cve-2022-24378
Vulnerability from cvelistv5
Published
2022-08-18 19:53
Modified
2024-08-03 04:07
Severity ?
Summary
Improper initialization in the Intel(R) Data Center Manager software before version 4.1 may allow an authenticated user to potentially enable denial of service via local access.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:07:02.597Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00662.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Intel(R) Data Center Manager software",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "before version 4.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper initialization in the Intel(R) Data Center Manager software before version 4.1 may allow an authenticated user to potentially enable denial of service via local access."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "denial of service",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-18T19:53:03",
        "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "shortName": "intel"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00662.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@intel.com",
          "ID": "CVE-2022-24378",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Intel(R) Data Center Manager software",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "before version 4.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Improper initialization in the Intel(R) Data Center Manager software before version 4.1 may allow an authenticated user to potentially enable denial of service via local access."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "denial of service"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00662.html",
              "refsource": "MISC",
              "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00662.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
    "assignerShortName": "intel",
    "cveId": "CVE-2022-24378",
    "datePublished": "2022-08-18T19:53:03",
    "dateReserved": "2022-02-18T00:00:00",
    "dateUpdated": "2024-08-03T04:07:02.597Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:intel:data_center_manager:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.1\", \"matchCriteriaId\": \"EEAB9092-370A-477B-94B9-F61106881285\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"Improper initialization in the Intel(R) Data Center Manager software before version 4.1 may allow an authenticated user to potentially enable denial of service via local access.\"}, {\"lang\": \"es\", \"value\": \"Una inicializaci\\u00f3n inapropiada en el software Intel(R) Data Center Manager versiones anteriores a 4.1, puede permitir que un usuario autenticado habilite potencialmente la denegaci\\u00f3n de servicio por medio del acceso local.\"}]",
      "id": "CVE-2022-24378",
      "lastModified": "2024-11-21T06:50:17.857",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\", \"baseScore\": 5.5, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 3.6}]}",
      "published": "2022-08-18T20:15:10.600",
      "references": "[{\"url\": \"https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00662.html\", \"source\": \"secure@intel.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00662.html\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
      "sourceIdentifier": "secure@intel.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-665\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2022-24378\",\"sourceIdentifier\":\"secure@intel.com\",\"published\":\"2022-08-18T20:15:10.600\",\"lastModified\":\"2024-11-21T06:50:17.857\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Improper initialization in the Intel(R) Data Center Manager software before version 4.1 may allow an authenticated user to potentially enable denial of service via local access.\"},{\"lang\":\"es\",\"value\":\"Una inicializaci\u00f3n inapropiada en el software Intel(R) Data Center Manager versiones anteriores a 4.1, puede permitir que un usuario autenticado habilite potencialmente la denegaci\u00f3n de servicio por medio del acceso local.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":5.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-665\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:intel:data_center_manager:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.1\",\"matchCriteriaId\":\"EEAB9092-370A-477B-94B9-F61106881285\"}]}]}],\"references\":[{\"url\":\"https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00662.html\",\"source\":\"secure@intel.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00662.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.