CVE-2024-30891 (GCVE-0-2024-30891)

Vulnerability from cvelistv5 – Published: 2024-04-05 00:00 – Updated: 2024-08-19 19:16
VLAI Shadowserver Previdian
Summary
A command injection vulnerability exists in /goform/exeCommand in Tenda AC18 v15.03.05.05, which allows attackers to construct cmdinput parameters for arbitrary command execution.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-04-05 15:48 UTC
CWE
  • n/a
  • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Impacted products
Vendor Product Version CPE status
tenda ac18_firmware Affected: 15.03.05.05
    cpe:2.3:o:tenda:ac18_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Shadowserver
Known Exploited Vulnerability - GCVE BCP-07 Compliant

Vulnerability ID: CVE-2024-30891

Status: Confirmed

Status Updated: 2026-03-20 00:00 UTC

Exploited: Yes


Characteristics
Severity: 88.0

Timestamps
First Seen: 2025-12-21
Asserted: 2025-12-21
Last Seen: 2026-03-20

Scope
Asset Exposure: ['internet-facing']
Notes: Affected: Tenda / Tenda AC18 | Class: router | Severity: High (CVSS 8.8) | IoT: yes | In CISA KEV: no | Honeypot connections on 2026-03-20: 10

Evidence

Type: Honeypot

Signal: In The Wild Attempts

Confidence: 70%

Source: shadowserver


Details
1D 1
Iot yes
Feed Shadowserver Foundation honeypot/exploited-vulnerabilities
Type http-scan
Class router
7D Avg 0
Vendor Tenda
30D Avg 0
90D Avg 0
Product Tenda AC18
Cisa Kev no
Connections 10
Observation Date 2026-03-20
Vulnerability Class CVSS
Vulnerability Score 8.8
Vulnerability Severity High

References

Created: 2026-06-30 09:39 UTC | Updated: 2026-06-30 10:01 UTC
Previdian
Known Exploited Vulnerability - GCVE BCP-07 Compliant

Vulnerability ID: CVE-2024-30891

Status: Confirmed

Status Updated: 2024-04-05 00:00 UTC

Exploited: Yes


Timestamps
First Seen: 2024-04-05
Asserted: 2024-04-05

Scope
Notes: KEVIntel entry: A command injection vulnerability exists in /goform/exeCommand in Tenda AC18 v15.03.05.05, which allows attackers to construct cmdinput parameters... | Affected: n/a / n/a | Used in malware: unknown | Not yet in CISA KEV: True

Evidence

Type: Public Report

Signal: Successful Exploitation

Confidence: 70%

Source: kevintel


Details
Feed KEVIntel (kevintel.com)
Title A command injection vulnerability exists in /goform/exeCommand in Tenda AC18 v15.03.05.05, which allows attackers to construct cmdinput parameters...
Vendor n/a
Product n/a
Added Date 2024-04-05T00:00:00.000Z
Cvss Score None
Epss Score None
Cvss Severity None
Epss Percentile None
Used In Malware unknown
Ahead Of Cisa Kev None
Not Yet In Cisa Kev True

References

Created: 2026-06-23 14:06 UTC | Updated: 2026-07-10 06:14 UTC
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T01:39:00.919Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/Lantern-r/IoT-vuln/blob/main/Tenda/AC18/formexeCommand.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ac18_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ac18_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "15.03.05.05"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-30891",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-05T15:48:07.633634Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-77",
                "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-19T19:16:28.344Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A command injection vulnerability exists in /goform/exeCommand in Tenda AC18 v15.03.05.05, which allows attackers to construct cmdinput parameters for arbitrary command execution."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-05T07:17:46.091Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/Lantern-r/IoT-vuln/blob/main/Tenda/AC18/formexeCommand.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-30891",
    "datePublished": "2024-04-05T00:00:00.000Z",
    "dateReserved": "2024-03-27T00:00:00.000Z",
    "dateUpdated": "2024-08-19T19:16:28.344Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2024-30891",
      "date": "2026-09-30",
      "epss": "0.01896",
      "percentile": "0.78862"
    },
    "fkie_nvd": {
      "descriptions": [
        {
          "lang": "en",
          "value": "A command injection vulnerability exists in /goform/exeCommand in Tenda AC18 v15.03.05.05, which allows attackers to construct cmdinput parameters for arbitrary command execution."
        },
        {
          "lang": "es",
          "value": "Existe una vulnerabilidad de inyecci\u00f3n de comandos en /goform/exeCommand en Tenda AC18 v15.03.05.05, que permite a los atacantes construir par\u00e1metros cmdinput para la ejecuci\u00f3n de comandos arbitrarios."
        }
      ],
      "id": "CVE-2024-30891",
      "lastModified": "2024-11-21T09:12:33.533",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "type": "Secondary"
          }
        ]
      },
      "published": "2024-04-05T08:15:07.800",
      "references": [
        {
          "source": "cve@mitre.org",
          "url": "https://github.com/Lantern-r/IoT-vuln/blob/main/Tenda/AC18/formexeCommand.md"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://github.com/Lantern-r/IoT-vuln/blob/main/Tenda/AC18/formexeCommand.md"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Awaiting Analysis",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-77"
            }
          ],
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "type": "Secondary"
        }
      ]
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "product": "n/a",
                "vendor": "n/a",
                "versions": [
                  {
                    "status": "affected",
                    "version": "n/a"
                  }
                ]
              }
            ],
            "source": "cve@mitre.org"
          },
          {
            "affectedData": [
              {
                "cpes": [
                  "cpe:2.3:o:tenda:ac18_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ac18_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "15.03.05.05"
                  }
                ]
              }
            ],
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
          }
        ],
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:tenda:ac18_firmware:15.03.05.05:*:*:*:*:*:*:*",
                    "matchCriteriaId": "4D5CB727-FC6B-4212-A61E-2888A0DADFB0",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "CF9F8AF9-F921-4348-922B-EE5E6037E7AC",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "A command injection vulnerability exists in /goform/exeCommand in Tenda AC18 v15.03.05.05, which allows attackers to construct cmdinput parameters for arbitrary command execution."
          },
          {
            "lang": "es",
            "value": "Existe una vulnerabilidad de inyecci\u00f3n de comandos en /goform/exeCommand en Tenda AC18 v15.03.05.05, que permite a los atacantes construir par\u00e1metros cmdinput para la ejecuci\u00f3n de comandos arbitrarios."
          }
        ],
        "id": "CVE-2024-30891",
        "lastModified": "2026-06-17T07:27:29.473",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 2.8,
              "impactScore": 5.9,
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2024-30891",
                "options": [
                  {
                    "exploitation": "poc"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-05T15:48:07.633634Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2024-04-05T08:15:07.800",
        "references": [
          {
            "source": "cve@mitre.org",
            "tags": [
              "Exploit",
              "Third Party Advisory"
            ],
            "url": "https://github.com/Lantern-r/IoT-vuln/blob/main/Tenda/AC18/formexeCommand.md"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Exploit",
              "Third Party Advisory"
            ],
            "url": "https://github.com/Lantern-r/IoT-vuln/blob/main/Tenda/AC18/formexeCommand.md"
          }
        ],
        "sourceIdentifier": "cve@mitre.org",
        "vulnStatus": "Analyzed",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-77"
              }
            ],
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "type": "Secondary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2026-03-27T10:04:48+00:00",
      "cve": "CVE-2024-30891",
      "id": "CVE-2024-30891",
      "initial_release_date": "2024-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "CVE-2024-30891",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2024/cve-2024-30891.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T01:39:00.919Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://github.com/Lantern-r/IoT-vuln/blob/main/Tenda/AC18/formexeCommand.md"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:tenda:ac18_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "ac18_firmware",
                "vendor": "tenda",
                "versions": [
                  {
                    "status": "affected",
                    "version": "15.03.05.05"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "ADJACENT_NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 8.8,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-30891",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-04-05T15:48:07.633634Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-77",
                    "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-19T19:15:34.714Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A command injection vulnerability exists in /goform/exeCommand in Tenda AC18 v15.03.05.05, which allows attackers to construct cmdinput parameters for arbitrary command execution."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-04-05T07:17:46.091526",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/Lantern-r/IoT-vuln/blob/main/Tenda/AC18/formexeCommand.md"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2024-30891",
        "datePublished": "2024-04-05T00:00:00",
        "dateReserved": "2024-03-27T00:00:00",
        "dateUpdated": "2024-08-19T19:16:28.344Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…