Action not permitted
Modal body text goes here.
Modal Title
Modal Body
cve-2024-32635
Vulnerability from cvelistv5
Published
2024-05-14 10:02
Modified
2024-08-13 07:54
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.3 (High) - CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
7.3 (High) - CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
EPSS score ?
Summary
A vulnerability has been identified in JT2Go (All versions < V2312.0005), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.10), Teamcenter Visualization V2312 (All versions < V2312.0005). The affected applications contain an out of bounds read past the unmapped memory region while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | JT2Go |
Version: 0 < V2312.0005 |
||||||||||||
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:a:siemens:parasolid:35.1:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "parasolid", "vendor": "siemens", "versions": [ { "lessThan": "35.1.256", "status": "affected", "version": "35.1", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:parasolid:36.0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "parasolid", "vendor": "siemens", "versions": [ { "lessThan": "36.0.208", "status": "affected", "version": "36.0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:parasolid:36.1:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "parasolid", "vendor": "siemens", "versions": [ { "lessThan": "36.1.173", "status": "affected", "version": "36.1", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-32635", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-05-14T13:37:49.970409Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-06T17:27:51.096Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-02T02:13:40.417Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-046364.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "JT2Go", "vendor": "Siemens", "versions": [ { "lessThan": "V2312.0005", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V14.2", "vendor": "Siemens", "versions": [ { "lessThan": "V14.2.0.12", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V14.3", "vendor": "Siemens", "versions": [ { "lessThan": "V14.3.0.10", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Teamcenter Visualization V2312", "vendor": "Siemens", "versions": [ { "lessThan": "V2312.0005", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in JT2Go (All versions \u003c V2312.0005), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.12), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.10), Teamcenter Visualization V2312 (All versions \u003c V2312.0005). The affected applications contain an out of bounds read past the unmapped memory region while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 7.3, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-125", "description": "CWE-125: Out-of-bounds Read", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-08-13T07:54:05.071Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-046364.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-856475.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2024-32635", "datePublished": "2024-05-14T10:02:42.291Z", "dateReserved": "2024-04-16T10:52:15.707Z", "dateUpdated": "2024-08-13T07:54:05.071Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2024-32635\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2024-05-14T16:17:04.387\",\"lastModified\":\"2024-11-21T09:15:22.217\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in JT2Go (All versions \u003c V2312.0005), Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.12), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.10), Teamcenter Visualization V2312 (All versions \u003c V2312.0005). The affected applications contain an out of bounds read past the unmapped memory region while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en Parasolid V35.1 (Todas las versiones \u0026lt; V35.1.256), Parasolid V36.0 (Todas las versiones \u0026lt; V36.0.208), Parasolid V36.1 (Todas las versiones \u0026lt; V36.1.173). Las aplicaciones afectadas contienen una lectura fuera de los l\u00edmites m\u00e1s all\u00e1 de la regi\u00f3n de memoria no asignada mientras analizan archivos X_T especialmente manipulados. Esto podr\u00eda permitir a un atacante ejecutar c\u00f3digo en el contexto del proceso actual.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":7.3,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"HIGH\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"PASSIVE\",\"vulnerableSystemConfidentiality\":\"HIGH\",\"vulnerableSystemIntegrity\":\"HIGH\",\"vulnerableSystemAvailability\":\"HIGH\",\"subsequentSystemConfidentiality\":\"NONE\",\"subsequentSystemIntegrity\":\"NONE\",\"subsequentSystemAvailability\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirements\":\"NOT_DEFINED\",\"integrityRequirements\":\"NOT_DEFINED\",\"availabilityRequirements\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnerableSystemConfidentiality\":\"NOT_DEFINED\",\"modifiedVulnerableSystemIntegrity\":\"NOT_DEFINED\",\"modifiedVulnerableSystemAvailability\":\"NOT_DEFINED\",\"modifiedSubsequentSystemConfidentiality\":\"NOT_DEFINED\",\"modifiedSubsequentSystemIntegrity\":\"NOT_DEFINED\",\"modifiedSubsequentSystemAvailability\":\"NOT_DEFINED\",\"safety\":\"NOT_DEFINED\",\"automatable\":\"NOT_DEFINED\",\"recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-125\"}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-046364.html\",\"source\":\"productcert@siemens.com\"},{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-856475.html\",\"source\":\"productcert@siemens.com\"},{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-046364.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}" } }
SSA-046364
Vulnerability from csaf_siemens
Published
2024-05-14 00:00
Modified
2024-05-14 00:00
Summary
SSA-046364: X_T File Parsing Vulnerabilities in Parasolid
Notes
Summary
Parasolid is affected by out of bounds read and null pointer dereference vulnerabilities that could be triggered when the application reads files in X_T format. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the out of bounds read vulnerabilities to perform remote code execution in the context of the current process or denial of service condition in the application.
Siemens has released new versions for the affected products and recommends to update to the latest versions.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download:
https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.
{ "document": { "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)", "tlp": { "label": "WHITE" } }, "lang": "en", "notes": [ { "category": "summary", "text": "Parasolid is affected by out of bounds read and null pointer dereference vulnerabilities that could be triggered when the application reads files in X_T format. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the out of bounds read vulnerabilities to perform remote code execution in the context of the current process or denial of service condition in the application. \n\nSiemens has released new versions for the affected products and recommends to update to the latest versions.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" } ], "publisher": { "category": "vendor", "contact_details": "productcert@siemens.com", "name": "Siemens ProductCERT", "namespace": "https://www.siemens.com" }, "references": [ { "category": "self", "summary": "SSA-046364: X_T File Parsing Vulnerabilities in Parasolid - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-046364.html" }, { "category": "self", "summary": "SSA-046364: X_T File Parsing Vulnerabilities in Parasolid - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-046364.json" }, { "category": "self", "summary": "SSA-046364: X_T File Parsing Vulnerabilities in Parasolid - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-046364.pdf" }, { "category": "self", "summary": "SSA-046364: X_T File Parsing Vulnerabilities in Parasolid - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-046364.txt" } ], "title": "SSA-046364: X_T File Parsing Vulnerabilities in Parasolid", "tracking": { "current_release_date": "2024-05-14T00:00:00Z", "generator": { "engine": { "name": "Siemens ProductCERT CSAF Generator", "version": "1" } }, "id": "SSA-046364", "initial_release_date": "2024-05-14T00:00:00Z", "revision_history": [ { "date": "2024-05-14T00:00:00Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "interim", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV35.1.256", "product": { "name": "Parasolid V35.1", "product_id": "1" } } ], "category": "product_name", "name": "Parasolid V35.1" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV36.0.208", "product": { "name": "Parasolid V36.0", "product_id": "2" } } ], "category": "product_name", "name": "Parasolid V36.0" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV36.1.173", "product": { "name": "Parasolid V36.1", "product_id": "3" } } ], "category": "product_name", "name": "Parasolid V36.1" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2024-32635", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the unmapped memory region while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_T files in Parasolid", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update to V35.1.256 or later version", "product_ids": [ "1" ] }, { "category": "vendor_fix", "details": "Update to V36.0.208 or later version", "product_ids": [ "2" ] }, { "category": "vendor_fix", "details": "Update to V36.1.173 or later version", "product_ids": [ "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2024-32635" }, { "cve": "CVE-2024-32636", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_T files in Parasolid", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update to V35.1.256 or later version", "product_ids": [ "1" ] }, { "category": "vendor_fix", "details": "Update to V36.0.208 or later version", "product_ids": [ "2" ] }, { "category": "vendor_fix", "details": "Update to V36.1.173 or later version", "product_ids": [ "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2024-32636" }, { "cve": "CVE-2024-32637", "cwe": { "id": "CWE-476", "name": "NULL Pointer Dereference" }, "notes": [ { "category": "summary", "text": "The affected applications contain a null pointer dereference vulnerability while parsing specially crafted X_T files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_T files in Parasolid", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update to V35.1.256 or later version", "product_ids": [ "1" ] }, { "category": "vendor_fix", "details": "Update to V36.0.208 or later version", "product_ids": [ "2" ] }, { "category": "vendor_fix", "details": "Update to V36.1.173 or later version", "product_ids": [ "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2024-32637" } ] }
ssa-046364
Vulnerability from csaf_siemens
Published
2024-05-14 00:00
Modified
2024-05-14 00:00
Summary
SSA-046364: X_T File Parsing Vulnerabilities in Parasolid
Notes
Summary
Parasolid is affected by out of bounds read and null pointer dereference vulnerabilities that could be triggered when the application reads files in X_T format. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the out of bounds read vulnerabilities to perform remote code execution in the context of the current process or denial of service condition in the application.
Siemens has released new versions for the affected products and recommends to update to the latest versions.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download:
https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.
{ "document": { "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)", "tlp": { "label": "WHITE" } }, "lang": "en", "notes": [ { "category": "summary", "text": "Parasolid is affected by out of bounds read and null pointer dereference vulnerabilities that could be triggered when the application reads files in X_T format. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the out of bounds read vulnerabilities to perform remote code execution in the context of the current process or denial of service condition in the application. \n\nSiemens has released new versions for the affected products and recommends to update to the latest versions.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" } ], "publisher": { "category": "vendor", "contact_details": "productcert@siemens.com", "name": "Siemens ProductCERT", "namespace": "https://www.siemens.com" }, "references": [ { "category": "self", "summary": "SSA-046364: X_T File Parsing Vulnerabilities in Parasolid - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-046364.html" }, { "category": "self", "summary": "SSA-046364: X_T File Parsing Vulnerabilities in Parasolid - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-046364.json" }, { "category": "self", "summary": "SSA-046364: X_T File Parsing Vulnerabilities in Parasolid - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-046364.pdf" }, { "category": "self", "summary": "SSA-046364: X_T File Parsing Vulnerabilities in Parasolid - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-046364.txt" } ], "title": "SSA-046364: X_T File Parsing Vulnerabilities in Parasolid", "tracking": { "current_release_date": "2024-05-14T00:00:00Z", "generator": { "engine": { "name": "Siemens ProductCERT CSAF Generator", "version": "1" } }, "id": "SSA-046364", "initial_release_date": "2024-05-14T00:00:00Z", "revision_history": [ { "date": "2024-05-14T00:00:00Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "interim", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV35.1.256", "product": { "name": "Parasolid V35.1", "product_id": "1" } } ], "category": "product_name", "name": "Parasolid V35.1" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV36.0.208", "product": { "name": "Parasolid V36.0", "product_id": "2" } } ], "category": "product_name", "name": "Parasolid V36.0" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV36.1.173", "product": { "name": "Parasolid V36.1", "product_id": "3" } } ], "category": "product_name", "name": "Parasolid V36.1" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2024-32635", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the unmapped memory region while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_T files in Parasolid", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update to V35.1.256 or later version", "product_ids": [ "1" ] }, { "category": "vendor_fix", "details": "Update to V36.0.208 or later version", "product_ids": [ "2" ] }, { "category": "vendor_fix", "details": "Update to V36.1.173 or later version", "product_ids": [ "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2024-32635" }, { "cve": "CVE-2024-32636", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_T files in Parasolid", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update to V35.1.256 or later version", "product_ids": [ "1" ] }, { "category": "vendor_fix", "details": "Update to V36.0.208 or later version", "product_ids": [ "2" ] }, { "category": "vendor_fix", "details": "Update to V36.1.173 or later version", "product_ids": [ "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2024-32636" }, { "cve": "CVE-2024-32637", "cwe": { "id": "CWE-476", "name": "NULL Pointer Dereference" }, "notes": [ { "category": "summary", "text": "The affected applications contain a null pointer dereference vulnerability while parsing specially crafted X_T files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_T files in Parasolid", "product_ids": [ "1", "2", "3" ] }, { "category": "vendor_fix", "details": "Update to V35.1.256 or later version", "product_ids": [ "1" ] }, { "category": "vendor_fix", "details": "Update to V36.0.208 or later version", "product_ids": [ "2" ] }, { "category": "vendor_fix", "details": "Update to V36.1.173 or later version", "product_ids": [ "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2024-32637" } ] }
NCSC-2024-0332
Vulnerability from csaf_ncscnl
Published
2024-08-13 09:21
Modified
2024-08-13 09:21
Summary
Kwetsbaarheden verholpen in Siemens producten
Notes
The Netherlands Cyber Security Center (henceforth: NCSC-NL) maintains this page to enhance access to its information and security advisories. The use of this security advisory is subject to the following terms and conditions:
NCSC-NL makes every reasonable effort to ensure that the content of this page is kept up to date, and that it is accurate and complete. Nevertheless, NCSC-NL cannot entirely rule out the possibility of errors, and therefore cannot give any warranty in respect of its completeness, accuracy or continuous keeping up-to-date. The information contained in this security advisory is intended solely for the purpose of providing general information to professional users. No rights can be derived from the information provided therein.
NCSC-NL and the Kingdom of the Netherlands assume no legal liability or responsibility for any damage resulting from either the use or inability of use of this security advisory. This includes damage resulting from the inaccuracy of incompleteness of the information contained in the advisory.
This security advisory is subject to Dutch law. All disputes related to or arising from the use of this advisory will be submitted to the competent court in The Hague. This choice of means also applies to the court in summary proceedings.
Feiten
Siemens heeft kwetsbaarheden verholpen in diverse producten als COMOS, INTRALOG, LOGO!, NX, SCALANCE, SINEC en Teamcenter.
Interpretaties
De kwetsbaarheden stellen een kwaadwillende mogelijk in staat aanvallen uit te voeren die kunnen leiden tot de volgende categorieën schade:
- Denial-of-Service (DoS)
- Manipulatie van gegevens
- Omzeilen van een beveiligingsmaatregel
- (Remote) code execution (Administrator/Root rechten)
- (Remote) code execution (Gebruikersrechten)
- Toegang tot systeemgegevens
- Spoofing
- Verhoogde gebruikersrechten
De kwaadwillende heeft hiervoor toegang nodig tot de productieomgeving. Het is goed gebruik een dergelijke omgeving niet publiek toegankelijk te hebben.
Oplossingen
Siemens heeft beveiligingsupdates uitgebracht om de kwetsbaarheden te verhelpen. Voor de kwetsbaarheden waar nog geen updates voor zijn, heeft Siemens mitigerende maatregelen gepubliceerd om de risico's zoveel als mogelijk te beperken. Zie de bijgevoegde referenties voor meer informatie.
Kans
medium
Schade
high
CWE-125
Out-of-bounds Read
CWE-20
Improper Input Validation
CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CWE-250
Execution with Unnecessary Privileges
CWE-256
Plaintext Storage of a Password
CWE-269
Improper Privilege Management
CWE-284
Improper Access Control
CWE-307
Improper Restriction of Excessive Authentication Attempts
CWE-326
Inadequate Encryption Strength
CWE-358
Improperly Implemented Security Check for Standard
CWE-488
Exposure of Data Element to Wrong Session
CWE-521
Weak Password Requirements
CWE-524
Use of Cache Containing Sensitive Information
CWE-532
Insertion of Sensitive Information into Log File
CWE-863
Incorrect Authorization
{ "document": { "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "tlp": { "label": "WHITE" } }, "lang": "nl", "notes": [ { "category": "legal_disclaimer", "text": "The Netherlands Cyber Security Center (henceforth: NCSC-NL) maintains this page to enhance access to its information and security advisories. The use of this security advisory is subject to the following terms and conditions:\n\n NCSC-NL makes every reasonable effort to ensure that the content of this page is kept up to date, and that it is accurate and complete. Nevertheless, NCSC-NL cannot entirely rule out the possibility of errors, and therefore cannot give any warranty in respect of its completeness, accuracy or continuous keeping up-to-date. The information contained in this security advisory is intended solely for the purpose of providing general information to professional users. No rights can be derived from the information provided therein.\n\n NCSC-NL and the Kingdom of the Netherlands assume no legal liability or responsibility for any damage resulting from either the use or inability of use of this security advisory. This includes damage resulting from the inaccuracy of incompleteness of the information contained in the advisory.\n This security advisory is subject to Dutch law. All disputes related to or arising from the use of this advisory will be submitted to the competent court in The Hague. This choice of means also applies to the court in summary proceedings." }, { "category": "description", "text": "Siemens heeft kwetsbaarheden verholpen in diverse producten als COMOS, INTRALOG, LOGO!, NX, SCALANCE, SINEC en Teamcenter.", "title": "Feiten" }, { "category": "description", "text": "De kwetsbaarheden stellen een kwaadwillende mogelijk in staat aanvallen uit te voeren die kunnen leiden tot de volgende categorie\u00ebn schade:\n\n- Denial-of-Service (DoS)\n- Manipulatie van gegevens\n- Omzeilen van een beveiligingsmaatregel\n- (Remote) code execution (Administrator/Root rechten)\n- (Remote) code execution (Gebruikersrechten)\n- Toegang tot systeemgegevens\n- Spoofing\n- Verhoogde gebruikersrechten\n\nDe kwaadwillende heeft hiervoor toegang nodig tot de productieomgeving. Het is goed gebruik een dergelijke omgeving niet publiek toegankelijk te hebben.", "title": "Interpretaties" }, { "category": "description", "text": "Siemens heeft beveiligingsupdates uitgebracht om de kwetsbaarheden te verhelpen. Voor de kwetsbaarheden waar nog geen updates voor zijn, heeft Siemens mitigerende maatregelen gepubliceerd om de risico\u0027s zoveel als mogelijk te beperken. Zie de bijgevoegde referenties voor meer informatie.", "title": "Oplossingen" }, { "category": "general", "text": "medium", "title": "Kans" }, { "category": "general", "text": "high", "title": "Schade" }, { "category": "general", "text": "Out-of-bounds Read", "title": "CWE-125" }, { "category": "general", "text": "Improper Input Validation", "title": "CWE-20" }, { "category": "general", "text": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)", "title": "CWE-22" }, { "category": "general", "text": "Execution with Unnecessary Privileges", "title": "CWE-250" }, { "category": "general", "text": "Plaintext Storage of a Password", "title": "CWE-256" }, { "category": "general", "text": "Improper Privilege Management", "title": "CWE-269" }, { "category": "general", "text": "Improper Access Control", "title": "CWE-284" }, { "category": "general", "text": "Improper Restriction of Excessive Authentication Attempts", "title": "CWE-307" }, { "category": "general", "text": "Inadequate Encryption Strength", "title": "CWE-326" }, { "category": "general", "text": "Improperly Implemented Security Check for Standard", "title": "CWE-358" }, { "category": "general", "text": "Exposure of Data Element to Wrong Session", "title": "CWE-488" }, { "category": "general", "text": "Weak Password Requirements", "title": "CWE-521" }, { "category": "general", "text": "Use of Cache Containing Sensitive Information", "title": "CWE-524" }, { "category": "general", "text": "Insertion of Sensitive Information into Log File", "title": "CWE-532" }, { "category": "general", "text": "Incorrect Authorization", "title": "CWE-863" } ], "publisher": { "category": "coordinator", "contact_details": "cert@ncsc.nl", "name": "Nationaal Cyber Security Centrum", "namespace": "https://www.ncsc.nl/" }, "references": [ { "category": "external", "summary": "Reference - ncscclear", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-087301.pdf" }, { "category": "external", "summary": "Reference - ncscclear", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-357412.pdf" }, { "category": "external", "summary": "Reference - ncscclear", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-417547.pdf" }, { "category": "external", "summary": "Reference - ncscclear", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-659443.pdf" }, { "category": "external", "summary": "Reference - ncscclear", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-716317.pdf" }, { "category": "external", "summary": "Reference - ncscclear", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-720392.pdf" }, { "category": "external", "summary": "Reference - ncscclear", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-784301.pdf" }, { "category": "external", "summary": "Reference - ncscclear", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-856475.pdf" }, { "category": "external", "summary": "Reference - ncscclear", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-921449.pdf" } ], "title": "Kwetsbaarheden verholpen in Siemens producten", "tracking": { "current_release_date": "2024-08-13T09:21:28.381575Z", "id": "NCSC-2024-0332", "initial_release_date": "2024-08-13T09:21:28.381575Z", "revision_history": [ { "date": "2024-08-13T09:21:28.381575Z", "number": "0", "summary": "Initiele versie" } ], "status": "final", "version": "1.0.0" } }, "vulnerabilities": [ { "cve": "CVE-2023-4611", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "other", "text": "Use After Free", "title": "CWE-416" } ], "references": [ { "category": "self", "summary": "CVE-2023-4611", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-4611.json" } ], "title": "CVE-2023-4611" }, { "cve": "CVE-2023-5180", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "other", "text": "Out-of-bounds Write", "title": "CWE-787" } ], "references": [ { "category": "self", "summary": "CVE-2023-5180", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-5180.json" } ], "title": "CVE-2023-5180" }, { "cve": "CVE-2023-5868", "cwe": { "id": "CWE-200", "name": "Exposure of Sensitive Information to an Unauthorized Actor" }, "notes": [ { "category": "other", "text": "Exposure of Sensitive Information to an Unauthorized Actor", "title": "CWE-200" }, { "category": "other", "text": "Function Call With Incorrect Argument Type", "title": "CWE-686" } ], "references": [ { "category": "self", "summary": "CVE-2023-5868", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-5868.json" } ], "title": "CVE-2023-5868" }, { "cve": "CVE-2023-5869", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "other", "text": "Integer Overflow or Wraparound", "title": "CWE-190" }, { "category": "other", "text": "Improper Restriction of Operations within the Bounds of a Memory Buffer", "title": "CWE-119" } ], "references": [ { "category": "self", "summary": "CVE-2023-5869", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-5869.json" } ], "title": "CVE-2023-5869" }, { "cve": "CVE-2023-5870", "cwe": { "id": "CWE-404", "name": "Improper Resource Shutdown or Release" }, "notes": [ { "category": "other", "text": "Improper Resource Shutdown or Release", "title": "CWE-404" }, { "category": "other", "text": "Uncontrolled Resource Consumption", "title": "CWE-400" } ], "references": [ { "category": "self", "summary": "CVE-2023-5870", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-5870.json" } ], "title": "CVE-2023-5870" }, { "cve": "CVE-2023-6378", "cwe": { "id": "CWE-499", "name": "Serializable Class Containing Sensitive Data" }, "notes": [ { "category": "other", "text": "Serializable Class Containing Sensitive Data", "title": "CWE-499" } ], "references": [ { "category": "self", "summary": "CVE-2023-6378", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-6378.json" } ], "title": "CVE-2023-6378" }, { "cve": "CVE-2023-6481", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "other", "text": "Uncontrolled Resource Consumption", "title": "CWE-400" } ], "references": [ { "category": "self", "summary": "CVE-2023-6481", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-6481.json" } ], "title": "CVE-2023-6481" }, { "cve": "CVE-2023-26495", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "other", "text": "Use After Free", "title": "CWE-416" } ], "references": [ { "category": "self", "summary": "CVE-2023-26495", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-26495.json" } ], "title": "CVE-2023-26495" }, { "cve": "CVE-2023-31122", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "other", "text": "Out-of-bounds Read", "title": "CWE-125" } ], "references": [ { "category": "self", "summary": "CVE-2023-31122", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-31122.json" } ], "title": "CVE-2023-31122" }, { "cve": "CVE-2023-34050", "cwe": { "id": "CWE-502", "name": "Deserialization of Untrusted Data" }, "notes": [ { "category": "other", "text": "Deserialization of Untrusted Data", "title": "CWE-502" } ], "references": [ { "category": "self", "summary": "CVE-2023-34050", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-34050.json" } ], "title": "CVE-2023-34050" }, { "cve": "CVE-2023-39615", "cwe": { "id": "CWE-119", "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer" }, "notes": [ { "category": "other", "text": "Improper Restriction of Operations within the Bounds of a Memory Buffer", "title": "CWE-119" } ], "references": [ { "category": "self", "summary": "CVE-2023-39615", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-39615.json" } ], "title": "CVE-2023-39615" }, { "cve": "CVE-2023-42794", "cwe": { "id": "CWE-459", "name": "Incomplete Cleanup" }, "notes": [ { "category": "other", "text": "Incomplete Cleanup", "title": "CWE-459" } ], "references": [ { "category": "self", "summary": "CVE-2023-42794", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-42794.json" } ], "title": "CVE-2023-42794" }, { "cve": "CVE-2023-42795", "cwe": { "id": "CWE-459", "name": "Incomplete Cleanup" }, "notes": [ { "category": "other", "text": "Incomplete Cleanup", "title": "CWE-459" } ], "references": [ { "category": "self", "summary": "CVE-2023-42795", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-42795.json" } ], "title": "CVE-2023-42795" }, { "cve": "CVE-2023-43622", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "other", "text": "Uncontrolled Resource Consumption", "title": "CWE-400" } ], "references": [ { "category": "self", "summary": "CVE-2023-43622", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-43622.json" } ], "title": "CVE-2023-43622" }, { "cve": "CVE-2023-44321", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "other", "text": "Uncontrolled Resource Consumption", "title": "CWE-400" } ], "references": [ { "category": "self", "summary": "CVE-2023-44321", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-44321.json" } ], "title": "CVE-2023-44321" }, { "cve": "CVE-2023-44487", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "other", "text": "Uncontrolled Resource Consumption", "title": "CWE-400" } ], "references": [ { "category": "self", "summary": "CVE-2023-44487", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-44487.json" } ], "title": "CVE-2023-44487" }, { "cve": "CVE-2023-45648", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "other", "text": "Improper Input Validation", "title": "CWE-20" } ], "references": [ { "category": "self", "summary": "CVE-2023-45648", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-45648.json" } ], "title": "CVE-2023-45648" }, { "cve": "CVE-2023-45802", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "other", "text": "Uncontrolled Resource Consumption", "title": "CWE-400" } ], "references": [ { "category": "self", "summary": "CVE-2023-45802", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-45802.json" } ], "title": "CVE-2023-45802" }, { "cve": "CVE-2023-46120", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "other", "text": "Uncontrolled Resource Consumption", "title": "CWE-400" } ], "references": [ { "category": "self", "summary": "CVE-2023-46120", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-46120.json" } ], "title": "CVE-2023-46120" }, { "cve": "CVE-2023-46280", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "other", "text": "Out-of-bounds Read", "title": "CWE-125" } ], "references": [ { "category": "self", "summary": "CVE-2023-46280", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-46280.json" } ], "title": "CVE-2023-46280" }, { "cve": "CVE-2023-46589", "cwe": { "id": "CWE-444", "name": "Inconsistent Interpretation of HTTP Requests (\u0027HTTP Request/Response Smuggling\u0027)" }, "notes": [ { "category": "other", "text": "Inconsistent Interpretation of HTTP Requests (\u0027HTTP Request/Response Smuggling\u0027)", "title": "CWE-444" }, { "category": "other", "text": "Improper Input Validation", "title": "CWE-20" } ], "references": [ { "category": "self", "summary": "CVE-2023-46589", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-46589.json" } ], "title": "CVE-2023-46589" }, { "cve": "CVE-2023-52425", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "other", "text": "Uncontrolled Resource Consumption", "title": "CWE-400" } ], "references": [ { "category": "self", "summary": "CVE-2023-52425", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-52425.json" } ], "title": "CVE-2023-52425" }, { "cve": "CVE-2023-52426", "cwe": { "id": "CWE-776", "name": "Improper Restriction of Recursive Entity References in DTDs (\u0027XML Entity Expansion\u0027)" }, "notes": [ { "category": "other", "text": "Improper Restriction of Recursive Entity References in DTDs (\u0027XML Entity Expansion\u0027)", "title": "CWE-776" } ], "references": [ { "category": "self", "summary": "CVE-2023-52426", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-52426.json" } ], "title": "CVE-2023-52426" }, { "cve": "CVE-2024-0056", "cwe": { "id": "CWE-420", "name": "Unprotected Alternate Channel" }, "notes": [ { "category": "other", "text": "Unprotected Alternate Channel", "title": "CWE-420" }, { "category": "other", "text": "Cleartext Transmission of Sensitive Information", "title": "CWE-319" } ], "references": [ { "category": "self", "summary": "CVE-2024-0056", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-0056.json" } ], "title": "CVE-2024-0056" }, { "cve": "CVE-2024-0985", "cwe": { "id": "CWE-271", "name": "Privilege Dropping / Lowering Errors" }, "notes": [ { "category": "other", "text": "Privilege Dropping / Lowering Errors", "title": "CWE-271" } ], "references": [ { "category": "self", "summary": "CVE-2024-0985", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-0985.json" } ], "title": "CVE-2024-0985" }, { "cve": "CVE-2024-25062", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "other", "text": "Use After Free", "title": "CWE-416" } ], "references": [ { "category": "self", "summary": "CVE-2024-25062", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-25062.json" } ], "title": "CVE-2024-25062" }, { "cve": "CVE-2024-28182", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "other", "text": "Uncontrolled Resource Consumption", "title": "CWE-400" }, { "category": "other", "text": "Improper Resource Shutdown or Release", "title": "CWE-404" }, { "category": "other", "text": "Detection of Error Condition Without Action", "title": "CWE-390" }, { "category": "other", "text": "Allocation of Resources Without Limits or Throttling", "title": "CWE-770" } ], "references": [ { "category": "self", "summary": "CVE-2024-28182", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-28182.json" } ], "title": "CVE-2024-28182" }, { "cve": "CVE-2024-28757", "cwe": { "id": "CWE-611", "name": "Improper Restriction of XML External Entity Reference" }, "notes": [ { "category": "other", "text": "Improper Restriction of XML External Entity Reference", "title": "CWE-611" }, { "category": "other", "text": "Improper Restriction of Recursive Entity References in DTDs (\u0027XML Entity Expansion\u0027)", "title": "CWE-776" }, { "category": "other", "text": "Improper Input Validation", "title": "CWE-20" } ], "references": [ { "category": "self", "summary": "CVE-2024-28757", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-28757.json" } ], "title": "CVE-2024-28757" }, { "cve": "CVE-2024-30045", "cwe": { "id": "CWE-119", "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer" }, "notes": [ { "category": "other", "text": "Improper Restriction of Operations within the Bounds of a Memory Buffer", "title": "CWE-119" }, { "category": "other", "text": "Heap-based Buffer Overflow", "title": "CWE-122" } ], "references": [ { "category": "self", "summary": "CVE-2024-30045", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-30045.json" } ], "title": "CVE-2024-30045" }, { "cve": "CVE-2024-32635", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "other", "text": "Out-of-bounds Read", "title": "CWE-125" } ], "references": [ { "category": "self", "summary": "CVE-2024-32635", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-32635.json" } ], "title": "CVE-2024-32635" }, { "cve": "CVE-2024-32636", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "other", "text": "Out-of-bounds Read", "title": "CWE-125" } ], "references": [ { "category": "self", "summary": "CVE-2024-32636", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-32636.json" } ], "title": "CVE-2024-32636" }, { "cve": "CVE-2024-32637", "cwe": { "id": "CWE-476", "name": "NULL Pointer Dereference" }, "notes": [ { "category": "other", "text": "NULL Pointer Dereference", "title": "CWE-476" } ], "references": [ { "category": "self", "summary": "CVE-2024-32637", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-32637.json" } ], "title": "CVE-2024-32637" }, { "cve": "CVE-2024-36398", "cwe": { "id": "CWE-250", "name": "Execution with Unnecessary Privileges" }, "notes": [ { "category": "other", "text": "Execution with Unnecessary Privileges", "title": "CWE-250" } ], "references": [ { "category": "self", "summary": "CVE-2024-36398", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-36398.json" } ], "title": "CVE-2024-36398" }, { "cve": "CVE-2024-39922", "cwe": { "id": "CWE-256", "name": "Plaintext Storage of a Password" }, "notes": [ { "category": "other", "text": "Plaintext Storage of a Password", "title": "CWE-256" } ], "references": [ { "category": "self", "summary": "CVE-2024-39922", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39922.json" } ], "title": "CVE-2024-39922" }, { "cve": "CVE-2024-41681", "cwe": { "id": "CWE-326", "name": "Inadequate Encryption Strength" }, "notes": [ { "category": "other", "text": "Inadequate Encryption Strength", "title": "CWE-326" } ], "references": [ { "category": "self", "summary": "CVE-2024-41681", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-41681.json" } ], "title": "CVE-2024-41681" }, { "cve": "CVE-2024-41682", "cwe": { "id": "CWE-307", "name": "Improper Restriction of Excessive Authentication Attempts" }, "notes": [ { "category": "other", "text": "Improper Restriction of Excessive Authentication Attempts", "title": "CWE-307" } ], "references": [ { "category": "self", "summary": "CVE-2024-41682", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-41682.json" } ], "title": "CVE-2024-41682" }, { "cve": "CVE-2024-41683", "cwe": { "id": "CWE-521", "name": "Weak Password Requirements" }, "notes": [ { "category": "other", "text": "Weak Password Requirements", "title": "CWE-521" } ], "references": [ { "category": "self", "summary": "CVE-2024-41683", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-41683.json" } ], "title": "CVE-2024-41683" }, { "cve": "CVE-2024-41903", "cwe": { "id": "CWE-269", "name": "Improper Privilege Management" }, "notes": [ { "category": "other", "text": "Improper Privilege Management", "title": "CWE-269" } ], "references": [ { "category": "self", "summary": "CVE-2024-41903", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-41903.json" } ], "title": "CVE-2024-41903" }, { "cve": "CVE-2024-41904", "cwe": { "id": "CWE-307", "name": "Improper Restriction of Excessive Authentication Attempts" }, "notes": [ { "category": "other", "text": "Improper Restriction of Excessive Authentication Attempts", "title": "CWE-307" } ], "references": [ { "category": "self", "summary": "CVE-2024-41904", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-41904.json" } ], "title": "CVE-2024-41904" }, { "cve": "CVE-2024-41905", "cwe": { "id": "CWE-284", "name": "Improper Access Control" }, "notes": [ { "category": "other", "text": "Improper Access Control", "title": "CWE-284" } ], "references": [ { "category": "self", "summary": "CVE-2024-41905", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-41905.json" } ], "title": "CVE-2024-41905" }, { "cve": "CVE-2024-41906", "cwe": { "id": "CWE-524", "name": "Use of Cache Containing Sensitive Information" }, "notes": [ { "category": "other", "text": "Use of Cache Containing Sensitive Information", "title": "CWE-524" } ], "references": [ { "category": "self", "summary": "CVE-2024-41906", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-41906.json" } ], "title": "CVE-2024-41906" }, { "cve": "CVE-2024-41907", "cwe": { "id": "CWE-358", "name": "Improperly Implemented Security Check for Standard" }, "notes": [ { "category": "other", "text": "Improperly Implemented Security Check for Standard", "title": "CWE-358" } ], "references": [ { "category": "self", "summary": "CVE-2024-41907", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-41907.json" } ], "title": "CVE-2024-41907" }, { "cve": "CVE-2024-41908", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "other", "text": "Out-of-bounds Read", "title": "CWE-125" } ], "references": [ { "category": "self", "summary": "CVE-2024-41908", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-41908.json" } ], "title": "CVE-2024-41908" }, { "cve": "CVE-2024-41938", "cwe": { "id": "CWE-22", "name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)" }, "notes": [ { "category": "other", "text": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)", "title": "CWE-22" } ], "references": [ { "category": "self", "summary": "CVE-2024-41938", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-41938.json" } ], "title": "CVE-2024-41938" }, { "cve": "CVE-2024-41939", "cwe": { "id": "CWE-863", "name": "Incorrect Authorization" }, "notes": [ { "category": "other", "text": "Incorrect Authorization", "title": "CWE-863" } ], "references": [ { "category": "self", "summary": "CVE-2024-41939", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-41939.json" } ], "title": "CVE-2024-41939" }, { "cve": "CVE-2024-41940", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "other", "text": "Improper Input Validation", "title": "CWE-20" } ], "references": [ { "category": "self", "summary": "CVE-2024-41940", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-41940.json" } ], "title": "CVE-2024-41940" }, { "cve": "CVE-2024-41941", "cwe": { "id": "CWE-863", "name": "Incorrect Authorization" }, "notes": [ { "category": "other", "text": "Incorrect Authorization", "title": "CWE-863" } ], "references": [ { "category": "self", "summary": "CVE-2024-41941", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-41941.json" } ], "title": "CVE-2024-41941" }, { "cve": "CVE-2024-41976", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "other", "text": "Improper Input Validation", "title": "CWE-20" } ], "references": [ { "category": "self", "summary": "CVE-2024-41976", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-41976.json" } ], "title": "CVE-2024-41976" }, { "cve": "CVE-2024-41977", "cwe": { "id": "CWE-488", "name": "Exposure of Data Element to Wrong Session" }, "notes": [ { "category": "other", "text": "Exposure of Data Element to Wrong Session", "title": "CWE-488" } ], "references": [ { "category": "self", "summary": "CVE-2024-41977", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-41977.json" } ], "title": "CVE-2024-41977" }, { "cve": "CVE-2024-41978", "cwe": { "id": "CWE-532", "name": "Insertion of Sensitive Information into Log File" }, "notes": [ { "category": "other", "text": "Insertion of Sensitive Information into Log File", "title": "CWE-532" } ], "references": [ { "category": "self", "summary": "CVE-2024-41978", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-41978.json" } ], "title": "CVE-2024-41978" } ] }
ncsc-2024-0332
Vulnerability from csaf_ncscnl
Published
2024-08-13 09:21
Modified
2024-08-13 09:21
Summary
Kwetsbaarheden verholpen in Siemens producten
Notes
The Netherlands Cyber Security Center (henceforth: NCSC-NL) maintains this page to enhance access to its information and security advisories. The use of this security advisory is subject to the following terms and conditions:
NCSC-NL makes every reasonable effort to ensure that the content of this page is kept up to date, and that it is accurate and complete. Nevertheless, NCSC-NL cannot entirely rule out the possibility of errors, and therefore cannot give any warranty in respect of its completeness, accuracy or continuous keeping up-to-date. The information contained in this security advisory is intended solely for the purpose of providing general information to professional users. No rights can be derived from the information provided therein.
NCSC-NL and the Kingdom of the Netherlands assume no legal liability or responsibility for any damage resulting from either the use or inability of use of this security advisory. This includes damage resulting from the inaccuracy of incompleteness of the information contained in the advisory.
This security advisory is subject to Dutch law. All disputes related to or arising from the use of this advisory will be submitted to the competent court in The Hague. This choice of means also applies to the court in summary proceedings.
Feiten
Siemens heeft kwetsbaarheden verholpen in diverse producten als COMOS, INTRALOG, LOGO!, NX, SCALANCE, SINEC en Teamcenter.
Interpretaties
De kwetsbaarheden stellen een kwaadwillende mogelijk in staat aanvallen uit te voeren die kunnen leiden tot de volgende categorieën schade:
- Denial-of-Service (DoS)
- Manipulatie van gegevens
- Omzeilen van een beveiligingsmaatregel
- (Remote) code execution (Administrator/Root rechten)
- (Remote) code execution (Gebruikersrechten)
- Toegang tot systeemgegevens
- Spoofing
- Verhoogde gebruikersrechten
De kwaadwillende heeft hiervoor toegang nodig tot de productieomgeving. Het is goed gebruik een dergelijke omgeving niet publiek toegankelijk te hebben.
Oplossingen
Siemens heeft beveiligingsupdates uitgebracht om de kwetsbaarheden te verhelpen. Voor de kwetsbaarheden waar nog geen updates voor zijn, heeft Siemens mitigerende maatregelen gepubliceerd om de risico's zoveel als mogelijk te beperken. Zie de bijgevoegde referenties voor meer informatie.
Kans
medium
Schade
high
CWE-125
Out-of-bounds Read
CWE-20
Improper Input Validation
CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CWE-250
Execution with Unnecessary Privileges
CWE-256
Plaintext Storage of a Password
CWE-269
Improper Privilege Management
CWE-284
Improper Access Control
CWE-307
Improper Restriction of Excessive Authentication Attempts
CWE-326
Inadequate Encryption Strength
CWE-358
Improperly Implemented Security Check for Standard
CWE-488
Exposure of Data Element to Wrong Session
CWE-521
Weak Password Requirements
CWE-524
Use of Cache Containing Sensitive Information
CWE-532
Insertion of Sensitive Information into Log File
CWE-863
Incorrect Authorization
{ "document": { "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "tlp": { "label": "WHITE" } }, "lang": "nl", "notes": [ { "category": "legal_disclaimer", "text": "The Netherlands Cyber Security Center (henceforth: NCSC-NL) maintains this page to enhance access to its information and security advisories. The use of this security advisory is subject to the following terms and conditions:\n\n NCSC-NL makes every reasonable effort to ensure that the content of this page is kept up to date, and that it is accurate and complete. Nevertheless, NCSC-NL cannot entirely rule out the possibility of errors, and therefore cannot give any warranty in respect of its completeness, accuracy or continuous keeping up-to-date. The information contained in this security advisory is intended solely for the purpose of providing general information to professional users. No rights can be derived from the information provided therein.\n\n NCSC-NL and the Kingdom of the Netherlands assume no legal liability or responsibility for any damage resulting from either the use or inability of use of this security advisory. This includes damage resulting from the inaccuracy of incompleteness of the information contained in the advisory.\n This security advisory is subject to Dutch law. All disputes related to or arising from the use of this advisory will be submitted to the competent court in The Hague. This choice of means also applies to the court in summary proceedings." }, { "category": "description", "text": "Siemens heeft kwetsbaarheden verholpen in diverse producten als COMOS, INTRALOG, LOGO!, NX, SCALANCE, SINEC en Teamcenter.", "title": "Feiten" }, { "category": "description", "text": "De kwetsbaarheden stellen een kwaadwillende mogelijk in staat aanvallen uit te voeren die kunnen leiden tot de volgende categorie\u00ebn schade:\n\n- Denial-of-Service (DoS)\n- Manipulatie van gegevens\n- Omzeilen van een beveiligingsmaatregel\n- (Remote) code execution (Administrator/Root rechten)\n- (Remote) code execution (Gebruikersrechten)\n- Toegang tot systeemgegevens\n- Spoofing\n- Verhoogde gebruikersrechten\n\nDe kwaadwillende heeft hiervoor toegang nodig tot de productieomgeving. Het is goed gebruik een dergelijke omgeving niet publiek toegankelijk te hebben.", "title": "Interpretaties" }, { "category": "description", "text": "Siemens heeft beveiligingsupdates uitgebracht om de kwetsbaarheden te verhelpen. Voor de kwetsbaarheden waar nog geen updates voor zijn, heeft Siemens mitigerende maatregelen gepubliceerd om de risico\u0027s zoveel als mogelijk te beperken. Zie de bijgevoegde referenties voor meer informatie.", "title": "Oplossingen" }, { "category": "general", "text": "medium", "title": "Kans" }, { "category": "general", "text": "high", "title": "Schade" }, { "category": "general", "text": "Out-of-bounds Read", "title": "CWE-125" }, { "category": "general", "text": "Improper Input Validation", "title": "CWE-20" }, { "category": "general", "text": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)", "title": "CWE-22" }, { "category": "general", "text": "Execution with Unnecessary Privileges", "title": "CWE-250" }, { "category": "general", "text": "Plaintext Storage of a Password", "title": "CWE-256" }, { "category": "general", "text": "Improper Privilege Management", "title": "CWE-269" }, { "category": "general", "text": "Improper Access Control", "title": "CWE-284" }, { "category": "general", "text": "Improper Restriction of Excessive Authentication Attempts", "title": "CWE-307" }, { "category": "general", "text": "Inadequate Encryption Strength", "title": "CWE-326" }, { "category": "general", "text": "Improperly Implemented Security Check for Standard", "title": "CWE-358" }, { "category": "general", "text": "Exposure of Data Element to Wrong Session", "title": "CWE-488" }, { "category": "general", "text": "Weak Password Requirements", "title": "CWE-521" }, { "category": "general", "text": "Use of Cache Containing Sensitive Information", "title": "CWE-524" }, { "category": "general", "text": "Insertion of Sensitive Information into Log File", "title": "CWE-532" }, { "category": "general", "text": "Incorrect Authorization", "title": "CWE-863" } ], "publisher": { "category": "coordinator", "contact_details": "cert@ncsc.nl", "name": "Nationaal Cyber Security Centrum", "namespace": "https://www.ncsc.nl/" }, "references": [ { "category": "external", "summary": "Reference - ncscclear", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-087301.pdf" }, { "category": "external", "summary": "Reference - ncscclear", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-357412.pdf" }, { "category": "external", "summary": "Reference - ncscclear", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-417547.pdf" }, { "category": "external", "summary": "Reference - ncscclear", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-659443.pdf" }, { "category": "external", "summary": "Reference - ncscclear", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-716317.pdf" }, { "category": "external", "summary": "Reference - ncscclear", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-720392.pdf" }, { "category": "external", "summary": "Reference - ncscclear", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-784301.pdf" }, { "category": "external", "summary": "Reference - ncscclear", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-856475.pdf" }, { "category": "external", "summary": "Reference - ncscclear", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-921449.pdf" } ], "title": "Kwetsbaarheden verholpen in Siemens producten", "tracking": { "current_release_date": "2024-08-13T09:21:28.381575Z", "id": "NCSC-2024-0332", "initial_release_date": "2024-08-13T09:21:28.381575Z", "revision_history": [ { "date": "2024-08-13T09:21:28.381575Z", "number": "0", "summary": "Initiele versie" } ], "status": "final", "version": "1.0.0" } }, "vulnerabilities": [ { "cve": "CVE-2023-4611", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "other", "text": "Use After Free", "title": "CWE-416" } ], "references": [ { "category": "self", "summary": "CVE-2023-4611", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-4611.json" } ], "title": "CVE-2023-4611" }, { "cve": "CVE-2023-5180", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "other", "text": "Out-of-bounds Write", "title": "CWE-787" } ], "references": [ { "category": "self", "summary": "CVE-2023-5180", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-5180.json" } ], "title": "CVE-2023-5180" }, { "cve": "CVE-2023-5868", "cwe": { "id": "CWE-200", "name": "Exposure of Sensitive Information to an Unauthorized Actor" }, "notes": [ { "category": "other", "text": "Exposure of Sensitive Information to an Unauthorized Actor", "title": "CWE-200" }, { "category": "other", "text": "Function Call With Incorrect Argument Type", "title": "CWE-686" } ], "references": [ { "category": "self", "summary": "CVE-2023-5868", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-5868.json" } ], "title": "CVE-2023-5868" }, { "cve": "CVE-2023-5869", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "other", "text": "Integer Overflow or Wraparound", "title": "CWE-190" }, { "category": "other", "text": "Improper Restriction of Operations within the Bounds of a Memory Buffer", "title": "CWE-119" } ], "references": [ { "category": "self", "summary": "CVE-2023-5869", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-5869.json" } ], "title": "CVE-2023-5869" }, { "cve": "CVE-2023-5870", "cwe": { "id": "CWE-404", "name": "Improper Resource Shutdown or Release" }, "notes": [ { "category": "other", "text": "Improper Resource Shutdown or Release", "title": "CWE-404" }, { "category": "other", "text": "Uncontrolled Resource Consumption", "title": "CWE-400" } ], "references": [ { "category": "self", "summary": "CVE-2023-5870", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-5870.json" } ], "title": "CVE-2023-5870" }, { "cve": "CVE-2023-6378", "cwe": { "id": "CWE-499", "name": "Serializable Class Containing Sensitive Data" }, "notes": [ { "category": "other", "text": "Serializable Class Containing Sensitive Data", "title": "CWE-499" } ], "references": [ { "category": "self", "summary": "CVE-2023-6378", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-6378.json" } ], "title": "CVE-2023-6378" }, { "cve": "CVE-2023-6481", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "other", "text": "Uncontrolled Resource Consumption", "title": "CWE-400" } ], "references": [ { "category": "self", "summary": "CVE-2023-6481", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-6481.json" } ], "title": "CVE-2023-6481" }, { "cve": "CVE-2023-26495", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "other", "text": "Use After Free", "title": "CWE-416" } ], "references": [ { "category": "self", "summary": "CVE-2023-26495", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-26495.json" } ], "title": "CVE-2023-26495" }, { "cve": "CVE-2023-31122", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "other", "text": "Out-of-bounds Read", "title": "CWE-125" } ], "references": [ { "category": "self", "summary": "CVE-2023-31122", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-31122.json" } ], "title": "CVE-2023-31122" }, { "cve": "CVE-2023-34050", "cwe": { "id": "CWE-502", "name": "Deserialization of Untrusted Data" }, "notes": [ { "category": "other", "text": "Deserialization of Untrusted Data", "title": "CWE-502" } ], "references": [ { "category": "self", "summary": "CVE-2023-34050", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-34050.json" } ], "title": "CVE-2023-34050" }, { "cve": "CVE-2023-39615", "cwe": { "id": "CWE-119", "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer" }, "notes": [ { "category": "other", "text": "Improper Restriction of Operations within the Bounds of a Memory Buffer", "title": "CWE-119" } ], "references": [ { "category": "self", "summary": "CVE-2023-39615", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-39615.json" } ], "title": "CVE-2023-39615" }, { "cve": "CVE-2023-42794", "cwe": { "id": "CWE-459", "name": "Incomplete Cleanup" }, "notes": [ { "category": "other", "text": "Incomplete Cleanup", "title": "CWE-459" } ], "references": [ { "category": "self", "summary": "CVE-2023-42794", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-42794.json" } ], "title": "CVE-2023-42794" }, { "cve": "CVE-2023-42795", "cwe": { "id": "CWE-459", "name": "Incomplete Cleanup" }, "notes": [ { "category": "other", "text": "Incomplete Cleanup", "title": "CWE-459" } ], "references": [ { "category": "self", "summary": "CVE-2023-42795", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-42795.json" } ], "title": "CVE-2023-42795" }, { "cve": "CVE-2023-43622", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "other", "text": "Uncontrolled Resource Consumption", "title": "CWE-400" } ], "references": [ { "category": "self", "summary": "CVE-2023-43622", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-43622.json" } ], "title": "CVE-2023-43622" }, { "cve": "CVE-2023-44321", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "other", "text": "Uncontrolled Resource Consumption", "title": "CWE-400" } ], "references": [ { "category": "self", "summary": "CVE-2023-44321", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-44321.json" } ], "title": "CVE-2023-44321" }, { "cve": "CVE-2023-44487", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "other", "text": "Uncontrolled Resource Consumption", "title": "CWE-400" } ], "references": [ { "category": "self", "summary": "CVE-2023-44487", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-44487.json" } ], "title": "CVE-2023-44487" }, { "cve": "CVE-2023-45648", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "other", "text": "Improper Input Validation", "title": "CWE-20" } ], "references": [ { "category": "self", "summary": "CVE-2023-45648", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-45648.json" } ], "title": "CVE-2023-45648" }, { "cve": "CVE-2023-45802", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "other", "text": "Uncontrolled Resource Consumption", "title": "CWE-400" } ], "references": [ { "category": "self", "summary": "CVE-2023-45802", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-45802.json" } ], "title": "CVE-2023-45802" }, { "cve": "CVE-2023-46120", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "other", "text": "Uncontrolled Resource Consumption", "title": "CWE-400" } ], "references": [ { "category": "self", "summary": "CVE-2023-46120", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-46120.json" } ], "title": "CVE-2023-46120" }, { "cve": "CVE-2023-46280", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "other", "text": "Out-of-bounds Read", "title": "CWE-125" } ], "references": [ { "category": "self", "summary": "CVE-2023-46280", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-46280.json" } ], "title": "CVE-2023-46280" }, { "cve": "CVE-2023-46589", "cwe": { "id": "CWE-444", "name": "Inconsistent Interpretation of HTTP Requests (\u0027HTTP Request/Response Smuggling\u0027)" }, "notes": [ { "category": "other", "text": "Inconsistent Interpretation of HTTP Requests (\u0027HTTP Request/Response Smuggling\u0027)", "title": "CWE-444" }, { "category": "other", "text": "Improper Input Validation", "title": "CWE-20" } ], "references": [ { "category": "self", "summary": "CVE-2023-46589", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-46589.json" } ], "title": "CVE-2023-46589" }, { "cve": "CVE-2023-52425", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "other", "text": "Uncontrolled Resource Consumption", "title": "CWE-400" } ], "references": [ { "category": "self", "summary": "CVE-2023-52425", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-52425.json" } ], "title": "CVE-2023-52425" }, { "cve": "CVE-2023-52426", "cwe": { "id": "CWE-776", "name": "Improper Restriction of Recursive Entity References in DTDs (\u0027XML Entity Expansion\u0027)" }, "notes": [ { "category": "other", "text": "Improper Restriction of Recursive Entity References in DTDs (\u0027XML Entity Expansion\u0027)", "title": "CWE-776" } ], "references": [ { "category": "self", "summary": "CVE-2023-52426", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2023/CVE-2023-52426.json" } ], "title": "CVE-2023-52426" }, { "cve": "CVE-2024-0056", "cwe": { "id": "CWE-420", "name": "Unprotected Alternate Channel" }, "notes": [ { "category": "other", "text": "Unprotected Alternate Channel", "title": "CWE-420" }, { "category": "other", "text": "Cleartext Transmission of Sensitive Information", "title": "CWE-319" } ], "references": [ { "category": "self", "summary": "CVE-2024-0056", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-0056.json" } ], "title": "CVE-2024-0056" }, { "cve": "CVE-2024-0985", "cwe": { "id": "CWE-271", "name": "Privilege Dropping / Lowering Errors" }, "notes": [ { "category": "other", "text": "Privilege Dropping / Lowering Errors", "title": "CWE-271" } ], "references": [ { "category": "self", "summary": "CVE-2024-0985", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-0985.json" } ], "title": "CVE-2024-0985" }, { "cve": "CVE-2024-25062", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "other", "text": "Use After Free", "title": "CWE-416" } ], "references": [ { "category": "self", "summary": "CVE-2024-25062", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-25062.json" } ], "title": "CVE-2024-25062" }, { "cve": "CVE-2024-28182", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "other", "text": "Uncontrolled Resource Consumption", "title": "CWE-400" }, { "category": "other", "text": "Improper Resource Shutdown or Release", "title": "CWE-404" }, { "category": "other", "text": "Detection of Error Condition Without Action", "title": "CWE-390" }, { "category": "other", "text": "Allocation of Resources Without Limits or Throttling", "title": "CWE-770" } ], "references": [ { "category": "self", "summary": "CVE-2024-28182", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-28182.json" } ], "title": "CVE-2024-28182" }, { "cve": "CVE-2024-28757", "cwe": { "id": "CWE-611", "name": "Improper Restriction of XML External Entity Reference" }, "notes": [ { "category": "other", "text": "Improper Restriction of XML External Entity Reference", "title": "CWE-611" }, { "category": "other", "text": "Improper Restriction of Recursive Entity References in DTDs (\u0027XML Entity Expansion\u0027)", "title": "CWE-776" }, { "category": "other", "text": "Improper Input Validation", "title": "CWE-20" } ], "references": [ { "category": "self", "summary": "CVE-2024-28757", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-28757.json" } ], "title": "CVE-2024-28757" }, { "cve": "CVE-2024-30045", "cwe": { "id": "CWE-119", "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer" }, "notes": [ { "category": "other", "text": "Improper Restriction of Operations within the Bounds of a Memory Buffer", "title": "CWE-119" }, { "category": "other", "text": "Heap-based Buffer Overflow", "title": "CWE-122" } ], "references": [ { "category": "self", "summary": "CVE-2024-30045", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-30045.json" } ], "title": "CVE-2024-30045" }, { "cve": "CVE-2024-32635", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "other", "text": "Out-of-bounds Read", "title": "CWE-125" } ], "references": [ { "category": "self", "summary": "CVE-2024-32635", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-32635.json" } ], "title": "CVE-2024-32635" }, { "cve": "CVE-2024-32636", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "other", "text": "Out-of-bounds Read", "title": "CWE-125" } ], "references": [ { "category": "self", "summary": "CVE-2024-32636", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-32636.json" } ], "title": "CVE-2024-32636" }, { "cve": "CVE-2024-32637", "cwe": { "id": "CWE-476", "name": "NULL Pointer Dereference" }, "notes": [ { "category": "other", "text": "NULL Pointer Dereference", "title": "CWE-476" } ], "references": [ { "category": "self", "summary": "CVE-2024-32637", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-32637.json" } ], "title": "CVE-2024-32637" }, { "cve": "CVE-2024-36398", "cwe": { "id": "CWE-250", "name": "Execution with Unnecessary Privileges" }, "notes": [ { "category": "other", "text": "Execution with Unnecessary Privileges", "title": "CWE-250" } ], "references": [ { "category": "self", "summary": "CVE-2024-36398", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-36398.json" } ], "title": "CVE-2024-36398" }, { "cve": "CVE-2024-39922", "cwe": { "id": "CWE-256", "name": "Plaintext Storage of a Password" }, "notes": [ { "category": "other", "text": "Plaintext Storage of a Password", "title": "CWE-256" } ], "references": [ { "category": "self", "summary": "CVE-2024-39922", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-39922.json" } ], "title": "CVE-2024-39922" }, { "cve": "CVE-2024-41681", "cwe": { "id": "CWE-326", "name": "Inadequate Encryption Strength" }, "notes": [ { "category": "other", "text": "Inadequate Encryption Strength", "title": "CWE-326" } ], "references": [ { "category": "self", "summary": "CVE-2024-41681", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-41681.json" } ], "title": "CVE-2024-41681" }, { "cve": "CVE-2024-41682", "cwe": { "id": "CWE-307", "name": "Improper Restriction of Excessive Authentication Attempts" }, "notes": [ { "category": "other", "text": "Improper Restriction of Excessive Authentication Attempts", "title": "CWE-307" } ], "references": [ { "category": "self", "summary": "CVE-2024-41682", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-41682.json" } ], "title": "CVE-2024-41682" }, { "cve": "CVE-2024-41683", "cwe": { "id": "CWE-521", "name": "Weak Password Requirements" }, "notes": [ { "category": "other", "text": "Weak Password Requirements", "title": "CWE-521" } ], "references": [ { "category": "self", "summary": "CVE-2024-41683", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-41683.json" } ], "title": "CVE-2024-41683" }, { "cve": "CVE-2024-41903", "cwe": { "id": "CWE-269", "name": "Improper Privilege Management" }, "notes": [ { "category": "other", "text": "Improper Privilege Management", "title": "CWE-269" } ], "references": [ { "category": "self", "summary": "CVE-2024-41903", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-41903.json" } ], "title": "CVE-2024-41903" }, { "cve": "CVE-2024-41904", "cwe": { "id": "CWE-307", "name": "Improper Restriction of Excessive Authentication Attempts" }, "notes": [ { "category": "other", "text": "Improper Restriction of Excessive Authentication Attempts", "title": "CWE-307" } ], "references": [ { "category": "self", "summary": "CVE-2024-41904", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-41904.json" } ], "title": "CVE-2024-41904" }, { "cve": "CVE-2024-41905", "cwe": { "id": "CWE-284", "name": "Improper Access Control" }, "notes": [ { "category": "other", "text": "Improper Access Control", "title": "CWE-284" } ], "references": [ { "category": "self", "summary": "CVE-2024-41905", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-41905.json" } ], "title": "CVE-2024-41905" }, { "cve": "CVE-2024-41906", "cwe": { "id": "CWE-524", "name": "Use of Cache Containing Sensitive Information" }, "notes": [ { "category": "other", "text": "Use of Cache Containing Sensitive Information", "title": "CWE-524" } ], "references": [ { "category": "self", "summary": "CVE-2024-41906", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-41906.json" } ], "title": "CVE-2024-41906" }, { "cve": "CVE-2024-41907", "cwe": { "id": "CWE-358", "name": "Improperly Implemented Security Check for Standard" }, "notes": [ { "category": "other", "text": "Improperly Implemented Security Check for Standard", "title": "CWE-358" } ], "references": [ { "category": "self", "summary": "CVE-2024-41907", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-41907.json" } ], "title": "CVE-2024-41907" }, { "cve": "CVE-2024-41908", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "other", "text": "Out-of-bounds Read", "title": "CWE-125" } ], "references": [ { "category": "self", "summary": "CVE-2024-41908", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-41908.json" } ], "title": "CVE-2024-41908" }, { "cve": "CVE-2024-41938", "cwe": { "id": "CWE-22", "name": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)" }, "notes": [ { "category": "other", "text": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)", "title": "CWE-22" } ], "references": [ { "category": "self", "summary": "CVE-2024-41938", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-41938.json" } ], "title": "CVE-2024-41938" }, { "cve": "CVE-2024-41939", "cwe": { "id": "CWE-863", "name": "Incorrect Authorization" }, "notes": [ { "category": "other", "text": "Incorrect Authorization", "title": "CWE-863" } ], "references": [ { "category": "self", "summary": "CVE-2024-41939", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-41939.json" } ], "title": "CVE-2024-41939" }, { "cve": "CVE-2024-41940", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "other", "text": "Improper Input Validation", "title": "CWE-20" } ], "references": [ { "category": "self", "summary": "CVE-2024-41940", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-41940.json" } ], "title": "CVE-2024-41940" }, { "cve": "CVE-2024-41941", "cwe": { "id": "CWE-863", "name": "Incorrect Authorization" }, "notes": [ { "category": "other", "text": "Incorrect Authorization", "title": "CWE-863" } ], "references": [ { "category": "self", "summary": "CVE-2024-41941", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-41941.json" } ], "title": "CVE-2024-41941" }, { "cve": "CVE-2024-41976", "cwe": { "id": "CWE-20", "name": "Improper Input Validation" }, "notes": [ { "category": "other", "text": "Improper Input Validation", "title": "CWE-20" } ], "references": [ { "category": "self", "summary": "CVE-2024-41976", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-41976.json" } ], "title": "CVE-2024-41976" }, { "cve": "CVE-2024-41977", "cwe": { "id": "CWE-488", "name": "Exposure of Data Element to Wrong Session" }, "notes": [ { "category": "other", "text": "Exposure of Data Element to Wrong Session", "title": "CWE-488" } ], "references": [ { "category": "self", "summary": "CVE-2024-41977", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-41977.json" } ], "title": "CVE-2024-41977" }, { "cve": "CVE-2024-41978", "cwe": { "id": "CWE-532", "name": "Insertion of Sensitive Information into Log File" }, "notes": [ { "category": "other", "text": "Insertion of Sensitive Information into Log File", "title": "CWE-532" } ], "references": [ { "category": "self", "summary": "CVE-2024-41978", "url": "https://api.ncsc.nl/velma/v1/vulnerabilities/2024/CVE-2024-41978.json" } ], "title": "CVE-2024-41978" } ] }
ghsa-3h7r-9fxc-5mxj
Vulnerability from github
Published
2024-05-14 18:31
Modified
2024-08-13 09:30
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.3 (High) - CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
7.3 (High) - CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Details
A vulnerability has been identified in Parasolid V35.1 (All versions < V35.1.256), Parasolid V36.0 (All versions < V36.0.208), Parasolid V36.1 (All versions < V36.1.173). The affected applications contain an out of bounds read past the unmapped memory region while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.
{ "affected": [], "aliases": [ "CVE-2024-32635" ], "database_specific": { "cwe_ids": [ "CWE-125" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2024-05-14T16:17:04Z", "severity": "HIGH" }, "details": "A vulnerability has been identified in Parasolid V35.1 (All versions \u003c V35.1.256), Parasolid V36.0 (All versions \u003c V36.0.208), Parasolid V36.1 (All versions \u003c V36.1.173). The affected applications contain an out of bounds read past the unmapped memory region while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.", "id": "GHSA-3h7r-9fxc-5mxj", "modified": "2024-08-13T09:30:52Z", "published": "2024-05-14T18:31:00Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2024-32635" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/html/ssa-046364.html" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/html/ssa-856475.html" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "type": "CVSS_V3" }, { "score": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "type": "CVSS_V4" } ] }
gsd-2024-32635
Vulnerability from gsd
Modified
2024-04-17 05:01
Details
** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided.
Aliases
{ "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2024-32635" ], "id": "GSD-2024-32635", "modified": "2024-04-17T05:01:56.875136Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2024-32635", "STATE": "RESERVED" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "** RESERVED ** This candidate has been reserved by an organization or individual that will use it when announcing a new security problem. When the candidate has been publicized, the details for this candidate will be provided." } ] } } } }
ICSA-24-137-01
Vulnerability from csaf_cisa
Published
2024-05-14 00:00
Modified
2024-05-14 00:00
Summary
Siemens Parasolid
Notes
Summary
Parasolid is affected by out of bounds read and null pointer dereference vulnerabilities that could be triggered when the application reads files in X_T format. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the out of bounds read vulnerabilities to perform remote code execution in the context of the current process or denial of service condition in the application.
Siemens has released new versions for the affected products and recommends to update to the latest versions.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download:
https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Advisory Conversion Disclaimer
This CISA CSAF advisory was converted from Siemens ProductCERT's CSAF advisory.
Critical infrastructure sectors
Multiple
Countries/areas deployed
Worldwide
Company headquarters location
Germany
Recommended Practices
CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.
Recommended Practices
Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.
Recommended Practices
Locate control system networks and remote devices behind firewalls and isolate them from business networks.
Recommended Practices
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
{ "document": { "acknowledgments": [ { "names": [ "Jin Huang" ], "organization": "ADLab of Venustech", "summary": "reporting these vulnerabilities to Siemens." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en", "notes": [ { "category": "summary", "text": "Parasolid is affected by out of bounds read and null pointer dereference vulnerabilities that could be triggered when the application reads files in X_T format. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the out of bounds read vulnerabilities to perform remote code execution in the context of the current process or denial of service condition in the application. \n\nSiemens has released new versions for the affected products and recommends to update to the latest versions.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-046364: X_T File Parsing Vulnerabilities in Parasolid - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-046364.json" }, { "category": "self", "summary": "SSA-046364: X_T File Parsing Vulnerabilities in Parasolid - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-046364.html" }, { "category": "self", "summary": "SSA-046364: X_T File Parsing Vulnerabilities in Parasolid - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-046364.pdf" }, { "category": "self", "summary": "SSA-046364: X_T File Parsing Vulnerabilities in Parasolid - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-046364.txt" }, { "category": "self", "summary": "ICS Advisory ICSA-24-137-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-137-01.json" }, { "category": "self", "summary": "ICS Advisory ICSA-24-137-01 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-137-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens Parasolid", "tracking": { "current_release_date": "2024-05-14T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1" } }, "id": "ICSA-24-137-01", "initial_release_date": "2024-05-14T00:00:00.000000Z", "revision_history": [ { "date": "2024-05-14T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV35.1.256", "product": { "name": "Parasolid V35.1", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "Parasolid V35.1" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV36.0.208", "product": { "name": "Parasolid V36.0", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "Parasolid V36.0" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV36.1.173", "product": { "name": "Parasolid V36.1", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "Parasolid V36.1" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2024-32635", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the unmapped memory region while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_T files in Parasolid", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V35.1.256 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V36.0.208 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V36.1.173 or later version", "product_ids": [ "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2024-32635" }, { "cve": "CVE-2024-32636", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_T files in Parasolid", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V35.1.256 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V36.0.208 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V36.1.173 or later version", "product_ids": [ "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2024-32636" }, { "cve": "CVE-2024-32637", "cwe": { "id": "CWE-476", "name": "NULL Pointer Dereference" }, "notes": [ { "category": "summary", "text": "The affected applications contain a null pointer dereference vulnerability while parsing specially crafted X_T files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_T files in Parasolid", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V35.1.256 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V36.0.208 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V36.1.173 or later version", "product_ids": [ "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2024-32637" } ] }
icsa-24-228-03
Vulnerability from csaf_cisa
Published
2024-08-13 00:00
Modified
2024-08-13 00:00
Summary
Siemens Teamcenter Visualization and JT2Go
Notes
Summary
Teamcenter Visualization and JT2Go are affected by out of bounds read and null pointer dereference vulnerabilities that could be triggered when the application reads files in X_T format. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the vulnerability to perform remote code execution in the context of the current process.
Siemens has released new versions for the affected products and recommends to update to the latest versions.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download:
https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Advisory Conversion Disclaimer
This CISA CSAF advisory was converted from Siemens ProductCERT's CSAF advisory.
Critical infrastructure sectors
Multiple
Countries/areas deployed
Worldwide
Company headquarters location
Germany
Recommended Practices
CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.
Recommended Practices
Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.
Recommended Practices
Locate control system networks and remote devices behind firewalls and isolate them from business networks.
Recommended Practices
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en", "notes": [ { "category": "summary", "text": "Teamcenter Visualization and JT2Go are affected by out of bounds read and null pointer dereference vulnerabilities that could be triggered when the application reads files in X_T format. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the vulnerability to perform remote code execution in the context of the current process.\n\nSiemens has released new versions for the affected products and recommends to update to the latest versions.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-856475: X_T File Parsing Vulnerabilities in Teamcenter Visualization and JT2Go - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-856475.json" }, { "category": "self", "summary": "SSA-856475: X_T File Parsing Vulnerabilities in Teamcenter Visualization and JT2Go - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-856475.html" }, { "category": "self", "summary": "ICS Advisory ICSA-24-228-03 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-228-03.json" }, { "category": "self", "summary": "ICS Advisory ICSA-24-228-03 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-228-03" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens Teamcenter Visualization and JT2Go", "tracking": { "current_release_date": "2024-08-13T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1" } }, "id": "ICSA-24-228-03", "initial_release_date": "2024-08-13T00:00:00.000000Z", "revision_history": [ { "date": "2024-08-13T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV2312.0005", "product": { "name": "JT2Go", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "JT2Go" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV14.2.0.12", "product": { "name": "Teamcenter Visualization V14.2", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "Teamcenter Visualization V14.2" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV14.3.0.10", "product": { "name": "Teamcenter Visualization V14.3", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "Teamcenter Visualization V14.3" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV2312.0005", "product": { "name": "Teamcenter Visualization V2312", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "Teamcenter Visualization V2312" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2024-32635", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the unmapped memory region while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_T files in affected applications", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] }, { "category": "vendor_fix", "details": "Update to V14.2.0.12 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V14.3.0.10 or later version", "product_ids": [ "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V2312.0005 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V2312.0005 or later version", "product_ids": [ "CSAFPID-0004" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] } ], "title": "CVE-2024-32635" }, { "cve": "CVE-2024-32636", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_T files in affected applications", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] }, { "category": "vendor_fix", "details": "Update to V14.2.0.12 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V14.3.0.10 or later version", "product_ids": [ "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V2312.0005 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V2312.0005 or later version", "product_ids": [ "CSAFPID-0004" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] } ], "title": "CVE-2024-32636" }, { "cve": "CVE-2024-32637", "cwe": { "id": "CWE-476", "name": "NULL Pointer Dereference" }, "notes": [ { "category": "summary", "text": "The affected applications contain a null pointer dereference vulnerability while parsing specially crafted X_T files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_T files in affected applications", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] }, { "category": "vendor_fix", "details": "Update to V14.2.0.12 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V14.3.0.10 or later version", "product_ids": [ "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V2312.0005 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V2312.0005 or later version", "product_ids": [ "CSAFPID-0004" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] } ], "title": "CVE-2024-32637" } ] }
ICSA-24-228-03
Vulnerability from csaf_cisa
Published
2024-08-13 00:00
Modified
2024-08-13 00:00
Summary
Siemens Teamcenter Visualization and JT2Go
Notes
Summary
Teamcenter Visualization and JT2Go are affected by out of bounds read and null pointer dereference vulnerabilities that could be triggered when the application reads files in X_T format. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the vulnerability to perform remote code execution in the context of the current process.
Siemens has released new versions for the affected products and recommends to update to the latest versions.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download:
https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Advisory Conversion Disclaimer
This CISA CSAF advisory was converted from Siemens ProductCERT's CSAF advisory.
Critical infrastructure sectors
Multiple
Countries/areas deployed
Worldwide
Company headquarters location
Germany
Recommended Practices
CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.
Recommended Practices
Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.
Recommended Practices
Locate control system networks and remote devices behind firewalls and isolate them from business networks.
Recommended Practices
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en", "notes": [ { "category": "summary", "text": "Teamcenter Visualization and JT2Go are affected by out of bounds read and null pointer dereference vulnerabilities that could be triggered when the application reads files in X_T format. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the vulnerability to perform remote code execution in the context of the current process.\n\nSiemens has released new versions for the affected products and recommends to update to the latest versions.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-856475: X_T File Parsing Vulnerabilities in Teamcenter Visualization and JT2Go - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-856475.json" }, { "category": "self", "summary": "SSA-856475: X_T File Parsing Vulnerabilities in Teamcenter Visualization and JT2Go - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-856475.html" }, { "category": "self", "summary": "ICS Advisory ICSA-24-228-03 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-228-03.json" }, { "category": "self", "summary": "ICS Advisory ICSA-24-228-03 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-228-03" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens Teamcenter Visualization and JT2Go", "tracking": { "current_release_date": "2024-08-13T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1" } }, "id": "ICSA-24-228-03", "initial_release_date": "2024-08-13T00:00:00.000000Z", "revision_history": [ { "date": "2024-08-13T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV2312.0005", "product": { "name": "JT2Go", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "JT2Go" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV14.2.0.12", "product": { "name": "Teamcenter Visualization V14.2", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "Teamcenter Visualization V14.2" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV14.3.0.10", "product": { "name": "Teamcenter Visualization V14.3", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "Teamcenter Visualization V14.3" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV2312.0005", "product": { "name": "Teamcenter Visualization V2312", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "Teamcenter Visualization V2312" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2024-32635", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the unmapped memory region while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_T files in affected applications", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] }, { "category": "vendor_fix", "details": "Update to V14.2.0.12 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V14.3.0.10 or later version", "product_ids": [ "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V2312.0005 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V2312.0005 or later version", "product_ids": [ "CSAFPID-0004" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] } ], "title": "CVE-2024-32635" }, { "cve": "CVE-2024-32636", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_T files in affected applications", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] }, { "category": "vendor_fix", "details": "Update to V14.2.0.12 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V14.3.0.10 or later version", "product_ids": [ "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V2312.0005 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V2312.0005 or later version", "product_ids": [ "CSAFPID-0004" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] } ], "title": "CVE-2024-32636" }, { "cve": "CVE-2024-32637", "cwe": { "id": "CWE-476", "name": "NULL Pointer Dereference" }, "notes": [ { "category": "summary", "text": "The affected applications contain a null pointer dereference vulnerability while parsing specially crafted X_T files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_T files in affected applications", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] }, { "category": "vendor_fix", "details": "Update to V14.2.0.12 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V14.3.0.10 or later version", "product_ids": [ "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V2312.0005 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V2312.0005 or later version", "product_ids": [ "CSAFPID-0004" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004" ] } ], "title": "CVE-2024-32637" } ] }
icsa-24-137-01
Vulnerability from csaf_cisa
Published
2024-05-14 00:00
Modified
2024-05-14 00:00
Summary
Siemens Parasolid
Notes
Summary
Parasolid is affected by out of bounds read and null pointer dereference vulnerabilities that could be triggered when the application reads files in X_T format. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the out of bounds read vulnerabilities to perform remote code execution in the context of the current process or denial of service condition in the application.
Siemens has released new versions for the affected products and recommends to update to the latest versions.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download:
https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Advisory Conversion Disclaimer
This CISA CSAF advisory was converted from Siemens ProductCERT's CSAF advisory.
Critical infrastructure sectors
Multiple
Countries/areas deployed
Worldwide
Company headquarters location
Germany
Recommended Practices
CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.
Recommended Practices
Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.
Recommended Practices
Locate control system networks and remote devices behind firewalls and isolate them from business networks.
Recommended Practices
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
{ "document": { "acknowledgments": [ { "names": [ "Jin Huang" ], "organization": "ADLab of Venustech", "summary": "reporting these vulnerabilities to Siemens." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en", "notes": [ { "category": "summary", "text": "Parasolid is affected by out of bounds read and null pointer dereference vulnerabilities that could be triggered when the application reads files in X_T format. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the out of bounds read vulnerabilities to perform remote code execution in the context of the current process or denial of service condition in the application. \n\nSiemens has released new versions for the affected products and recommends to update to the latest versions.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-046364: X_T File Parsing Vulnerabilities in Parasolid - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-046364.json" }, { "category": "self", "summary": "SSA-046364: X_T File Parsing Vulnerabilities in Parasolid - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-046364.html" }, { "category": "self", "summary": "SSA-046364: X_T File Parsing Vulnerabilities in Parasolid - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-046364.pdf" }, { "category": "self", "summary": "SSA-046364: X_T File Parsing Vulnerabilities in Parasolid - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-046364.txt" }, { "category": "self", "summary": "ICS Advisory ICSA-24-137-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-137-01.json" }, { "category": "self", "summary": "ICS Advisory ICSA-24-137-01 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-137-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens Parasolid", "tracking": { "current_release_date": "2024-05-14T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1" } }, "id": "ICSA-24-137-01", "initial_release_date": "2024-05-14T00:00:00.000000Z", "revision_history": [ { "date": "2024-05-14T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV35.1.256", "product": { "name": "Parasolid V35.1", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "Parasolid V35.1" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV36.0.208", "product": { "name": "Parasolid V36.0", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "Parasolid V36.0" }, { "branches": [ { "category": "product_version_range", "name": "\u003cV36.1.173", "product": { "name": "Parasolid V36.1", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "Parasolid V36.1" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2024-32635", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the unmapped memory region while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_T files in Parasolid", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V35.1.256 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V36.0.208 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V36.1.173 or later version", "product_ids": [ "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2024-32635" }, { "cve": "CVE-2024-32636", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_T files in Parasolid", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V35.1.256 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V36.0.208 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V36.1.173 or later version", "product_ids": [ "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2024-32636" }, { "cve": "CVE-2024-32637", "cwe": { "id": "CWE-476", "name": "NULL Pointer Dereference" }, "notes": [ { "category": "summary", "text": "The affected applications contain a null pointer dereference vulnerability while parsing specially crafted X_T files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "remediations": [ { "category": "mitigation", "details": "Do not open untrusted X_T files in Parasolid", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "vendor_fix", "details": "Update to V35.1.256 or later version", "product_ids": [ "CSAFPID-0001" ] }, { "category": "vendor_fix", "details": "Update to V36.0.208 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update to V36.1.173 or later version", "product_ids": [ "CSAFPID-0003" ] } ], "scores": [ { "cvss_v3": { "baseScore": 3.3, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ], "title": "CVE-2024-32637" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.