CVE-2022-33138 (GCVE-0-2022-33138)

Vulnerability from cvelistv5 – Published: 2022-07-12 10:06 – Updated: 2024-08-03 08:01
VLAI?
Summary
A vulnerability has been identified in SIMATIC MV540 H (All versions < V3.3), SIMATIC MV540 S (All versions < V3.3), SIMATIC MV550 H (All versions < V3.3), SIMATIC MV550 S (All versions < V3.3), SIMATIC MV560 U (All versions < V3.3), SIMATIC MV560 X (All versions < V3.3). Affected devices do not perform authentication for several web API endpoints. This could allow an unauthenticated remote attacker to read and download data from the device.
Severity ?
No CVSS data available.
CWE
  • CWE-306 - Missing Authentication for Critical Function
Assigner
References
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T08:01:19.531Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-348662.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SIMATIC MV540 H",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3"
            }
          ]
        },
        {
          "product": "SIMATIC MV540 S",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3"
            }
          ]
        },
        {
          "product": "SIMATIC MV550 H",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3"
            }
          ]
        },
        {
          "product": "SIMATIC MV550 S",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3"
            }
          ]
        },
        {
          "product": "SIMATIC MV560 U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3"
            }
          ]
        },
        {
          "product": "SIMATIC MV560 X",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC MV540 H (All versions \u003c V3.3), SIMATIC MV540 S (All versions \u003c V3.3), SIMATIC MV550 H (All versions \u003c V3.3), SIMATIC MV550 S (All versions \u003c V3.3), SIMATIC MV560 U (All versions \u003c V3.3), SIMATIC MV560 X (All versions \u003c V3.3). Affected devices do not perform authentication for several web API endpoints. This could allow an unauthenticated remote attacker to read and download data from the device."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306: Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-07-12T10:06:46",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-348662.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-33138",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC MV540 H",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC MV540 S",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC MV550 H",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC MV550 S",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC MV560 U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC MV560 X",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.3"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SIMATIC MV540 H (All versions \u003c V3.3), SIMATIC MV540 S (All versions \u003c V3.3), SIMATIC MV550 H (All versions \u003c V3.3), SIMATIC MV550 S (All versions \u003c V3.3), SIMATIC MV560 U (All versions \u003c V3.3), SIMATIC MV560 X (All versions \u003c V3.3). Affected devices do not perform authentication for several web API endpoints. This could allow an unauthenticated remote attacker to read and download data from the device."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-306: Missing Authentication for Critical Function"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-348662.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-348662.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-33138",
    "datePublished": "2022-07-12T10:06:46",
    "dateReserved": "2022-06-13T00:00:00",
    "dateUpdated": "2024-08-03T08:01:19.531Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_mv540_h_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"3.3\", \"matchCriteriaId\": \"A6527D89-4A8F-4A97-B2E9-CFBC9593DEB7\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_mv540_h:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"18944887-DE3F-4FB4-88D2-1C8EC89A1481\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_mv540_s_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"3.3\", \"matchCriteriaId\": \"0557AB45-C9F1-4F67-BD8D-E5AD706CCACF\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_mv540_s:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"4B016178-2DCB-417C-B20F-8B9E1904BE8C\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_mv550_h_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"3.3\", \"matchCriteriaId\": \"7EFEE0CC-F494-4B57-8DF1-68954C4AA144\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_mv550_h:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"324A87A6-2DC6-4797-8191-0BE2D8D1F9FC\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_mv550_s_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"3.3\", \"matchCriteriaId\": \"AC4115D9-D589-4EE4-AFC8-D3C103A84DA2\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_mv550_s:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"4B6E1134-8C21-4045-BD02-F44250474C40\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_mv560_u_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"3.3\", \"matchCriteriaId\": \"E9DEAF0E-48DB-4499-835B-96E17B8DD738\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_mv560_u:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"D2FBB8F8-C886-4A2B-8808-6E3D6A57B271\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_mv560_x_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"3.3\", \"matchCriteriaId\": \"99359BFA-BBA9-423F-A12B-1E9AF673CB91\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_mv560_x:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"DAA25C73-59D0-469D-BE6F-6188F645C1D9\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in SIMATIC MV540 H (All versions \u003c V3.3), SIMATIC MV540 S (All versions \u003c V3.3), SIMATIC MV550 H (All versions \u003c V3.3), SIMATIC MV550 S (All versions \u003c V3.3), SIMATIC MV560 U (All versions \u003c V3.3), SIMATIC MV560 X (All versions \u003c V3.3). Affected devices do not perform authentication for several web API endpoints. This could allow an unauthenticated remote attacker to read and download data from the device.\"}, {\"lang\": \"es\", \"value\": \"Se ha identificado una vulnerabilidad en SIMATIC MV540 H (Todas las versiones anteriores a V3.3), SIMATIC MV540 S (Todas las versiones anteriores a V3.3), SIMATIC MV550 H (Todas las versiones anteriores a V3.3), SIMATIC MV550 S (Todas las versiones anteriores a V3.3), SIMATIC MV560 U (Todas las versiones anteriores a V3.3), SIMATIC MV560 X (Todas las versiones anteriores a V3.3). Los dispositivos afectados no llevan a cabo la autenticaci\\u00f3n para varios endpoints de la API web. Esto podr\\u00eda permitir a un atacante remoto no autenticado leer y descargar datos del dispositivo\"}]",
      "id": "CVE-2022-33138",
      "lastModified": "2024-11-21T07:07:35.183",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.6}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:P/I:N/A:N\", \"baseScore\": 5.0, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 10.0, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
      "published": "2022-07-12T10:15:10.757",
      "references": "[{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-348662.pdf\", \"source\": \"productcert@siemens.com\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-348662.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}]",
      "sourceIdentifier": "productcert@siemens.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"productcert@siemens.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-306\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-306\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2022-33138\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2022-07-12T10:15:10.757\",\"lastModified\":\"2024-11-21T07:07:35.183\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SIMATIC MV540 H (All versions \u003c V3.3), SIMATIC MV540 S (All versions \u003c V3.3), SIMATIC MV550 H (All versions \u003c V3.3), SIMATIC MV550 S (All versions \u003c V3.3), SIMATIC MV560 U (All versions \u003c V3.3), SIMATIC MV560 X (All versions \u003c V3.3). Affected devices do not perform authentication for several web API endpoints. This could allow an unauthenticated remote attacker to read and download data from the device.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en SIMATIC MV540 H (Todas las versiones anteriores a V3.3), SIMATIC MV540 S (Todas las versiones anteriores a V3.3), SIMATIC MV550 H (Todas las versiones anteriores a V3.3), SIMATIC MV550 S (Todas las versiones anteriores a V3.3), SIMATIC MV560 U (Todas las versiones anteriores a V3.3), SIMATIC MV560 X (Todas las versiones anteriores a V3.3). Los dispositivos afectados no llevan a cabo la autenticaci\u00f3n para varios endpoints de la API web. Esto podr\u00eda permitir a un atacante remoto no autenticado leer y descargar datos del dispositivo\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:N/A:N\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-306\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-306\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_mv540_h_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.3\",\"matchCriteriaId\":\"A6527D89-4A8F-4A97-B2E9-CFBC9593DEB7\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_mv540_h:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"18944887-DE3F-4FB4-88D2-1C8EC89A1481\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_mv540_s_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.3\",\"matchCriteriaId\":\"0557AB45-C9F1-4F67-BD8D-E5AD706CCACF\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_mv540_s:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4B016178-2DCB-417C-B20F-8B9E1904BE8C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_mv550_h_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.3\",\"matchCriteriaId\":\"7EFEE0CC-F494-4B57-8DF1-68954C4AA144\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_mv550_h:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"324A87A6-2DC6-4797-8191-0BE2D8D1F9FC\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_mv550_s_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.3\",\"matchCriteriaId\":\"AC4115D9-D589-4EE4-AFC8-D3C103A84DA2\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_mv550_s:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4B6E1134-8C21-4045-BD02-F44250474C40\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_mv560_u_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.3\",\"matchCriteriaId\":\"E9DEAF0E-48DB-4499-835B-96E17B8DD738\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_mv560_u:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D2FBB8F8-C886-4A2B-8808-6E3D6A57B271\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_mv560_x_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.3\",\"matchCriteriaId\":\"99359BFA-BBA9-423F-A12B-1E9AF673CB91\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_mv560_x:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DAA25C73-59D0-469D-BE6F-6188F645C1D9\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-348662.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-348662.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…