var-202208-1937
Vulnerability from variot
Improper initialization in the Intel(R) Data Center Manager software before version 4.1 may allow an authenticated user to potentially enable denial of service via local access. Intel's Intel Data Center Manager Has an initialization vulnerability.Service operation interruption (DoS) It may be in a state. Collects and analyzes real-time health, power and heat of various devices in the data center to help improve efficiency and uptime
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202208-1937", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "data center manager", "scope": "lt", "trust": 1.0, "vendor": "intel", "version": "4.1" }, { "model": "intel data center manager", "scope": null, "trust": 0.8, "vendor": "\u30a4\u30f3\u30c6\u30eb", "version": null }, { "model": "intel data center manager", "scope": "eq", "trust": 0.8, "vendor": "\u30a4\u30f3\u30c6\u30eb", "version": "4.1" }, { "model": "intel data center manager", "scope": "eq", "trust": 0.8, "vendor": "\u30a4\u30f3\u30c6\u30eb", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-015188" }, { "db": "NVD", "id": "CVE-2022-24378" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:intel:data_center_manager:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.1", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2022-24378" } ] }, "cve": "CVE-2022-24378", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "exploitabilityScore": 1.8, "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Local", "author": "NVD", "availabilityImpact": "High", "baseScore": 5.5, "baseSeverity": "Medium", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2022-24378", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "Low", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2022-24378", "trust": 1.8, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202208-3406", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-015188" }, { "db": "NVD", "id": "CVE-2022-24378" }, { "db": "CNNVD", "id": "CNNVD-202208-3406" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Improper initialization in the Intel(R) Data Center Manager software before version 4.1 may allow an authenticated user to potentially enable denial of service via local access. Intel\u0027s Intel Data Center Manager Has an initialization vulnerability.Service operation interruption (DoS) It may be in a state. Collects and analyzes real-time health, power and heat of various devices in the data center to help improve efficiency and uptime", "sources": [ { "db": "NVD", "id": "CVE-2022-24378" }, { "db": "JVNDB", "id": "JVNDB-2022-015188" }, { "db": "VULHUB", "id": "VHN-415333" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-24378", "trust": 3.3 }, { "db": "JVN", "id": "JVNVU99494206", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2022-015188", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202208-3406", "trust": 0.7 }, { "db": "AUSCERT", "id": "ESB-2022.3942.2", "trust": 0.6 }, { "db": "VULHUB", "id": "VHN-415333", "trust": 0.1 } ], "sources": [ { "db": "VULHUB", "id": "VHN-415333" }, { "db": "JVNDB", "id": "JVNDB-2022-015188" }, { "db": "NVD", "id": "CVE-2022-24378" }, { "db": "CNNVD", "id": "CNNVD-202208-3406" } ] }, "id": "VAR-202208-1937", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VULHUB", "id": "VHN-415333" } ], "trust": 0.01 }, "last_update_date": "2023-12-18T10:43:58.547000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Intel Data Center Manager Security vulnerabilities", "trust": 0.6, "url": "http://123.124.177.30/web/xxk/bdxqbyid.tag?id=205103" } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202208-3406" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-665", "trust": 1.1 }, { "problemtype": "Improper initialization (CWE-665) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "VULHUB", "id": "VHN-415333" }, { "db": "JVNDB", "id": "JVNDB-2022-015188" }, { "db": "NVD", "id": "CVE-2022-24378" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00662.html" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu99494206/" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2022-24378" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2022.3942.2" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-24378/" } ], "sources": [ { "db": "VULHUB", "id": "VHN-415333" }, { "db": "JVNDB", "id": "JVNDB-2022-015188" }, { "db": "NVD", "id": "CVE-2022-24378" }, { "db": "CNNVD", "id": "CNNVD-202208-3406" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULHUB", "id": "VHN-415333" }, { "db": "JVNDB", "id": "JVNDB-2022-015188" }, { "db": "NVD", "id": "CVE-2022-24378" }, { "db": "CNNVD", "id": "CNNVD-202208-3406" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-08-18T00:00:00", "db": "VULHUB", "id": "VHN-415333" }, { "date": "2023-09-25T00:00:00", "db": "JVNDB", "id": "JVNDB-2022-015188" }, { "date": "2022-08-18T20:15:10.600000", "db": "NVD", "id": "CVE-2022-24378" }, { "date": "2022-08-18T00:00:00", "db": "CNNVD", "id": "CNNVD-202208-3406" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-08-19T00:00:00", "db": "VULHUB", "id": "VHN-415333" }, { "date": "2023-09-25T08:46:00", "db": "JVNDB", "id": "JVNDB-2022-015188" }, { "date": "2022-08-19T20:04:21.067000", "db": "NVD", "id": "CVE-2022-24378" }, { "date": "2023-03-28T00:00:00", "db": "CNNVD", "id": "CNNVD-202208-3406" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202208-3406" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Intel\u0027s \u00a0Intel\u00a0Data\u00a0Center\u00a0Manager\u00a0 Initialization vulnerability in", "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-015188" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202208-3406" } ], "trust": 0.6 } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.