cve-2024-37367
Vulnerability from cvelistv5
Published
2024-06-14 14:17
Modified
2024-08-02 03:50
Severity ?
EPSS score ?
Summary
Rockwell Automation FactoryTalk® View SE v12 Information Leakage Vulnerability via Authentication Restriction
References
Impacted products
▼ | Vendor | Product |
---|---|---|
Rockwell Automation | FactoryTalk® View SE |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-37367", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-06-17T15:37:14.017276Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-17T15:37:26.533Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-02T03:50:56.151Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1675.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "FactoryTalk\u00ae View SE", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "v12" } ] } ], "datePublic": "2024-06-13T13:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA user authentication vulnerability exists in the Rockwell Automation FactoryTalk\u00ae View SE v12. The vulnerability allows a user from a remote system with FTView to send a packet to the customer\u2019s server to view an HMI project. This action is allowed without proper authentication verification.\u003c/span\u003e\n\n" } ], "value": "A user authentication vulnerability exists in the Rockwell Automation FactoryTalk\u00ae View SE v12. The vulnerability allows a user from a remote system with FTView to send a packet to the customer\u2019s server to view an HMI project. This action is allowed without proper authentication verification." } ], "impacts": [ { "capecId": "CAPEC-114", "descriptions": [ { "lang": "en", "value": "CAPEC-114 Authentication Abuse" } ] } ], "metrics": [ { "cvssV4_0": { "Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "PRESENT", "attackVector": "NETWORK", "baseScore": 8.2, "baseSeverity": "HIGH", "privilegesRequired": "NONE", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N", "version": "4.0", "vulnAvailabilityImpact": "NONE", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "NONE", "vulnerabilityResponseEffort": "NOT_DEFINED" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-287", "description": "CWE-287 Improper Authentication", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-06-14T14:17:54.951Z", "orgId": "b73dd486-f505-4403-b634-40b078b177f0", "shortName": "Rockwell" }, "references": [ { "url": "https://https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1675.html" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cul\u003e\u003cli\u003eCorrected in software version v14.0. \u003c/li\u003e\u003cli\u003e\u003cp\u003eUsers using the affected software, who are not able to upgrade to one of the corrected versions, are encouraged to apply security best practices, where possible.\u202f\u202f\u202f\u003c/p\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003eIt is recommended that users enforce proper access controls within the network and segment networks containing sensitive information using IPSec: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1090456\"\u003ehttps://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1090456\u003c/a\u003e\u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\"\u003eSecurity Best Practices\u003c/a\u003e\u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e\u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e" } ], "value": "* Corrected in software version v14.0. \n * Users using the affected software, who are not able to upgrade to one of the corrected versions, are encouraged to apply security best practices, where possible.\u202f\u202f\u202f\n\n * It is recommended that users enforce proper access controls within the network and segment networks containing sensitive information using IPSec: https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1090456 \n\n\n\n\n * Security Best Practices https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight" } ], "source": { "discovery": "INTERNAL" }, "title": "Rockwell Automation FactoryTalk\u00ae View SE v12 Information Leakage Vulnerability via Authentication Restriction", "x_generator": { "engine": "Vulnogram 0.2.0" } } }, "cveMetadata": { "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0", "assignerShortName": "Rockwell", "cveId": "CVE-2024-37367", "datePublished": "2024-06-14T14:17:54.951Z", "dateReserved": "2024-06-06T20:18:27.551Z", "dateUpdated": "2024-08-02T03:50:56.151Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2024-37367\",\"sourceIdentifier\":\"PSIRT@rockwellautomation.com\",\"published\":\"2024-06-14T15:15:51.940\",\"lastModified\":\"2024-08-16T19:29:01.433\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A user authentication vulnerability exists in the Rockwell Automation FactoryTalk\u00ae View SE v12. The vulnerability allows a user from a remote system with FTView to send a packet to the customer\u2019s server to view an HMI project. This action is allowed without proper authentication verification.\"},{\"lang\":\"es\",\"value\":\"Existe una vulnerabilidad de autenticaci\u00f3n de usuario en Rockwell Automation FactoryTalk\u00ae View SE v12. La vulnerabilidad permite a un usuario desde un sistema remoto con FTView enviar un paquete al servidor del cliente para ver un proyecto HMI. Esta acci\u00f3n est\u00e1 permitida sin una verificaci\u00f3n de autenticaci\u00f3n adecuada.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"PSIRT@rockwellautomation.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"PRESENT\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"vulnerableSystemConfidentiality\":\"HIGH\",\"vulnerableSystemIntegrity\":\"NONE\",\"vulnerableSystemAvailability\":\"NONE\",\"subsequentSystemConfidentiality\":\"NONE\",\"subsequentSystemIntegrity\":\"NONE\",\"subsequentSystemAvailability\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirements\":\"NOT_DEFINED\",\"integrityRequirements\":\"NOT_DEFINED\",\"availabilityRequirements\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnerableSystemConfidentiality\":\"NOT_DEFINED\",\"modifiedVulnerableSystemIntegrity\":\"NOT_DEFINED\",\"modifiedVulnerableSystemAvailability\":\"NOT_DEFINED\",\"modifiedSubsequentSystemConfidentiality\":\"NOT_DEFINED\",\"modifiedSubsequentSystemIntegrity\":\"NOT_DEFINED\",\"modifiedSubsequentSystemAvailability\":\"NOT_DEFINED\",\"safety\":\"NOT_DEFINED\",\"automatable\":\"NOT_DEFINED\",\"recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\",\"baseScore\":8.2,\"baseSeverity\":\"HIGH\"}}],\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-287\"}]},{\"source\":\"PSIRT@rockwellautomation.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-287\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:rockwellautomation:factorytalk_view:*:*:*:*:se:*:*:*\",\"versionStartIncluding\":\"12.0\",\"versionEndExcluding\":\"14.0\",\"matchCriteriaId\":\"EFF3850B-DE22-4996-8B0B-1D1B8D36D62A\"}]}]}],\"references\":[{\"url\":\"https://https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1675.html\",\"source\":\"PSIRT@rockwellautomation.com\",\"tags\":[\"Broken Link\"]}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.