cve-2024-37367
Vulnerability from cvelistv5
Published
2024-06-14 14:17
Modified
2024-08-02 03:50
Summary
Rockwell Automation FactoryTalk® View SE v12 Information Leakage Vulnerability via Authentication Restriction
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-37367",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-17T15:37:14.017276Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-17T15:37:26.533Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T03:50:56.151Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1675.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "FactoryTalk\u00ae View SE",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "v12"
            }
          ]
        }
      ],
      "datePublic": "2024-06-13T13:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA user authentication vulnerability exists in the Rockwell Automation FactoryTalk\u00ae View SE v12. The vulnerability allows a user from a remote system with FTView to send a packet to the customer\u2019s server to view an HMI project.  This action is allowed without proper authentication verification.\u003c/span\u003e\n\n"
            }
          ],
          "value": "A user authentication vulnerability exists in the Rockwell Automation FactoryTalk\u00ae View SE v12. The vulnerability allows a user from a remote system with FTView to send a packet to the customer\u2019s server to view an HMI project.  This action is allowed without proper authentication verification."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-114",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-114 Authentication Abuse"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "NETWORK",
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287 Improper Authentication",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-14T14:17:54.951Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1675.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cul\u003e\u003cli\u003eCorrected in software version v14.0. \u003c/li\u003e\u003cli\u003e\u003cp\u003eUsers using the affected software, who are not able to upgrade to one of the corrected versions, are encouraged to apply security best practices, where possible.\u202f\u202f\u202f\u003c/p\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003eIt is recommended that users enforce proper access controls within the network and segment networks containing sensitive information using IPSec: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1090456\"\u003ehttps://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1090456\u003c/a\u003e\u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\"\u003eSecurity Best Practices\u003c/a\u003e\u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e\u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "*  Corrected in software version v14.0. \n  *  Users using the affected software, who are not able to upgrade to one of the corrected versions, are encouraged to apply security best practices, where possible.\u202f\u202f\u202f\n\n  *  It is recommended that users enforce proper access controls within the network and segment networks containing sensitive information using IPSec:  https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1090456 \n\n\n\n\n  *   Security Best Practices https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight"
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "Rockwell Automation FactoryTalk\u00ae View SE v12 Information Leakage Vulnerability via Authentication Restriction",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2024-37367",
    "datePublished": "2024-06-14T14:17:54.951Z",
    "dateReserved": "2024-06-06T20:18:27.551Z",
    "dateUpdated": "2024-08-02T03:50:56.151Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-37367\",\"sourceIdentifier\":\"PSIRT@rockwellautomation.com\",\"published\":\"2024-06-14T15:15:51.940\",\"lastModified\":\"2024-08-16T19:29:01.433\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A user authentication vulnerability exists in the Rockwell Automation FactoryTalk\u00ae View SE v12. The vulnerability allows a user from a remote system with FTView to send a packet to the customer\u2019s server to view an HMI project.  This action is allowed without proper authentication verification.\"},{\"lang\":\"es\",\"value\":\"Existe una vulnerabilidad de autenticaci\u00f3n de usuario en Rockwell Automation FactoryTalk\u00ae View SE v12. La vulnerabilidad permite a un usuario desde un sistema remoto con FTView enviar un paquete al servidor del cliente para ver un proyecto HMI. Esta acci\u00f3n est\u00e1 permitida sin una verificaci\u00f3n de autenticaci\u00f3n adecuada.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"PSIRT@rockwellautomation.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"PRESENT\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"vulnerableSystemConfidentiality\":\"HIGH\",\"vulnerableSystemIntegrity\":\"NONE\",\"vulnerableSystemAvailability\":\"NONE\",\"subsequentSystemConfidentiality\":\"NONE\",\"subsequentSystemIntegrity\":\"NONE\",\"subsequentSystemAvailability\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirements\":\"NOT_DEFINED\",\"integrityRequirements\":\"NOT_DEFINED\",\"availabilityRequirements\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnerableSystemConfidentiality\":\"NOT_DEFINED\",\"modifiedVulnerableSystemIntegrity\":\"NOT_DEFINED\",\"modifiedVulnerableSystemAvailability\":\"NOT_DEFINED\",\"modifiedSubsequentSystemConfidentiality\":\"NOT_DEFINED\",\"modifiedSubsequentSystemIntegrity\":\"NOT_DEFINED\",\"modifiedSubsequentSystemAvailability\":\"NOT_DEFINED\",\"safety\":\"NOT_DEFINED\",\"automatable\":\"NOT_DEFINED\",\"recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\",\"baseScore\":8.2,\"baseSeverity\":\"HIGH\"}}],\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-287\"}]},{\"source\":\"PSIRT@rockwellautomation.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-287\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:factorytalk_view:*:*:*:*:se:*:*:*\",\"versionStartIncluding\":\"12.0\",\"versionEndExcluding\":\"14.0\",\"matchCriteriaId\":\"EFF3850B-DE22-4996-8B0B-1D1B8D36D62A\"}]}]}],\"references\":[{\"url\":\"https://https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1675.html\",\"source\":\"PSIRT@rockwellautomation.com\",\"tags\":[\"Broken Link\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...
  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.