cve-2024-27944
Vulnerability from cvelistv5
Published
2024-05-14 10:02
Modified
2024-08-02 00:41
Summary
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.5). The affected systems allow a privileged user to upload firmware files to the root installation directory of the system. By replacing specific files, an attacker could tamper specific files or even achieve remote code execution.
Impacted products
Vendor Product Version
Siemens RUGGEDCOM CROSSBOW Version: 0   < V5.5
Create a notification for this product.
Show details on NVD website


{
   containers: {
      adp: [
         {
            affected: [
               {
                  cpes: [
                     "cpe:2.3:a:siemens:ruggedcom_crossbow:-:*:*:*:*:*:*:*",
                  ],
                  defaultStatus: "unknown",
                  product: "ruggedcom_crossbow",
                  vendor: "siemens",
                  versions: [
                     {
                        lessThan: "5.5",
                        status: "affected",
                        version: "-",
                        versionType: "custom",
                     },
                  ],
               },
            ],
            metrics: [
               {
                  other: {
                     content: {
                        id: "CVE-2024-27944",
                        options: [
                           {
                              Exploitation: "none",
                           },
                           {
                              Automatable: "no",
                           },
                           {
                              "Technical Impact": "total",
                           },
                        ],
                        role: "CISA Coordinator",
                        timestamp: "2024-05-14T13:11:51.980476Z",
                        version: "2.0.3",
                     },
                     type: "ssvc",
                  },
               },
            ],
            providerMetadata: {
               dateUpdated: "2024-06-04T17:47:03.078Z",
               orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
               shortName: "CISA-ADP",
            },
            title: "CISA ADP Vulnrichment",
         },
         {
            providerMetadata: {
               dateUpdated: "2024-08-02T00:41:55.820Z",
               orgId: "af854a3a-2127-422b-91ae-364da2661108",
               shortName: "CVE",
            },
            references: [
               {
                  tags: [
                     "x_transferred",
                  ],
                  url: "https://cert-portal.siemens.com/productcert/html/ssa-916916.html",
               },
            ],
            title: "CVE Program Container",
         },
      ],
      cna: {
         affected: [
            {
               defaultStatus: "unknown",
               product: "RUGGEDCOM CROSSBOW",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V5.5",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
         ],
         descriptions: [
            {
               lang: "en",
               value: "A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.5). The affected systems allow a privileged user to upload firmware files to the root installation directory of the system. By replacing specific files, an attacker could tamper specific files or even achieve remote code execution.",
            },
         ],
         metrics: [
            {
               cvssV3_1: {
                  baseScore: 7.2,
                  baseSeverity: "HIGH",
                  vectorString: "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
                  version: "3.1",
               },
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     cweId: "CWE-73",
                     description: "CWE-73: External Control of File Name or Path",
                     lang: "en",
                     type: "CWE",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2024-05-15T07:24:02.656Z",
            orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            shortName: "siemens",
         },
         references: [
            {
               url: "https://cert-portal.siemens.com/productcert/html/ssa-916916.html",
            },
         ],
      },
   },
   cveMetadata: {
      assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
      assignerShortName: "siemens",
      cveId: "CVE-2024-27944",
      datePublished: "2024-05-14T10:02:13.176Z",
      dateReserved: "2024-02-28T16:38:00.193Z",
      dateUpdated: "2024-08-02T00:41:55.820Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
   "vulnerability-lookup:meta": {
      fkie_nvd: {
         descriptions: "[{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.5). The affected systems allow a privileged user to upload firmware files to the root installation directory of the system. By replacing specific files, an attacker could tamper specific files or even achieve remote code execution.\"}, {\"lang\": \"es\", \"value\": \"Se ha identificado una vulnerabilidad en RUGGEDCOM CROSSBOW (Todas las versiones &lt; V5.5). Los sistemas afectados permiten a un usuario privilegiado cargar archivos de firmware en el directorio de instalaci\\u00f3n ra\\u00edz del sistema. Al reemplazar archivos espec\\u00edficos, un atacante podr\\u00eda alterar archivos espec\\u00edficos o incluso lograr la ejecuci\\u00f3n remota de c\\u00f3digo.\"}]",
         id: "CVE-2024-27944",
         lastModified: "2024-11-21T09:05:28.360",
         metrics: "{\"cvssMetricV31\": [{\"source\": \"productcert@siemens.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 7.2, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.2, \"impactScore\": 5.9}]}",
         published: "2024-05-14T16:16:31.260",
         references: "[{\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-916916.html\", \"source\": \"productcert@siemens.com\"}, {\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-916916.html\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}]",
         sourceIdentifier: "productcert@siemens.com",
         vulnStatus: "Awaiting Analysis",
         weaknesses: "[{\"source\": \"productcert@siemens.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-73\"}]}]",
      },
      nvd: "{\"cve\":{\"id\":\"CVE-2024-27944\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2024-05-14T16:16:31.260\",\"lastModified\":\"2025-02-06T18:15:10.320\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.5). The affected systems allow a privileged user to upload firmware files to the root installation directory of the system. By replacing specific files, an attacker could tamper specific files or even achieve remote code execution.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en RUGGEDCOM CROSSBOW (Todas las versiones &lt; V5.5). Los sistemas afectados permiten a un usuario privilegiado cargar archivos de firmware en el directorio de instalación raíz del sistema. Al reemplazar archivos específicos, un atacante podría alterar archivos específicos o incluso lograr la ejecución remota de código.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-73\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-434\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:ruggedcom_crossbow:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"5.5\",\"matchCriteriaId\":\"5984B129-3702-4DA7-AEA9-4B538CFE5E40\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-916916.html\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-916916.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}",
      vulnrichment: {
         containers: "{\"cna\": {\"providerMetadata\": {\"orgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"shortName\": \"siemens\", \"dateUpdated\": \"2024-05-15T07:24:02.656Z\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.5). The affected systems allow a privileged user to upload firmware files to the root installation directory of the system. By replacing specific files, an attacker could tamper specific files or even achieve remote code execution.\"}], \"affected\": [{\"vendor\": \"Siemens\", \"product\": \"RUGGEDCOM CROSSBOW\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V5.5\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}], \"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C\", \"baseScore\": 7.2, \"baseSeverity\": \"HIGH\"}}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"cweId\": \"CWE-73\", \"description\": \"CWE-73: External Control of File Name or Path\", \"type\": \"CWE\"}]}], \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-916916.html\"}]}, \"adp\": [{\"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-27944\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-05-14T13:11:51.980476Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:a:siemens:ruggedcom_crossbow:-:*:*:*:*:*:*:*\"], \"vendor\": \"siemens\", \"product\": \"ruggedcom_crossbow\", \"versions\": [{\"status\": \"affected\", \"version\": \"-\", \"lessThan\": \"5.5\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-05-14T13:11:50.632Z\"}, \"title\": \"CISA ADP Vulnrichment\"}]}",
         cveMetadata: "{\"cveId\": \"CVE-2024-27944\", \"assignerOrgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"state\": \"PUBLISHED\", \"assignerShortName\": \"siemens\", \"dateReserved\": \"2024-02-28T16:38:00.193Z\", \"datePublished\": \"2024-05-14T10:02:13.176Z\", \"dateUpdated\": \"2024-06-04T17:47:03.078Z\"}",
         dataType: "CVE_RECORD",
         dataVersion: "5.1",
      },
   },
}


Log in or create an account to share your comment.

Security Advisory comment format.

This schema specifies the format of a comment related to a security advisory.

UUIDv4 of the comment
UUIDv4 of the Vulnerability-Lookup instance
When the comment was created originally
When the comment was last updated
Title of the comment
Description of the comment
The identifier of the vulnerability (CVE ID, GHSA-ID, PYSEC ID, etc.).



Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.