Action not permitted
Modal body text goes here.
Modal Title
Modal Body
cve-2022-37889
Vulnerability from cvelistv5
Vendor | Product | Version | |
---|---|---|---|
▼ | n/a | Aruba Access Points: 100 Series; 103 Series; 110 Series; 120 Series; 130 Series; 200 Series; 207 Series; 210 Series; 220 Series; 260 Series; 300 Series; 303 Series; 310 Series; 318 Series Hardened Access Points; 320 Series; 330 Series; 340 Series; 370 Series; 500 Series; 510 Series; 530 Series; 550 Series; 630 Series; 650 Series; |
Version: Aruba InstantOS 6.4.x: 6.4.4.8-4.2.4.20 and below Version: Aruba InstantOS 6.5.x: 6.5.4.23 and below Version: Aruba InstantOS 8.6.x: 8.6.0.18 and below Version: Aruba InstantOS 8.7.x: 8.7.1.9 and below Version: Aruba InstantOS 8.10.x: 8.10.0.1 and below Version: ArubaOS 10.3.x: 10.3.1.0 and below |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T10:37:41.984Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2022-014.txt" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-506569.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Aruba Access Points: 100 Series; 103 Series; 110 Series; 120 Series; 130 Series; 200 Series; 207 Series; 210 Series; 220 Series; 260 Series; 300 Series; 303 Series; 310 Series; 318 Series Hardened Access Points; 320 Series; 330 Series; 340 Series; 370 Series; 500 Series; 510 Series; 530 Series; 550 Series; 630 Series; 650 Series;", "vendor": "n/a", "versions": [ { "status": "affected", "version": "Aruba InstantOS 6.4.x: 6.4.4.8-4.2.4.20 and below" }, { "status": "affected", "version": "Aruba InstantOS 6.5.x: 6.5.4.23 and below" }, { "status": "affected", "version": "Aruba InstantOS 8.6.x: 8.6.0.18 and below" }, { "status": "affected", "version": "Aruba InstantOS 8.7.x: 8.7.1.9 and below" }, { "status": "affected", "version": "Aruba InstantOS 8.10.x: 8.10.0.1 and below" }, { "status": "affected", "version": "ArubaOS 10.3.x: 10.3.1.0 and below" } ] } ], "descriptions": [ { "lang": "en", "value": "There are buffer overflow vulnerabilities in multiple underlying services that could lead to unauthenticated remote code execution by sending specially crafted packets destined to the PAPI (Aruba Networks AP management protocol) UDP port (8211). Successful exploitation of these vulnerabilities results in the ability to execute arbitrary code as a privileged user on the underlying operating system of Aruba InstantOS 6.4.x: 6.4.4.8-4.2.4.20 and below; Aruba InstantOS 6.5.x: 6.5.4.23 and below; Aruba InstantOS 8.6.x: 8.6.0.18 and below; Aruba InstantOS 8.7.x: 8.7.1.9 and below; Aruba InstantOS 8.10.x: 8.10.0.1 and below; ArubaOS 10.3.x: 10.3.1.0 and below; Aruba has released upgrades for Aruba InnstantOS that address these security vulnerabilities." } ], "problemTypes": [ { "descriptions": [ { "description": "Buffer Overflow Vulnerability", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-11-08T00:00:00", "orgId": "eb103674-0d28-4225-80f8-39fb86215de0", "shortName": "hpe" }, "references": [ { "url": "https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2022-014.txt" }, { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-506569.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0", "assignerShortName": "hpe", "cveId": "CVE-2022-37889", "datePublished": "2022-10-07T00:00:00", "dateReserved": "2022-08-08T00:00:00", "dateUpdated": "2024-08-03T10:37:41.984Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2022-37889\",\"sourceIdentifier\":\"security-alert@hpe.com\",\"published\":\"2022-10-07T18:15:21.307\",\"lastModified\":\"2024-11-21T07:15:19.040\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"There are buffer overflow vulnerabilities in multiple underlying services that could lead to unauthenticated remote code execution by sending specially crafted packets destined to the PAPI (Aruba Networks AP management protocol) UDP port (8211). Successful exploitation of these vulnerabilities results in the ability to execute arbitrary code as a privileged user on the underlying operating system of Aruba InstantOS 6.4.x: 6.4.4.8-4.2.4.20 and below; Aruba InstantOS 6.5.x: 6.5.4.23 and below; Aruba InstantOS 8.6.x: 8.6.0.18 and below; Aruba InstantOS 8.7.x: 8.7.1.9 and below; Aruba InstantOS 8.10.x: 8.10.0.1 and below; ArubaOS 10.3.x: 10.3.1.0 and below; Aruba has released upgrades for Aruba InnstantOS that address these security vulnerabilities.\"},{\"lang\":\"es\",\"value\":\"Se presentan vulnerabilidades de desbordamiento de b\u00fafer en m\u00faltiples servicios subyacentes que podr\u00edan conllevar a una ejecuci\u00f3n de c\u00f3digo remota no autenticado mediante el env\u00edo de paquetes especialmente dise\u00f1ados destinados al puerto UDP de PAPI (protocolo de administraci\u00f3n de AP de Aruba Networks) (8211). Una explotaci\u00f3n con \u00e9xito de estas vulnerabilidades resulta en la capacidad de ejecutar c\u00f3digo arbitrario como un usuario privilegiado en el sistema operativo subyacente de Aruba InstantOS versiones 6.4.x: 6.4.4.8-4.2.4.20 y anteriores; Aruba InstantOS 6.5.x: 6.5.4.23 y anteriores; Aruba InstantOS 8. 6.x: 8.6.0.18 y anteriores; Aruba InstantOS 8.7.x: 8.7.1.9 y anteriores; Aruba InstantOS 8.10.x: 8.10.0.1 y anteriores; ArubaOS 10.3.x: 10.3.1.0 y anteriores; Aruba ha publicado actualizaciones para Aruba InstantOS que abordan estas vulnerabilidades de seguridad\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-120\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:arubanetworks:arubaos:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"10.3.0.0\",\"versionEndExcluding\":\"10.3.1.1\",\"matchCriteriaId\":\"F1B6376E-424F-4DBF-B00D-69C52E4B3E46\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:arubanetworks:instant:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"6.4.0.0\",\"versionEndExcluding\":\"6.4.4.8-4.2.4.21\",\"matchCriteriaId\":\"D27F5A7C-442F-45A6-A149-2037042A1629\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:arubanetworks:instant:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"6.5.0.0\",\"versionEndExcluding\":\"6.5.4.24\",\"matchCriteriaId\":\"6A33DE52-E905-4EBD-BA56-1DC67B7DD9FD\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:arubanetworks:instant:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"8.6.0.0\",\"versionEndExcluding\":\"8.6.0.19\",\"matchCriteriaId\":\"081502CC-38D4-46F9-85D0-3D1F701D5EE4\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:arubanetworks:instant:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"8.7.0.0\",\"versionEndExcluding\":\"8.7.1.10\",\"matchCriteriaId\":\"BEA3846D-54C5-4B92-86B6-6AC482C2B357\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:arubanetworks:instant:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"8.10.0.0\",\"versionEndExcluding\":\"8.10.0.2\",\"matchCriteriaId\":\"B32D91E1-3034-4E05-8FBA-98EF4562F3FE\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_w1750d_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"065280B2-6EC1-4721-B3D7-EDE44ED4F5BD\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_w1750d:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FBC30055-239F-4BB1-B2D1-E5E35F0D8911\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-506569.pdf\",\"source\":\"security-alert@hpe.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2022-014.txt\",\"source\":\"security-alert@hpe.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-506569.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2022-014.txt\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
icsa-22-314-10
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens", "summary": "reporting these vulnerabilities to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could allow an attacker to inject commands or exploit buffer overflow vulnerabilities, which could lead to denial of service, unauthenticated remote code execution. or stored XSS.", "title": "Risk evaluation" }, { "category": "other", "text": "Multiple Sectors", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability these vulnerabilities. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage at cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also recommends users take the following measures to protect themselves from social engineering attacks:", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities. These vulnerabilities are exploitable remotely. These vulnerabilities have a low attack complexity.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "external", "summary": "SSA-506569: Multiple Vulnerabilities in SCALANCE W1750D - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-506569.json" }, { "category": "self", "summary": "ICS Advisory ICSA-22-314-10 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-314-10.json" }, { "category": "self", "summary": "ICS Advisory ICSA-22-314-10 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-314-10" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-314-10" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "SSA-506569: Multiple Vulnerabilities in SCALANCE W1750D - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-506569.pdf" }, { "category": "external", "summary": "SSA-506569: Multiple Vulnerabilities in SCALANCE W1750D - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-506569.txt" } ], "title": "Siemens SCALANCE W1750D", "tracking": { "current_release_date": "2022-11-10T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-22-314-10", "initial_release_date": "2022-11-10T00:00:00.000000Z", "revision_history": [ { "date": "2022-11-10T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c V8.7.1.11", "product": { "name": "SCALANCE W1750D (JP) (6GK5750-2HX01-1AD0)", "product_id": "CSAFPID-0001", "product_identification_helper": { "model_numbers": [ "6GK5750-2HX01-1AD0" ] } } } ], "category": "product_name", "name": "SCALANCE W1750D (JP) (6GK5750-2HX01-1AD0)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V8.7.1.11", "product": { "name": "SCALANCE W1750D (ROW) (6GK5750-2HX01-1AA0)", "product_id": "CSAFPID-0002", "product_identification_helper": { "model_numbers": [ "6GK5750-2HX01-1AA0" ] } } } ], "category": "product_name", "name": "SCALANCE W1750D (ROW) (6GK5750-2HX01-1AA0)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V8.7.1.11", "product": { "name": "SCALANCE W1750D (USA) (6GK5750-2HX01-1AB0)", "product_id": "CSAFPID-0003", "product_identification_helper": { "model_numbers": [ "6GK5750-2HX01-1AB0" ] } } } ], "category": "product_name", "name": "SCALANCE W1750D (USA) (6GK5750-2HX01-1AB0)" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2002-20001", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "summary", "text": "The Diffie-Hellman Key Agreement Protocol allows remote attackers (from the client side) to send arbitrary numbers that are actually not public keys, and trigger expensive server-side DHE modular-exponentiation calculations, aka a D(HE)ater attack. The client needs very little CPU resources and network bandwidth. The attack may be more disruptive in cases where a client can require a server to select its largest supported key size. The basic attack scenario is that the client must claim that it can only communicate with DHE, and the server must be configured to allow DHE. (ATLWL-266)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "nvd.nist.gov", "url": "https://nvd.nist.gov/vuln/detail/CVE-2002-20001" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V8.7.1.11 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2002-20001" }, { "cve": "CVE-2022-37885", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "A buffer overflow vulnerability in an underlying service could lead to unauthenticated remote code execution by sending specially crafted packets destined to the PAPI UDP port (8211). (ATLWL-253)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "nvd.nist.gov", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-37885" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "CVE-2022-37885, CVE-2022-37886, CVE-2022-37887, CVE-2022-37888, CVE-2022-37889: Enable CPSec via the cluster-security command", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V8.7.1.11 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2022-37885" }, { "cve": "CVE-2022-37886", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "A buffer overflow vulnerability in an underlying service could lead to unauthenticated remote code execution by sending specially crafted packets destined to the PAPI UDP port (8211). (ATLWL-254)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "nvd.nist.gov", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-37886" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "CVE-2022-37885, CVE-2022-37886, CVE-2022-37887, CVE-2022-37888, CVE-2022-37889: Enable CPSec via the cluster-security command", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V8.7.1.11 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2022-37886" }, { "cve": "CVE-2022-37887", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "A buffer overflow vulnerability in an underlying service could lead to unauthenticated remote code execution by sending specially crafted packets destined to the PAPI UDP port (8211). (ATLWL-299)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "nvd.nist.gov", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-37887" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "CVE-2022-37885, CVE-2022-37886, CVE-2022-37887, CVE-2022-37888, CVE-2022-37889: Enable CPSec via the cluster-security command", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V8.7.1.11 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2022-37887" }, { "cve": "CVE-2022-37888", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "A buffer overflow vulnerability in an underlying service could lead to unauthenticated remote code execution by sending specially crafted packets destined to the PAPI UDP port (8211). (ATLWL-300)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "nvd.nist.gov", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-37888" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "CVE-2022-37885, CVE-2022-37886, CVE-2022-37887, CVE-2022-37888, CVE-2022-37889: Enable CPSec via the cluster-security command", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V8.7.1.11 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2022-37888" }, { "cve": "CVE-2022-37889", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "A buffer overflow vulnerability in an underlying service could lead to unauthenticated remote code execution by sending specially crafted packets destined to the PAPI UDP port (8211). (ATLWL-302)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "nvd.nist.gov", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-37889" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "CVE-2022-37885, CVE-2022-37886, CVE-2022-37887, CVE-2022-37888, CVE-2022-37889: Enable CPSec via the cluster-security command", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V8.7.1.11 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2022-37889" }, { "cve": "CVE-2022-37890", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "An unauthenticated buffer overflow vulnerability exists within the web management interface. Successful exploitation results in the execution of arbitrary commands on the underlying operating system. (ATLWL-102)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "nvd.nist.gov", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-37890" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "CVE-2022-37890, CVE-2022-37891, CVE-2022-37892, CVE-2022-37895, CVE-2022-37896: Restrict the web-based management interface to a dedicated layer 2 segment/VLAN and/or control the interface by firewall policies at layer 3 and above", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V8.7.1.11 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2022-37890" }, { "cve": "CVE-2022-37891", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "An unauthenticated buffer overflow vulnerability exists within the web management interface. Successful exploitation results in the execution of arbitrary commands on the underlying operating system. (ATLWL-268)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "nvd.nist.gov", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-37891" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "CVE-2022-37890, CVE-2022-37891, CVE-2022-37892, CVE-2022-37895, CVE-2022-37896: Restrict the web-based management interface to a dedicated layer 2 segment/VLAN and/or control the interface by firewall policies at layer 3 and above", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V8.7.1.11 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2022-37891" }, { "cve": "CVE-2022-37892", "cwe": { "id": "CWE-79", "name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)" }, "notes": [ { "category": "summary", "text": "A vulnerability in the web management interface could allow an unauthenticated remote attacker to conduct a stored cross-site scripting (XSS) attack against a user of the interface. A successful exploit could allow an attacker to execute arbitrary script code in a victim\u2019s browser in the context of the affected interface. (ATLWL-168)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "nvd.nist.gov", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-37892" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N" } ], "remediations": [ { "category": "mitigation", "details": "CVE-2022-37890, CVE-2022-37891, CVE-2022-37892, CVE-2022-37895, CVE-2022-37896: Restrict the web-based management interface to a dedicated layer 2 segment/VLAN and/or control the interface by firewall policies at layer 3 and above", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V8.7.1.11 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2022-37892" }, { "cve": "CVE-2022-37893", "cwe": { "id": "CWE-77", "name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)" }, "notes": [ { "category": "summary", "text": "An authenticated command injection vulnerability exists in the command line interface. Successful exploitation of this vulnerability results in the ability to execute arbitrary commands as a privileged user on the underlying operating system. (ATLWL-97)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "nvd.nist.gov", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-37893" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "CVE-2022-37893: Restrict the command line interface to a dedicated layer 2 segment/VLAN and/or control the interface by firewall policies at layer 3 and above", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V8.7.1.11 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2022-37893" }, { "cve": "CVE-2022-37894", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "An unauthenticated denial of service (DoS) vulnerability exists in the handling of certain SSID strings. Successful exploitation of this vulnerability results in the ability to interrupt the normal operation of the affected Access Point. (ATLWL-242)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "nvd.nist.gov", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-37894" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V8.7.1.11 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2022-37894" }, { "cve": "CVE-2022-37895", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "An authenticated denial of service (DoS) vulnerability exists in the web management interface. Successful exploitation of this vulnerability results in the ability to interrupt the normal operation of the affected Access Point. (ATLWL-248)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "nvd.nist.gov", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-37895" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "mitigation", "details": "CVE-2022-37890, CVE-2022-37891, CVE-2022-37892, CVE-2022-37895, CVE-2022-37896: Restrict the web-based management interface to a dedicated layer 2 segment/VLAN and/or control the interface by firewall policies at layer 3 and above", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V8.7.1.11 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2022-37895" }, { "cve": "CVE-2022-37896", "cwe": { "id": "CWE-79", "name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)" }, "notes": [ { "category": "summary", "text": "A vulnerability in the web management interface could allow a remote attacker to conduct a reflected cross-site scripting (XSS) attack against a user of the interface. A successful exploit could allow an attacker to execute arbitrary script code in a victim\u2019s browser in the context of the affected interface. (ATLWL-234)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "nvd.nist.gov", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-37896" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N" } ], "remediations": [ { "category": "mitigation", "details": "CVE-2022-37890, CVE-2022-37891, CVE-2022-37892, CVE-2022-37895, CVE-2022-37896: Restrict the web-based management interface to a dedicated layer 2 segment/VLAN and/or control the interface by firewall policies at layer 3 and above", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V8.7.1.11 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.1, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2022-37896" } ] }
ICSA-22-314-10
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens", "summary": "reporting these vulnerabilities to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could allow an attacker to inject commands or exploit buffer overflow vulnerabilities, which could lead to denial of service, unauthenticated remote code execution. or stored XSS.", "title": "Risk evaluation" }, { "category": "other", "text": "Multiple Sectors", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability these vulnerabilities. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage at cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also recommends users take the following measures to protect themselves from social engineering attacks:", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities. These vulnerabilities are exploitable remotely. These vulnerabilities have a low attack complexity.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "external", "summary": "SSA-506569: Multiple Vulnerabilities in SCALANCE W1750D - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-506569.json" }, { "category": "self", "summary": "ICS Advisory ICSA-22-314-10 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-314-10.json" }, { "category": "self", "summary": "ICS Advisory ICSA-22-314-10 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-314-10" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-314-10" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "SSA-506569: Multiple Vulnerabilities in SCALANCE W1750D - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-506569.pdf" }, { "category": "external", "summary": "SSA-506569: Multiple Vulnerabilities in SCALANCE W1750D - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-506569.txt" } ], "title": "Siemens SCALANCE W1750D", "tracking": { "current_release_date": "2022-11-10T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-22-314-10", "initial_release_date": "2022-11-10T00:00:00.000000Z", "revision_history": [ { "date": "2022-11-10T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c V8.7.1.11", "product": { "name": "SCALANCE W1750D (JP) (6GK5750-2HX01-1AD0)", "product_id": "CSAFPID-0001", "product_identification_helper": { "model_numbers": [ "6GK5750-2HX01-1AD0" ] } } } ], "category": "product_name", "name": "SCALANCE W1750D (JP) (6GK5750-2HX01-1AD0)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V8.7.1.11", "product": { "name": "SCALANCE W1750D (ROW) (6GK5750-2HX01-1AA0)", "product_id": "CSAFPID-0002", "product_identification_helper": { "model_numbers": [ "6GK5750-2HX01-1AA0" ] } } } ], "category": "product_name", "name": "SCALANCE W1750D (ROW) (6GK5750-2HX01-1AA0)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V8.7.1.11", "product": { "name": "SCALANCE W1750D (USA) (6GK5750-2HX01-1AB0)", "product_id": "CSAFPID-0003", "product_identification_helper": { "model_numbers": [ "6GK5750-2HX01-1AB0" ] } } } ], "category": "product_name", "name": "SCALANCE W1750D (USA) (6GK5750-2HX01-1AB0)" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2002-20001", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "summary", "text": "The Diffie-Hellman Key Agreement Protocol allows remote attackers (from the client side) to send arbitrary numbers that are actually not public keys, and trigger expensive server-side DHE modular-exponentiation calculations, aka a D(HE)ater attack. The client needs very little CPU resources and network bandwidth. The attack may be more disruptive in cases where a client can require a server to select its largest supported key size. The basic attack scenario is that the client must claim that it can only communicate with DHE, and the server must be configured to allow DHE. (ATLWL-266)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "nvd.nist.gov", "url": "https://nvd.nist.gov/vuln/detail/CVE-2002-20001" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V8.7.1.11 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2002-20001" }, { "cve": "CVE-2022-37885", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "A buffer overflow vulnerability in an underlying service could lead to unauthenticated remote code execution by sending specially crafted packets destined to the PAPI UDP port (8211). (ATLWL-253)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "nvd.nist.gov", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-37885" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "CVE-2022-37885, CVE-2022-37886, CVE-2022-37887, CVE-2022-37888, CVE-2022-37889: Enable CPSec via the cluster-security command", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V8.7.1.11 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2022-37885" }, { "cve": "CVE-2022-37886", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "A buffer overflow vulnerability in an underlying service could lead to unauthenticated remote code execution by sending specially crafted packets destined to the PAPI UDP port (8211). (ATLWL-254)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "nvd.nist.gov", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-37886" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "CVE-2022-37885, CVE-2022-37886, CVE-2022-37887, CVE-2022-37888, CVE-2022-37889: Enable CPSec via the cluster-security command", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V8.7.1.11 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2022-37886" }, { "cve": "CVE-2022-37887", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "A buffer overflow vulnerability in an underlying service could lead to unauthenticated remote code execution by sending specially crafted packets destined to the PAPI UDP port (8211). (ATLWL-299)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "nvd.nist.gov", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-37887" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "CVE-2022-37885, CVE-2022-37886, CVE-2022-37887, CVE-2022-37888, CVE-2022-37889: Enable CPSec via the cluster-security command", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V8.7.1.11 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2022-37887" }, { "cve": "CVE-2022-37888", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "A buffer overflow vulnerability in an underlying service could lead to unauthenticated remote code execution by sending specially crafted packets destined to the PAPI UDP port (8211). (ATLWL-300)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "nvd.nist.gov", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-37888" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "CVE-2022-37885, CVE-2022-37886, CVE-2022-37887, CVE-2022-37888, CVE-2022-37889: Enable CPSec via the cluster-security command", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V8.7.1.11 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2022-37888" }, { "cve": "CVE-2022-37889", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "A buffer overflow vulnerability in an underlying service could lead to unauthenticated remote code execution by sending specially crafted packets destined to the PAPI UDP port (8211). (ATLWL-302)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "nvd.nist.gov", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-37889" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "CVE-2022-37885, CVE-2022-37886, CVE-2022-37887, CVE-2022-37888, CVE-2022-37889: Enable CPSec via the cluster-security command", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V8.7.1.11 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2022-37889" }, { "cve": "CVE-2022-37890", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "An unauthenticated buffer overflow vulnerability exists within the web management interface. Successful exploitation results in the execution of arbitrary commands on the underlying operating system. (ATLWL-102)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "nvd.nist.gov", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-37890" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "CVE-2022-37890, CVE-2022-37891, CVE-2022-37892, CVE-2022-37895, CVE-2022-37896: Restrict the web-based management interface to a dedicated layer 2 segment/VLAN and/or control the interface by firewall policies at layer 3 and above", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V8.7.1.11 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2022-37890" }, { "cve": "CVE-2022-37891", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "An unauthenticated buffer overflow vulnerability exists within the web management interface. Successful exploitation results in the execution of arbitrary commands on the underlying operating system. (ATLWL-268)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "nvd.nist.gov", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-37891" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "CVE-2022-37890, CVE-2022-37891, CVE-2022-37892, CVE-2022-37895, CVE-2022-37896: Restrict the web-based management interface to a dedicated layer 2 segment/VLAN and/or control the interface by firewall policies at layer 3 and above", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V8.7.1.11 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2022-37891" }, { "cve": "CVE-2022-37892", "cwe": { "id": "CWE-79", "name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)" }, "notes": [ { "category": "summary", "text": "A vulnerability in the web management interface could allow an unauthenticated remote attacker to conduct a stored cross-site scripting (XSS) attack against a user of the interface. A successful exploit could allow an attacker to execute arbitrary script code in a victim\u2019s browser in the context of the affected interface. (ATLWL-168)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "nvd.nist.gov", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-37892" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N" } ], "remediations": [ { "category": "mitigation", "details": "CVE-2022-37890, CVE-2022-37891, CVE-2022-37892, CVE-2022-37895, CVE-2022-37896: Restrict the web-based management interface to a dedicated layer 2 segment/VLAN and/or control the interface by firewall policies at layer 3 and above", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V8.7.1.11 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 5.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2022-37892" }, { "cve": "CVE-2022-37893", "cwe": { "id": "CWE-77", "name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)" }, "notes": [ { "category": "summary", "text": "An authenticated command injection vulnerability exists in the command line interface. Successful exploitation of this vulnerability results in the ability to execute arbitrary commands as a privileged user on the underlying operating system. (ATLWL-97)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "nvd.nist.gov", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-37893" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "CVE-2022-37893: Restrict the command line interface to a dedicated layer 2 segment/VLAN and/or control the interface by firewall policies at layer 3 and above", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V8.7.1.11 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2022-37893" }, { "cve": "CVE-2022-37894", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "An unauthenticated denial of service (DoS) vulnerability exists in the handling of certain SSID strings. Successful exploitation of this vulnerability results in the ability to interrupt the normal operation of the affected Access Point. (ATLWL-242)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "nvd.nist.gov", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-37894" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V8.7.1.11 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2022-37894" }, { "cve": "CVE-2022-37895", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "summary", "text": "An authenticated denial of service (DoS) vulnerability exists in the web management interface. Successful exploitation of this vulnerability results in the ability to interrupt the normal operation of the affected Access Point. (ATLWL-248)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "nvd.nist.gov", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-37895" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "mitigation", "details": "CVE-2022-37890, CVE-2022-37891, CVE-2022-37892, CVE-2022-37895, CVE-2022-37896: Restrict the web-based management interface to a dedicated layer 2 segment/VLAN and/or control the interface by firewall policies at layer 3 and above", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V8.7.1.11 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2022-37895" }, { "cve": "CVE-2022-37896", "cwe": { "id": "CWE-79", "name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)" }, "notes": [ { "category": "summary", "text": "A vulnerability in the web management interface could allow a remote attacker to conduct a reflected cross-site scripting (XSS) attack against a user of the interface. A successful exploit could allow an attacker to execute arbitrary script code in a victim\u2019s browser in the context of the affected interface. (ATLWL-234)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "nvd.nist.gov", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-37896" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.1#CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N" } ], "remediations": [ { "category": "mitigation", "details": "CVE-2022-37890, CVE-2022-37891, CVE-2022-37892, CVE-2022-37895, CVE-2022-37896: Restrict the web-based management interface to a dedicated layer 2 segment/VLAN and/or control the interface by firewall policies at layer 3 and above", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V8.7.1.11 or later version", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109816886/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.1, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N/E:P/RL:T/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2022-37896" } ] }
ghsa-c553-7wj6-jj4q
Vulnerability from github
There are buffer overflow vulnerabilities in multiple underlying services that could lead to unauthenticated remote code execution by sending specially crafted packets destined to the PAPI (Aruba Networks AP management protocol) UDP port (8211). Successful exploitation of these vulnerabilities results in the ability to execute arbitrary code as a privileged user on the underlying operating system of Aruba InstantOS 6.4.x: 6.4.4.8-4.2.4.20 and below; Aruba InstantOS 6.5.x: 6.5.4.23 and below; Aruba InstantOS 8.6.x: 8.6.0.18 and below; Aruba InstantOS 8.7.x: 8.7.1.9 and below; Aruba InstantOS 8.10.x: 8.10.0.1 and below; ArubaOS 10.3.x: 10.3.1.0 and below; Aruba has released upgrades for Aruba InnstantOS that address these security vulnerabilities.
{ "affected": [], "aliases": [ "CVE-2022-37889" ], "database_specific": { "cwe_ids": [ "CWE-120" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2022-10-07T18:15:00Z", "severity": "CRITICAL" }, "details": "There are buffer overflow vulnerabilities in multiple underlying services that could lead to unauthenticated remote code execution by sending specially crafted packets destined to the PAPI (Aruba Networks AP management protocol) UDP port (8211). Successful exploitation of these vulnerabilities results in the ability to execute arbitrary code as a privileged user on the underlying operating system of Aruba InstantOS 6.4.x: 6.4.4.8-4.2.4.20 and below; Aruba InstantOS 6.5.x: 6.5.4.23 and below; Aruba InstantOS 8.6.x: 8.6.0.18 and below; Aruba InstantOS 8.7.x: 8.7.1.9 and below; Aruba InstantOS 8.10.x: 8.10.0.1 and below; ArubaOS 10.3.x: 10.3.1.0 and below; Aruba has released upgrades for Aruba InnstantOS that address these security vulnerabilities.", "id": "GHSA-c553-7wj6-jj4q", "modified": "2022-10-11T19:00:27Z", "published": "2022-10-07T18:15:41Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2022-37889" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-506569.pdf" }, { "type": "WEB", "url": "https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2022-014.txt" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "type": "CVSS_V3" } ] }
gsd-2022-37889
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2022-37889", "description": "There are buffer overflow vulnerabilities in multiple underlying services that could lead to unauthenticated remote code execution by sending specially crafted packets destined to the PAPI (Aruba Networks AP management protocol) UDP port (8211). Successful exploitation of these vulnerabilities results in the ability to execute arbitrary code as a privileged user on the underlying operating system of Aruba InstantOS 6.4.x: 6.4.4.8-4.2.4.20 and below; Aruba InstantOS 6.5.x: 6.5.4.23 and below; Aruba InstantOS 8.6.x: 8.6.0.18 and below; Aruba InstantOS 8.7.x: 8.7.1.9 and below; Aruba InstantOS 8.10.x: 8.10.0.1 and below; ArubaOS 10.3.x: 10.3.1.0 and below; Aruba has released upgrades for Aruba InnstantOS that address these security vulnerabilities.", "id": "GSD-2022-37889" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2022-37889" ], "details": "There are buffer overflow vulnerabilities in multiple underlying services that could lead to unauthenticated remote code execution by sending specially crafted packets destined to the PAPI (Aruba Networks AP management protocol) UDP port (8211). Successful exploitation of these vulnerabilities results in the ability to execute arbitrary code as a privileged user on the underlying operating system of Aruba InstantOS 6.4.x: 6.4.4.8-4.2.4.20 and below; Aruba InstantOS 6.5.x: 6.5.4.23 and below; Aruba InstantOS 8.6.x: 8.6.0.18 and below; Aruba InstantOS 8.7.x: 8.7.1.9 and below; Aruba InstantOS 8.10.x: 8.10.0.1 and below; ArubaOS 10.3.x: 10.3.1.0 and below; Aruba has released upgrades for Aruba InnstantOS that address these security vulnerabilities.", "id": "GSD-2022-37889", "modified": "2023-12-13T01:19:13.235341Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "security-alert@hpe.com", "ID": "CVE-2022-37889", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Aruba Access Points: 100 Series; 103 Series; 110 Series; 120 Series; 130 Series; 200 Series; 207 Series; 210 Series; 220 Series; 260 Series; 300 Series; 303 Series; 310 Series; 318 Series Hardened Access Points; 320 Series; 330 Series; 340 Series; 370 Series; 500 Series; 510 Series; 530 Series; 550 Series; 630 Series; 650 Series;", "version": { "version_data": [ { "version_value": "Aruba InstantOS 6.4.x: 6.4.4.8-4.2.4.20 and below" }, { "version_value": "Aruba InstantOS 6.5.x: 6.5.4.23 and below" }, { "version_value": "Aruba InstantOS 8.6.x: 8.6.0.18 and below" }, { "version_value": "Aruba InstantOS 8.7.x: 8.7.1.9 and below" }, { "version_value": "Aruba InstantOS 8.10.x: 8.10.0.1 and below" }, { "version_value": "ArubaOS 10.3.x: 10.3.1.0 and below" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "There are buffer overflow vulnerabilities in multiple underlying services that could lead to unauthenticated remote code execution by sending specially crafted packets destined to the PAPI (Aruba Networks AP management protocol) UDP port (8211). Successful exploitation of these vulnerabilities results in the ability to execute arbitrary code as a privileged user on the underlying operating system of Aruba InstantOS 6.4.x: 6.4.4.8-4.2.4.20 and below; Aruba InstantOS 6.5.x: 6.5.4.23 and below; Aruba InstantOS 8.6.x: 8.6.0.18 and below; Aruba InstantOS 8.7.x: 8.7.1.9 and below; Aruba InstantOS 8.10.x: 8.10.0.1 and below; ArubaOS 10.3.x: 10.3.1.0 and below; Aruba has released upgrades for Aruba InnstantOS that address these security vulnerabilities." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Buffer Overflow Vulnerability" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2022-014.txt", "refsource": "MISC", "url": "https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2022-014.txt" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-506569.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-506569.pdf" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:arubanetworks:instant:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.10.0.2", "versionStartIncluding": "8.10.0.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:arubanetworks:instant:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.7.1.10", "versionStartIncluding": "8.7.0.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:arubanetworks:instant:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "8.6.0.19", "versionStartIncluding": "8.6.0.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:arubanetworks:instant:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "6.5.4.24", "versionStartIncluding": "6.5.0.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:arubanetworks:instant:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "6.4.4.8-4.2.4.21", "versionStartIncluding": "6.4.0.0", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:arubanetworks:arubaos:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "10.3.1.1", "versionStartIncluding": "10.3.0.0", "vulnerable": true } ], "operator": "OR" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:scalance_w1750d_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:scalance_w1750d:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "security-alert@hpe.com", "ID": "CVE-2022-37889" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "There are buffer overflow vulnerabilities in multiple underlying services that could lead to unauthenticated remote code execution by sending specially crafted packets destined to the PAPI (Aruba Networks AP management protocol) UDP port (8211). Successful exploitation of these vulnerabilities results in the ability to execute arbitrary code as a privileged user on the underlying operating system of Aruba InstantOS 6.4.x: 6.4.4.8-4.2.4.20 and below; Aruba InstantOS 6.5.x: 6.5.4.23 and below; Aruba InstantOS 8.6.x: 8.6.0.18 and below; Aruba InstantOS 8.7.x: 8.7.1.9 and below; Aruba InstantOS 8.10.x: 8.10.0.1 and below; ArubaOS 10.3.x: 10.3.1.0 and below; Aruba has released upgrades for Aruba InnstantOS that address these security vulnerabilities." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-120" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2022-014.txt", "refsource": "MISC", "tags": [ "Vendor Advisory" ], "url": "https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2022-014.txt" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-506569.pdf", "refsource": "CONFIRM", "tags": [ "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-506569.pdf" } ] } }, "impact": { "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9 } }, "lastModifiedDate": "2022-11-09T03:59Z", "publishedDate": "2022-10-07T18:15Z" } } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.