CVE-2023-0863 (GCVE-0-2023-0863)
Vulnerability from cvelistv5 – Published: 2023-05-17 07:10 – Updated: 2025-01-22 16:50
VLAI?
Title
Authentication to access the AC wallbox via its Bluetooth Low Energy (BLE) channel can be bypassed,
Summary
Improper Authentication vulnerability in ABB Terra AC wallbox (UL40/80A), ABB Terra AC wallbox (UL32A), ABB Terra AC wallbox (CE) (Terra AC MID), ABB Terra AC wallbox (CE) Terra AC Juno CE, ABB Terra AC wallbox (CE) Terra AC PTB, ABB Terra AC wallbox (CE) Symbiosis, ABB Terra AC wallbox (JP).This issue affects Terra AC wallbox (UL40/80A): from 1.0;0 through 1.5.5; Terra AC wallbox (UL32A) : from 1.0;0 through 1.6.5; Terra AC wallbox (CE) (Terra AC MID): from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC Juno CE: from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC PTB : from 1.0;0 through 1.5.25; Terra AC wallbox (CE) Symbiosis: from 1.0;0 through 1.2.7; Terra AC wallbox (JP): from 1.0;0 through 1.6.5.
Severity ?
8.8 (High)
CWE
- CWE-287 - Improper Authentication
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ABB | Terra AC wallbox (UL40/80A) |
Affected:
1.0;0 , ≤ 1.5.5
(custom)
|
||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||
Credits
ABB acknowledges and thanks Andi Leach and Puck Meerburg who responsibly disclosed these vulnerabilities and provided valuable input on product improvements. ABB also acknowledges and thanks Lionel R. Saposnik from Saiflow who also responsibly disclosed these vulnerabilities and provided valuable input on product improvements.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T05:24:34.698Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108468A1415\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-0863",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-22T16:50:43.248778Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-22T16:50:53.486Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Terra AC wallbox (UL40/80A)",
"vendor": "ABB",
"versions": [
{
"lessThanOrEqual": "1.5.5",
"status": "affected",
"version": "1.0;0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Terra AC wallbox (UL32A) ",
"vendor": "ABB",
"versions": [
{
"lessThanOrEqual": "1.6.5",
"status": "affected",
"version": "1.0;0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Terra AC wallbox (CE) (Terra AC MID)",
"vendor": "ABB",
"versions": [
{
"lessThanOrEqual": "1.6.5",
"status": "affected",
"version": "1.0;0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Terra AC wallbox (CE) Terra AC Juno CE",
"vendor": "ABB",
"versions": [
{
"lessThanOrEqual": "1.6.5",
"status": "affected",
"version": "1.0;0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Terra AC wallbox (CE) Terra AC PTB ",
"vendor": "ABB",
"versions": [
{
"lessThanOrEqual": "1.5.25",
"status": "affected",
"version": "1.0;0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Terra AC wallbox (CE) Symbiosis",
"vendor": "ABB",
"versions": [
{
"lessThanOrEqual": "1.2.7",
"status": "affected",
"version": "1.0;0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Terra AC wallbox (JP)",
"vendor": "ABB",
"versions": [
{
"lessThanOrEqual": "1.6.5",
"status": "affected",
"version": "1.0;0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "ABB acknowledges and thanks Andi Leach and Puck Meerburg who responsibly disclosed these vulnerabilities and provided valuable input on product improvements. ABB also acknowledges and thanks Lionel R. Saposnik from Saiflow who also responsibly disclosed these vulnerabilities and provided valuable input on product improvements."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Authentication vulnerability in ABB Terra AC wallbox (UL40/80A), ABB Terra AC wallbox (UL32A), ABB Terra AC wallbox (CE) (Terra AC MID), ABB Terra AC wallbox (CE) Terra AC Juno CE, ABB Terra AC wallbox (CE) Terra AC PTB, ABB Terra AC wallbox (CE) Symbiosis, ABB Terra AC wallbox (JP).\u003cp\u003eThis issue affects Terra AC wallbox (UL40/80A): from 1.0;0 through 1.5.5; Terra AC wallbox (UL32A) : from 1.0;0 through 1.6.5; Terra AC wallbox (CE) (Terra AC MID): from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC Juno CE: from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC PTB : from 1.0;0 through 1.5.25; Terra AC wallbox (CE) Symbiosis: from 1.0;0 through 1.2.7; Terra AC wallbox (JP): from 1.0;0 through 1.6.5.\u003c/p\u003e"
}
],
"value": "Improper Authentication vulnerability in ABB Terra AC wallbox (UL40/80A), ABB Terra AC wallbox (UL32A), ABB Terra AC wallbox (CE) (Terra AC MID), ABB Terra AC wallbox (CE) Terra AC Juno CE, ABB Terra AC wallbox (CE) Terra AC PTB, ABB Terra AC wallbox (CE) Symbiosis, ABB Terra AC wallbox (JP).This issue affects Terra AC wallbox (UL40/80A): from 1.0;0 through 1.5.5; Terra AC wallbox (UL32A) : from 1.0;0 through 1.6.5; Terra AC wallbox (CE) (Terra AC MID): from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC Juno CE: from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC PTB : from 1.0;0 through 1.5.25; Terra AC wallbox (CE) Symbiosis: from 1.0;0 through 1.2.7; Terra AC wallbox (JP): from 1.0;0 through 1.6.5.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287 Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-05-17T07:10:46.122Z",
"orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"shortName": "ABB"
},
"references": [
{
"url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108468A1415\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Authentication to access the AC wallbox via its Bluetooth Low Energy (BLE) channel can be bypassed, ",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"assignerShortName": "ABB",
"cveId": "CVE-2023-0863",
"datePublished": "2023-05-17T07:10:46.122Z",
"dateReserved": "2023-02-16T13:04:45.860Z",
"dateUpdated": "2025-01-22T16:50:53.486Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:abb:terra_ac_wallbox_ul40_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"1.0.0\", \"versionEndExcluding\": \"1.5.6\", \"matchCriteriaId\": \"B685842D-EA64-4A3F-ABF9-F0F1B8F852B0\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:abb:terra_ac_wallbox_ul40:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"BCC60C7F-468E-491F-9B1F-7F49713E6715\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:abb:terra_ac_wallbox_80a_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"1.0.0\", \"versionEndExcluding\": \"1.5.6\", \"matchCriteriaId\": \"FD4A0D52-102B-4B87-B62F-E6CF400595FF\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:abb:terra_ac_wallbox_80a:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"8A13EE7D-F159-4F32-8ECE-16452ABB84D1\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:abb:terra_ac_wallbox_ul32a_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"1.0.0\", \"versionEndExcluding\": \"1.6.6\", \"matchCriteriaId\": \"12ABA7C2-C7B9-4A57-8DD0-8C31E01AAFFB\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:abb:terra_ac_wallbox_ul32a:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"87F2647E-594F-4AFE-9F1C-26A64C06BBB7\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:abb:terra_ac_wallbox_jp_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"1.0.0\", \"versionEndExcluding\": \"1.6.6\", \"matchCriteriaId\": \"C177EB89-AECB-43B4-86C4-395C6E09C2FD\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:abb:terra_ac_wallbox_jp:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"11149871-3406-4120-B1AF-A507D72E3E98\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:abb:terra_ac_wallbox_ce_mid_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"1.0.0\", \"versionEndExcluding\": \"1.6.6\", \"matchCriteriaId\": \"63F1B597-42D0-4EDF-883B-B91349991A69\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:abb:terra_ac_wallbox_ce_mid:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"C1437728-6D9B-4740-B904-BF4B41CD54DB\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:abb:terra_ac_wallbox_ce_juno_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"1.0.0\", \"versionEndExcluding\": \"1.6.6\", \"matchCriteriaId\": \"A1D1F228-AC66-42A7-88EB-86F7F1C6098B\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:abb:terra_ac_wallbox_ce_juno:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"C762F36F-D705-49F7-B8FC-8801F03B6048\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:abb:terra_ac_wallbox_ce_ptb_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"1.0.0\", \"versionEndExcluding\": \"1.5.26\", \"matchCriteriaId\": \"DAC89B65-BFE1-4BA9-87F4-D2BA0851012E\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:abb:terra_ac_wallbox_ce_ptb:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"DF28AFF4-3A99-4523-9DBF-4D7D4401C689\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:abb:terra_ac_wallbox_ce_symbiosis_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"1.0.0\", \"versionEndExcluding\": \"1.2.8\", \"matchCriteriaId\": \"A6C630D7-5EE5-4E29-863C-72130F562ABB\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:abb:terra_ac_wallbox_ce_symbiosis:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"40F3A4FB-7933-497B-B85D-73724A9ED60A\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"Improper Authentication vulnerability in ABB Terra AC wallbox (UL40/80A), ABB Terra AC wallbox (UL32A), ABB Terra AC wallbox (CE) (Terra AC MID), ABB Terra AC wallbox (CE) Terra AC Juno CE, ABB Terra AC wallbox (CE) Terra AC PTB, ABB Terra AC wallbox (CE) Symbiosis, ABB Terra AC wallbox (JP).This issue affects Terra AC wallbox (UL40/80A): from 1.0;0 through 1.5.5; Terra AC wallbox (UL32A) : from 1.0;0 through 1.6.5; Terra AC wallbox (CE) (Terra AC MID): from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC Juno CE: from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC PTB : from 1.0;0 through 1.5.25; Terra AC wallbox (CE) Symbiosis: from 1.0;0 through 1.2.7; Terra AC wallbox (JP): from 1.0;0 through 1.6.5.\\n\\n\"}]",
"id": "CVE-2023-0863",
"lastModified": "2024-11-21T07:37:59.653",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"cybersecurity@ch.abb.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"ADJACENT_NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 5.9}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"ADJACENT_NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 5.9}]}",
"published": "2023-05-17T08:15:08.510",
"references": "[{\"url\": \"https://search.abb.com/library/Download.aspx?DocumentID=9AKK108468A1415\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\", \"source\": \"cybersecurity@ch.abb.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://search.abb.com/library/Download.aspx?DocumentID=9AKK108468A1415\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
"sourceIdentifier": "cybersecurity@ch.abb.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"cybersecurity@ch.abb.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-287\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-287\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2023-0863\",\"sourceIdentifier\":\"cybersecurity@ch.abb.com\",\"published\":\"2023-05-17T08:15:08.510\",\"lastModified\":\"2024-11-21T07:37:59.653\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Improper Authentication vulnerability in ABB Terra AC wallbox (UL40/80A), ABB Terra AC wallbox (UL32A), ABB Terra AC wallbox (CE) (Terra AC MID), ABB Terra AC wallbox (CE) Terra AC Juno CE, ABB Terra AC wallbox (CE) Terra AC PTB, ABB Terra AC wallbox (CE) Symbiosis, ABB Terra AC wallbox (JP).This issue affects Terra AC wallbox (UL40/80A): from 1.0;0 through 1.5.5; Terra AC wallbox (UL32A) : from 1.0;0 through 1.6.5; Terra AC wallbox (CE) (Terra AC MID): from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC Juno CE: from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC PTB : from 1.0;0 through 1.5.25; Terra AC wallbox (CE) Symbiosis: from 1.0;0 through 1.2.7; Terra AC wallbox (JP): from 1.0;0 through 1.6.5.\\n\\n\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cybersecurity@ch.abb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"cybersecurity@ch.abb.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-287\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-287\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:abb:terra_ac_wallbox_ul40_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"1.0.0\",\"versionEndExcluding\":\"1.5.6\",\"matchCriteriaId\":\"B685842D-EA64-4A3F-ABF9-F0F1B8F852B0\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:abb:terra_ac_wallbox_ul40:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BCC60C7F-468E-491F-9B1F-7F49713E6715\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:abb:terra_ac_wallbox_80a_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"1.0.0\",\"versionEndExcluding\":\"1.5.6\",\"matchCriteriaId\":\"FD4A0D52-102B-4B87-B62F-E6CF400595FF\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:abb:terra_ac_wallbox_80a:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8A13EE7D-F159-4F32-8ECE-16452ABB84D1\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:abb:terra_ac_wallbox_ul32a_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"1.0.0\",\"versionEndExcluding\":\"1.6.6\",\"matchCriteriaId\":\"12ABA7C2-C7B9-4A57-8DD0-8C31E01AAFFB\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:abb:terra_ac_wallbox_ul32a:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"87F2647E-594F-4AFE-9F1C-26A64C06BBB7\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:abb:terra_ac_wallbox_jp_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"1.0.0\",\"versionEndExcluding\":\"1.6.6\",\"matchCriteriaId\":\"C177EB89-AECB-43B4-86C4-395C6E09C2FD\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:abb:terra_ac_wallbox_jp:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"11149871-3406-4120-B1AF-A507D72E3E98\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:abb:terra_ac_wallbox_ce_mid_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"1.0.0\",\"versionEndExcluding\":\"1.6.6\",\"matchCriteriaId\":\"63F1B597-42D0-4EDF-883B-B91349991A69\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:abb:terra_ac_wallbox_ce_mid:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C1437728-6D9B-4740-B904-BF4B41CD54DB\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:abb:terra_ac_wallbox_ce_juno_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"1.0.0\",\"versionEndExcluding\":\"1.6.6\",\"matchCriteriaId\":\"A1D1F228-AC66-42A7-88EB-86F7F1C6098B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:abb:terra_ac_wallbox_ce_juno:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C762F36F-D705-49F7-B8FC-8801F03B6048\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:abb:terra_ac_wallbox_ce_ptb_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"1.0.0\",\"versionEndExcluding\":\"1.5.26\",\"matchCriteriaId\":\"DAC89B65-BFE1-4BA9-87F4-D2BA0851012E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:abb:terra_ac_wallbox_ce_ptb:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DF28AFF4-3A99-4523-9DBF-4D7D4401C689\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:abb:terra_ac_wallbox_ce_symbiosis_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"1.0.0\",\"versionEndExcluding\":\"1.2.8\",\"matchCriteriaId\":\"A6C630D7-5EE5-4E29-863C-72130F562ABB\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:abb:terra_ac_wallbox_ce_symbiosis:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"40F3A4FB-7933-497B-B85D-73724A9ED60A\"}]}]}],\"references\":[{\"url\":\"https://search.abb.com/library/Download.aspx?DocumentID=9AKK108468A1415\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\",\"source\":\"cybersecurity@ch.abb.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://search.abb.com/library/Download.aspx?DocumentID=9AKK108468A1415\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://search.abb.com/library/Download.aspx?DocumentID=9AKK108468A1415\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T05:24:34.698Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-0863\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-01-22T16:50:43.248778Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-01-22T16:50:47.121Z\"}}], \"cna\": {\"title\": \"Authentication to access the AC wallbox via its Bluetooth Low Energy (BLE) channel can be bypassed, \", \"source\": {\"discovery\": \"UNKNOWN\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"user\": \"00000000-0000-4000-9000-000000000000\", \"value\": \"ABB acknowledges and thanks Andi Leach and Puck Meerburg who responsibly disclosed these vulnerabilities and provided valuable input on product improvements. ABB also acknowledges and thanks Lionel R. Saposnik from Saiflow who also responsibly disclosed these vulnerabilities and provided valuable input on product improvements.\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 8.8, \"attackVector\": \"ADJACENT_NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"ABB\", \"product\": \"Terra AC wallbox (UL40/80A)\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.0;0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"1.5.5\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"ABB\", \"product\": \"Terra AC wallbox (UL32A) \", \"versions\": [{\"status\": \"affected\", \"version\": \"1.0;0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"1.6.5\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"ABB\", \"product\": \"Terra AC wallbox (CE) (Terra AC MID)\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.0;0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"1.6.5\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"ABB\", \"product\": \"Terra AC wallbox (CE) Terra AC Juno CE\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.0;0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"1.6.5\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"ABB\", \"product\": \"Terra AC wallbox (CE) Terra AC PTB \", \"versions\": [{\"status\": \"affected\", \"version\": \"1.0;0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"1.5.25\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"ABB\", \"product\": \"Terra AC wallbox (CE) Symbiosis\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.0;0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"1.2.7\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"ABB\", \"product\": \"Terra AC wallbox (JP)\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.0;0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"1.6.5\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://search.abb.com/library/Download.aspx?DocumentID=9AKK108468A1415\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Improper Authentication vulnerability in ABB Terra AC wallbox (UL40/80A), ABB Terra AC wallbox (UL32A), ABB Terra AC wallbox (CE) (Terra AC MID), ABB Terra AC wallbox (CE) Terra AC Juno CE, ABB Terra AC wallbox (CE) Terra AC PTB, ABB Terra AC wallbox (CE) Symbiosis, ABB Terra AC wallbox (JP).This issue affects Terra AC wallbox (UL40/80A): from 1.0;0 through 1.5.5; Terra AC wallbox (UL32A) : from 1.0;0 through 1.6.5; Terra AC wallbox (CE) (Terra AC MID): from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC Juno CE: from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC PTB : from 1.0;0 through 1.5.25; Terra AC wallbox (CE) Symbiosis: from 1.0;0 through 1.2.7; Terra AC wallbox (JP): from 1.0;0 through 1.6.5.\\n\\n\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Improper Authentication vulnerability in ABB Terra AC wallbox (UL40/80A), ABB Terra AC wallbox (UL32A), ABB Terra AC wallbox (CE) (Terra AC MID), ABB Terra AC wallbox (CE) Terra AC Juno CE, ABB Terra AC wallbox (CE) Terra AC PTB, ABB Terra AC wallbox (CE) Symbiosis, ABB Terra AC wallbox (JP).\u003cp\u003eThis issue affects Terra AC wallbox (UL40/80A): from 1.0;0 through 1.5.5; Terra AC wallbox (UL32A) : from 1.0;0 through 1.6.5; Terra AC wallbox (CE) (Terra AC MID): from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC Juno CE: from 1.0;0 through 1.6.5; Terra AC wallbox (CE) Terra AC PTB : from 1.0;0 through 1.5.25; Terra AC wallbox (CE) Symbiosis: from 1.0;0 through 1.2.7; Terra AC wallbox (JP): from 1.0;0 through 1.6.5.\u003c/p\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-287\", \"description\": \"CWE-287 Improper Authentication\"}]}], \"providerMetadata\": {\"orgId\": \"2b718523-d88f-4f37-9bbd-300c20644bf9\", \"shortName\": \"ABB\", \"dateUpdated\": \"2023-05-17T07:10:46.122Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2023-0863\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-01-22T16:50:53.486Z\", \"dateReserved\": \"2023-02-16T13:04:45.860Z\", \"assignerOrgId\": \"2b718523-d88f-4f37-9bbd-300c20644bf9\", \"datePublished\": \"2023-05-17T07:10:46.122Z\", \"assignerShortName\": \"ABB\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…