CVE-2020-7544 (GCVE-0-2020-7544)
Vulnerability from cvelistv5 – Published: 2020-11-19 21:05 – Updated: 2024-08-04 09:33- CWE-269 - Improper Privilege Management
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | EcoStruxureª Operator Terminal Expert runtime (Vijeo XD) |
Affected:
EcoStruxureª Operator Terminal Expert runtime (Vijeo XD)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:33:19.866Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-02/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "EcoStruxure\u00aa Operator Terminal Expert runtime (Vijeo XD)",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "EcoStruxure\u00aa Operator Terminal Expert runtime (Vijeo XD)"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-269 Improper Privilege Management vulnerability exists in EcoStruxure\u00aa Operator Terminal Expert runtime (Vijeo XD) that could cause privilege escalation on the workstation when interacting directly with a driver installed by the runtime software of EcoStruxure\u00aa Operator Terminal Expert."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "CWE-269:Improper Privilege Management",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-19T21:05:04.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-02/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2020-7544",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "EcoStruxure\u00aa Operator Terminal Expert runtime (Vijeo XD)",
"version": {
"version_data": [
{
"version_value": "EcoStruxure\u00aa Operator Terminal Expert runtime (Vijeo XD)"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-269 Improper Privilege Management vulnerability exists in EcoStruxure\u00aa Operator Terminal Expert runtime (Vijeo XD) that could cause privilege escalation on the workstation when interacting directly with a driver installed by the runtime software of EcoStruxure\u00aa Operator Terminal Expert."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-269:Improper Privilege Management"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-315-02/",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-02/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2020-7544",
"datePublished": "2020-11-19T21:05:04.000Z",
"dateReserved": "2020-01-21T00:00:00.000Z",
"dateUpdated": "2024-08-04T09:33:19.866Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2020-7544",
"date": "2026-04-19",
"epss": "0.00038",
"percentile": "0.11251"
},
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:operator_terminal_expert_runtime:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"3.1\", \"matchCriteriaId\": \"F020516C-FCA9-45DC-918D-CF47B0B11579\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:operator_terminal_expert_runtime:3.1:-:*:*:*:*:*:*\", \"matchCriteriaId\": \"ADD60642-45DE-4B0E-AA5D-8A361CBB847D\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:operator_terminal_expert_runtime:3.1:service_pack_1a:*:*:*:*:*:*\", \"matchCriteriaId\": \"671669BD-DF16-453E-A36F-7AD109F2097E\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"A CWE-269 Improper Privilege Management vulnerability exists in EcoStruxure\\u00aa Operator Terminal Expert runtime (Vijeo XD) that could cause privilege escalation on the workstation when interacting directly with a driver installed by the runtime software of EcoStruxure\\u00aa Operator Terminal Expert.\"}, {\"lang\": \"es\", \"value\": \"Se presenta una vulnerabilidad de Administraci\\u00f3n de Privilegios Inapropiado CWE-269 en el tiempo de ejecuci\\u00f3n de EcoStruxure\\u00aa Operator Terminal Expert (Vijeo XD) que podr\\u00eda causar una escalada de privilegios en la estaci\\u00f3n de trabajo al interactuar directamente con un controlador instalado por el software de tiempo de ejecuci\\u00f3n de EcoStruxure\\u00aa Operator Terminal Expert\"}]",
"id": "CVE-2020-7544",
"lastModified": "2024-11-21T05:37:21.100",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 7.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:L/AC:L/Au:N/C:C/I:C/A:C\", \"baseScore\": 7.2, \"accessVector\": \"LOCAL\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"COMPLETE\", \"integrityImpact\": \"COMPLETE\", \"availabilityImpact\": \"COMPLETE\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 3.9, \"impactScore\": 10.0, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2020-11-19T22:15:14.113",
"references": "[{\"url\": \"https://www.se.com/ww/en/download/document/SEVD-2020-315-02/\", \"source\": \"cybersecurity@se.com\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}, {\"url\": \"https://www.se.com/ww/en/download/document/SEVD-2020-315-02/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}]",
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"cybersecurity@se.com\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-269\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2020-7544\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2020-11-19T22:15:14.113\",\"lastModified\":\"2024-11-21T05:37:21.100\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A CWE-269 Improper Privilege Management vulnerability exists in EcoStruxure\u00aa Operator Terminal Expert runtime (Vijeo XD) that could cause privilege escalation on the workstation when interacting directly with a driver installed by the runtime software of EcoStruxure\u00aa Operator Terminal Expert.\"},{\"lang\":\"es\",\"value\":\"Se presenta una vulnerabilidad de Administraci\u00f3n de Privilegios Inapropiado CWE-269 en el tiempo de ejecuci\u00f3n de EcoStruxure\u00aa Operator Terminal Expert (Vijeo XD) que podr\u00eda causar una escalada de privilegios en la estaci\u00f3n de trabajo al interactuar directamente con un controlador instalado por el software de tiempo de ejecuci\u00f3n de EcoStruxure\u00aa Operator Terminal Expert\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:C/I:C/A:C\",\"baseScore\":7.2,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":3.9,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-269\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:operator_terminal_expert_runtime:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.1\",\"matchCriteriaId\":\"F020516C-FCA9-45DC-918D-CF47B0B11579\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:operator_terminal_expert_runtime:3.1:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"ADD60642-45DE-4B0E-AA5D-8A361CBB847D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:operator_terminal_expert_runtime:3.1:service_pack_1a:*:*:*:*:*:*\",\"matchCriteriaId\":\"671669BD-DF16-453E-A36F-7AD109F2097E\"}]}]}],\"references\":[{\"url\":\"https://www.se.com/ww/en/download/document/SEVD-2020-315-02/\",\"source\":\"cybersecurity@se.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://www.se.com/ww/en/download/document/SEVD-2020-315-02/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}"
}
}
CERTFR-2020-AVI-726
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider Electric. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | N/A | Premium processors avec Ethernet COPRO intégré (TSXP574634, TSXP575634, TSXP576634) toutes versions | ||
| Schneider Electric | N/A | Modicon M221 toutes références et toutes versions | ||
| Schneider Electric | N/A | PLC Simulator for EcoStruxure Control Expert toutes versions | ||
| Schneider Electric | N/A | EcoStruxure Building Operation - WebStation versions v2.0 à v3.1 | ||
| Schneider Electric | N/A | Quantum communication modules (140NOE771x1, 140NOC78x00, 140NOC77101) toutes versions | ||
| Schneider Electric | N/A | J Data Radios toutes versions | ||
| Schneider Electric | N/A | PLC Simulator for Unity Pro (anciennement EcoStruxure Control Expert) toutes versions | ||
| Schneider Electric | N/A | EcoStruxure Operator Terminal Expert Runtime 3.1 Service Pack 1A et versions antérieures (les ordinateurs Windows utilisant un UEFI ne sont pas impactés) | ||
| Schneider Electric | N/A | M340 modules de communication Ethernet (BMX NOE 0100 (H), BMX NOE 0110 (H), BMX NOC 0401, BMX NOR 0200H) toutes versions | ||
| Schneider Electric | N/A | Quantum processors avec Ethernet COPRO intégré 140CPU65xxxxx toutes versions | ||
| Schneider Electric | N/A | M340 CPUs BMX P34x toutes versions | ||
| Schneider Electric | N/A | EcoStruxure Building Operation - Enterprise Server installer versions v1.9 à v3.1 | ||
| Schneider Electric | N/A | Trio Q toutes versions | ||
| Schneider Electric | N/A | EcoStruxure Building Operation - WebReports versions v1.9 à v3.1 | ||
| Schneider Electric | N/A | Premium communication modules (TSXETY4103, TSXETY5103) toutes versions | ||
| Schneider Electric | N/A | EcoStruxure Building Operation - Enterprise Central installer versions v2.0 à v3.1 | ||
| Schneider Electric | N/A | IGSS Definition (Def.exe) version 14.0.0.20247 et versions antérieures | ||
| Schneider Electric | N/A | Easergy T300 versions antérieures à 2.7 |
| Title | Publication Time | Tags | ||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Premium processors avec Ethernet COPRO int\u00e9gr\u00e9 (TSXP574634, TSXP575634, TSXP576634) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M221 toutes r\u00e9f\u00e9rences et toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "PLC Simulator for EcoStruxure Control Expert toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Building Operation - WebStation versions v2.0 \u00e0 v3.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Quantum communication modules (140NOE771x1, 140NOC78x00, 140NOC77101) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "J Data Radios toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "PLC Simulator for Unity Pro (anciennement EcoStruxure Control Expert) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Operator Terminal Expert Runtime 3.1 Service Pack 1A et versions ant\u00e9rieures (les ordinateurs Windows utilisant un UEFI ne sont pas impact\u00e9s)",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "M340 modules de communication Ethernet (BMX NOE 0100 (H), BMX NOE 0110 (H), BMX NOC 0401, BMX NOR 0200H) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Quantum processors avec Ethernet COPRO int\u00e9gr\u00e9 140CPU65xxxxx toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "M340 CPUs BMX P34x toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Building Operation - Enterprise Server installer versions v1.9 \u00e0 v3.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Trio Q toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Building Operation - WebReports versions v1.9 \u00e0 v3.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Premium communication modules (TSXETY4103, TSXETY5103) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Building Operation - Enterprise Central installer versions v2.0 \u00e0 v3.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "IGSS Definition (Def.exe) version 14.0.0.20247 et versions ant\u00e9rieures",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Easergy T300 versions ant\u00e9rieures \u00e0 2.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2020-7564",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7564"
},
{
"name": "CVE-2020-7563",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7563"
},
{
"name": "CVE-2020-7558",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7558"
},
{
"name": "CVE-2020-7561",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7561"
},
{
"name": "CVE-2020-7555",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7555"
},
{
"name": "CVE-2020-7565",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7565"
},
{
"name": "CVE-2020-7570",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7570"
},
{
"name": "CVE-2020-7572",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7572"
},
{
"name": "CVE-2020-28213",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28213"
},
{
"name": "CVE-2020-7554",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7554"
},
{
"name": "CVE-2020-7557",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7557"
},
{
"name": "CVE-2020-7550",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7550"
},
{
"name": "CVE-2020-7553",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7553"
},
{
"name": "CVE-2020-7559",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7559"
},
{
"name": "CVE-2020-7566",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7566"
},
{
"name": "CVE-2020-7538",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7538"
},
{
"name": "CVE-2020-7556",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7556"
},
{
"name": "CVE-2020-28212",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28212"
},
{
"name": "CVE-2020-7562",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7562"
},
{
"name": "CVE-2020-7571",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7571"
},
{
"name": "CVE-2020-7552",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7552"
},
{
"name": "CVE-2020-28211",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28211"
},
{
"name": "CVE-2020-7551",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7551"
},
{
"name": "CVE-2020-7567",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7567"
},
{
"name": "CVE-2020-7544",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7544"
}
],
"links": [],
"reference": "CERTFR-2020-AVI-726",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2020-11-12T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider Electric. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de\nservice \u00e0 distance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider Electric",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-315-05 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-315-03 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-03/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-315-07 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-07/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-315-01 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-01/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-315-04 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-04/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-315-06 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-06/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-315-02 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-02/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SESB-2020-315-01 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SESB-2020-315-01/"
}
]
}
CERTFR-2020-AVI-726
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider Electric. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | N/A | Premium processors avec Ethernet COPRO intégré (TSXP574634, TSXP575634, TSXP576634) toutes versions | ||
| Schneider Electric | N/A | Modicon M221 toutes références et toutes versions | ||
| Schneider Electric | N/A | PLC Simulator for EcoStruxure Control Expert toutes versions | ||
| Schneider Electric | N/A | EcoStruxure Building Operation - WebStation versions v2.0 à v3.1 | ||
| Schneider Electric | N/A | Quantum communication modules (140NOE771x1, 140NOC78x00, 140NOC77101) toutes versions | ||
| Schneider Electric | N/A | J Data Radios toutes versions | ||
| Schneider Electric | N/A | PLC Simulator for Unity Pro (anciennement EcoStruxure Control Expert) toutes versions | ||
| Schneider Electric | N/A | EcoStruxure Operator Terminal Expert Runtime 3.1 Service Pack 1A et versions antérieures (les ordinateurs Windows utilisant un UEFI ne sont pas impactés) | ||
| Schneider Electric | N/A | M340 modules de communication Ethernet (BMX NOE 0100 (H), BMX NOE 0110 (H), BMX NOC 0401, BMX NOR 0200H) toutes versions | ||
| Schneider Electric | N/A | Quantum processors avec Ethernet COPRO intégré 140CPU65xxxxx toutes versions | ||
| Schneider Electric | N/A | M340 CPUs BMX P34x toutes versions | ||
| Schneider Electric | N/A | EcoStruxure Building Operation - Enterprise Server installer versions v1.9 à v3.1 | ||
| Schneider Electric | N/A | Trio Q toutes versions | ||
| Schneider Electric | N/A | EcoStruxure Building Operation - WebReports versions v1.9 à v3.1 | ||
| Schneider Electric | N/A | Premium communication modules (TSXETY4103, TSXETY5103) toutes versions | ||
| Schneider Electric | N/A | EcoStruxure Building Operation - Enterprise Central installer versions v2.0 à v3.1 | ||
| Schneider Electric | N/A | IGSS Definition (Def.exe) version 14.0.0.20247 et versions antérieures | ||
| Schneider Electric | N/A | Easergy T300 versions antérieures à 2.7 |
| Title | Publication Time | Tags | ||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Premium processors avec Ethernet COPRO int\u00e9gr\u00e9 (TSXP574634, TSXP575634, TSXP576634) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M221 toutes r\u00e9f\u00e9rences et toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "PLC Simulator for EcoStruxure Control Expert toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Building Operation - WebStation versions v2.0 \u00e0 v3.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Quantum communication modules (140NOE771x1, 140NOC78x00, 140NOC77101) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "J Data Radios toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "PLC Simulator for Unity Pro (anciennement EcoStruxure Control Expert) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Operator Terminal Expert Runtime 3.1 Service Pack 1A et versions ant\u00e9rieures (les ordinateurs Windows utilisant un UEFI ne sont pas impact\u00e9s)",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "M340 modules de communication Ethernet (BMX NOE 0100 (H), BMX NOE 0110 (H), BMX NOC 0401, BMX NOR 0200H) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Quantum processors avec Ethernet COPRO int\u00e9gr\u00e9 140CPU65xxxxx toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "M340 CPUs BMX P34x toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Building Operation - Enterprise Server installer versions v1.9 \u00e0 v3.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Trio Q toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Building Operation - WebReports versions v1.9 \u00e0 v3.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Premium communication modules (TSXETY4103, TSXETY5103) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure Building Operation - Enterprise Central installer versions v2.0 \u00e0 v3.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "IGSS Definition (Def.exe) version 14.0.0.20247 et versions ant\u00e9rieures",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Easergy T300 versions ant\u00e9rieures \u00e0 2.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2020-7564",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7564"
},
{
"name": "CVE-2020-7563",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7563"
},
{
"name": "CVE-2020-7558",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7558"
},
{
"name": "CVE-2020-7561",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7561"
},
{
"name": "CVE-2020-7555",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7555"
},
{
"name": "CVE-2020-7565",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7565"
},
{
"name": "CVE-2020-7570",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7570"
},
{
"name": "CVE-2020-7572",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7572"
},
{
"name": "CVE-2020-28213",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28213"
},
{
"name": "CVE-2020-7554",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7554"
},
{
"name": "CVE-2020-7557",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7557"
},
{
"name": "CVE-2020-7550",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7550"
},
{
"name": "CVE-2020-7553",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7553"
},
{
"name": "CVE-2020-7559",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7559"
},
{
"name": "CVE-2020-7566",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7566"
},
{
"name": "CVE-2020-7538",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7538"
},
{
"name": "CVE-2020-7556",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7556"
},
{
"name": "CVE-2020-28212",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28212"
},
{
"name": "CVE-2020-7562",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7562"
},
{
"name": "CVE-2020-7571",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7571"
},
{
"name": "CVE-2020-7552",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7552"
},
{
"name": "CVE-2020-28211",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28211"
},
{
"name": "CVE-2020-7551",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7551"
},
{
"name": "CVE-2020-7567",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7567"
},
{
"name": "CVE-2020-7544",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7544"
}
],
"links": [],
"reference": "CERTFR-2020-AVI-726",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2020-11-12T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider Electric. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de\nservice \u00e0 distance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider Electric",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-315-05 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-05/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-315-03 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-03/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-315-07 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-07/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-315-01 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-01/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-315-04 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-04/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-315-06 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-06/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2020-315-02 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-02/"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SESB-2020-315-01 du 11 novembre 2020",
"url": "https://www.se.com/ww/en/download/document/SESB-2020-315-01/"
}
]
}
GHSA-6P79-8657-J6HJ
Vulnerability from github – Published: 2022-05-24 22:28 – Updated: 2022-05-24 22:28A CWE-269 Improper Privilege Management vulnerability exists in EcoStruxureª Operator Terminal Expert runtime (Vijeo XD) that could cause privilege escalation on the workstation when interacting directly with a driver installed by the runtime software of EcoStruxureª Operator Terminal Expert.
{
"affected": [],
"aliases": [
"CVE-2020-7544"
],
"database_specific": {
"cwe_ids": [
"CWE-269"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2020-11-19T22:15:00Z",
"severity": "HIGH"
},
"details": "A CWE-269 Improper Privilege Management vulnerability exists in EcoStruxure\u00aa Operator Terminal Expert runtime (Vijeo XD) that could cause privilege escalation on the workstation when interacting directly with a driver installed by the runtime software of EcoStruxure\u00aa Operator Terminal Expert.",
"id": "GHSA-6p79-8657-j6hj",
"modified": "2022-05-24T22:28:19Z",
"published": "2022-05-24T22:28:19Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2020-7544"
},
{
"type": "WEB",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-02"
}
],
"schema_version": "1.4.0",
"severity": []
}
SEVD-2020-315-02
Vulnerability from csaf_se - Published: 2020-11-09 00:00 - Updated: 2021-01-11 00:00CWE-269 Improper Privilege Management vulnerability exists that could cause privilege escalation on the workstation when interacting directly with a driver installed by the runtime software of EcoStruxure™ Operator Terminal Expert or Pro-face BLUE or WinGP.
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Public",
"tlp": {
"label": "WHITE"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "We strongly recommend the following industry cybersecurity best practices.\n\nhttps://www.se.com/us/en/download/document/7EN52-0390/\n* Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.\n* Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.\n* Place all controllers in locked cabinets and never leave them in the \u201cProgram\u201d mode.\n* Never connect programming software to any network other than the network intended for that device.\n* Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.\n* Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.\n* Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet.\n* When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices.\nFor more information refer to the Schneider Electric Recommended Cybersecurity Best Practices document. \n",
"title": "General Security Recommendations"
},
{
"category": "general",
"text": "This document provides an overview of the identified vulnerability or vulnerabilities and actions required to mitigate. For more details and assistance on how to protect your installation, contact your local Schneider Electric representative or Schneider Electric Industrial Cybersecurity Services: https://www.se.com/ww/en/work/solutions/cybersecurity/. These organizations will be fully aware of this situation and can support you through the process.\nFor further information related to cybersecurity in Schneider Electric\u2019s products, visit the company\u2019s cybersecurity support portal page: https://www.se.com/ww/en/work/support/cybersecurity/overview.jsp",
"title": "For More Information"
},
{
"category": "legal_disclaimer",
"text": "THIS NOTIFICATION DOCUMENT, THE INFORMATION CONTAINED HEREIN, AND ANY MATERIALS LINKED FROM IT (COLLECTIVELY, THIS \u201cNOTIFICATION\u201d) ARE INTENDED TO HELP PROVIDE AN OVERVIEW OF THE IDENTIFIED SITUATION AND SUGGESTED MITIGATION ACTIONS, REMEDIATION, FIX, AND/OR GENERAL SECURITY RECOMMENDATIONS AND IS PROVIDED ON AN \u201cAS-IS\u201d BASIS WITHOUT WARRANTY OR GUARANTEE OF ANY KIND. SCHNEIDER ELECTRIC DISCLAIMS ALL WARRANTIES RELATING TO THIS NOTIFICATION, EITHER EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SCHNEIDER ELECTRIC MAKES NO WARRANTY THAT THE NOTIFICATION WILL RESOLVE THE IDENTIFIED SITUATION. IN NO EVENT SHALL SCHNEIDER ELECTRIC BE LIABLE FOR ANY DAMAGES OR LOSSES WHATSOEVER IN CONNECTION WITH THIS NOTIFICATION, INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF SCHNEIDER ELECTRIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. YOUR USE OF THIS NOTIFICATION IS AT YOUR OWN RISK, AND YOU ARE SOLELY LIABLE FOR ANY DAMAGES TO YOUR SYSTEMS OR ASSETS OR OTHER LOSSES THAT MAY RESULT FROM YOUR USE OF THIS NOTIFICATION. SCHNEIDER ELECTRIC RESERVES THE RIGHT TO UPDATE OR CHANGE THIS NOTIFICATION AT ANY TIME AND IN ITS SOLE DISCRETION",
"title": "LEGAL DISCLAIMER"
},
{
"category": "general",
"text": "At Schneider, we believe access to energy and digital is a basic human right. We empower all to do more with less, ensuring Life Is On everywhere, for everyone, at every moment.\n\nWe provide energy and automation digital solutions for efficiency and sustainability. We combine world-leading energy technologies, real-time automation, software and services into integrated solutions for Homes, Buildings, Data Centers, Infrastructure and Industries.\n\nWe are committed to unleash the infinite possibilities of an open, global, innovative community that is passionate with our Meaningful Purpose, Inclusive and Empowered values.\n\nwww.se.com ",
"title": "About Schneider Electric"
},
{
"category": "summary",
"text": "Schneider Electric is aware of a vulnerability in its EcoStruxure\u2122 Operator Terminal Expert \r\n(formerly known as Vijeo XD), Pro-face BLUE and WinGP runtimes. This vulnerability impacts \r\nWindows PC and Harmony iPC offers. \r\nThe EcoStruxure\u2122 Operator Terminal Expert and Pro-face BLUE products are HMI \r\nconfiguration software supporting gestures and UI designs. \r\nWinGP is a runtime engine on Windows PC and is included in Pro-face GP-Pro EX product\r\nwhich is an HMI Screen Editor \u0026 Logic Programming Software for Pro-face. \r\nFailure to apply the remediations provided below may risk unauthorized command execution by \r\na local user of the Windows engineering workstation, which could result in loss of availability, \r\nconfidentiality and integrity of the workstation where EcoStruxure\u2122 Operator Terminal Expert , \r\nPro-face BLUE or WinGP runtime is installed. \r\nJanuary 2021 update: Added Pro-face BLUE and WinGP to the list of products affected and \r\nlinks to the fixes",
"title": "Overview"
},
{
"category": "summary",
"text": "Customers should use appropriate patching methodologies when applying these patches to their systems. We strongly recommend the use of back-ups and evaluating the impact of these patches in a Test and Development environment or on an offline infrastructure. Contact Schneider Electric\u0027s Customer Care Center https://www.se.com/ww/en/work/services/field-services/industrial-automation/industrial-cybersecurity/industrial-cybersecurity.jsp or Pro-face\u0027s Customer Care Center https://www.proface.com/en/contact if you need assistance removing a patch.",
"title": "Overview"
}
],
"publisher": {
"category": "vendor",
"contact_details": "cpcert@se.com",
"name": "Schneider Electric CPCERT",
"namespace": "https://www.se.com/ww/en/work/support/cybersecurity/security-notifications.jsp"
},
"references": [
{
"category": "self",
"summary": "EcoStruxure\u2122 Operator Terminal Expert (Vijeo XD), Pro-face BLUE and WinGP runtime - SEVD-2020-315-02 PDF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2020-315-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2020-315-02_EcoStruxure%E2%84%A2%20Operator%20Terminal%20Expert_Security_Notification_V2.0.pdf"
},
{
"category": "self",
"summary": "EcoStruxure\u2122 Operator Terminal Expert (Vijeo XD), Pro-face BLUE and WinGP runtime - SEVD-2020-315-02 CSAF Version",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2020-315-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=sevd-2020-315-02.json"
},
{
"category": "external",
"summary": "Recommended Cybersecurity Best Practices",
"url": "https://www.se.com/us/en/download/document/7EN52-0390/"
}
],
"title": "EcoStruxure\u2122 Operator Terminal Expert (Vijeo XD), Pro-face BLUE and WinGP runtime",
"tracking": {
"current_release_date": "2021-01-11T00:00:00.000Z",
"generator": {
"date": "2021-01-11T00:00:00Z",
"engine": {
"name": "Schneider Electric CSAF Generator",
"version": "1.2"
}
},
"id": "SEVD-2020-315-02",
"initial_release_date": "2020-11-09T00:00:00.000Z",
"revision_history": [
{
"date": "2020-11-09T00:00:00.000Z",
"number": "1.0.0",
"summary": "Original Release"
},
{
"date": "2021-01-11T00:00:00.000Z",
"number": "2.0.0",
"summary": "Pro-face BLUE and WinGP added to list of \r\naffected products (page 1-2)"
}
],
"status": "final",
"version": "2.0.0"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=3.1 Service Pack 1A",
"product": {
"name": "Schneider Electric EcoStruxure\u2122 Operator Terminal Expert Runtime installed on Windows PC using legacy BIOS 3.1 Service Pack 1A and prior",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "EcoStruxure\u2122 Operator Terminal Expert Runtime installed on Windows PC using legacy BIOS"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=3.1 Service Pack 1A",
"product": {
"name": "Schneider Electric EcoStruxure\u2122 Operator Terminal Expert Runtime installed on Harmony iPC(HMIG3U) using legacy BIOS 3.1 Service Pack 1A and prior",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "EcoStruxure\u2122 Operator Terminal Expert Runtime installed on Harmony iPC(HMIG3U) using legacy BIOS"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=3.1 Service Pack 1A",
"product": {
"name": "Schneider Electric Pro-face BLUE Runtime installed on Windows PC using legacy BIOS 3.1 Service Pack 1A and prior",
"product_id": "3"
}
}
],
"category": "product_name",
"name": "Pro-face BLUE Runtime installed on Windows PC using legacy BIOS"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=3.1 Service Pack 1A",
"product": {
"name": "Schneider Electric Pro-face BLUE Runtime installed on Pro-face iPC (SP-5B10) using legacy BIOS 3.1 Service Pack 1A and prior",
"product_id": "4"
}
}
],
"category": "product_name",
"name": "Pro-face BLUE Runtime installed on Pro-face iPC (SP-5B10) using legacy BIOS"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=4.09.120",
"product": {
"name": "Schneider Electric WinGP installed on Windows PC using legacy BIOS V4.09.120 and prior",
"product_id": "5"
}
}
],
"category": "product_name",
"name": "WinGP installed on Windows PC using legacy BIOS"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c=4.09.120",
"product": {
"name": "Schneider Electric WinGP installed on Pro-face PS4000 \u0026 PS5000 series and SP-5B40, SP5B41 using legacy BIOS V4.09.120 and prior",
"product_id": "6"
}
}
],
"category": "product_name",
"name": "WinGP installed on Pro-face PS4000 \u0026 PS5000 series and SP-5B40, SP5B41 using legacy BIOS"
},
{
"branches": [
{
"category": "product_version",
"name": "3.1 Service Pack 1B",
"product": {
"name": "Schneider Electric EcoStruxure\u2122 Operator Terminal Expert V3.1 Service Pack 1B",
"product_id": "7"
}
}
],
"category": "product_name",
"name": "EcoStruxure\u2122 Operator Terminal Expert"
},
{
"branches": [
{
"category": "product_version",
"name": "3.1 Service Pack 1B",
"product": {
"name": "Schneider Electric Pro-face BLUE V3.1 Service Pack 1B",
"product_id": "8"
}
}
],
"category": "product_name",
"name": "Pro-face BLUE"
},
{
"branches": [
{
"category": "product_version",
"name": "4.09.200",
"product": {
"name": "Schneider Electric WinGP V4.09.200",
"product_id": "9"
}
}
],
"category": "product_name",
"name": "WinGP"
}
],
"category": "vendor",
"name": "Schneider Electric"
}
]
},
"vulnerabilities": [
{
"acknowledgments": [
{
"names": [
"Lasse Trolle Borup"
],
"organization": "Danish Cyber Defence"
}
],
"cve": "CVE-2020-7544",
"cwe": {
"id": "CWE-269",
"name": "Improper Privilege Management"
},
"notes": [
{
"category": "description",
"text": "CWE-269 Improper Privilege Management vulnerability exists that could cause privilege \r\nescalation on the workstation when interacting directly with a driver installed by the runtime \r\nsoftware of EcoStruxure\u2122 Operator Terminal Expert or Pro-face BLUE or WinGP. ",
"title": "CVE Description"
}
],
"product_status": {
"fixed": [
"7",
"8",
"9"
],
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6"
]
},
"remediations": [
{
"category": "vendor_fix",
"details": "\u2022 V3.1 Service Pack 1B of the EcoStruxure\u2122 Operator Terminal Expert includes a fix for \r\nthis vulnerability and is available for download here: https://www.se.com/ww/en/product\u0002range-download/62621-ecostruxure%E2%84%A2-operator-terminal-expert/#/software\u0002firmware-tab\r\no This fix is also available through Schneider Electric Software Update (SESU). Customers should use appropriate patching methodologies when applying these patches to their systems. We strongly recommend the use of back-ups and evaluating the impact of these patches in a Test and Development environment or on an offline infrastructure. Contact Schneider Electric\u0027s Customer Care Center https://www.se.com/ww/en/work/services/field-services/industrial-automation/industrial-cybersecurity/industrial-cybersecurity.jsp or Pro-face\u0027s Customer Care Center https://www.proface.com/en/contact if you need assistance removing a patch.",
"product_ids": [
"1",
"2"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/ww/en/product-range-download/62621-ecostruxure%E2%84%A2-operator-terminal-expert/#/software-firmware-tab"
},
{
"category": "vendor_fix",
"details": "V3.1 Service Pack 1B of the Pro-face BLUE includes a fix for this vulnerability and is \r\navailable for download here: https://www.proface.com/en/service#/page/installer/blue. Customers should use appropriate patching methodologies when applying these patches to their systems. We strongly recommend the use of back-ups and evaluating the impact of these patches in a Test and Development environment or on an offline infrastructure. Contact Schneider Electric\u0027s Customer Care Center https://www.se.com/ww/en/work/services/field-services/industrial-automation/industrial-cybersecurity/industrial-cybersecurity.jsp or Pro-face\u0027s Customer Care Center https://www.proface.com/en/contact if you need assistance removing a patch.",
"product_ids": [
"3",
"4"
],
"restart_required": {
"category": "none"
},
"url": "https://www.proface.com/en/service#/page/installer/blue"
},
{
"category": "vendor_fix",
"details": "V4.09.200 of the WinGP, included in GP-Pro EX, includes a fix for this vulnerability and is \r\navailable for download here: https://www.proface.com/en/download/trial/gpproex/v40\r\no Reinstall WinGP on the affected products. Customers should use appropriate patching methodologies when applying these patches to their systems. We strongly recommend the use of back-ups and evaluating the impact of these patches in a Test and Development environment or on an offline infrastructure. Contact Schneider Electric\u0027s Customer Care Center https://www.se.com/ww/en/work/services/field-services/industrial-automation/industrial-cybersecurity/industrial-cybersecurity.jsp or Pro-face\u0027s Customer Care Center https://www.proface.com/en/contact if you need assistance removing a patch.",
"product_ids": [
"5",
"6"
],
"restart_required": {
"category": "none"
},
"url": "https://www.proface.com/en/download/trial/gpproex/v40"
},
{
"category": "mitigation",
"details": "If customers choose not to apply the remediation provided above, they should immediately \r\napply the following mitigations to reduce the risk of exploit:\r\n\u2022 Use EcoStruxure\u2122 Operator Terminal Expert, Pro-face BLUE, or WinGP software only \r\non a trusted workstation.\r\n\u2022 Harden your workstation following the best cybersecurity practices (antivirus, updated \r\noperating systems, strong password policies, application White Listing software, etc.) \r\nusing the following guideline: https://www.se.com/us/en/download/document/CS-Best\u0002Practices-2019-340/\r\n\u2022 Use Windows PC with UEFI technology. Customers can identify if their PC uses the \r\nUEFI technology by using the following system command: msinfo32.exe provided by \r\nMicrosoft Windows. This command provides the system information. The section BIOS \r\nmode displays either \u201cUEFI\u201d or \u201cLEGACY\u201d. \r\no If the value is UEFI, the PC is not vulnerable, if the value is LEGACY then the \r\nPC is vulnerable\r\n",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6"
],
"restart_required": {
"category": "none"
},
"url": "https://www.se.com/us/en/download/document/CS-Best-Practices-2019-340/"
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.4,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6"
]
}
],
"title": "CVE-2020-7544"
}
]
}
ICSA-20-336-01
Vulnerability from csaf_cisa - Published: 2020-12-01 00:00 - Updated: 2020-12-01 00:00{
"document": {
"acknowledgments": [
{
"names": [
"Lasse Trolle Borup"
],
"organization": "Danish Cyber Defence",
"summary": "reporting this vulnerability to Schneider Electric"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
"title": "CISA Disclaimer"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "summary",
"text": "Successful exploitation of this vulnerability may allow unauthorized command execution by a local user of the Windows engineering workstation, which could result in loss of availability, confidentiality, and integrity of the workstation where EcoStruxure Operator Terminal Expert runtime is installed.",
"title": "Risk evaluation"
},
{
"category": "other",
"text": "Commercial Facilities, Energy, Food and Agriculture, Government Facilities, Transportation Systems, Water and Wastewater Systems",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "France",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA also recommends users take the following measures to protect themselves from social engineering attacks:",
"title": "Recommended Practices"
},
{
"category": "other",
"text": "No known public exploits specifically target this vulnerability. This vulnerability is not exploitable remotely. High skill level is needed to exploit.\n",
"title": "Exploitability"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-20-336-01 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2020/icsa-20-336-01.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-20-336-01 Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-20-336-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/ncas/tips/ST04-014"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/ics/tips/ICS-TIP-12-146-01B"
}
],
"title": "Schneider Electric EcoStruxure Operator Terminal Expert runtime (Vijeo XD)",
"tracking": {
"current_release_date": "2020-12-01T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-20-336-01",
"initial_release_date": "2020-12-01T00:00:00.000000Z",
"revision_history": [
{
"date": "2020-12-01T00:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "ICSA-20-336-01 Schneider Electric EcoStruxure Operator Terminal Expert runtime (Vijeo XD)"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c= 3.1 Service Pack 1A",
"product": {
"name": "Windows PC using legacy BIOS EcoStruxure Operator Terminal Expert Runtime: 3.1 Service Pack 1A and prior installed",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "Windows PC using legacy BIOS EcoStruxure Operator Terminal Expert Runtime"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c= 3.1 Service Pack 1A",
"product": {
"name": "Harmony iPC (HMIG5U HMIG5U2) using legacy BIOS EcoStruxure Operator Terminal Expert Runtime: 3.1 Service Pack 1A and prior installed",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "Harmony iPC (HMIG5U HMIG5U2) using legacy BIOS EcoStruxure Operator Terminal Expert Runtime"
}
],
"category": "vendor",
"name": "Schneider Electric Software, LLC"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2020-7544",
"cwe": {
"id": "CWE-269",
"name": "Improper Privilege Management"
},
"notes": [
{
"category": "summary",
"text": "An improper privilege management vulnerability exists that could cause privilege escalation on the workstation when interacting directly with a driver installed by the runtime software of EcoStruxure Operator Terminal Expert.CVE-2020-7544 has been assigned to this vulnerability. A CVSS v3 base score of 7.4 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H).",
"title": "Vulnerability Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-7544"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "mitigation",
"details": "Schneider Electric has prepared Version 3.1 Service Pack 1B of the EcoStruxure Operator Terminal Expert product with a fix for this vulnerability. This fix is also available through Schneider Electric Software Update (SESU). If users choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit:",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.se.com/ww/en/product-range-download/62621-ecostruxure%E2%84%A2-operator-terminal-expert/#/software-firmware-tab"
},
{
"category": "mitigation",
"details": "Use EcoStruxure Operator Terminal Expert runtime software only on a trusted workstation.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "Harden workstation following the best cybersecurity practices (antivirus, updated operating systems, strong password policies, application white listing software, etc.) by following Schneider Electric\u0027s best practices guidelines.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.se.com/us/en/download/document/CS-Best-Practices-2019-340/"
},
{
"category": "mitigation",
"details": "Use Windows PC with UEFI technology. Users can identify if their PC uses the UEFI technology by using the following system command: msinfo32.exe provided by Microsoft Windows. This command provides the system information. The section BIOS mode displays either \u201cUEFI\u201d or \u201cLEGACY\u201d. If the value is UEFI, the PC is not vulnerable, if the value is LEGACY then the PC is vulnerable.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "If the value is UEFI, the PC is not vulnerable, if the value is LEGACY then the PC is vulnerable.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "mitigation",
"details": "For further information please refer to SEVD-2020-315-02.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-02/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.4,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
}
]
}
GSD-2020-7544
Vulnerability from gsd - Updated: 2023-12-13 01:21{
"GSD": {
"alias": "CVE-2020-7544",
"description": "A CWE-269 Improper Privilege Management vulnerability exists in EcoStruxure\u00aa Operator Terminal Expert runtime (Vijeo XD) that could cause privilege escalation on the workstation when interacting directly with a driver installed by the runtime software of EcoStruxure\u00aa Operator Terminal Expert.",
"id": "GSD-2020-7544"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2020-7544"
],
"details": "A CWE-269 Improper Privilege Management vulnerability exists in EcoStruxure\u00aa Operator Terminal Expert runtime (Vijeo XD) that could cause privilege escalation on the workstation when interacting directly with a driver installed by the runtime software of EcoStruxure\u00aa Operator Terminal Expert.",
"id": "GSD-2020-7544",
"modified": "2023-12-13T01:21:51.466361Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2020-7544",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "EcoStruxure\u00aa Operator Terminal Expert runtime (Vijeo XD)",
"version": {
"version_data": [
{
"version_value": "EcoStruxure\u00aa Operator Terminal Expert runtime (Vijeo XD)"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-269 Improper Privilege Management vulnerability exists in EcoStruxure\u00aa Operator Terminal Expert runtime (Vijeo XD) that could cause privilege escalation on the workstation when interacting directly with a driver installed by the runtime software of EcoStruxure\u00aa Operator Terminal Expert."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-269:Improper Privilege Management"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-315-02/",
"refsource": "MISC",
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-02/"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:operator_terminal_expert_runtime:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "3.1",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:operator_terminal_expert_runtime:3.1:-:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:schneider-electric:operator_terminal_expert_runtime:3.1:service_pack_1a:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2020-7544"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A CWE-269 Improper Privilege Management vulnerability exists in EcoStruxure\u00aa Operator Terminal Expert runtime (Vijeo XD) that could cause privilege escalation on the workstation when interacting directly with a driver installed by the runtime software of EcoStruxure\u00aa Operator Terminal Expert."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-269"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.se.com/ww/en/download/document/SEVD-2020-315-02/",
"refsource": "MISC",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-02/"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 7.2,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 3.9,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"userInteractionRequired": false
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
}
},
"lastModifiedDate": "2022-01-31T19:33Z",
"publishedDate": "2020-11-19T22:15Z"
}
}
}
FKIE_CVE-2020-7544
Vulnerability from fkie_nvd - Published: 2020-11-19 22:15 - Updated: 2024-11-21 05:37| URL | Tags | ||
|---|---|---|---|
| cybersecurity@se.com | https://www.se.com/ww/en/download/document/SEVD-2020-315-02/ | Patch, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.se.com/ww/en/download/document/SEVD-2020-315-02/ | Patch, Vendor Advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| schneider-electric | operator_terminal_expert_runtime | * | |
| schneider-electric | operator_terminal_expert_runtime | 3.1 | |
| schneider-electric | operator_terminal_expert_runtime | 3.1 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:operator_terminal_expert_runtime:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F020516C-FCA9-45DC-918D-CF47B0B11579",
"versionEndExcluding": "3.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:schneider-electric:operator_terminal_expert_runtime:3.1:-:*:*:*:*:*:*",
"matchCriteriaId": "ADD60642-45DE-4B0E-AA5D-8A361CBB847D",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:schneider-electric:operator_terminal_expert_runtime:3.1:service_pack_1a:*:*:*:*:*:*",
"matchCriteriaId": "671669BD-DF16-453E-A36F-7AD109F2097E",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A CWE-269 Improper Privilege Management vulnerability exists in EcoStruxure\u00aa Operator Terminal Expert runtime (Vijeo XD) that could cause privilege escalation on the workstation when interacting directly with a driver installed by the runtime software of EcoStruxure\u00aa Operator Terminal Expert."
},
{
"lang": "es",
"value": "Se presenta una vulnerabilidad de Administraci\u00f3n de Privilegios Inapropiado CWE-269 en el tiempo de ejecuci\u00f3n de EcoStruxure\u00aa Operator Terminal Expert (Vijeo XD) que podr\u00eda causar una escalada de privilegios en la estaci\u00f3n de trabajo al interactuar directamente con un controlador instalado por el software de tiempo de ejecuci\u00f3n de EcoStruxure\u00aa Operator Terminal Expert"
}
],
"id": "CVE-2020-7544",
"lastModified": "2024-11-21T05:37:21.100",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 7.2,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 3.9,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-11-19T22:15:14.113",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-02/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.se.com/ww/en/download/document/SEVD-2020-315-02/"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-269"
}
],
"source": "cybersecurity@se.com",
"type": "Secondary"
}
]
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.