Summary
An exposure of sensitive information to an unauthorized actor vulnerability [CWE-200] in FortiManager 7.4.2 and below, 7.2.5 and below, 7.0.12 and below allows a remote authenticated attacker assigned to an Administrative Domain (ADOM) to access device summary of unauthorized ADOMs via crafted HTTP requests.
References
Impacted products
▼ | Vendor | Product |
---|---|---|
Fortinet | FortiManager |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-33506", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-10-08T16:00:39.284052Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-10-08T16:00:49.740Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "cpes": [ "cpe:2.3:o:fortinet:fortimanager:7.4.2:*:*:*:*:*:*:*", "cpe:2.3:o:fortinet:fortimanager:7.4.1:*:*:*:*:*:*:*", "cpe:2.3:o:fortinet:fortimanager:7.4.0:*:*:*:*:*:*:*", "cpe:2.3:o:fortinet:fortimanager:7.2.5:*:*:*:*:*:*:*", "cpe:2.3:o:fortinet:fortimanager:7.2.4:*:*:*:*:*:*:*", "cpe:2.3:o:fortinet:fortimanager:7.2.3:*:*:*:*:*:*:*", "cpe:2.3:o:fortinet:fortimanager:7.2.2:*:*:*:*:*:*:*", "cpe:2.3:o:fortinet:fortimanager:7.2.1:*:*:*:*:*:*:*", "cpe:2.3:o:fortinet:fortimanager:7.2.0:*:*:*:*:*:*:*", "cpe:2.3:o:fortinet:fortimanager:7.0.12:*:*:*:*:*:*:*", "cpe:2.3:o:fortinet:fortimanager:7.0.11:*:*:*:*:*:*:*", "cpe:2.3:o:fortinet:fortimanager:7.0.10:*:*:*:*:*:*:*", "cpe:2.3:o:fortinet:fortimanager:7.0.9:*:*:*:*:*:*:*", "cpe:2.3:o:fortinet:fortimanager:7.0.8:*:*:*:*:*:*:*", "cpe:2.3:o:fortinet:fortimanager:7.0.7:*:*:*:*:*:*:*", "cpe:2.3:o:fortinet:fortimanager:7.0.6:*:*:*:*:*:*:*", "cpe:2.3:o:fortinet:fortimanager:7.0.5:*:*:*:*:*:*:*", "cpe:2.3:o:fortinet:fortimanager:7.0.4:*:*:*:*:*:*:*", "cpe:2.3:o:fortinet:fortimanager:7.0.3:*:*:*:*:*:*:*", "cpe:2.3:o:fortinet:fortimanager:7.0.2:*:*:*:*:*:*:*", "cpe:2.3:o:fortinet:fortimanager:7.0.1:*:*:*:*:*:*:*", "cpe:2.3:o:fortinet:fortimanager:7.0.0:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "FortiManager", "vendor": "Fortinet", "versions": [ { "lessThanOrEqual": "7.4.2", "status": "affected", "version": "7.4.0", "versionType": "semver" }, { "lessThanOrEqual": "7.2.5", "status": "affected", "version": "7.2.0", "versionType": "semver" }, { "lessThanOrEqual": "7.0.12", "status": "affected", "version": "7.0.0", "versionType": "semver" } ] } ], "descriptions": [ { "lang": "en", "value": "An exposure of sensitive information to an unauthorized actor vulnerability [CWE-200] in FortiManager 7.4.2 and below, 7.2.5 and below, 7.0.12 and below allows a remote authenticated attacker assigned to an Administrative Domain (ADOM) to access device summary of unauthorized ADOMs via crafted HTTP requests." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 3.1, "baseSeverity": "LOW", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:W/RC:C", "version": "3.1" }, "format": "CVSS" } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-200", "description": "Information disclosure", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-10-08T14:19:03.883Z", "orgId": "6abe59d8-c742-4dff-8ce8-9b0ca1073da8", "shortName": "fortinet" }, "references": [ { "name": "https://fortiguard.fortinet.com/psirt/FG-IR-23-472", "url": "https://fortiguard.fortinet.com/psirt/FG-IR-23-472" } ], "solutions": [ { "lang": "en", "value": "Please upgrade to FortiManager version 7.4.3 or above \nPlease upgrade to FortiManager version 7.2.6 or above" } ] } }, "cveMetadata": { "assignerOrgId": "6abe59d8-c742-4dff-8ce8-9b0ca1073da8", "assignerShortName": "fortinet", "cveId": "CVE-2024-33506", "datePublished": "2024-10-08T14:19:03.883Z", "dateReserved": "2024-04-23T14:18:29.830Z", "dateUpdated": "2024-10-08T16:00:49.740Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2024-33506\",\"sourceIdentifier\":\"psirt@fortinet.com\",\"published\":\"2024-10-08T15:15:14.717\",\"lastModified\":\"2024-10-10T12:56:30.817\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An exposure of sensitive information to an unauthorized actor vulnerability [CWE-200] in FortiManager 7.4.2 and below, 7.2.5 and below, 7.0.12 and below allows a remote authenticated attacker assigned to an Administrative Domain (ADOM) to access device summary of unauthorized ADOMs via crafted HTTP requests.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad de exposici\u00f3n de informaci\u00f3n confidencial a un actor no autorizado [CWE-200] en FortiManager 7.4.2 y anteriores, 7.2.5 y anteriores, 7.0.12 y anteriores permite que un atacante remoto autenticado asignado a un dominio administrativo (ADOM) acceda al resumen del dispositivo de ADOM no autorizados a trav\u00e9s de solicitudes HTTP manipuladas.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"psirt@fortinet.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":3.3,\"baseSeverity\":\"LOW\"},\"exploitabilityScore\":1.8,\"impactScore\":1.4}]},\"weaknesses\":[{\"source\":\"psirt@fortinet.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-200\"}]}],\"references\":[{\"url\":\"https://fortiguard.fortinet.com/psirt/FG-IR-23-472\",\"source\":\"psirt@fortinet.com\"}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.