CVE-2021-40160 (GCVE-0-2021-40160)

Vulnerability from cvelistv5 – Published: 2021-12-23 18:31 – Updated: 2024-08-04 02:27
VLAI
Summary
PDFTron prior to 9.0.7 version may be forced to read beyond allocated boundaries when parsing a maliciously crafted PDF file. This vulnerability can be exploited to execute arbitrary code.
CWE
  • Out-of-bound Read Vulnerability
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T02:27:31.871Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.autodesk.com/trust/security-advisories/adsk-sa-2021-0010"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Revit, Navisworks, Autodesk\u00ae Advance Steel, AutoCAD\u00ae, AutoCAD\u00ae Architecture, AutoCAD\u00ae Electrical, AutoCAD\u00ae Map 3D, AutoCAD\u00ae Mechanical, AutoCAD\u00ae MEP, AutoCAD\u00ae Plant 3D, AutoCAD\u00ae LT,  Autodesk\u00ae Civil 3D, AutoCAD\u00ae Mac, AutoCAD\u00ae LT for Mac",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "prior to 9.0.7"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "PDFTron prior to 9.0.7 version may be forced to read beyond allocated boundaries when parsing a maliciously crafted PDF file. This vulnerability can be exploited to execute arbitrary code."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Out-of-bound Read Vulnerability",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-18T16:20:48.000Z",
        "orgId": "7e40ea87-bc65-4944-9723-dd79dd760601",
        "shortName": "autodesk"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.autodesk.com/trust/security-advisories/adsk-sa-2021-0010"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@autodesk.com",
          "ID": "CVE-2021-40160",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Revit, Navisworks, Autodesk\u00ae Advance Steel, AutoCAD\u00ae, AutoCAD\u00ae Architecture, AutoCAD\u00ae Electrical, AutoCAD\u00ae Map 3D, AutoCAD\u00ae Mechanical, AutoCAD\u00ae MEP, AutoCAD\u00ae Plant 3D, AutoCAD\u00ae LT,  Autodesk\u00ae Civil 3D, AutoCAD\u00ae Mac, AutoCAD\u00ae LT for Mac",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "prior to 9.0.7"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "PDFTron prior to 9.0.7 version may be forced to read beyond allocated boundaries when parsing a maliciously crafted PDF file. This vulnerability can be exploited to execute arbitrary code."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Out-of-bound Read Vulnerability"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.autodesk.com/trust/security-advisories/adsk-sa-2021-0010",
              "refsource": "MISC",
              "url": "https://www.autodesk.com/trust/security-advisories/adsk-sa-2021-0010"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7e40ea87-bc65-4944-9723-dd79dd760601",
    "assignerShortName": "autodesk",
    "cveId": "CVE-2021-40160",
    "datePublished": "2021-12-23T18:31:31.000Z",
    "dateReserved": "2021-08-27T00:00:00.000Z",
    "dateUpdated": "2024-08-04T02:27:31.871Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2021-40160",
      "date": "2026-08-15",
      "epss": "0.0154",
      "percentile": "0.72752"
    },
    "fkie_nvd": {
      "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:autodesk:revit:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"2020\", \"versionEndExcluding\": \"2020.2.5\", \"matchCriteriaId\": \"6DCAF9B0-8B1F-4625-B04F-DECB699C9770\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:autodesk:revit:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"2021\", \"versionEndExcluding\": \"2021.1.4\", \"matchCriteriaId\": \"A9BBB8FC-C689-4DF6-B79D-248C0144A5EC\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:autodesk:revit:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"2022\", \"versionEndExcluding\": \"2022.1\", \"matchCriteriaId\": \"A29624C7-516C-4E7E-B1FE-43ED3188BC70\"}]}]}, {\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:autodesk:navisworks:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"2019\", \"versionEndExcluding\": \"2019.6\", \"matchCriteriaId\": \"70EC1A64-F7DD-4835-969F-A9051F06CB60\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:autodesk:navisworks:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"2020\", \"versionEndExcluding\": \"2020.4\", \"matchCriteriaId\": \"FB5C1908-9829-46DE-881F-57277490BE71\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:autodesk:navisworks:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"2021\", \"versionEndExcluding\": \"2021.3\", \"matchCriteriaId\": \"AE821566-76A8-43D6-9628-B82CFE9FAC19\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:autodesk:navisworks:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"2022\", \"versionEndExcluding\": \"2022.1\", \"matchCriteriaId\": \"CE0E4388-28DB-4D72-BA69-882A121C8C9A\"}]}]}, {\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:autodesk:advance_steel:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"2022\", \"versionEndExcluding\": \"2022.1.1\", \"matchCriteriaId\": \"67E62F6D-C9D2-4129-A25A-468F150BA2CB\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:autodesk:autocad:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"2022\", \"versionEndExcluding\": \"2022.1.1\", \"matchCriteriaId\": \"4104E0A8-E133-41F9-A60A-368FD2DCC1A3\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:autodesk:autocad:*:*:*:*:*:macos:*:*\", \"versionStartIncluding\": \"2022\", \"versionEndExcluding\": \"2022.2\", \"matchCriteriaId\": \"F7B0B566-F23E-4637-8611-8D055A90F421\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:autodesk:autocad_architecture:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"2022\", \"versionEndExcluding\": \"2022.1.1\", \"matchCriteriaId\": \"D42D33AA-39DC-4B60-A87F-2B9A41390EDA\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:autodesk:autocad_electrical:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"2022\", \"versionEndExcluding\": \"2022.1.1\", \"matchCriteriaId\": \"D2D4CB47-D77A-4ACA-A606-3E7880729E0C\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:autodesk:autocad_lt:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"2022\", \"versionEndExcluding\": \"2022.1.1\", \"matchCriteriaId\": \"E813870A-AAB5-491F-8ECA-587432AD9935\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:autodesk:autocad_lt:*:*:*:*:*:macos:*:*\", \"versionStartIncluding\": \"2022\", \"versionEndExcluding\": \"2022.2\", \"matchCriteriaId\": \"FF16B57E-C704-43BE-94F5-F09493257323\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:autodesk:autocad_map_3d:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"2022\", \"versionEndExcluding\": \"2022.1.1\", \"matchCriteriaId\": \"1172D845-0F80-45EC-95D6-911556D4032D\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:autodesk:autocad_mechanical:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"2022\", \"versionEndExcluding\": \"2022.1.1\", \"matchCriteriaId\": \"047BD11C-74A7-47AA-A593-BAACD00D2B89\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:autodesk:autocad_mep:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"2022\", \"versionEndExcluding\": \"2022.1.1\", \"matchCriteriaId\": \"C926403A-E06B-45A7-9693-CF0B78C7C627\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:autodesk:autocad_plant_3d:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"2022\", \"versionEndExcluding\": \"2022.1.1\", \"matchCriteriaId\": \"C3807591-D6E0-4BB6-9573-C318A9D4EF60\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:autodesk:civil_3d:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"2022\", \"versionEndExcluding\": \"2022.1.1\", \"matchCriteriaId\": \"B4C8F3C7-F830-4138-99BD-064F969E4929\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:autodesk:design_review:2018:-:*:*:*:*:*:*\", \"matchCriteriaId\": \"213232B9-A40B-436D-A66A-B65C49D59BE6\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:autodesk:design_review:2018:hotfix:*:*:*:*:*:*\", \"matchCriteriaId\": \"2D0CF4DC-ACA5-41D0-B28E-CEB5D2C96F71\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:autodesk:design_review:2018:hotfix2:*:*:*:*:*:*\", \"matchCriteriaId\": \"84ED1789-A17F-48F7-A152-09D2A5C59254\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:autodesk:design_review:2018:hotfix3:*:*:*:*:*:*\", \"matchCriteriaId\": \"74819924-EB63-4BBF-9986-FEF6100EEE15\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:autodesk:design_review:2018:hotfix4:*:*:*:*:*:*\", \"matchCriteriaId\": \"100922EF-C773-4798-B352-B16FCAD48F36\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"PDFTron prior to 9.0.7 version may be forced to read beyond allocated boundaries when parsing a maliciously crafted PDF file. This vulnerability can be exploited to execute arbitrary code.\"}, {\"lang\": \"es\", \"value\": \"PDFTron antes de la versi\\u00f3n 9.0.7 puede ser forzado a leer m\\u00e1s all\\u00e1 de los l\\u00edmites asignados al analizar un archivo PDF malicioso. Esta vulnerabilidad puede ser explotada para ejecutar c\\u00f3digo arbitrario\"}]",
      "id": "CVE-2021-40160",
      "lastModified": "2024-11-21T06:23:41.700",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\", \"baseScore\": 7.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:N/C:P/I:P/A:P\", \"baseScore\": 6.8, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 8.6, \"impactScore\": 6.4, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": true}]}",
      "published": "2021-12-23T19:15:12.117",
      "references": "[{\"url\": \"https://www.autodesk.com/trust/security-advisories/adsk-sa-2021-0010\", \"source\": \"psirt@autodesk.com\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}, {\"url\": \"https://www.autodesk.com/trust/security-advisories/adsk-sa-2021-0010\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}]",
      "sourceIdentifier": "psirt@autodesk.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-125\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2021-40160\",\"sourceIdentifier\":\"psirt@autodesk.com\",\"published\":\"2021-12-23T19:15:12.117\",\"lastModified\":\"2026-06-17T04:06:36.857\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"PDFTron prior to 9.0.7 version may be forced to read beyond allocated boundaries when parsing a maliciously crafted PDF file. This vulnerability can be exploited to execute arbitrary code.\"},{\"lang\":\"es\",\"value\":\"PDFTron antes de la versi\u00f3n 9.0.7 puede ser forzado a leer m\u00e1s all\u00e1 de los l\u00edmites asignados al analizar un archivo PDF malicioso. Esta vulnerabilidad puede ser explotada para ejecutar c\u00f3digo arbitrario\"}],\"affected\":[{\"source\":\"psirt@autodesk.com\",\"affectedData\":[{\"vendor\":\"n/a\",\"product\":\"Revit, Navisworks, Autodesk\u00ae Advance Steel, AutoCAD\u00ae, AutoCAD\u00ae Architecture, AutoCAD\u00ae Electrical, AutoCAD\u00ae Map 3D, AutoCAD\u00ae Mechanical, AutoCAD\u00ae MEP, AutoCAD\u00ae Plant 3D, AutoCAD\u00ae LT,  Autodesk\u00ae Civil 3D, AutoCAD\u00ae Mac, AutoCAD\u00ae LT for Mac\",\"versions\":[{\"version\":\"prior to 9.0.7\",\"status\":\"affected\"}]}]}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:P\",\"baseScore\":6.8,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-125\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:revit:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2020\",\"versionEndExcluding\":\"2020.2.5\",\"matchCriteriaId\":\"6DCAF9B0-8B1F-4625-B04F-DECB699C9770\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:revit:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2021\",\"versionEndExcluding\":\"2021.1.4\",\"matchCriteriaId\":\"A9BBB8FC-C689-4DF6-B79D-248C0144A5EC\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:revit:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2022\",\"versionEndExcluding\":\"2022.1\",\"matchCriteriaId\":\"A29624C7-516C-4E7E-B1FE-43ED3188BC70\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:navisworks:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2019\",\"versionEndExcluding\":\"2019.6\",\"matchCriteriaId\":\"70EC1A64-F7DD-4835-969F-A9051F06CB60\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:navisworks:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2020\",\"versionEndExcluding\":\"2020.4\",\"matchCriteriaId\":\"FB5C1908-9829-46DE-881F-57277490BE71\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:navisworks:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2021\",\"versionEndExcluding\":\"2021.3\",\"matchCriteriaId\":\"AE821566-76A8-43D6-9628-B82CFE9FAC19\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:navisworks:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2022\",\"versionEndExcluding\":\"2022.1\",\"matchCriteriaId\":\"CE0E4388-28DB-4D72-BA69-882A121C8C9A\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:advance_steel:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2022\",\"versionEndExcluding\":\"2022.1.1\",\"matchCriteriaId\":\"67E62F6D-C9D2-4129-A25A-468F150BA2CB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2022\",\"versionEndExcluding\":\"2022.1.1\",\"matchCriteriaId\":\"4104E0A8-E133-41F9-A60A-368FD2DCC1A3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad:*:*:*:*:*:macos:*:*\",\"versionStartIncluding\":\"2022\",\"versionEndExcluding\":\"2022.2\",\"matchCriteriaId\":\"F7B0B566-F23E-4637-8611-8D055A90F421\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_architecture:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2022\",\"versionEndExcluding\":\"2022.1.1\",\"matchCriteriaId\":\"D42D33AA-39DC-4B60-A87F-2B9A41390EDA\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_electrical:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2022\",\"versionEndExcluding\":\"2022.1.1\",\"matchCriteriaId\":\"D2D4CB47-D77A-4ACA-A606-3E7880729E0C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_lt:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2022\",\"versionEndExcluding\":\"2022.1.1\",\"matchCriteriaId\":\"E813870A-AAB5-491F-8ECA-587432AD9935\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_lt:*:*:*:*:*:macos:*:*\",\"versionStartIncluding\":\"2022\",\"versionEndExcluding\":\"2022.2\",\"matchCriteriaId\":\"FF16B57E-C704-43BE-94F5-F09493257323\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_map_3d:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2022\",\"versionEndExcluding\":\"2022.1.1\",\"matchCriteriaId\":\"1172D845-0F80-45EC-95D6-911556D4032D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_mechanical:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2022\",\"versionEndExcluding\":\"2022.1.1\",\"matchCriteriaId\":\"047BD11C-74A7-47AA-A593-BAACD00D2B89\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_mep:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2022\",\"versionEndExcluding\":\"2022.1.1\",\"matchCriteriaId\":\"C926403A-E06B-45A7-9693-CF0B78C7C627\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_plant_3d:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2022\",\"versionEndExcluding\":\"2022.1.1\",\"matchCriteriaId\":\"C3807591-D6E0-4BB6-9573-C318A9D4EF60\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:civil_3d:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2022\",\"versionEndExcluding\":\"2022.1.1\",\"matchCriteriaId\":\"B4C8F3C7-F830-4138-99BD-064F969E4929\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:design_review:2018:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"213232B9-A40B-436D-A66A-B65C49D59BE6\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:design_review:2018:hotfix:*:*:*:*:*:*\",\"matchCriteriaId\":\"2D0CF4DC-ACA5-41D0-B28E-CEB5D2C96F71\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:design_review:2018:hotfix2:*:*:*:*:*:*\",\"matchCriteriaId\":\"84ED1789-A17F-48F7-A152-09D2A5C59254\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:design_review:2018:hotfix3:*:*:*:*:*:*\",\"matchCriteriaId\":\"74819924-EB63-4BBF-9986-FEF6100EEE15\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:design_review:2018:hotfix4:*:*:*:*:*:*\",\"matchCriteriaId\":\"100922EF-C773-4798-B352-B16FCAD48F36\"}]}]}],\"references\":[{\"url\":\"https://www.autodesk.com/trust/security-advisories/adsk-sa-2021-0010\",\"source\":\"psirt@autodesk.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://www.autodesk.com/trust/security-advisories/adsk-sa-2021-0010\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}",
    "redhat_vex": {
      "current_release_date": "2026-03-27T13:35:26+00:00",
      "cve": "CVE-2021-40160",
      "id": "CVE-2021-40160",
      "initial_release_date": "2021-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "CVE-2021-40160",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2021/cve-2021-40160.json",
      "version": "3"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Loading…