Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2023-37374 (GCVE-0-2023-37374)
Vulnerability from cvelistv5 – Published: 2023-07-11 09:07 – Updated: 2024-11-08 16:59- CWE-121 - Stack-based Buffer Overflow
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Siemens | Tecnomatix Plant Simulation V2201 |
Affected:
All versions < V2201.0008
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:09:34.118Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-764801.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-37374",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-08T16:59:42.616277Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-08T16:59:50.279Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2201",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2201.0008"
}
]
},
{
"defaultStatus": "unknown",
"product": "Tecnomatix Plant Simulation V2302",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2302.0002"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions \u003c V2201.0008), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0002). The affected application is vulnerable to stack-based buffer overflow while parsing specially crafted STP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21054)"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121: Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-09-12T09:32:10.553Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-764801.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-37374",
"datePublished": "2023-07-11T09:07:26.462Z",
"dateReserved": "2023-07-03T13:24:27.345Z",
"dateUpdated": "2024-11-08T16:59:50.279Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2023-37374",
"date": "2026-04-17",
"epss": "0.00099",
"percentile": "0.27582"
},
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:tecnomatix:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"2201\", \"versionEndExcluding\": \"2201.0008\", \"matchCriteriaId\": \"0E8C9093-BD78-4ECE-9221-A889371B3839\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:tecnomatix:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"2302\", \"versionEndExcluding\": \"2302.0002\", \"matchCriteriaId\": \"C7103507-EE73-42FF-9DAB-37DD06467591\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions \u003c V2201.0008), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0002). The affected application is vulnerable to stack-based buffer overflow while parsing specially crafted STP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21054)\"}]",
"id": "CVE-2023-37374",
"lastModified": "2024-11-21T08:11:36.350",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"productcert@siemens.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\", \"baseScore\": 7.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 5.9}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\", \"baseScore\": 7.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 5.9}]}",
"published": "2023-07-11T10:15:11.743",
"references": "[{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-764801.pdf\", \"source\": \"productcert@siemens.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-764801.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"productcert@siemens.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-121\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-787\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2023-37374\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2023-07-11T10:15:11.743\",\"lastModified\":\"2024-11-21T08:11:36.350\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions \u003c V2201.0008), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0002). The affected application is vulnerable to stack-based buffer overflow while parsing specially crafted STP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21054)\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-121\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:tecnomatix:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2201\",\"versionEndExcluding\":\"2201.0008\",\"matchCriteriaId\":\"0E8C9093-BD78-4ECE-9221-A889371B3839\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:tecnomatix:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"2302\",\"versionEndExcluding\":\"2302.0002\",\"matchCriteriaId\":\"C7103507-EE73-42FF-9DAB-37DD06467591\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-764801.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-764801.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-764801.pdf\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T17:09:34.118Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-37374\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-11-08T16:59:42.616277Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-11-08T16:59:46.622Z\"}}], \"cna\": {\"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 7.8, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C\"}}], \"affected\": [{\"vendor\": \"Siemens\", \"product\": \"Tecnomatix Plant Simulation V2201\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003c V2201.0008\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Tecnomatix Plant Simulation V2302\", \"versions\": [{\"status\": \"affected\", \"version\": \"All versions \u003c V2302.0002\"}], \"defaultStatus\": \"unknown\"}], \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-764801.pdf\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions \u003c V2201.0008), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0002). The affected application is vulnerable to stack-based buffer overflow while parsing specially crafted STP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21054)\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-121\", \"description\": \"CWE-121: Stack-based Buffer Overflow\"}]}], \"providerMetadata\": {\"orgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"shortName\": \"siemens\", \"dateUpdated\": \"2023-09-12T09:32:10.553Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2023-37374\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-11-08T16:59:50.279Z\", \"dateReserved\": \"2023-07-03T13:24:27.345Z\", \"assignerOrgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"datePublished\": \"2023-07-11T09:07:26.462Z\", \"assignerShortName\": \"siemens\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
CERTFR-2023-AVI-0526
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | N/A | SIMATIC MV540 H (6GF3540-0GE10) versions antérieures à 3.3.4 | ||
| Siemens | N/A | SIMATIC MV560 X (6GF3560-0HE10) versions antérieures à 3.3.4 | ||
| Siemens | N/A | RUGGEDCOM ROX RX5000 versions antérieures à 2.16.0 | ||
| Siemens | N/A | RUGGEDCOM ROX MX5000 versions antérieures à 2.16.0 | ||
| Siemens | N/A | Tecnomatix Plant Simulation versions 2302.x antérieures à 2302.0002 | ||
| Siemens | N/A | SIMATIC MV540 S (6GF3540-0CD10) versions antérieures à 3.3.4 | ||
| Siemens | N/A | RUGGEDCOM ROX RX1512 versions antérieures à 2.16.0 | ||
| Siemens | N/A | RUGGEDCOM ROX RX1501 versions antérieures à 2.16.0 | ||
| Siemens | N/A | SIMATIC MV550 H (6GF3550-0GE10) versions antérieures à 3.3.4 | ||
| Siemens | N/A | RUGGEDCOM ROX RX1524 versions antérieures à 2.16.0 | ||
| Siemens | N/A | SIMATIC MV550 S (6GF3550-0CD10) versions antérieures à 3.3.4 | ||
| Siemens | N/A | SIMATIC MV560 U (6GF3560-0LE10) versions antérieures à 3.3.4 | ||
| Siemens | N/A | RUGGEDCOM ROX RX1536 versions antérieures à 2.16.0 | ||
| Siemens | N/A | RUGGEDCOM ROX RX1400 versions antérieures à 2.16.0 | ||
| Siemens | N/A | SIMATIC CN 4100 versions antérieures à 2.5 | ||
| Siemens | N/A | RUGGEDCOM ROX RX1511 versions antérieures à 2.16.0 | ||
| Siemens | N/A | RUGGEDCOM ROX RX1500 versions antérieures à 2.16.0 | ||
| Siemens | N/A | RUGGEDCOM ROX RX1510 versions antérieures à 2.16.0 | ||
| Siemens | N/A | Tecnomatix Plant Simulation versions 2201.x antérieures à 2201.0008 | ||
| Siemens | N/A | SiPass integrated versions antérieures à 2.90.3.8 | ||
| Siemens | N/A | RUGGEDCOM ROX MX5000RE versions antérieures à 2.16.0 |
| Title | Publication Time | Tags | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "SIMATIC MV540 H (6GF3540-0GE10) versions ant\u00e9rieures \u00e0 3.3.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC MV560 X (6GF3560-0HE10) versions ant\u00e9rieures \u00e0 3.3.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM ROX RX5000 versions ant\u00e9rieures \u00e0 2.16.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM ROX MX5000 versions ant\u00e9rieures \u00e0 2.16.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Tecnomatix Plant Simulation versions 2302.x ant\u00e9rieures \u00e0 2302.0002",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC MV540 S (6GF3540-0CD10) versions ant\u00e9rieures \u00e0 3.3.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM ROX RX1512 versions ant\u00e9rieures \u00e0 2.16.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM ROX RX1501 versions ant\u00e9rieures \u00e0 2.16.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC MV550 H (6GF3550-0GE10) versions ant\u00e9rieures \u00e0 3.3.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM ROX RX1524 versions ant\u00e9rieures \u00e0 2.16.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC MV550 S (6GF3550-0CD10) versions ant\u00e9rieures \u00e0 3.3.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC MV560 U (6GF3560-0LE10) versions ant\u00e9rieures \u00e0 3.3.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM ROX RX1536 versions ant\u00e9rieures \u00e0 2.16.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM ROX RX1400 versions ant\u00e9rieures \u00e0 2.16.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CN 4100 versions ant\u00e9rieures \u00e0 2.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM ROX RX1511 versions ant\u00e9rieures \u00e0 2.16.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM ROX RX1500 versions ant\u00e9rieures \u00e0 2.16.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM ROX RX1510 versions ant\u00e9rieures \u00e0 2.16.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Tecnomatix Plant Simulation versions 2201.x ant\u00e9rieures \u00e0 2201.0008",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SiPass integrated versions ant\u00e9rieures \u00e0 2.90.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM ROX MX5000RE versions ant\u00e9rieures \u00e0 2.16.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2023-36751",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-36751"
},
{
"name": "CVE-2023-37247",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-37247"
},
{
"name": "CVE-2022-27781",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-27781"
},
{
"name": "CVE-2022-4304",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4304"
},
{
"name": "CVE-2023-36755",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-36755"
},
{
"name": "CVE-2022-1292",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-1292"
},
{
"name": "CVE-2023-36753",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-36753"
},
{
"name": "CVE-2023-36749",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-36749"
},
{
"name": "CVE-2022-32207",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32207"
},
{
"name": "CVE-2023-0215",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0215"
},
{
"name": "CVE-2023-0286",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0286"
},
{
"name": "CVE-2022-48285",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-48285"
},
{
"name": "CVE-2023-36390",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-36390"
},
{
"name": "CVE-2023-37376",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-37376"
},
{
"name": "CVE-2023-36389",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-36389"
},
{
"name": "CVE-2023-36750",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-36750"
},
{
"name": "CVE-2023-29131",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-29131"
},
{
"name": "CVE-2022-2068",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-2068"
},
{
"name": "CVE-2023-36521",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-36521"
},
{
"name": "CVE-2022-27782",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-27782"
},
{
"name": "CVE-2022-22576",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22576"
},
{
"name": "CVE-2021-22946",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22946"
},
{
"name": "CVE-2023-35920",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-35920"
},
{
"name": "CVE-2023-29130",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-29130"
},
{
"name": "CVE-2022-29562",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-29562"
},
{
"name": "CVE-2021-46828",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-46828"
},
{
"name": "CVE-2019-14196",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-14196"
},
{
"name": "CVE-2023-35921",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-35921"
},
{
"name": "CVE-2023-36754",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-36754"
},
{
"name": "CVE-2022-37434",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-37434"
},
{
"name": "CVE-2023-36752",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-36752"
},
{
"name": "CVE-2022-1012",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-1012"
},
{
"name": "CVE-2022-4450",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4450"
},
{
"name": "CVE-2023-36386",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-36386"
},
{
"name": "CVE-2023-37374",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-37374"
},
{
"name": "CVE-2022-36946",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-36946"
},
{
"name": "CVE-2023-37375",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-37375"
},
{
"name": "CVE-2022-29561",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-29561"
},
{
"name": "CVE-2022-30767",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-30767"
},
{
"name": "CVE-2023-36748",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-36748"
},
{
"name": "CVE-2023-37248",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-37248"
},
{
"name": "CVE-2022-31810",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-31810"
},
{
"name": "CVE-2023-37246",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-37246"
},
{
"name": "CVE-2022-24903",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24903"
}
],
"links": [],
"reference": "CERTFR-2023-AVI-0526",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2023-07-11T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Injection de code indirecte \u00e0 distance (XSS)"
},
{
"description": "Injection de requ\u00eates ill\u00e9gitimes par rebond (CSRF)"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service \u00e0\ndistance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-764801 du 11 juillet 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-764801.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-561322 du 11 juillet 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-561322.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-313488 du 11 juillet 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-313488.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-924149 du 11 juillet 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-924149.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-146325 du 11 juillet 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-146325.html"
}
]
}
CERTFR-2023-AVI-0526
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | N/A | SIMATIC MV540 H (6GF3540-0GE10) versions antérieures à 3.3.4 | ||
| Siemens | N/A | SIMATIC MV560 X (6GF3560-0HE10) versions antérieures à 3.3.4 | ||
| Siemens | N/A | RUGGEDCOM ROX RX5000 versions antérieures à 2.16.0 | ||
| Siemens | N/A | RUGGEDCOM ROX MX5000 versions antérieures à 2.16.0 | ||
| Siemens | N/A | Tecnomatix Plant Simulation versions 2302.x antérieures à 2302.0002 | ||
| Siemens | N/A | SIMATIC MV540 S (6GF3540-0CD10) versions antérieures à 3.3.4 | ||
| Siemens | N/A | RUGGEDCOM ROX RX1512 versions antérieures à 2.16.0 | ||
| Siemens | N/A | RUGGEDCOM ROX RX1501 versions antérieures à 2.16.0 | ||
| Siemens | N/A | SIMATIC MV550 H (6GF3550-0GE10) versions antérieures à 3.3.4 | ||
| Siemens | N/A | RUGGEDCOM ROX RX1524 versions antérieures à 2.16.0 | ||
| Siemens | N/A | SIMATIC MV550 S (6GF3550-0CD10) versions antérieures à 3.3.4 | ||
| Siemens | N/A | SIMATIC MV560 U (6GF3560-0LE10) versions antérieures à 3.3.4 | ||
| Siemens | N/A | RUGGEDCOM ROX RX1536 versions antérieures à 2.16.0 | ||
| Siemens | N/A | RUGGEDCOM ROX RX1400 versions antérieures à 2.16.0 | ||
| Siemens | N/A | SIMATIC CN 4100 versions antérieures à 2.5 | ||
| Siemens | N/A | RUGGEDCOM ROX RX1511 versions antérieures à 2.16.0 | ||
| Siemens | N/A | RUGGEDCOM ROX RX1500 versions antérieures à 2.16.0 | ||
| Siemens | N/A | RUGGEDCOM ROX RX1510 versions antérieures à 2.16.0 | ||
| Siemens | N/A | Tecnomatix Plant Simulation versions 2201.x antérieures à 2201.0008 | ||
| Siemens | N/A | SiPass integrated versions antérieures à 2.90.3.8 | ||
| Siemens | N/A | RUGGEDCOM ROX MX5000RE versions antérieures à 2.16.0 |
| Title | Publication Time | Tags | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "SIMATIC MV540 H (6GF3540-0GE10) versions ant\u00e9rieures \u00e0 3.3.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC MV560 X (6GF3560-0HE10) versions ant\u00e9rieures \u00e0 3.3.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM ROX RX5000 versions ant\u00e9rieures \u00e0 2.16.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM ROX MX5000 versions ant\u00e9rieures \u00e0 2.16.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Tecnomatix Plant Simulation versions 2302.x ant\u00e9rieures \u00e0 2302.0002",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC MV540 S (6GF3540-0CD10) versions ant\u00e9rieures \u00e0 3.3.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM ROX RX1512 versions ant\u00e9rieures \u00e0 2.16.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM ROX RX1501 versions ant\u00e9rieures \u00e0 2.16.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC MV550 H (6GF3550-0GE10) versions ant\u00e9rieures \u00e0 3.3.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM ROX RX1524 versions ant\u00e9rieures \u00e0 2.16.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC MV550 S (6GF3550-0CD10) versions ant\u00e9rieures \u00e0 3.3.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC MV560 U (6GF3560-0LE10) versions ant\u00e9rieures \u00e0 3.3.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM ROX RX1536 versions ant\u00e9rieures \u00e0 2.16.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM ROX RX1400 versions ant\u00e9rieures \u00e0 2.16.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CN 4100 versions ant\u00e9rieures \u00e0 2.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM ROX RX1511 versions ant\u00e9rieures \u00e0 2.16.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM ROX RX1500 versions ant\u00e9rieures \u00e0 2.16.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM ROX RX1510 versions ant\u00e9rieures \u00e0 2.16.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Tecnomatix Plant Simulation versions 2201.x ant\u00e9rieures \u00e0 2201.0008",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SiPass integrated versions ant\u00e9rieures \u00e0 2.90.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM ROX MX5000RE versions ant\u00e9rieures \u00e0 2.16.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2023-36751",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-36751"
},
{
"name": "CVE-2023-37247",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-37247"
},
{
"name": "CVE-2022-27781",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-27781"
},
{
"name": "CVE-2022-4304",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4304"
},
{
"name": "CVE-2023-36755",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-36755"
},
{
"name": "CVE-2022-1292",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-1292"
},
{
"name": "CVE-2023-36753",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-36753"
},
{
"name": "CVE-2023-36749",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-36749"
},
{
"name": "CVE-2022-32207",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32207"
},
{
"name": "CVE-2023-0215",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0215"
},
{
"name": "CVE-2023-0286",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0286"
},
{
"name": "CVE-2022-48285",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-48285"
},
{
"name": "CVE-2023-36390",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-36390"
},
{
"name": "CVE-2023-37376",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-37376"
},
{
"name": "CVE-2023-36389",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-36389"
},
{
"name": "CVE-2023-36750",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-36750"
},
{
"name": "CVE-2023-29131",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-29131"
},
{
"name": "CVE-2022-2068",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-2068"
},
{
"name": "CVE-2023-36521",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-36521"
},
{
"name": "CVE-2022-27782",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-27782"
},
{
"name": "CVE-2022-22576",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22576"
},
{
"name": "CVE-2021-22946",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22946"
},
{
"name": "CVE-2023-35920",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-35920"
},
{
"name": "CVE-2023-29130",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-29130"
},
{
"name": "CVE-2022-29562",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-29562"
},
{
"name": "CVE-2021-46828",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-46828"
},
{
"name": "CVE-2019-14196",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-14196"
},
{
"name": "CVE-2023-35921",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-35921"
},
{
"name": "CVE-2023-36754",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-36754"
},
{
"name": "CVE-2022-37434",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-37434"
},
{
"name": "CVE-2023-36752",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-36752"
},
{
"name": "CVE-2022-1012",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-1012"
},
{
"name": "CVE-2022-4450",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4450"
},
{
"name": "CVE-2023-36386",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-36386"
},
{
"name": "CVE-2023-37374",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-37374"
},
{
"name": "CVE-2022-36946",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-36946"
},
{
"name": "CVE-2023-37375",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-37375"
},
{
"name": "CVE-2022-29561",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-29561"
},
{
"name": "CVE-2022-30767",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-30767"
},
{
"name": "CVE-2023-36748",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-36748"
},
{
"name": "CVE-2023-37248",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-37248"
},
{
"name": "CVE-2022-31810",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-31810"
},
{
"name": "CVE-2023-37246",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-37246"
},
{
"name": "CVE-2022-24903",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24903"
}
],
"links": [],
"reference": "CERTFR-2023-AVI-0526",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2023-07-11T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Injection de code indirecte \u00e0 distance (XSS)"
},
{
"description": "Injection de requ\u00eates ill\u00e9gitimes par rebond (CSRF)"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service \u00e0\ndistance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-764801 du 11 juillet 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-764801.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-561322 du 11 juillet 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-561322.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-313488 du 11 juillet 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-313488.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-924149 du 11 juillet 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-924149.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-146325 du 11 juillet 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-146325.html"
}
]
}
VAR-202307-0576
Vulnerability from variot - Updated: 2024-01-21 20:33A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0002). The affected application is vulnerable to stack-based buffer overflow while parsing specially crafted STP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21054). Siemens' tecnomatix Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Tecnomatix Plant Simulation. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of STP files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. Siemens Tecnomatix Plant Simulation is an industrial control device of Siemens, Germany. It uses discrete event simulation to analyze and optimize production volume, thereby improving the performance of manufacturing systems
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202307-0576",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "tecnomatix",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "2302.0002"
},
{
"model": "tecnomatix",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "2201.0008"
},
{
"model": "tecnomatix",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "2201"
},
{
"model": "tecnomatix",
"scope": "gte",
"trust": 1.0,
"vendor": "siemens",
"version": "2302"
},
{
"model": "tecnomatix",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "tecnomatix",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": "2302 that\u0027s all 2302.0002"
},
{
"model": "tecnomatix",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": "2201 that\u0027s all 2201.0008"
},
{
"model": "tecnomatix",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "tecnomatix plant simulation",
"scope": null,
"trust": 0.7,
"vendor": "siemens",
"version": null
},
{
"model": "tecnomatix plant simulation",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v2201\u003cv2201.0008"
},
{
"model": "tecnomatix plant simulation",
"scope": "eq",
"trust": 0.6,
"vendor": "siemens",
"version": "v2302\u003cv2302.0002"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-23-1574"
},
{
"db": "CNVD",
"id": "CNVD-2023-56536"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021702"
},
{
"db": "NVD",
"id": "CVE-2023-37374"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:tecnomatix:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "2302.0002",
"versionStartIncluding": "2302",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:tecnomatix:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "2201.0008",
"versionStartIncluding": "2201",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-37374"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Anonymous",
"sources": [
{
"db": "ZDI",
"id": "ZDI-23-1574"
}
],
"trust": 0.7
},
"cve": "CVE-2023-37374",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.2,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 3.9,
"id": "CNVD-2023-56536",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-37374",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "ZDI",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"id": "CVE-2023-37374",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 0.7,
"userInteraction": "REQUIRED",
"vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-37374",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "productcert@siemens.com",
"id": "CVE-2023-37374",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "ZDI",
"id": "CVE-2023-37374",
"trust": 0.7,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2023-56536",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202307-727",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-23-1574"
},
{
"db": "CNVD",
"id": "CNVD-2023-56536"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021702"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-727"
},
{
"db": "NVD",
"id": "CVE-2023-37374"
},
{
"db": "NVD",
"id": "CVE-2023-37374"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions \u003c V2201.0008), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0002). The affected application is vulnerable to stack-based buffer overflow while parsing specially crafted STP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21054). Siemens\u0027 tecnomatix Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Tecnomatix Plant Simulation. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of STP files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. Siemens Tecnomatix Plant Simulation is an industrial control device of Siemens, Germany. It uses discrete event simulation to analyze and optimize production volume, thereby improving the performance of manufacturing systems",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-37374"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021702"
},
{
"db": "ZDI",
"id": "ZDI-23-1574"
},
{
"db": "CNVD",
"id": "CNVD-2023-56536"
},
{
"db": "VULMON",
"id": "CVE-2023-37374"
}
],
"trust": 2.88
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-37374",
"trust": 4.6
},
{
"db": "SIEMENS",
"id": "SSA-764801",
"trust": 3.1
},
{
"db": "JVN",
"id": "JVNVU95292697",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021702",
"trust": 0.8
},
{
"db": "ZDI_CAN",
"id": "ZDI-CAN-21054",
"trust": 0.7
},
{
"db": "ZDI",
"id": "ZDI-23-1574",
"trust": 0.7
},
{
"db": "CNVD",
"id": "CNVD-2023-56536",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202307-727",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-37374",
"trust": 0.1
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-23-1574"
},
{
"db": "CNVD",
"id": "CNVD-2023-56536"
},
{
"db": "VULMON",
"id": "CVE-2023-37374"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021702"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-727"
},
{
"db": "NVD",
"id": "CVE-2023-37374"
}
]
},
"id": "VAR-202307-0576",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-56536"
}
],
"trust": 1.020371905
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-56536"
}
]
},
"last_update_date": "2024-01-21T20:33:54.011000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Siemens has issued an update to correct this vulnerability.",
"trust": 0.7,
"url": "https://cert-portal.siemens.com/productcert/html/ssa-764801.html"
},
{
"title": "Patch for Siemens Tecnomatix Plant Simulation Stack Buffer Overflow Vulnerability (CNVD-2023-56536)",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchinfo/show/443046"
},
{
"title": "Siemens Tecnomatix Plant Simulation Buffer error vulnerability fix",
"trust": 0.6,
"url": "http://123.124.177.30/web/xxk/bdxqbyid.tag?id=246650"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-23-1574"
},
{
"db": "CNVD",
"id": "CNVD-2023-56536"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-727"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021702"
},
{
"db": "NVD",
"id": "CVE-2023-37374"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-764801.pdf"
},
{
"trust": 1.3,
"url": "https://cert-portal.siemens.com/productcert/html/ssa-764801.html"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu95292697/"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-37374"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2023-37374/"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-23-1574"
},
{
"db": "CNVD",
"id": "CNVD-2023-56536"
},
{
"db": "VULMON",
"id": "CVE-2023-37374"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021702"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-727"
},
{
"db": "NVD",
"id": "CVE-2023-37374"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "ZDI",
"id": "ZDI-23-1574"
},
{
"db": "CNVD",
"id": "CNVD-2023-56536"
},
{
"db": "VULMON",
"id": "CVE-2023-37374"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021702"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-727"
},
{
"db": "NVD",
"id": "CVE-2023-37374"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-10-19T00:00:00",
"db": "ZDI",
"id": "ZDI-23-1574"
},
{
"date": "2023-07-17T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-56536"
},
{
"date": "2023-07-11T00:00:00",
"db": "VULMON",
"id": "CVE-2023-37374"
},
{
"date": "2024-01-19T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-021702"
},
{
"date": "2023-07-11T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202307-727"
},
{
"date": "2023-07-11T10:15:11.743000",
"db": "NVD",
"id": "CVE-2023-37374"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-10-19T00:00:00",
"db": "ZDI",
"id": "ZDI-23-1574"
},
{
"date": "2023-07-17T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-56536"
},
{
"date": "2023-07-11T00:00:00",
"db": "VULMON",
"id": "CVE-2023-37374"
},
{
"date": "2024-01-19T08:06:00",
"db": "JVNDB",
"id": "JVNDB-2023-021702"
},
{
"date": "2023-07-19T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202307-727"
},
{
"date": "2023-07-18T14:53:37.517000",
"db": "NVD",
"id": "CVE-2023-37374"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202307-727"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens\u0027 \u00a0tecnomatix\u00a0 Out-of-bounds write vulnerability in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021702"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202307-727"
}
],
"trust": 0.6
}
}
GHSA-QJ3V-HPPM-F4VW
Vulnerability from github – Published: 2023-07-11 12:30 – Updated: 2024-04-04 05:55A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0002). The affected application is vulnerable to stack-based buffer overflow while parsing specially crafted STP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21054)
{
"affected": [],
"aliases": [
"CVE-2023-37374"
],
"database_specific": {
"cwe_ids": [
"CWE-121",
"CWE-787"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2023-07-11T10:15:11Z",
"severity": "HIGH"
},
"details": "A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions \u003c V2201.0008), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0002). The affected application is vulnerable to stack-based buffer overflow while parsing specially crafted STP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21054)",
"id": "GHSA-qj3v-hppm-f4vw",
"modified": "2024-04-04T05:55:54Z",
"published": "2023-07-11T12:30:35Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2023-37374"
},
{
"type": "WEB",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-764801.pdf"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"type": "CVSS_V3"
}
]
}
GSD-2023-37374
Vulnerability from gsd - Updated: 2023-12-13 01:20{
"GSD": {
"alias": "CVE-2023-37374",
"id": "GSD-2023-37374"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2023-37374"
],
"details": "A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions \u003c V2201.0008), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0002). The affected application is vulnerable to stack-based buffer overflow while parsing specially crafted STP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21054)",
"id": "GSD-2023-37374",
"modified": "2023-12-13T01:20:24.739450Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2023-37374",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Tecnomatix Plant Simulation V2201",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V2201.0008"
}
]
}
},
{
"product_name": "Tecnomatix Plant Simulation V2302",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V2302.0002"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions \u003c V2201.0008), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0002). The affected application is vulnerable to stack-based buffer overflow while parsing specially crafted STP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21054)"
}
]
},
"impact": {
"cvss": [
{
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"cweId": "CWE-121",
"lang": "eng",
"value": "CWE-121: Stack-based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-764801.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-764801.pdf"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:tecnomatix:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "2302.0002",
"versionStartIncluding": "2302",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:tecnomatix:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "2201.0008",
"versionStartIncluding": "2201",
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2023-37374"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions \u003c V2201.0008), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0002). The affected application is vulnerable to stack-based buffer overflow while parsing specially crafted STP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21054)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-764801.pdf",
"refsource": "MISC",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-764801.pdf"
}
]
}
},
"impact": {
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
}
},
"lastModifiedDate": "2023-07-18T14:53Z",
"publishedDate": "2023-07-11T10:15Z"
}
}
}
SSA-764801
Vulnerability from csaf_siemens - Published: 2023-07-11 00:00 - Updated: 2023-09-12 00:00{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
"tlp": {
"label": "WHITE"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "Siemens Tecnomatix Plant Simulation contains multiple vulnerabilities that could be triggered when the application reads PAR, SPP, STP and PRT files.\nIf a user is tricked to open a malicious file using the affected application, this could lead to a crash, and potentially also to arbitrary code execution on the target host system.\n\nSiemens has released updates for the affected products and recommends to update to the latest versions.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-764801: File Parsing Vulnerabilities in Tecnomatix Plant Simulation - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-764801.html"
},
{
"category": "self",
"summary": "SSA-764801: File Parsing Vulnerabilities in Tecnomatix Plant Simulation - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-764801.json"
},
{
"category": "self",
"summary": "SSA-764801: File Parsing Vulnerabilities in Tecnomatix Plant Simulation - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-764801.pdf"
},
{
"category": "self",
"summary": "SSA-764801: File Parsing Vulnerabilities in Tecnomatix Plant Simulation - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-764801.txt"
}
],
"title": "SSA-764801: File Parsing Vulnerabilities in Tecnomatix Plant Simulation",
"tracking": {
"current_release_date": "2023-09-12T00:00:00Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-764801",
"initial_release_date": "2023-07-11T00:00:00Z",
"revision_history": [
{
"date": "2023-07-11T00:00:00Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2023-08-08T00:00:00Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Added additional vulnerabilities CVE-2023-38679, CVE-2023-38680, CVE-2023-38681 that are fixed in the same product versions (V2201.0008, V2302.0002)"
},
{
"date": "2023-09-12T00:00:00Z",
"legacy_version": "1.2",
"number": "3",
"summary": "Added CVE-2023-41846 fixed in the same product versions (V2201.0008, V2302.0002)"
}
],
"status": "interim",
"version": "3"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV2201.0008",
"product": {
"name": "Tecnomatix Plant Simulation V2201",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "Tecnomatix Plant Simulation V2201"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/\u003cV2302.0002",
"product": {
"name": "Tecnomatix Plant Simulation V2302",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "Tecnomatix Plant Simulation V2302"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2023-37246",
"cwe": {
"id": "CWE-122",
"name": "Heap-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted PRT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21109)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted PAR, SPP, STP or PRT files from unknown sources",
"product_ids": [
"1",
"2"
]
},
{
"category": "vendor_fix",
"details": "Update to V2201.0008 or later version",
"product_ids": [
"1"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V2302.0002 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2"
]
}
],
"title": "CVE-2023-37246"
},
{
"cve": "CVE-2023-37247",
"cwe": {
"id": "CWE-122",
"name": "Heap-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21138)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted PAR, SPP, STP or PRT files from unknown sources",
"product_ids": [
"1",
"2"
]
},
{
"category": "vendor_fix",
"details": "Update to V2201.0008 or later version",
"product_ids": [
"1"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V2302.0002 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2"
]
}
],
"title": "CVE-2023-37247"
},
{
"cve": "CVE-2023-37248",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted PAR file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21155)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted PAR, SPP, STP or PRT files from unknown sources",
"product_ids": [
"1",
"2"
]
},
{
"category": "vendor_fix",
"details": "Update to V2201.0008 or later version",
"product_ids": [
"1"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V2302.0002 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2"
]
}
],
"title": "CVE-2023-37248"
},
{
"cve": "CVE-2023-37374",
"cwe": {
"id": "CWE-121",
"name": "Stack-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "The affected application is vulnerable to stack-based buffer overflow while parsing specially crafted STP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21054)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted PAR, SPP, STP or PRT files from unknown sources",
"product_ids": [
"1",
"2"
]
},
{
"category": "vendor_fix",
"details": "Update to V2201.0008 or later version",
"product_ids": [
"1"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V2302.0002 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2"
]
}
],
"title": "CVE-2023-37374"
},
{
"cve": "CVE-2023-37375",
"cwe": {
"id": "CWE-121",
"name": "Stack-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "The affected application is vulnerable to stack-based buffer overflow while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21060)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted PAR, SPP, STP or PRT files from unknown sources",
"product_ids": [
"1",
"2"
]
},
{
"category": "vendor_fix",
"details": "Update to V2201.0008 or later version",
"product_ids": [
"1"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V2302.0002 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2"
]
}
],
"title": "CVE-2023-37375"
},
{
"cve": "CVE-2023-37376",
"cwe": {
"id": "CWE-843",
"name": "Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)"
},
"notes": [
{
"category": "summary",
"text": "The affected application contains a type confusion vulnerability while parsing STP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21051)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted PAR, SPP, STP or PRT files from unknown sources",
"product_ids": [
"1",
"2"
]
},
{
"category": "vendor_fix",
"details": "Update to V2201.0008 or later version",
"product_ids": [
"1"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V2302.0002 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2"
]
}
],
"title": "CVE-2023-37376"
},
{
"cve": "CVE-2023-38679",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21106)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted PAR, SPP, STP or PRT files from unknown sources",
"product_ids": [
"1",
"2"
]
},
{
"category": "vendor_fix",
"details": "Update to V2201.0008 or later version",
"product_ids": [
"1"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V2302.0002 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2"
]
}
],
"title": "CVE-2023-38679"
},
{
"cve": "CVE-2023-38680",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21132)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted PAR, SPP, STP or PRT files from unknown sources",
"product_ids": [
"1",
"2"
]
},
{
"category": "vendor_fix",
"details": "Update to V2201.0008 or later version",
"product_ids": [
"1"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V2302.0002 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2"
]
}
],
"title": "CVE-2023-38680"
},
{
"cve": "CVE-2023-38681",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"notes": [
{
"category": "summary",
"text": "The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted IGS file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21270)",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted PAR, SPP, STP or PRT files from unknown sources",
"product_ids": [
"1",
"2"
]
},
{
"category": "vendor_fix",
"details": "Update to V2201.0008 or later version",
"product_ids": [
"1"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V2302.0002 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2"
]
}
],
"title": "CVE-2023-38681"
},
{
"cve": "CVE-2023-41846",
"cwe": {
"id": "CWE-119",
"name": "Improper Restriction of Operations within the Bounds of a Memory Buffer"
},
"notes": [
{
"category": "summary",
"text": "The affected application is vulnerable to memory corruption while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Do not open untrusted PAR, SPP, STP or PRT files from unknown sources",
"product_ids": [
"1",
"2"
]
},
{
"category": "vendor_fix",
"details": "Update to V2201.0008 or later version",
"product_ids": [
"1"
],
"url": "https://support.sw.siemens.com/"
},
{
"category": "vendor_fix",
"details": "Update to V2302.0002 or later version",
"product_ids": [
"2"
],
"url": "https://support.sw.siemens.com/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2"
]
}
],
"title": "CVE-2023-41846"
}
]
}
FKIE_CVE-2023-37374
Vulnerability from fkie_nvd - Published: 2023-07-11 10:15 - Updated: 2024-11-21 08:117.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
| Vendor | Product | Version | |
|---|---|---|---|
| siemens | tecnomatix | * | |
| siemens | tecnomatix | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:tecnomatix:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0E8C9093-BD78-4ECE-9221-A889371B3839",
"versionEndExcluding": "2201.0008",
"versionStartIncluding": "2201",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:tecnomatix:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7103507-EE73-42FF-9DAB-37DD06467591",
"versionEndExcluding": "2302.0002",
"versionStartIncluding": "2302",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions \u003c V2201.0008), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0002). The affected application is vulnerable to stack-based buffer overflow while parsing specially crafted STP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21054)"
}
],
"id": "CVE-2023-37374",
"lastModified": "2024-11-21T08:11:36.350",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "productcert@siemens.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2023-07-11T10:15:11.743",
"references": [
{
"source": "productcert@siemens.com",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-764801.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-764801.pdf"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-121"
}
],
"source": "productcert@siemens.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CNVD-2023-56536
Vulnerability from cnvd - Published: 2023-07-17用户可参考如下供应商提供的安全公告获得补丁信息: https://cert-portal.siemens.com/productcert/html/ssa-764801.html
| Name | ['Siemens Tecnomatix Plant Simulation V2201 < V2201.0008', 'Siemens Tecnomatix Plant Simulation V2302 < V2302.0002'] |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2023-37374"
}
},
"description": "Siemens Tecnomatix Plant Simulation\u662f\u5fb7\u56fd\u897f\u95e8\u5b50\uff08Siemens\uff09\u516c\u53f8\u7684\u5de5\u63a7\u8bbe\u5907\uff0c\u5229\u7528\u79bb\u6563\u4e8b\u4ef6\u4eff\u771f\u8fdb\u884c\u751f\u4ea7\u91cf\u5206\u6790\u548c\u4f18\u5316\uff0c\u8fdb\u800c\u6539\u5584\u5236\u9020\u7cfb\u7edf\u6027\u80fd\u3002\n\nSiemens Tecnomatix Plant Simulation\u5b58\u5728\u5806\u6808\u7f13\u51b2\u533a\u6ea2\u51fa\u6f0f\u6d1e\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u5728\u5f53\u524d\u8fdb\u7a0b\u7684\u4e0a\u4e0b\u6587\u4e2d\u6267\u884c\u4ee3\u7801\u3002",
"formalWay": "\u7528\u6237\u53ef\u53c2\u8003\u5982\u4e0b\u4f9b\u5e94\u5546\u63d0\u4f9b\u7684\u5b89\u5168\u516c\u544a\u83b7\u5f97\u8865\u4e01\u4fe1\u606f\uff1a\r\nhttps://cert-portal.siemens.com/productcert/html/ssa-764801.html",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2023-56536",
"openTime": "2023-07-17",
"patchDescription": "Siemens Tecnomatix Plant Simulation\u662f\u5fb7\u56fd\u897f\u95e8\u5b50\uff08Siemens\uff09\u516c\u53f8\u7684\u5de5\u63a7\u8bbe\u5907\uff0c\u5229\u7528\u79bb\u6563\u4e8b\u4ef6\u4eff\u771f\u8fdb\u884c\u751f\u4ea7\u91cf\u5206\u6790\u548c\u4f18\u5316\uff0c\u8fdb\u800c\u6539\u5584\u5236\u9020\u7cfb\u7edf\u6027\u80fd\u3002\r\n\r\nSiemens Tecnomatix Plant Simulation\u5b58\u5728\u5806\u6808\u7f13\u51b2\u533a\u6ea2\u51fa\u6f0f\u6d1e\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u5728\u5f53\u524d\u8fdb\u7a0b\u7684\u4e0a\u4e0b\u6587\u4e2d\u6267\u884c\u4ee3\u7801\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002",
"patchName": "Siemens Tecnomatix Plant Simulation\u5806\u6808\u7f13\u51b2\u533a\u6ea2\u51fa\u6f0f\u6d1e\uff08CNVD-2023-56536\uff09\u7684\u8865\u4e01",
"products": {
"product": [
"Siemens Tecnomatix Plant Simulation V2201 \u003c V2201.0008",
"Siemens Tecnomatix Plant Simulation V2302 \u003c V2302.0002"
]
},
"referenceLink": "https://cert-portal.siemens.com/productcert/html/ssa-764801.html",
"serverity": "\u9ad8",
"submitTime": "2023-07-12",
"title": "Siemens Tecnomatix Plant Simulation\u5806\u6808\u7f13\u51b2\u533a\u6ea2\u51fa\u6f0f\u6d1e\uff08CNVD-2023-56536\uff09"
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.