cve-2023-22575
Vulnerability from cvelistv5
Published
2023-02-01 13:16
Modified
2024-08-02 10:13
Summary
Dell PowerScale OneFS 9.0.0.x - 9.4.0.x contain an insertion of sensitive information into log file vulnerability in celog. A low privileges user could potentially exploit this vulnerability, leading to information disclosure and escalation of privileges.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T10:13:48.987Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000207863/dell-powerscale-onefs-security-updates-for-multiple-security"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerScale OneFS",
          "vendor": "Dell",
          "versions": [
            {
              "lessThanOrEqual": "9.1.0.0 through 9.1.0.26",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "9.2.1.0 through 9.2.1.19",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "9.4.0.0 through 9.4.0.10",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2023-01-31T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.dell.com/support/kbdoc/en-us/000207863/dell-powerscale-onefs-security-updates-for-multiple-security\"\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell PowerScale OneFS 9.0.0.x - 9.4.0.x contain an insertion of sensitive information into log file vulnerability in celog. A low privileges user could potentially exploit this vulnerability, leading to information disclosure and escalation of privileges.\u003c/span\u003e\n\n\u003c/a\u003e"
            }
          ],
          "value": "Dell PowerScale OneFS 9.0.0.x - 9.4.0.x contain an insertion of sensitive information into log file vulnerability in celog. A low privileges user could potentially exploit this vulnerability, leading to information disclosure and escalation of privileges.\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-532",
              "description": "CWE-532: Insertion of Sensitive Information into Log File",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-02-01T13:16:56.674Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000207863/dell-powerscale-onefs-security-updates-for-multiple-security"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2023-22575",
    "datePublished": "2023-02-01T13:16:56.674Z",
    "dateReserved": "2023-01-02T12:54:59.731Z",
    "dateUpdated": "2024-08-02T10:13:48.987Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2023-22575\",\"sourceIdentifier\":\"security_alert@emc.com\",\"published\":\"2023-02-01T14:15:09.540\",\"lastModified\":\"2023-11-07T04:07:03.910\",\"vulnStatus\":\"Modified\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"Dell PowerScale OneFS 9.0.0.x - 9.4.0.x contain an insertion of sensitive information into log file vulnerability in celog. A low privileges user could potentially exploit this vulnerability, leading to information disclosure and escalation of privileges.\\n\\n\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9},{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:N\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\",\"baseScore\":8.7,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":2.3,\"impactScore\":5.8}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-532\"}]},{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-532\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:emc_powerscale_onefs:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"9.1.0.0\",\"versionEndExcluding\":\"9.1.0.27\",\"matchCriteriaId\":\"D9D60B42-263C-400D-AFD6-62EF2A6043F4\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:emc_powerscale_onefs:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"9.2.1.0\",\"versionEndExcluding\":\"9.2.1.20\",\"matchCriteriaId\":\"B800B3F7-925B-409C-ABFC-0AA9BA92835A\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:emc_powerscale_onefs:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"9.4.0.0\",\"versionEndExcluding\":\"9.4.0.11\",\"matchCriteriaId\":\"C78B8E43-AB76-48CD-A626-31D54F1ADFDC\"}]}]}],\"references\":[{\"url\":\"https://www.dell.com/support/kbdoc/en-us/000207863/dell-powerscale-onefs-security-updates-for-multiple-security\",\"source\":\"security_alert@emc.com\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.