CVE-2021-37203 (GCVE-0-2021-37203)

Vulnerability from cvelistv5 – Published: 2021-09-14 10:47 – Updated: 2024-08-04 01:16
VLAI?
Summary
A vulnerability has been identified in NX 1980 Series (All versions < V1984), Solid Edge SE2021 (All versions < SE2021MP8). The plmxmlAdapterIFC.dll contains an out-of-bounds read while parsing user supplied IFC files which could result in a read past the end of an allocated buffer. This could allow an attacker to cause a denial-of-service condition or read sensitive information from memory locations.
Severity ?
No CVSS data available.
CWE
Assigner
Impacted products
Vendor Product Version
Siemens NX 1980 Series Affected: All versions < V1984
Create a notification for this product.
    Siemens Solid Edge SE2021 Affected: All versions < SE2021MP8
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T01:16:03.931Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-208530.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "NX 1980 Series",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1984"
            }
          ]
        },
        {
          "product": "Solid Edge SE2021",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c SE2021MP8"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in NX 1980 Series (All versions \u003c V1984), Solid Edge SE2021 (All versions \u003c SE2021MP8). The plmxmlAdapterIFC.dll contains an out-of-bounds read while parsing user supplied IFC files which could result in a read past the end of an allocated buffer. This could allow an attacker to cause a denial-of-service condition or read sensitive information from memory locations."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-09-28T11:12:26",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-208530.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-37203",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "NX 1980 Series",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V1984"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Solid Edge SE2021",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c SE2021MP8"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in NX 1980 Series (All versions \u003c V1984), Solid Edge SE2021 (All versions \u003c SE2021MP8). The plmxmlAdapterIFC.dll contains an out-of-bounds read while parsing user supplied IFC files which could result in a read past the end of an allocated buffer. This could allow an attacker to cause a denial-of-service condition or read sensitive information from memory locations."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-125: Out-of-bounds Read"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-208530.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-208530.pdf"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-37203",
    "datePublished": "2021-09-14T10:47:56",
    "dateReserved": "2021-07-21T00:00:00",
    "dateUpdated": "2024-08-04T01:16:03.931Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:nx_1980:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1984\", \"matchCriteriaId\": \"D3A09766-0171-4DDA-9BF9-D379DA134571\"}]}]}, {\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:solid_edge:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"se2021\", \"matchCriteriaId\": \"576A303A-66CA-4694-AA54-9EB0137C24F1\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:solid_edge:se2021:-:*:*:*:*:*:*\", \"matchCriteriaId\": \"39D237BD-EE55-4B40-ABC3-194C4BF7C6CD\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack1:*:*:*:*:*:*\", \"matchCriteriaId\": \"49F5649A-349C-42C6-AFFF-CEE1ABC14E67\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack2:*:*:*:*:*:*\", \"matchCriteriaId\": \"756343AA-DB57-40F7-94FA-84BFCDEB6159\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack3:*:*:*:*:*:*\", \"matchCriteriaId\": \"36B0DD28-653E-4069-AB5A-38F8EFEB36CA\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack4:*:*:*:*:*:*\", \"matchCriteriaId\": \"82090774-D894-41C8-82F1-A48A8707E9BB\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack5:*:*:*:*:*:*\", \"matchCriteriaId\": \"BD346D22-9B5D-4A50-94E2-1F5C8D391EC3\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack6:*:*:*:*:*:*\", \"matchCriteriaId\": \"1466AEE0-4A5C-4E2D-80B8-43680F60FC31\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack7:*:*:*:*:*:*\", \"matchCriteriaId\": \"A4173D09-C317-45FF-ABA4-39E5592862F8\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in NX 1980 Series (All versions \u003c V1984), Solid Edge SE2021 (All versions \u003c SE2021MP8). The plmxmlAdapterIFC.dll contains an out-of-bounds read while parsing user supplied IFC files which could result in a read past the end of an allocated buffer. This could allow an attacker to cause a denial-of-service condition or read sensitive information from memory locations.\"}, {\"lang\": \"es\", \"value\": \"Se ha identificado una vulnerabilidad en NX 1980 Series (Todas las versiones anteriores a V1984), Solid Edge SE2021 (Todas las versiones anteriores a SE2021MP8). El archivo plmxmlAdapterIFC.dll contiene una lectura fuera de l\\u00edmites al analizar los archivos IFC suministrados por el usuario, lo que podr\\u00eda dar lugar a una lectura m\\u00e1s all\\u00e1 del final de un b\\u00fafer asignado. Esto podr\\u00eda permitir a un atacante causar una condici\\u00f3n de denegaci\\u00f3n de servicio o leer informaci\\u00f3n sensible de ubicaciones de memoria\"}]",
      "id": "CVE-2021-37203",
      "lastModified": "2024-11-21T06:14:51.227",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H\", \"baseScore\": 7.1, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 5.2}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:N/C:P/I:N/A:P\", \"baseScore\": 5.8, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 8.6, \"impactScore\": 4.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": true}]}",
      "published": "2021-09-14T11:15:26.473",
      "references": "[{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-208530.pdf\", \"source\": \"productcert@siemens.com\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf\", \"source\": \"productcert@siemens.com\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-208530.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}]",
      "sourceIdentifier": "productcert@siemens.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"productcert@siemens.com\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-125\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2021-37203\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2021-09-14T11:15:26.473\",\"lastModified\":\"2024-11-21T06:14:51.227\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in NX 1980 Series (All versions \u003c V1984), Solid Edge SE2021 (All versions \u003c SE2021MP8). The plmxmlAdapterIFC.dll contains an out-of-bounds read while parsing user supplied IFC files which could result in a read past the end of an allocated buffer. This could allow an attacker to cause a denial-of-service condition or read sensitive information from memory locations.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en NX 1980 Series (Todas las versiones anteriores a V1984), Solid Edge SE2021 (Todas las versiones anteriores a SE2021MP8). El archivo plmxmlAdapterIFC.dll contiene una lectura fuera de l\u00edmites al analizar los archivos IFC suministrados por el usuario, lo que podr\u00eda dar lugar a una lectura m\u00e1s all\u00e1 del final de un b\u00fafer asignado. Esto podr\u00eda permitir a un atacante causar una condici\u00f3n de denegaci\u00f3n de servicio o leer informaci\u00f3n sensible de ubicaciones de memoria\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H\",\"baseScore\":7.1,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.2}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:N/A:P\",\"baseScore\":5.8,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":4.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-125\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:nx_1980:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1984\",\"matchCriteriaId\":\"D3A09766-0171-4DDA-9BF9-D379DA134571\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"se2021\",\"matchCriteriaId\":\"576A303A-66CA-4694-AA54-9EB0137C24F1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"39D237BD-EE55-4B40-ABC3-194C4BF7C6CD\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack1:*:*:*:*:*:*\",\"matchCriteriaId\":\"49F5649A-349C-42C6-AFFF-CEE1ABC14E67\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack2:*:*:*:*:*:*\",\"matchCriteriaId\":\"756343AA-DB57-40F7-94FA-84BFCDEB6159\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack3:*:*:*:*:*:*\",\"matchCriteriaId\":\"36B0DD28-653E-4069-AB5A-38F8EFEB36CA\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack4:*:*:*:*:*:*\",\"matchCriteriaId\":\"82090774-D894-41C8-82F1-A48A8707E9BB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack5:*:*:*:*:*:*\",\"matchCriteriaId\":\"BD346D22-9B5D-4A50-94E2-1F5C8D391EC3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack6:*:*:*:*:*:*\",\"matchCriteriaId\":\"1466AEE0-4A5C-4E2D-80B8-43680F60FC31\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack7:*:*:*:*:*:*\",\"matchCriteriaId\":\"A4173D09-C317-45FF-ABA4-39E5592862F8\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-208530.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-208530.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…