Summary
Dell PowerScale OneFS, versions 8.2.0.x-9.4.0.x contain allocation of Resources Without Limits or Throttling vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to denial of service and performance issue on that node.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T09:07:16.247Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000204053/dsa-2022-245-dell-emc-powerscale-onefs-security-update-for-multiple-security-updates"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "PowerScale OneFS",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "9.4.0.x",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-10-13T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell PowerScale OneFS, versions 8.2.0.x-9.4.0.x contain allocation of Resources Without Limits or Throttling vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to denial of service and performance issue on that node."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-770",
              "description": "CWE-770: Allocation of Resources Without Limits or Throttling",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-10-21T00:00:00",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "url": "https://www.dell.com/support/kbdoc/en-us/000204053/dsa-2022-245-dell-emc-powerscale-onefs-security-update-for-multiple-security-updates"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2022-34439",
    "datePublished": "2022-10-21T18:05:29.268221Z",
    "dateReserved": "2022-06-23T00:00:00",
    "dateUpdated": "2024-09-16T16:22:45.210Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2022-34439\",\"sourceIdentifier\":\"security_alert@emc.com\",\"published\":\"2022-10-21T18:15:10.030\",\"lastModified\":\"2022-10-24T15:30:18.490\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"Dell PowerScale OneFS, versions 8.2.0.x-9.4.0.x contain allocation of Resources Without Limits or Throttling vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability, leading to denial of service and performance issue on that node.\"},{\"lang\":\"es\",\"value\":\"Dell PowerScale OneFS, versiones 8.2.0.x-9.4.0.x contienen una vulnerabilidad de Asignaci\u00f3n de Recursos sin L\u00edmites o Estrangulamiento. Un atacante remoto no autenticado podr\u00eda explotar esta vulnerabilidad, conllevando a una denegaci\u00f3n de servicio y un problema de rendimiento en ese nodo\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6},{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"LOW\",\"baseScore\":5.3,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":3.9,\"impactScore\":1.4}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-770\"}]},{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-770\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:emc_powerscale_onefs:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"9.1.0.0\",\"versionEndIncluding\":\"9.1.0.22\",\"matchCriteriaId\":\"3D268161-3C5F-49F8-A6FA-B9A3882FE305\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:emc_powerscale_onefs:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"9.2.1.0\",\"versionEndIncluding\":\"9.2.1.16\",\"matchCriteriaId\":\"4A3AA726-B6D4-4B39-B7D6-0E0270FB33E5\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:emc_powerscale_onefs:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"9.3.0.0\",\"versionEndIncluding\":\"9.3.0.7\",\"matchCriteriaId\":\"A4FB1971-36EC-4A19-B0DE-C11D6D5E2AA0\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:emc_powerscale_onefs:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"9.4.0.0\",\"versionEndIncluding\":\"9.4.0.5\",\"matchCriteriaId\":\"0A86357E-80E6-42A3-9048-4F84D80165A4\"}]}]}],\"references\":[{\"url\":\"https://www.dell.com/support/kbdoc/en-us/000204053/dsa-2022-245-dell-emc-powerscale-onefs-security-update-for-multiple-security-updates\",\"source\":\"security_alert@emc.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.