cve-2024-54005
Vulnerability from cvelistv5
Published
2024-12-10 13:54
Modified
2024-12-10 17:17
Summary
A vulnerability has been identified in COMOS V10.3 (All versions < V10.3.3.5.8), COMOS V10.4.0 (All versions), COMOS V10.4.1 (All versions), COMOS V10.4.2 (All versions), COMOS V10.4.3 (All versions < V10.4.3.0.47), COMOS V10.4.4 (All versions < V10.4.4.2), COMOS V10.4.4.1 (All versions < V10.4.4.1.21). The PDMS/E3D Engineering Interface improperly handles XML External Entity (XXE) entries when communicating with an external application. This could allow an attacker to extract any file with a known location on the user's system or accessible network folders by injecting malicious data into the communication channel between the two systems.
Impacted products
Vendor Product Version
Siemens COMOS V10.4.0 Version: 0   < *
Siemens COMOS V10.4.1 Version: 0   < *
Siemens COMOS V10.4.2 Version: 0   < *
Siemens COMOS V10.4.3 Version: 0   < V10.4.3.0.47
Siemens COMOS V10.4.4 Version: 0   < V10.4.4.2
Siemens COMOS V10.4.4.1 Version: 0   < V10.4.4.1.21
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-54005",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-12-10T15:16:40.996944Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-12-10T17:17:46.788Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "COMOS V10.3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.3.3.5.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "COMOS V10.4.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "COMOS V10.4.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "COMOS V10.4.2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "COMOS V10.4.3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.4.3.0.47",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "COMOS V10.4.4",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.4.4.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "COMOS V10.4.4.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.4.4.1.21",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in COMOS V10.3 (All versions \u003c V10.3.3.5.8), COMOS V10.4.0 (All versions), COMOS V10.4.1 (All versions), COMOS V10.4.2 (All versions), COMOS V10.4.3 (All versions \u003c V10.4.3.0.47), COMOS V10.4.4 (All versions \u003c V10.4.4.2), COMOS V10.4.4.1 (All versions \u003c V10.4.4.1.21). The PDMS/E3D Engineering Interface improperly handles XML External Entity (XXE) entries when communicating with an external application. This could allow an attacker to extract any file with a known location on the user\u0027s system or accessible network folders by injecting malicious data into the communication channel between the two systems."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 5.1,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-611",
              "description": "CWE-611: Improper Restriction of XML External Entity Reference",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-12-10T13:54:15.994Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-701627.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2024-54005",
    "datePublished": "2024-12-10T13:54:15.994Z",
    "dateReserved": "2024-11-26T16:33:29.218Z",
    "dateUpdated": "2024-12-10T17:17:46.788Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-54005\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2024-12-10T14:30:47.037\",\"lastModified\":\"2024-12-10T14:30:47.037\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in COMOS V10.3 (All versions \u003c V10.3.3.5.8), COMOS V10.4.0 (All versions), COMOS V10.4.1 (All versions), COMOS V10.4.2 (All versions), COMOS V10.4.3 (All versions \u003c V10.4.3.0.47), COMOS V10.4.4 (All versions \u003c V10.4.4.2), COMOS V10.4.4.1 (All versions \u003c V10.4.4.1.21). The PDMS/E3D Engineering Interface improperly handles XML External Entity (XXE) entries when communicating with an external application. This could allow an attacker to extract any file with a known location on the user\u0027s system or accessible network folders by injecting malicious data into the communication channel between the two systems.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en COMOS V10.3 (todas las versiones \u0026lt; V10.3.3.5.8), COMOS V10.4.0 (todas las versiones), COMOS V10.4.1 (todas las versiones), COMOS V10.4.2 (todas las versiones), COMOS V10.4.3 (todas las versiones \u0026lt; V10.4.3.0.47), COMOS V10.4.4 (todas las versiones \u0026lt; V10.4.4.2), COMOS V10.4.4.1 (todas las versiones \u0026lt; V10.4.4.1.21). La interfaz de ingenier\u00eda PDMS/E3D maneja incorrectamente las entradas de entidad externa XML (XXE) cuando se comunica con una aplicaci\u00f3n externa. Esto podr\u00eda permitir que un atacante extraiga cualquier archivo con una ubicaci\u00f3n conocida en el sistema del usuario o carpetas de red accesibles inyectando datos maliciosos en el canal de comunicaci\u00f3n entre los dos sistemas.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:L/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":5.9,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"PRESENT\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"vulnerableSystemConfidentiality\":\"HIGH\",\"vulnerableSystemIntegrity\":\"NONE\",\"vulnerableSystemAvailability\":\"NONE\",\"subsequentSystemConfidentiality\":\"NONE\",\"subsequentSystemIntegrity\":\"NONE\",\"subsequentSystemAvailability\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirements\":\"NOT_DEFINED\",\"integrityRequirements\":\"NOT_DEFINED\",\"availabilityRequirements\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnerableSystemConfidentiality\":\"NOT_DEFINED\",\"modifiedVulnerableSystemIntegrity\":\"NOT_DEFINED\",\"modifiedVulnerableSystemAvailability\":\"NOT_DEFINED\",\"modifiedSubsequentSystemConfidentiality\":\"NOT_DEFINED\",\"modifiedSubsequentSystemIntegrity\":\"NOT_DEFINED\",\"modifiedSubsequentSystemAvailability\":\"NOT_DEFINED\",\"safety\":\"NOT_DEFINED\",\"automatable\":\"NOT_DEFINED\",\"recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":5.1,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.4,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-611\"}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-701627.html\",\"source\":\"productcert@siemens.com\"}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.