } ] }, "exploit": [ { "lang": "en", "value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory." } ], "impact": { "cvss": { "baseScore": "8.1", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-798" } ] } ] }, "references": { "reference_data": [ { "name": "20200506 Cisco Firepower Management Center Static Credential Vulnerabilities", "refsource": "CISCO", "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmcua-statcred-weeCcZct" } ] }, "source": { "advisory": "cisco-sa-fmcua-statcred-weeCcZct", "defect": [ [ "CSCvo08211", "CSCvq50674" ] ], "discovery": "INTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633", "assignerShortName": "cisco", "cveId": "CVE-2020-3301", "datePublished": "2020-05-06T16:42:12.016638Z", "dateReserved": "2019-12-12T00:00:00", "dateUpdated": "2024-11-15T17:23:23.050Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2020-3301\",\"sourceIdentifier\":\"ykramarz@cisco.com\",\"published\":\"2020-05-06T17:15:13.010\",\"lastModified\":\"2020-05-08T20:28:03.397\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"Multiple vulnerabilities in Cisco Firepower Management Center (FMC) Software and Cisco Firepower User Agent Software could allow an attacker to access a sensitive part of an affected system with a high-privileged account. For more information about these vulnerabilities, see the Details section of this advisory.\"},{\"lang\":\"es\",\"value\":\"M\u00faltiples vulnerabilidades en el Cisco Firepower Management Center (FMC) Software y el Cisco Firepower User Agent Software, podr\u00edan permitir a un atacante acceder a una parte confidencial de un sistema afectado con una cuenta muy privilegiada. Para m\u00e1s informaci\u00f3n sobre estas vulnerabilidades, consulte la secci\u00f3n Detalles de este aviso.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":4.4,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":0.8,\"impactScore\":3.6}],\"cvssMetricV30\":[{\"source\":\"ykramarz@cisco.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":8.1,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":2.2,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:P/I:N/A:N\",\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":2.1},\"baseSeverity\":\"LOW\",\"exploitabilityScore\":3.9,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-798\"}]},{\"source\":\"ykramarz@cisco.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-798\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:firepower_management_center:2.0.3:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8FE21958-6495-46D7-877B-263521F708AD\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:firepower_management_center:2.1.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D603E4DD-A228-48A2-B1B6-6558DA8847C3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:firepower_management_center:2.1.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0B76D909-5A87-45E1-9232-4A23BFBADE65\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:firepower_management_center:2.2.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5CC8FCB2-47C6-4BF0-BB78-631BF4755D97\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:firepower_management_center:2.3.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CFDD4724-BDD5-4498-B6BF-E34DA1322F0C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:firepower_management_center:5.0.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"29D70405-44DE-403E-8447-72EC049D2CA6\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:firepower_management_center:6.0.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B6FFC36B-7EC9-48C2-87B0-E267EBF04779\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:firepower_management_center:6.1.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2AC1B12A-A2EC-4C24-AEBC-944AE2939458\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:firepower_management_center:6.2.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9641FE9B-BC9F-472F-B53B-F4287EE2F17A\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:firepower_management_center:6.2.3:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DB01FA17-68F7-47E6-9D94-AC3C290F62AE\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:firepower_management_center:6.3.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"134CD651-CA72-47A0-8B48-A9C332C02013\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:firepower_management_center:6.4.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DA61E6F5-FFFD-4D4E-9AA3-94F827A79F4C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:cisco:firepower_management_center:6.5.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4A995913-A8DB-4536-93BF-AAF82F0FCDB7\"}]}]}],\"references\":[{\"url\":\"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmcua-statcred-weeCcZct\",\"source\":\"ykramarz@cisco.com\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.