cve-2022-26509
Vulnerability from cvelistv5
Published
2023-02-16 19:59
Modified
2024-08-03 05:03
Severity ?
EPSS score ?
Summary
Improper conditions check in the Intel(R) SGX SDK software may allow a privileged user to potentially enable information disclosure via local access.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | n/a | Intel(R) SGX SDK software |
Version: See references |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T05:03:32.953Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "http://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00677.html", "tags": [ "x_transferred" ], "url": "http://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00677.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Intel(R) SGX SDK software", "vendor": "n/a", "versions": [ { "status": "affected", "version": "See references" } ] } ], "descriptions": [ { "lang": "en", "value": "Improper conditions check in the Intel(R) SGX SDK software may allow a privileged user to potentially enable information disclosure via local access." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 2.5, "baseSeverity": "LOW", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:L/I:N/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "description": "information disclosure", "lang": "en" } ] } ], "providerMetadata": { "dateUpdated": "2023-02-16T19:59:51.439Z", "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce", "shortName": "intel" }, "references": [ { "name": "http://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00677.html", "url": "http://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00677.html" } ] } }, "cveMetadata": { "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce", "assignerShortName": "intel", "cveId": "CVE-2022-26509", "datePublished": "2023-02-16T19:59:51.439Z", "dateReserved": "2022-04-05T15:11:17.491Z", "dateUpdated": "2024-08-03T05:03:32.953Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "fkie_nvd": { "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:intel:sgx_sdk:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"2.16.100.1\", \"matchCriteriaId\": \"0EC0D204-C10C-48FF-97D0-231E7C65DC50\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:o:linux:linux_kernel:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"703AF700-7A70-47E2-BC3A-7FD03B3CA9C1\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:intel:sgx_sdk:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"2.15.100.1\", \"matchCriteriaId\": \"DD795319-D7D3-470E-86E1-E3D4F5280B5B\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:o:microsoft:windows:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"A2572D17-1DE6-457B-99CC-64AFD54487EA\"}]}]}]", "descriptions": "[{\"lang\": \"en\", \"value\": \"Improper conditions check in the Intel(R) SGX SDK software may allow a privileged user to potentially enable information disclosure via local access.\"}]", "id": "CVE-2022-26509", "lastModified": "2024-11-21T06:54:05.180", "metrics": "{\"cvssMetricV31\": [{\"source\": \"secure@intel.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:L/I:N/A:N\", \"baseScore\": 2.5, \"baseSeverity\": \"LOW\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"HIGH\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"NONE\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 0.8, \"impactScore\": 1.4}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\", \"baseScore\": 5.5, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 3.6}]}", "published": "2023-02-16T20:15:13.310", "references": "[{\"url\": \"http://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00677.html\", \"source\": \"secure@intel.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"http://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00677.html\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]", "sourceIdentifier": "secure@intel.com", "vulnStatus": "Modified", "weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-755\"}]}]" }, "nvd": "{\"cve\":{\"id\":\"CVE-2022-26509\",\"sourceIdentifier\":\"secure@intel.com\",\"published\":\"2023-02-16T20:15:13.310\",\"lastModified\":\"2024-11-21T06:54:05.180\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Improper conditions check in the Intel(R) SGX SDK software may allow a privileged user to potentially enable information disclosure via local access.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"secure@intel.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:L/I:N/A:N\",\"baseScore\":2.5,\"baseSeverity\":\"LOW\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":0.8,\"impactScore\":1.4},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":5.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.8,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-755\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:intel:sgx_sdk:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.16.100.1\",\"matchCriteriaId\":\"0EC0D204-C10C-48FF-97D0-231E7C65DC50\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:linux:linux_kernel:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"703AF700-7A70-47E2-BC3A-7FD03B3CA9C1\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:intel:sgx_sdk:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.15.100.1\",\"matchCriteriaId\":\"DD795319-D7D3-470E-86E1-E3D4F5280B5B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A2572D17-1DE6-457B-99CC-64AFD54487EA\"}]}]}],\"references\":[{\"url\":\"http://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00677.html\",\"source\":\"secure@intel.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00677.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.