CVE-2024-37367 (GCVE-0-2024-37367)
Vulnerability from cvelistv5 – Published: 2024-06-14 14:17 – Updated: 2024-08-02 03:50
VLAI
EPSS
VEX
Title
Rockwell Automation FactoryTalk® View SE v12 Information Leakage Vulnerability via Authentication Restriction
Summary
A user authentication vulnerability exists in the Rockwell Automation FactoryTalk® View SE v12. The vulnerability allows a user from a remote system with FTView to send a packet to the customer’s server to view an HMI project. This action is allowed without proper authentication verification.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-06-17 15:37 UTC
CWE
- CWE-287 - Improper Authentication
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Rockwell Automation | FactoryTalk® View SE |
Affected:
v12
|
guessed |
Date Public
2024-06-13 13:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-37367",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-17T15:37:14.017276Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-17T15:37:26.533Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T03:50:56.151Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1675.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "FactoryTalk\u00ae View SE",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "v12"
}
]
}
],
"datePublic": "2024-06-13T13:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA user authentication vulnerability exists in the Rockwell Automation FactoryTalk\u00ae View SE v12. The vulnerability allows a user from a remote system with FTView to send a packet to the customer\u2019s server to view an HMI project. This action is allowed without proper authentication verification.\u003c/span\u003e\n\n"
}
],
"value": "A user authentication vulnerability exists in the Rockwell Automation FactoryTalk\u00ae View SE v12. The vulnerability allows a user from a remote system with FTView to send a packet to the customer\u2019s server to view an HMI project. This action is allowed without proper authentication verification."
}
],
"impacts": [
{
"capecId": "CAPEC-114",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-114 Authentication Abuse"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287 Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-14T14:17:54.951Z",
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
"shortName": "Rockwell"
},
"references": [
{
"url": "https://https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1675.html"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cul\u003e\u003cli\u003eCorrected in software version v14.0. \u003c/li\u003e\u003cli\u003e\u003cp\u003eUsers using the affected software, who are not able to upgrade to one of the corrected versions, are encouraged to apply security best practices, where possible.\u202f\u202f\u202f\u003c/p\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003eIt is recommended that users enforce proper access controls within the network and segment networks containing sensitive information using IPSec: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1090456\"\u003ehttps://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1090456\u003c/a\u003e\u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\"\u003eSecurity Best Practices\u003c/a\u003e\u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e\u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e"
}
],
"value": "* Corrected in software version v14.0. \n * Users using the affected software, who are not able to upgrade to one of the corrected versions, are encouraged to apply security best practices, where possible.\u202f\u202f\u202f\n\n * It is recommended that users enforce proper access controls within the network and segment networks containing sensitive information using IPSec: https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1090456 \n\n\n\n\n * Security Best Practices https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight"
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "Rockwell Automation FactoryTalk\u00ae View SE v12 Information Leakage Vulnerability via Authentication Restriction",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
"assignerShortName": "Rockwell",
"cveId": "CVE-2024-37367",
"datePublished": "2024-06-14T14:17:54.951Z",
"dateReserved": "2024-06-06T20:18:27.551Z",
"dateUpdated": "2024-08-02T03:50:56.151Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2024-37367",
"date": "2026-09-26",
"epss": "0.00498",
"percentile": "0.40235"
},
"fkie_nvd": {
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:rockwellautomation:factorytalk_view:*:*:*:*:se:*:*:*",
"matchCriteriaId": "EFF3850B-DE22-4996-8B0B-1D1B8D36D62A",
"versionEndExcluding": "14.0",
"versionStartIncluding": "12.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A user authentication vulnerability exists in the Rockwell Automation FactoryTalk\u00ae View SE v12. The vulnerability allows a user from a remote system with FTView to send a packet to the customer\u2019s server to view an HMI project. This action is allowed without proper authentication verification."
},
{
"lang": "es",
"value": "Existe una vulnerabilidad de autenticaci\u00f3n de usuario en Rockwell Automation FactoryTalk\u00ae View SE v12. La vulnerabilidad permite a un usuario desde un sistema remoto con FTView enviar un paquete al servidor del cliente para ver un proyecto HMI. Esta acci\u00f3n est\u00e1 permitida sin una verificaci\u00f3n de autenticaci\u00f3n adecuada."
}
],
"id": "CVE-2024-37367",
"lastModified": "2024-11-21T09:23:43.120",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"automatable": "NOT_DEFINED",
"availabilityRequirements": "NOT_DEFINED",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityRequirements": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirements": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubsequentSystemAvailability": "NOT_DEFINED",
"modifiedSubsequentSystemConfidentiality": "NOT_DEFINED",
"modifiedSubsequentSystemIntegrity": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnerableSystemAvailability": "NOT_DEFINED",
"modifiedVulnerableSystemConfidentiality": "NOT_DEFINED",
"modifiedVulnerableSystemIntegrity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"recovery": "NOT_DEFINED",
"safety": "NOT_DEFINED",
"subsequentSystemAvailability": "NONE",
"subsequentSystemConfidentiality": "NONE",
"subsequentSystemIntegrity": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"vulnerableSystemAvailability": "NONE",
"vulnerableSystemConfidentiality": "HIGH",
"vulnerableSystemIntegrity": "NONE"
},
"source": "PSIRT@rockwellautomation.com",
"type": "Secondary"
}
]
},
"published": "2024-06-14T15:15:51.940",
"references": [
{
"source": "PSIRT@rockwellautomation.com",
"tags": [
"Broken Link"
],
"url": "https://https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1675.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Broken Link"
],
"url": "https://https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1675.html"
}
],
"sourceIdentifier": "PSIRT@rockwellautomation.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-287"
}
],
"source": "PSIRT@rockwellautomation.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-287"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "FactoryTalk\u00ae View SE",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "v12"
}
]
}
],
"source": "PSIRT@rockwellautomation.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:rockwellautomation:factorytalk_view:*:*:*:*:se:*:*:*",
"matchCriteriaId": "EFF3850B-DE22-4996-8B0B-1D1B8D36D62A",
"versionEndExcluding": "14.0",
"versionStartIncluding": "12.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A user authentication vulnerability exists in the Rockwell Automation FactoryTalk\u00ae View SE v12. The vulnerability allows a user from a remote system with FTView to send a packet to the customer\u2019s server to view an HMI project. This action is allowed without proper authentication verification."
},
{
"lang": "es",
"value": "Existe una vulnerabilidad de autenticaci\u00f3n de usuario en Rockwell Automation FactoryTalk\u00ae View SE v12. La vulnerabilidad permite a un usuario desde un sistema remoto con FTView enviar un paquete al servidor del cliente para ver un proyecto HMI. Esta acci\u00f3n est\u00e1 permitida sin una verificaci\u00f3n de autenticaci\u00f3n adecuada."
}
],
"id": "CVE-2024-37367",
"lastModified": "2026-06-17T07:38:13.927",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "PSIRT@rockwellautomation.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-37367",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-17T15:37:14.017276Z",
"version": "2.0.3"
}
}
]
},
"published": "2024-06-14T15:15:51.940",
"references": [
{
"source": "PSIRT@rockwellautomation.com",
"tags": [
"Broken Link"
],
"url": "https://https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1675.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Broken Link"
],
"url": "https://https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1675.html"
}
],
"sourceIdentifier": "PSIRT@rockwellautomation.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-287"
}
],
"source": "PSIRT@rockwellautomation.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-287"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2025-05-28T20:27:56+00:00",
"cve": "CVE-2024-37367",
"id": "CVE-2024-37367",
"initial_release_date": "2024-06-13T13:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "Rockwell Automation FactoryTalk\u00ae View SE v12 Information Leakage Vulnerability via Authentication Restriction",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2024/cve-2024-37367.json",
"version": "3"
},
"vulnrichment": {
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-37367",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-17T15:37:14.017276Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-17T15:37:21.571Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "FactoryTalk\u00ae View SE",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "v12"
}
]
}
],
"datePublic": "2024-06-13T13:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA user authentication vulnerability exists in the Rockwell Automation FactoryTalk\u00ae View SE v12. The vulnerability allows a user from a remote system with FTView to send a packet to the customer\u2019s server to view an HMI project. This action is allowed without proper authentication verification.\u003c/span\u003e\n\n"
}
],
"value": "A user authentication vulnerability exists in the Rockwell Automation FactoryTalk\u00ae View SE v12. The vulnerability allows a user from a remote system with FTView to send a packet to the customer\u2019s server to view an HMI project. This action is allowed without proper authentication verification."
}
],
"impacts": [
{
"capecId": "CAPEC-114",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-114 Authentication Abuse"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287 Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-14T14:17:54.951Z",
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
"shortName": "Rockwell"
},
"references": [
{
"url": "https://https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1675.html"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cul\u003e\u003cli\u003eCorrected in software version v14.0. \u003c/li\u003e\u003cli\u003e\u003cp\u003eUsers using the affected software, who are not able to upgrade to one of the corrected versions, are encouraged to apply security best practices, where possible.\u202f\u202f\u202f\u003c/p\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003eIt is recommended that users enforce proper access controls within the network and segment networks containing sensitive information using IPSec: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1090456\"\u003ehttps://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1090456\u003c/a\u003e\u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\"\u003eSecurity Best Practices\u003c/a\u003e\u003c/p\u003e\u003c/li\u003e\u003c/ul\u003e\u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e"
}
],
"value": "* Corrected in software version v14.0. \n * Users using the affected software, who are not able to upgrade to one of the corrected versions, are encouraged to apply security best practices, where possible.\u202f\u202f\u202f\n\n * It is recommended that users enforce proper access controls within the network and segment networks containing sensitive information using IPSec: https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1090456 \n\n\n\n\n * Security Best Practices https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight"
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "Rockwell Automation FactoryTalk\u00ae View SE v12 Information Leakage Vulnerability via Authentication Restriction",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
"assignerShortName": "Rockwell",
"cveId": "CVE-2024-37367",
"datePublished": "2024-06-14T14:17:54.951Z",
"dateReserved": "2024-06-06T20:18:27.551Z",
"dateUpdated": "2024-06-17T15:37:26.533Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Loading…
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.
Loading…