A malicious crafted dwf or .pct file when consumed through DesignReview.exe application could lead to memory corruption vulnerability by read access violation. This vulnerability in conjunction with other vulnerabilities could lead to code execution in the context of the current process.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T13:19:05.485Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.autodesk.com/trust/security-advisories/adsk-sa-2022-0004"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Autodesk Design Review",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "2018,\u00a02017,\u00a02013, 2012, 2011"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A malicious crafted dwf or .pct file when consumed through DesignReview.exe application could lead to memory corruption vulnerability by read access violation. This vulnerability in conjunction with other vulnerabilities could lead to code execution in the context of the current process."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Memory corruption vulnerability",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-10-21T00:00:00",
        "orgId": "7e40ea87-bc65-4944-9723-dd79dd760601",
        "shortName": "autodesk"
      },
      "references": [
        {
          "url": "https://www.autodesk.com/trust/security-advisories/adsk-sa-2022-0004"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7e40ea87-bc65-4944-9723-dd79dd760601",
    "assignerShortName": "autodesk",
    "cveId": "CVE-2022-42944",
    "datePublished": "2022-10-21T00:00:00",
    "dateReserved": "2022-10-14T00:00:00",
    "dateUpdated": "2024-08-03T13:19:05.485Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2022-42944\",\"sourceIdentifier\":\"psirt@autodesk.com\",\"published\":\"2022-10-21T16:15:12.077\",\"lastModified\":\"2024-11-21T07:25:38.937\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A malicious crafted dwf or .pct file when consumed through DesignReview.exe application could lead to memory corruption vulnerability by read access violation. This vulnerability in conjunction with other vulnerabilities could lead to code execution in the context of the current process.\"},{\"lang\":\"es\",\"value\":\"Un archivo dwf o .pct malicioso dise\u00f1ado cuando es consumido mediante la aplicaci\u00f3n DesignReview.exe podr\u00eda conllevar a una vulnerabilidad de corrupci\u00f3n de memoria por violaci\u00f3n de acceso de lectura. Esta vulnerabilidad, junto con otras, podr\u00eda conllevar a una ejecuci\u00f3n de c\u00f3digo en el contexto del proceso actual\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad:2019:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"411DC826-735A-4BEB-84BE-9250F97F612E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad:2020:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E30E2562-D38E-4764-874E-5B2FCF5639E5\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad:2021:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"88B2C295-D091-4C1D-8285-4309967707BC\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad:2022:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EACE09F2-A323-4E4B-9A35-4EBAE3864E6C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad:2022:*:*:*:*:macos:*:*\",\"matchCriteriaId\":\"68FC54D1-B4FC-404E-9742-72F8340FE3C7\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad:2023:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2241C287-9396-4AD8-B93C-3596394AB2D3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_advance_steel:2019:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9B1CAD53-7C63-4E5D-BD2E-364A7A87AA1E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_advance_steel:2020:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"127F5A79-8E66-4ABD-8D88-8891C6D670D5\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_advance_steel:2021:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"37D8982C-E506-4988-AA97-BDF1B1C3D71A\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_advance_steel:2022:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"002AC200-6AE2-4817-91D3-957DA3AC9787\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_advance_steel:2023:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E881C720-E487-463E-A364-A1F9EC3C1D24\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_architecture:2019:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9275E76C-2A79-462A-A9D3-D0B6BBCDD0CC\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_architecture:2020:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B7DFA12E-48C5-47B9-BD9F-1AFACBF4E1EA\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_architecture:2021:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"535A5D39-1C82-4301-9E5B-C9E0D75F38B9\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_architecture:2022:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"316615EC-BC9F-4B6A-8163-EBECC480EFDE\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_architecture:2023:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"546AFB2D-F78A-40C2-AC55-7D07EF0BDC7A\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_civil_3d:2019:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AB3A878B-2142-404F-BCF4-BB508674C6C4\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_civil_3d:2020:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"64F2EC88-168D-4DD1-9ADA-3F9FA60D6E35\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_civil_3d:2021:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5D73C803-7567-4C1D-B62A-C3C52369022D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_civil_3d:2022:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C5F77B03-3221-4564-B4FF-7BF7EEC1C5B6\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_civil_3d:2023:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C6E001C0-0D7B-44ED-BBE8-E6635C45F988\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_electrical:2019:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A10DE5AF-1718-4899-9238-CFFDC72D05B7\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_electrical:2020:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E388264D-D2D4-4BE4-9097-8F547D73ABE5\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_electrical:2021:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"16611BAA-C200-4C8B-823F-1AB95F5E1317\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_electrical:2022:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E2DC5114-48D2-4D85-8E80-B4BCB0FD78F5\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_electrical:2023:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A2949D87-C1FA-43C3-8F1F-08ED7A64F302\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_lt:2019:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"03682B7E-1CF1-4456-A51F-A6ADFC177935\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_lt:2020:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"371C5F60-4959-40C7-93E1-A01510A95115\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_lt:2021:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D83FB4C7-B374-4907-8E2B-EEE61C8339E7\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_lt:2022:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"601676EC-2EB4-45D0-B1AE-0980CBD68770\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_lt:2022:*:*:*:*:macos:*:*\",\"matchCriteriaId\":\"4A2EF334-E4E2-40DA-BD51-B74EE1E0ACCF\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_lt:2023:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"99924DDE-3D49-4D37-A361-69B28E7B94A3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_map_3d:2019:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"04E05510-B21B-4DDD-88D7-CEB8963E1AFB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_map_3d:2020:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D4CD010A-FDBC-40F9-95AC-0CD8388B85D1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_map_3d:2021:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FC99E0F3-AA11-4390-A7C0-5BBFCDA94E3F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_map_3d:2022:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"33AA60CF-611C-45FC-92F8-7517D87B1645\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_map_3d:2023:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"15A36E1F-964C-4DF2-91D1-D37ECEFC1C86\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_mechanical:2019:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"19255CEC-6161-4D44-B87E-52E86DF4FBA7\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_mechanical:2020:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7147F378-DFB0-48A8-8B05-8777E1CC7F90\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_mechanical:2021:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3B5C858C-4A01-4916-BE3E-B9056D67CF5F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_mechanical:2022:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7EB83A4A-D4C2-4509-BD49-15B9BBC7BF97\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_mechanical:2023:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DCF7910A-432F-419E-96E0-25D638A6F298\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_mep:2019:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3F608B1C-BA96-4EA8-A540-83870262CBC1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_mep:2020:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7CFAAD19-6248-42CB-B177-EC2E5141A953\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_mep:2021:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1C52D90B-578B-4281-BF0E-B7CDA425ED05\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_mep:2022:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4C8AD4F3-AA82-49F5-A18A-85127FDB8B95\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_mep:2023:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DF8D9BA5-A043-42DB-A524-6728D3BF2B90\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_plant_3d:2019:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4E536B0D-4C95-4589-981A-2F8A6C4B44DC\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_plant_3d:2020:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3FBDD3AC-FA00-462F-AA13-5A75B5D50689\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_plant_3d:2021:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"73E2E9E8-2269-4729-8D8F-3C26974F5FD2\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_plant_3d:2022:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"452A1A75-C59A-43AB-9C43-BA49EB95C39C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:autocad_plant_3d:2023:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"07CB7F37-E6D4-40F3-85BA-EC060E923505\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:autodesk:design_review:2018:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"213232B9-A40B-436D-A66A-B65C49D59BE6\"}]}]}],\"references\":[{\"url\":\"https://www.autodesk.com/trust/security-advisories/adsk-sa-2022-0004\",\"source\":\"psirt@autodesk.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://www.autodesk.com/trust/security-advisories/adsk-sa-2022-0004\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.