A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists that could cause loading of unauthorized firmware images due to improper verification of the firmware signature. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V2.01 and later), OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior)
CWE
  • CWE-345 - Insufficient Verification of Data Authenticity
References
Impacted products
Vendor Product Version CPE status
Schneider Electric OPC UA Modicon Communication Module Affected: BMENUA0100 , < V1.10 (custom)
guessed Create a notification for this product.
Schneider Electric X80 advanced RTU Communication Module Affected: V2.01 , < BMENOR2200H* (custom)
guessed Create a notification for this product.
Date Public
2022-07-12 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T09:22:10.447Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-193-01_OPC_UA_X80_Advanced_RTU_Modicon_Communication_Modules+_Security_Notification.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "OPC UA Modicon Communication Module",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "lessThan": "V1.10",
              "status": "affected",
              "version": "BMENUA0100",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "X80 advanced RTU Communication Module",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "lessThan": "BMENOR2200H*",
              "status": "affected",
              "version": "V2.01",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-07-12T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists that could cause loading of unauthorized firmware images due to improper verification of the firmware signature. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V2.01 and later), OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior)"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-345",
              "description": "CWE-345 Insufficient Verification of Data Authenticity",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-07-13T21:11:02.000Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-193-01_OPC_UA_X80_Advanced_RTU_Modicon_Communication_Modules+_Security_Notification.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "DATE_PUBLIC": "2022-07-12T11:00:00.000Z",
          "ID": "CVE-2022-34763",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "OPC UA Modicon Communication Module",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "BMENUA0100",
                            "version_value": "V1.10"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "X80 advanced RTU Communication Module",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003e",
                            "version_name": "BMENOR2200H",
                            "version_value": "V2.01"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Schneider Electric"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists that could cause loading of unauthorized firmware images due to improper verification of the firmware signature. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V2.01 and later), OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior)"
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-345 Insufficient Verification of Data Authenticity"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-193-01_OPC_UA_X80_Advanced_RTU_Modicon_Communication_Modules+_Security_Notification.pdf",
              "refsource": "MISC",
              "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-193-01_OPC_UA_X80_Advanced_RTU_Modicon_Communication_Modules+_Security_Notification.pdf"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2022-34763",
    "datePublished": "2022-07-13T21:11:02.182Z",
    "dateReserved": "2022-06-28T00:00:00.000Z",
    "dateUpdated": "2024-09-16T18:59:40.882Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2022-34763",
      "date": "2026-09-19",
      "epss": "0.00279",
      "percentile": "0.20645"
    },
    "fkie_nvd": {
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:opc_ua_module_for_m580_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3C0FE426-148B-4E23-8434-3E9A3F1943D2",
                  "versionEndIncluding": "1.10",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:opc_ua_module_for_m580:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3C43DE37-0241-4A43-B761-0A1F2D2684A3",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:schneider-electric:x80_advanced_rtu_module_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6FA21E71-EF69-48C5-845B-44FA1D65DF20",
                  "versionStartIncluding": "2.01",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:schneider-electric:x80_advanced_rtu_module:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CDD764FE-9165-41E9-9328-93A519CFDB99",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists that could cause loading of unauthorized firmware images due to improper verification of the firmware signature. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V2.01 and later), OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior)"
        },
        {
          "lang": "es",
          "value": "Una CWE-345: Se presenta una vulnerabilidad de Verificaci\u00f3n Insuficiente de la Autenticidad de los Datos que podr\u00eda causar la carga de im\u00e1genes de firmware no autorizadas debido a la verificaci\u00f3n incorrecta de la firma del firmware. Productos afectados: X80 advanced RTU Communication Module (BMENOR2200H) (versiones V2.01 y posteriores), OPC UA Modicon Communication Module (BMENUA0100) (versiones V1.10 y anteriores)"
        }
      ],
      "id": "CVE-2022-34763",
      "lastModified": "2024-11-21T07:10:08.413",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "HIGH",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 5.9,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "HIGH",
              "privilegesRequired": "HIGH",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:N/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 0.7,
            "impactScore": 5.2,
            "source": "cybersecurity@se.com",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2022-07-13T21:15:08.690",
      "references": [
        {
          "source": "cybersecurity@se.com",
          "tags": [
            "Patch",
            "Vendor Advisory"
          ],
          "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-193-01_OPC_UA_X80_Advanced_RTU_Modicon_Communication_Modules+_Security_Notification.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Patch",
            "Vendor Advisory"
          ],
          "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-193-01_OPC_UA_X80_Advanced_RTU_Modicon_Communication_Modules+_Security_Notification.pdf"
        }
      ],
      "sourceIdentifier": "cybersecurity@se.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-345"
            }
          ],
          "source": "cybersecurity@se.com",
          "type": "Primary"
        }
      ]
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "product": "OPC UA Modicon Communication Module",
                "vendor": "Schneider Electric",
                "versions": [
                  {
                    "lessThan": "V1.10",
                    "status": "affected",
                    "version": "BMENUA0100",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "product": "X80 advanced RTU Communication Module",
                "vendor": "Schneider Electric",
                "versions": [
                  {
                    "lessThan": "BMENOR2200H*",
                    "status": "affected",
                    "version": "V2.01",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "source": "cybersecurity@se.com"
          }
        ],
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:schneider-electric:opc_ua_module_for_m580_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "3C0FE426-148B-4E23-8434-3E9A3F1943D2",
                    "versionEndIncluding": "1.10",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:schneider-electric:opc_ua_module_for_m580:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "3C43DE37-0241-4A43-B761-0A1F2D2684A3",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:schneider-electric:x80_advanced_rtu_module_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "6FA21E71-EF69-48C5-845B-44FA1D65DF20",
                    "versionStartIncluding": "2.01",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:schneider-electric:x80_advanced_rtu_module:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "CDD764FE-9165-41E9-9328-93A519CFDB99",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists that could cause loading of unauthorized firmware images due to improper verification of the firmware signature. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V2.01 and later), OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior)"
          },
          {
            "lang": "es",
            "value": "Una CWE-345: Se presenta una vulnerabilidad de Verificaci\u00f3n Insuficiente de la Autenticidad de los Datos que podr\u00eda causar la carga de im\u00e1genes de firmware no autorizadas debido a la verificaci\u00f3n incorrecta de la firma del firmware. Productos afectados: X80 advanced RTU Communication Module (BMENOR2200H) (versiones V2.01 y posteriores), OPC UA Modicon Communication Module (BMENUA0100) (versiones V1.10 y anteriores)"
          }
        ],
        "id": "CVE-2022-34763",
        "lastModified": "2026-06-17T04:50:53.020",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:N/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 0.7,
              "impactScore": 5.2,
              "source": "cybersecurity@se.com",
              "type": "Secondary"
            },
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 3.6,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ]
        },
        "published": "2022-07-13T21:15:08.690",
        "references": [
          {
            "source": "cybersecurity@se.com",
            "tags": [
              "Patch",
              "Vendor Advisory"
            ],
            "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-193-01_OPC_UA_X80_Advanced_RTU_Modicon_Communication_Modules+_Security_Notification.pdf"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Patch",
              "Vendor Advisory"
            ],
            "url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-193-01_OPC_UA_X80_Advanced_RTU_Modicon_Communication_Modules+_Security_Notification.pdf"
          }
        ],
        "sourceIdentifier": "cybersecurity@se.com",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-345"
              }
            ],
            "source": "cybersecurity@se.com",
            "type": "Secondary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2026-03-27T12:15:00+00:00",
      "cve": "CVE-2022-34763",
      "id": "CVE-2022-34763",
      "initial_release_date": "2022-07-12T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "CVE-2022-34763",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2022/cve-2022-34763.json",
      "version": "3"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…