cve-2023-46280
Vulnerability from cvelistv5
Published
2024-05-14 10:01
Modified
2024-11-12 12:49
Summary
A vulnerability has been identified in S7-PCT (All versions), Security Configuration Tool (SCT) (All versions), SIMATIC Automation Tool (All versions < V5.0 SP2), SIMATIC BATCH V9.1 (All versions < V9.1 SP2 Upd5), SIMATIC NET PC Software V16 (All versions < V16 Update 8), SIMATIC NET PC Software V17 (All versions), SIMATIC NET PC Software V18 (All versions < V18 SP1), SIMATIC NET PC Software V19 (All versions < V19 Update 2), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC PDM V9.2 (All versions < V9.2 SP2 Upd3), SIMATIC Route Control V9.1 (All versions < V9.1 SP2 Upd3), SIMATIC STEP 7 V5 (All versions), SIMATIC WinCC OA V3.17 (All versions), SIMATIC WinCC OA V3.18 (All versions < V3.18 P025), SIMATIC WinCC OA V3.19 (All versions < V3.19 P010), SIMATIC WinCC Runtime Advanced (All versions), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 6), SIMATIC WinCC Runtime Professional V17 (All versions < V17 Update 8), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC Unified PC Runtime V18 (All versions), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 17), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5), SINAMICS Startdrive (All versions < V19 SP1), SINEC NMS (All versions < V3.0), SINEC NMS (All versions < V3.0 SP1), SINUMERIK ONE virtual (All versions < V6.23), SINUMERIK PLC Programming Tool (All versions < V3.3.12), TIA Portal Cloud Connector (All versions < V2.0), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 4), Totally Integrated Automation Portal (TIA Portal) V19 (All versions < V19 Update 2). The affected applications contain an out of bounds read vulnerability. This could allow an attacker to cause a Blue Screen of Death (BSOD) crash of the underlying Windows kernel.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-46280",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-29T14:20:28.448026Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:22:08.819Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T20:37:40.324Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-962515.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "S7-PCT",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Security Configuration Tool (SCT)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Automation Tool",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.0 SP2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC BATCH V9.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.1 SP2 Upd5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC NET PC Software V16",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V16 Update 8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC NET PC Software V17",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC NET PC Software V18",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V18 SP1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC NET PC Software V19",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V19 Update 2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 V9.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.1 SP2 UC05",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PDM V9.2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.2 SP2 Upd3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Route Control V9.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.1 SP2 Upd3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC STEP 7 V5",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC OA V3.17",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC OA V3.18",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.18 P025",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC OA V3.19",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.19 P010",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC Runtime Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC Runtime Professional V16",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V16 Update 6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC Runtime Professional V17",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V17 Update 8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC Runtime Professional V18",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V18 Update 4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC Runtime Professional V19",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V19 Update 2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC Unified PC Runtime V18",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC V7.4",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC V7.5",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.5 SP2 Update 17",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC V8.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.0 Update 5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS Startdrive",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V19 SP1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINEC NMS",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINEC NMS",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0 SP1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINUMERIK ONE virtual",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.23",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINUMERIK PLC Programming Tool",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.3.12",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TIA Portal Cloud Connector",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Totally Integrated Automation Portal (TIA Portal) V15.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Totally Integrated Automation Portal (TIA Portal) V16",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Totally Integrated Automation Portal (TIA Portal) V17",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Totally Integrated Automation Portal (TIA Portal) V18",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V18 Update 4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Totally Integrated Automation Portal (TIA Portal) V19",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V19 Update 2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in S7-PCT (All versions), Security Configuration Tool (SCT) (All versions), SIMATIC Automation Tool (All versions \u003c V5.0 SP2), SIMATIC BATCH V9.1 (All versions \u003c V9.1 SP2 Upd5), SIMATIC NET PC Software V16 (All versions \u003c V16 Update 8), SIMATIC NET PC Software V17 (All versions), SIMATIC NET PC Software V18 (All versions \u003c V18 SP1), SIMATIC NET PC Software V19 (All versions \u003c V19 Update 2), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC PDM V9.2 (All versions \u003c V9.2 SP2 Upd3), SIMATIC Route Control V9.1 (All versions \u003c V9.1 SP2 Upd3), SIMATIC STEP 7 V5 (All versions), SIMATIC WinCC OA V3.17 (All versions), SIMATIC WinCC OA V3.18 (All versions \u003c V3.18 P025), SIMATIC WinCC OA V3.19 (All versions \u003c V3.19 P010), SIMATIC WinCC Runtime Advanced (All versions), SIMATIC WinCC Runtime Professional V16 (All versions \u003c V16 Update 6), SIMATIC WinCC Runtime Professional V17 (All versions \u003c V17 Update 8), SIMATIC WinCC Runtime Professional V18 (All versions \u003c V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions \u003c V19 Update 2), SIMATIC WinCC Unified PC Runtime V18 (All versions), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 17), SIMATIC WinCC V8.0 (All versions \u003c V8.0 Update 5), SINAMICS Startdrive (All versions \u003c V19 SP1), SINEC NMS (All versions \u003c V3.0), SINEC NMS (All versions \u003c V3.0 SP1), SINUMERIK ONE virtual (All versions \u003c V6.23), SINUMERIK PLC Programming Tool (All versions \u003c V3.3.12), TIA Portal Cloud Connector (All versions \u003c V2.0), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 4), Totally Integrated Automation Portal (TIA Portal) V19 (All versions \u003c V19 Update 2). The affected applications contain an out of bounds read vulnerability. This could allow an attacker to cause a Blue Screen of Death (BSOD) crash of the underlying Windows kernel."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-12T12:49:24.469Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-962515.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-784301.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-331112.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-46280",
    "datePublished": "2024-05-14T10:01:52.069Z",
    "dateReserved": "2023-10-20T08:02:52.794Z",
    "dateUpdated": "2024-11-12T12:49:24.469Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2023-46280\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2024-05-14T16:15:40.800\",\"lastModified\":\"2024-11-12T13:15:05.960\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in S7-PCT (All versions), Security Configuration Tool (SCT) (All versions), SIMATIC Automation Tool (All versions \u003c V5.0 SP2), SIMATIC BATCH V9.1 (All versions \u003c V9.1 SP2 Upd5), SIMATIC NET PC Software V16 (All versions \u003c V16 Update 8), SIMATIC NET PC Software V17 (All versions), SIMATIC NET PC Software V18 (All versions \u003c V18 SP1), SIMATIC NET PC Software V19 (All versions \u003c V19 Update 2), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC PDM V9.2 (All versions \u003c V9.2 SP2 Upd3), SIMATIC Route Control V9.1 (All versions \u003c V9.1 SP2 Upd3), SIMATIC STEP 7 V5 (All versions), SIMATIC WinCC OA V3.17 (All versions), SIMATIC WinCC OA V3.18 (All versions \u003c V3.18 P025), SIMATIC WinCC OA V3.19 (All versions \u003c V3.19 P010), SIMATIC WinCC Runtime Advanced (All versions), SIMATIC WinCC Runtime Professional V16 (All versions \u003c V16 Update 6), SIMATIC WinCC Runtime Professional V17 (All versions \u003c V17 Update 8), SIMATIC WinCC Runtime Professional V18 (All versions \u003c V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions \u003c V19 Update 2), SIMATIC WinCC Unified PC Runtime V18 (All versions), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 17), SIMATIC WinCC V8.0 (All versions \u003c V8.0 Update 5), SINAMICS Startdrive (All versions \u003c V19 SP1), SINEC NMS (All versions \u003c V3.0), SINEC NMS (All versions \u003c V3.0 SP1), SINUMERIK ONE virtual (All versions \u003c V6.23), SINUMERIK PLC Programming Tool (All versions \u003c V3.3.12), TIA Portal Cloud Connector (All versions \u003c V2.0), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 4), Totally Integrated Automation Portal (TIA Portal) V19 (All versions \u003c V19 Update 2). The affected applications contain an out of bounds read vulnerability. This could allow an attacker to cause a Blue Screen of Death (BSOD) crash of the underlying Windows kernel.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en: S7-PCT (todas las versiones),\\nSecurity Configuration Tool (SCT) (todas las versiones),\\nSIMATIC Automation Tool (todas las versiones),\\nSIMATIC BATCH V9.1 (todas las versiones),\\nSIMATIC NET PC Software (todas las versiones),\\nSIMATIC PCS 7 V9.1 (todas las versiones),\\nSIMATIC PDM V9.2 (todas las versiones),\\nSIMATIC Route Control V9.1 (todas las versiones),\\nSIMATIC STEP 7 V5 (todas las versiones),\\nSIMATIC WinCC OA V3.17 ( Todas las versiones),\\nSIMATIC WinCC OA V3.18 (todas las versiones \u0026lt; V3.18 P025),\\nSIMATIC WinCC OA V3.19 (todas las versiones \u0026lt; V3.19 P010),\\nSIMATIC WinCC Runtime Advanced (todas las versiones),\\nSIMATIC WinCC Runtime Professional V16 (Todas las versiones),\\nSIMATIC WinCC Runtime Professional V17 (todas las versiones),\\nSIMATIC WinCC Runtime Professional V18 (todas las versiones),\\nSIMATIC WinCC Runtime Professional V19 (todas las versiones),\\nSIMATIC WinCC Unified PC Runtime (todas las versiones),\\nSIMATIC WinCC V7.4 (Todas las versiones),\\nSIMATIC WinCC V7.5 (Todas las versiones),\\nSIMATIC WinCC V8.0 (Todas las versiones),\\nSINAMICS Startdrive (Todas las versiones \u0026lt; V19 SP1),\\nSINUMERIK ONE virtual (Todas las versiones \u0026lt; V6.23),\\nProgramaci\u00f3n de PLC SINUMERIK Herramienta (todas las versiones),\\nTIA Portal Cloud Connector (todas las versiones \u0026lt; V2.0),\\nTotally Integrated Automation Portal (TIA Portal) V15.1 (todas las versiones),\\nTotally Integrated Automation Portal (TIA Portal) V16 (todas las versiones),\\nTotally Portal de automatizaci\u00f3n integrado (TIA Portal) V17 (todas las versiones),\\nPortal de automatizaci\u00f3n totalmente integrado (Portal TIA) V18 (todas las versiones),\\nPortal de automatizaci\u00f3n totalmente integrado (TIA Portal) V19 (todas las versiones \"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"vulnerableSystemConfidentiality\":\"NONE\",\"vulnerableSystemIntegrity\":\"NONE\",\"vulnerableSystemAvailability\":\"HIGH\",\"subsequentSystemConfidentiality\":\"NONE\",\"subsequentSystemIntegrity\":\"NONE\",\"subsequentSystemAvailability\":\"HIGH\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirements\":\"NOT_DEFINED\",\"integrityRequirements\":\"NOT_DEFINED\",\"availabilityRequirements\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnerableSystemConfidentiality\":\"NOT_DEFINED\",\"modifiedVulnerableSystemIntegrity\":\"NOT_DEFINED\",\"modifiedVulnerableSystemAvailability\":\"NOT_DEFINED\",\"modifiedSubsequentSystemConfidentiality\":\"NOT_DEFINED\",\"modifiedSubsequentSystemIntegrity\":\"NOT_DEFINED\",\"modifiedSubsequentSystemAvailability\":\"NOT_DEFINED\",\"safety\":\"NOT_DEFINED\",\"automatable\":\"NOT_DEFINED\",\"recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\",\"baseScore\":8.2,\"baseSeverity\":\"HIGH\"}}],\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:N/I:N/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":2.0,\"impactScore\":4.0}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-125\"}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-331112.html\",\"source\":\"productcert@siemens.com\"},{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-784301.html\",\"source\":\"productcert@siemens.com\"},{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-962515.html\",\"source\":\"productcert@siemens.com\"}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.