CVE-2023-21993 (GCVE-0-2023-21993)
Vulnerability from cvelistv5 – Published: 2023-04-18 19:54 – Updated: 2024-09-16 14:43
VLAI?
Summary
Vulnerability in the Oracle Clinical Remote Data Capture product of Oracle Health Sciences Applications (component: Forms). The supported version that is affected is 5.4.0.2. Easily exploitable vulnerability allows low privileged attacker with network access via HTTP to compromise Oracle Clinical Remote Data Capture. Successful attacks of this vulnerability can result in unauthorized access to critical data or complete access to all Oracle Clinical Remote Data Capture accessible data. CVSS 3.1 Base Score 6.5 (Confidentiality impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N).
Severity ?
6.5 (Medium)
CWE
- Easily exploitable vulnerability allows low privileged attacker with network access via HTTP to compromise Oracle Clinical Remote Data Capture. Successful attacks of this vulnerability can result in unauthorized access to critical data or complete access to all Oracle Clinical Remote Data Capture accessible data.
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Oracle Corporation | Clinical Remote Data Capture Option |
Affected:
5.4.0.2
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T09:59:28.547Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "Oracle Advisory",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.oracle.com/security-alerts/cpuapr2023.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-21993",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-16T14:38:26.620211Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-16T14:43:40.233Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Clinical Remote Data Capture Option",
"vendor": "Oracle Corporation",
"versions": [
{
"status": "affected",
"version": "5.4.0.2"
}
]
}
],
"descriptions": [
{
"lang": "en-US",
"value": "Vulnerability in the Oracle Clinical Remote Data Capture product of Oracle Health Sciences Applications (component: Forms). The supported version that is affected is 5.4.0.2. Easily exploitable vulnerability allows low privileged attacker with network access via HTTP to compromise Oracle Clinical Remote Data Capture. Successful attacks of this vulnerability can result in unauthorized access to critical data or complete access to all Oracle Clinical Remote Data Capture accessible data. CVSS 3.1 Base Score 6.5 (Confidentiality impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N)."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Easily exploitable vulnerability allows low privileged attacker with network access via HTTP to compromise Oracle Clinical Remote Data Capture. Successful attacks of this vulnerability can result in unauthorized access to critical data or complete access to all Oracle Clinical Remote Data Capture accessible data.",
"lang": "en-US"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-18T19:54:43.264Z",
"orgId": "43595867-4340-4103-b7a2-9a5208d29a85",
"shortName": "oracle"
},
"references": [
{
"name": "Oracle Advisory",
"tags": [
"vendor-advisory"
],
"url": "https://www.oracle.com/security-alerts/cpuapr2023.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "43595867-4340-4103-b7a2-9a5208d29a85",
"assignerShortName": "oracle",
"cveId": "CVE-2023-21993",
"datePublished": "2023-04-18T19:54:43.264Z",
"dateReserved": "2022-12-17T19:26:00.741Z",
"dateUpdated": "2024-09-16T14:43:40.233Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:oracle:clinical_remote_data_capture:5.4.0.2:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"73DA7077-6EE5-44E2-BE90-2E0E8E3CEC7E\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"Vulnerability in the Oracle Clinical Remote Data Capture product of Oracle Health Sciences Applications (component: Forms). The supported version that is affected is 5.4.0.2. Easily exploitable vulnerability allows low privileged attacker with network access via HTTP to compromise Oracle Clinical Remote Data Capture. Successful attacks of this vulnerability can result in unauthorized access to critical data or complete access to all Oracle Clinical Remote Data Capture accessible data. CVSS 3.1 Base Score 6.5 (Confidentiality impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N).\"}]",
"id": "CVE-2023-21993",
"lastModified": "2024-11-21T07:44:03.963",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"secalert_us@oracle.com\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\", \"baseScore\": 6.5, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 3.6}]}",
"published": "2023-04-18T20:15:18.123",
"references": "[{\"url\": \"https://www.oracle.com/security-alerts/cpuapr2023.html\", \"source\": \"secalert_us@oracle.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://www.oracle.com/security-alerts/cpuapr2023.html\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
"sourceIdentifier": "secalert_us@oracle.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"NVD-CWE-noinfo\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2023-21993\",\"sourceIdentifier\":\"secalert_us@oracle.com\",\"published\":\"2023-04-18T20:15:18.123\",\"lastModified\":\"2024-11-21T07:44:03.963\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Vulnerability in the Oracle Clinical Remote Data Capture product of Oracle Health Sciences Applications (component: Forms). The supported version that is affected is 5.4.0.2. Easily exploitable vulnerability allows low privileged attacker with network access via HTTP to compromise Oracle Clinical Remote Data Capture. Successful attacks of this vulnerability can result in unauthorized access to critical data or complete access to all Oracle Clinical Remote Data Capture accessible data. CVSS 3.1 Base Score 6.5 (Confidentiality impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N).\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"secalert_us@oracle.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:oracle:clinical_remote_data_capture:5.4.0.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"73DA7077-6EE5-44E2-BE90-2E0E8E3CEC7E\"}]}]}],\"references\":[{\"url\":\"https://www.oracle.com/security-alerts/cpuapr2023.html\",\"source\":\"secalert_us@oracle.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.oracle.com/security-alerts/cpuapr2023.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.oracle.com/security-alerts/cpuapr2023.html\", \"name\": \"Oracle Advisory\", \"tags\": [\"vendor-advisory\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T09:59:28.547Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-21993\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-09-16T14:38:26.620211Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-09-16T14:43:22.275Z\"}}], \"cna\": {\"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 6.5, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"HIGH\"}}], \"affected\": [{\"vendor\": \"Oracle Corporation\", \"product\": \"Clinical Remote Data Capture Option\", \"versions\": [{\"status\": \"affected\", \"version\": \"5.4.0.2\"}]}], \"references\": [{\"url\": \"https://www.oracle.com/security-alerts/cpuapr2023.html\", \"name\": \"Oracle Advisory\", \"tags\": [\"vendor-advisory\"]}], \"descriptions\": [{\"lang\": \"en-US\", \"value\": \"Vulnerability in the Oracle Clinical Remote Data Capture product of Oracle Health Sciences Applications (component: Forms). The supported version that is affected is 5.4.0.2. Easily exploitable vulnerability allows low privileged attacker with network access via HTTP to compromise Oracle Clinical Remote Data Capture. Successful attacks of this vulnerability can result in unauthorized access to critical data or complete access to all Oracle Clinical Remote Data Capture accessible data. CVSS 3.1 Base Score 6.5 (Confidentiality impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N).\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en-US\", \"description\": \"Easily exploitable vulnerability allows low privileged attacker with network access via HTTP to compromise Oracle Clinical Remote Data Capture. Successful attacks of this vulnerability can result in unauthorized access to critical data or complete access to all Oracle Clinical Remote Data Capture accessible data.\"}]}], \"providerMetadata\": {\"orgId\": \"43595867-4340-4103-b7a2-9a5208d29a85\", \"shortName\": \"oracle\", \"dateUpdated\": \"2023-04-18T19:54:43.264Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2023-21993\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-09-16T14:43:40.233Z\", \"dateReserved\": \"2022-12-17T19:26:00.741Z\", \"assignerOrgId\": \"43595867-4340-4103-b7a2-9a5208d29a85\", \"datePublished\": \"2023-04-18T19:54:43.264Z\", \"assignerShortName\": \"oracle\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…