Advantech iView
Summary
The affected product is vulnerable to two instances of command injection, which may allow an attacker to remotely execute arbitrary code.
SSVC
Exploitation: poc Automatable: yes Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-04-16 15:51 UTC
CWE
  • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
References
Impacted products
Vendor Product Version CPE status
Advantech iView iView Affected: All , < 5_7_04_6469 (custom)
guessed Create a notification for this product.
Date Public
2022-06-28 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T00:24:44.411Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-179-03"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://packetstormsecurity.com/files/168108/Advantech-iView-NetworkServlet-Command-Injection.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-2143",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T15:51:23.088062Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T16:13:52.871Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "iView",
          "vendor": "Advantech iView",
          "versions": [
            {
              "lessThan": "5_7_04_6469",
              "status": "affected",
              "version": "All",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "rgod, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA"
        }
      ],
      "datePublic": "2022-06-28T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "The affected product is vulnerable to two instances of command injection, which may allow an attacker to remotely execute arbitrary code."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-18T18:06:17.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-179-03"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://packetstormsecurity.com/files/168108/Advantech-iView-NetworkServlet-Command-Injection.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Advantech recommends updating firmware to Version 5_7_4_6469 to address these vulnerabilities."
        }
      ],
      "source": {
        "advisory": "ICSA-22-179-03",
        "discovery": "EXTERNAL"
      },
      "title": "Advantech iView",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2022-06-28T17:00:00.000Z",
          "ID": "CVE-2022-2143",
          "STATE": "PUBLIC",
          "TITLE": "Advantech iView"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "iView",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "All",
                            "version_value": "5_7_04_6469"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Advantech iView"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "rgod, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The affected product is vulnerable to two instances of command injection, which may allow an attacker to remotely execute arbitrary code."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-179-03",
              "refsource": "MISC",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-179-03"
            },
            {
              "name": "http://packetstormsecurity.com/files/168108/Advantech-iView-NetworkServlet-Command-Injection.html",
              "refsource": "MISC",
              "url": "http://packetstormsecurity.com/files/168108/Advantech-iView-NetworkServlet-Command-Injection.html"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Advantech recommends updating firmware to Version 5_7_4_6469 to address these vulnerabilities."
          }
        ],
        "source": {
          "advisory": "ICSA-22-179-03",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-2143",
    "datePublished": "2022-07-22T14:59:13.360Z",
    "dateReserved": "2022-06-20T00:00:00.000Z",
    "dateUpdated": "2025-04-16T16:13:52.871Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2022-2143",
      "date": "2026-09-16",
      "epss": "0.59406",
      "percentile": "0.99071"
    },
    "fkie_nvd": {
      "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:advantech:iview:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"5.7.04.6469\", \"matchCriteriaId\": \"EC3EA62D-5DEE-46D5-BA3D-BD9F745F1191\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"The affected product is vulnerable to two instances of command injection, which may allow an attacker to remotely execute arbitrary code.\"}, {\"lang\": \"es\", \"value\": \"El producto afectado es vulnerable a dos instancias de inyecci\\u00f3n de comandos, que pueden permitir a un atacante ejecutar remotamente c\\u00f3digo arbitrario\"}]",
      "id": "CVE-2022-2143",
      "lastModified": "2024-11-21T07:00:25.093",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"ics-cert@hq.dhs.gov\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 9.8, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.9}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 9.8, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.9}]}",
      "published": "2022-07-22T15:15:08.463",
      "references": "[{\"url\": \"http://packetstormsecurity.com/files/168108/Advantech-iView-NetworkServlet-Command-Injection.html\", \"source\": \"ics-cert@hq.dhs.gov\", \"tags\": [\"Exploit\", \"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://www.cisa.gov/uscert/ics/advisories/icsa-22-179-03\", \"source\": \"ics-cert@hq.dhs.gov\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}, {\"url\": \"http://packetstormsecurity.com/files/168108/Advantech-iView-NetworkServlet-Command-Injection.html\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Exploit\", \"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://www.cisa.gov/uscert/ics/advisories/icsa-22-179-03\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}]",
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"ics-cert@hq.dhs.gov\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-77\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"NVD-CWE-Other\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2022-2143\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2022-07-22T15:15:08.463\",\"lastModified\":\"2026-06-17T04:41:23.300\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"The affected product is vulnerable to two instances of command injection, which may allow an attacker to remotely execute arbitrary code.\"},{\"lang\":\"es\",\"value\":\"El producto afectado es vulnerable a dos instancias de inyecci\u00f3n de comandos, que pueden permitir a un atacante ejecutar remotamente c\u00f3digo arbitrario\"}],\"affected\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"affectedData\":[{\"vendor\":\"Advantech iView\",\"product\":\"iView\",\"versions\":[{\"version\":\"All\",\"lessThan\":\"5_7_04_6469\",\"versionType\":\"custom\",\"status\":\"affected\"}]}]}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"ssvcV203\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"ssvcData\":{\"timestamp\":\"2025-04-16T15:51:23.088062Z\",\"id\":\"CVE-2022-2143\",\"options\":[{\"exploitation\":\"poc\"},{\"automatable\":\"yes\"},{\"technicalImpact\":\"total\"}],\"role\":\"CISA Coordinator\",\"version\":\"2.0.3\"}}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-77\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-Other\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:advantech:iview:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"5.7.04.6469\",\"matchCriteriaId\":\"EC3EA62D-5DEE-46D5-BA3D-BD9F745F1191\"}]}]}],\"references\":[{\"url\":\"http://packetstormsecurity.com/files/168108/Advantech-iView-NetworkServlet-Command-Injection.html\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Exploit\",\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://www.cisa.gov/uscert/ics/advisories/icsa-22-179-03\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"http://packetstormsecurity.com/files/168108/Advantech-iView-NetworkServlet-Command-Injection.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://www.cisa.gov/uscert/ics/advisories/icsa-22-179-03\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}",
    "redhat_vex": {
      "current_release_date": "2025-05-29T02:40:10+00:00",
      "cve": "CVE-2022-2143",
      "id": "CVE-2022-2143",
      "initial_release_date": "2022-06-28T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "Advantech iView",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2022/cve-2022-2143.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.cisa.gov/uscert/ics/advisories/icsa-22-179-03\", \"tags\": [\"x_refsource_MISC\", \"x_transferred\"]}, {\"url\": \"http://packetstormsecurity.com/files/168108/Advantech-iView-NetworkServlet-Command-Injection.html\", \"tags\": [\"x_refsource_MISC\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-03T00:24:44.411Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2022-2143\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"poc\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-04-16T15:51:23.088062Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-04-16T15:51:30.882Z\"}}], \"cna\": {\"title\": \"Advantech iView\", \"source\": {\"advisory\": \"ICSA-22-179-03\", \"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"value\": \"rgod, working with Trend Micro\\u2019s Zero Day Initiative, reported these vulnerabilities to CISA\"}], \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 9.8, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}}], \"affected\": [{\"vendor\": \"Advantech iView\", \"product\": \"iView\", \"versions\": [{\"status\": \"affected\", \"version\": \"All\", \"lessThan\": \"5_7_04_6469\", \"versionType\": \"custom\"}]}], \"solutions\": [{\"lang\": \"en\", \"value\": \"Advantech recommends updating firmware to Version 5_7_4_6469 to address these vulnerabilities.\"}], \"datePublic\": \"2022-06-28T00:00:00.000Z\", \"references\": [{\"url\": \"https://www.cisa.gov/uscert/ics/advisories/icsa-22-179-03\", \"tags\": [\"x_refsource_MISC\"]}, {\"url\": \"http://packetstormsecurity.com/files/168108/Advantech-iView-NetworkServlet-Command-Injection.html\", \"tags\": [\"x_refsource_MISC\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.0.9\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"The affected product is vulnerable to two instances of command injection, which may allow an attacker to remotely execute arbitrary code.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-77\", \"description\": \"CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"shortName\": \"icscert\", \"dateUpdated\": \"2022-08-18T18:06:17.000Z\"}, \"x_legacyV4Record\": {\"credit\": [{\"lang\": \"eng\", \"value\": \"rgod, working with Trend Micro\\u2019s Zero Day Initiative, reported these vulnerabilities to CISA\"}], \"impact\": {\"cvss\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 9.8, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}}, \"source\": {\"advisory\": \"ICSA-22-179-03\", \"discovery\": \"EXTERNAL\"}, \"affects\": {\"vendor\": {\"vendor_data\": [{\"product\": {\"product_data\": [{\"version\": {\"version_data\": [{\"version_name\": \"All\", \"version_value\": \"5_7_04_6469\", \"version_affected\": \"\u003c\"}]}, \"product_name\": \"iView\"}]}, \"vendor_name\": \"Advantech iView\"}]}}, \"solution\": [{\"lang\": \"en\", \"value\": \"Advantech recommends updating firmware to Version 5_7_4_6469 to address these vulnerabilities.\"}], \"data_type\": \"CVE\", \"generator\": {\"engine\": \"Vulnogram 0.0.9\"}, \"references\": {\"reference_data\": [{\"url\": \"https://www.cisa.gov/uscert/ics/advisories/icsa-22-179-03\", \"name\": \"https://www.cisa.gov/uscert/ics/advisories/icsa-22-179-03\", \"refsource\": \"MISC\"}, {\"url\": \"http://packetstormsecurity.com/files/168108/Advantech-iView-NetworkServlet-Command-Injection.html\", \"name\": \"http://packetstormsecurity.com/files/168108/Advantech-iView-NetworkServlet-Command-Injection.html\", \"refsource\": \"MISC\"}]}, \"data_format\": \"MITRE\", \"description\": {\"description_data\": [{\"lang\": \"eng\", \"value\": \"The affected product is vulnerable to two instances of command injection, which may allow an attacker to remotely execute arbitrary code.\"}]}, \"problemtype\": {\"problemtype_data\": [{\"description\": [{\"lang\": \"eng\", \"value\": \"CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)\"}]}]}, \"data_version\": \"4.0\", \"CVE_data_meta\": {\"ID\": \"CVE-2022-2143\", \"STATE\": \"PUBLIC\", \"TITLE\": \"Advantech iView\", \"ASSIGNER\": \"ics-cert@hq.dhs.gov\", \"DATE_PUBLIC\": \"2022-06-28T17:00:00.000Z\"}}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2022-2143\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-04-16T16:13:52.871Z\", \"dateReserved\": \"2022-06-20T00:00:00.000Z\", \"assignerOrgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"datePublished\": \"2022-07-22T14:59:13.360Z\", \"assignerShortName\": \"icscert\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…