CVE-2024-8232 (GCVE-0-2024-8232)

Vulnerability from cvelistv5 – Published: 2024-09-10 19:44 – Updated: 2024-09-12 13:36
VLAI?
Title
iniNet Solutions SpiderControl SCADA Web Server Unrestricted Upload of File with Dangerous Type
Summary
SpiderControl SCADA Web Server has a vulnerability that could allow an attacker to upload specially crafted malicious files without authentication.
CWE
  • CWE-434 - Unrestricted Upload of File with Dangerous Type
Assigner
Impacted products
Credits
elcazators ELEX FEIGONG RESEARCH INSTITUTE of Elex CyberSecurity, Inc reported this vulnerability to CERT/CC.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:spidercontrol:scada_webserver:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "scada_webserver",
            "vendor": "spidercontrol",
            "versions": [
              {
                "lessThanOrEqual": "2.09",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-8232",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-12T13:34:02.939872Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-12T13:36:10.295Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SpiderControl SCADA Web Server",
          "vendor": "iniNet Solutions GmbH",
          "versions": [
            {
              "lessThanOrEqual": "v2.09",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "elcazators ELEX FEIGONG RESEARCH INSTITUTE of Elex CyberSecurity, Inc reported this vulnerability to CERT/CC."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "SpiderControl SCADA Web Server has a vulnerability that could allow an \nattacker to upload specially crafted malicious files without \nauthentication."
            }
          ],
          "value": "SpiderControl SCADA Web Server has a vulnerability that could allow an \nattacker to upload specially crafted malicious files without \nauthentication."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-434",
              "description": "CWE-434 Unrestricted Upload of File with Dangerous Type",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-10T19:44:18.096Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-254-02"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "IniNet Solutions has released a new version of SpiderControl SCADA \nServer, (3.2.2), to address this issue. It can be found at the following\n location: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://spidercontrol.net/download/download-area-2/?lang=en\"\u003ehttps://spidercontrol.net/download/download-area-2/?lang=en\u003c/a\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "IniNet Solutions has released a new version of SpiderControl SCADA \nServer, (3.2.2), to address this issue. It can be found at the following\n location:  https://spidercontrol.net/download/download-area-2/?lang=en"
        }
      ],
      "source": {
        "advisory": "ICSA-24-254-02",
        "discovery": "EXTERNAL"
      },
      "title": "iniNet Solutions SpiderControl SCADA Web Server Unrestricted Upload of File with Dangerous Type",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "IniNet Solutions reminds users that the webserver is designed to be used\n in a protected environment. IniNet Solutions GmbH recommends that users\n never connect control system software directly to the Internet. If a \nuser must connect to the Internet, IniNet Solutions GmbH recommends \nusing a managed infrastructure to do so.\n\n\u003cbr\u003e"
            }
          ],
          "value": "IniNet Solutions reminds users that the webserver is designed to be used\n in a protected environment. IniNet Solutions GmbH recommends that users\n never connect control system software directly to the Internet. If a \nuser must connect to the Internet, IniNet Solutions GmbH recommends \nusing a managed infrastructure to do so."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2024-8232",
    "datePublished": "2024-09-10T19:44:18.096Z",
    "dateReserved": "2024-08-27T13:40:41.730Z",
    "dateUpdated": "2024-09-12T13:36:10.295Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "descriptions": "[{\"lang\": \"en\", \"value\": \"SpiderControl SCADA Web Server has a vulnerability that could allow an \\nattacker to upload specially crafted malicious files without \\nauthentication.\"}, {\"lang\": \"es\", \"value\": \"El servidor web SpiderControl SCADA tiene una vulnerabilidad que podr\\u00eda permitir a un atacante cargar archivos maliciosos especialmente manipulados sin autenticaci\\u00f3n.\"}]",
      "id": "CVE-2024-8232",
      "lastModified": "2024-09-11T16:26:11.920",
      "metrics": "{\"cvssMetricV40\": [{\"source\": \"ics-cert@hq.dhs.gov\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"4.0\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\", \"baseScore\": 8.7, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"vulnerableSystemConfidentiality\": \"NONE\", \"vulnerableSystemIntegrity\": \"HIGH\", \"vulnerableSystemAvailability\": \"NONE\", \"subsequentSystemConfidentiality\": \"NONE\", \"subsequentSystemIntegrity\": \"NONE\", \"subsequentSystemAvailability\": \"NONE\", \"exploitMaturity\": \"NOT_DEFINED\", \"confidentialityRequirements\": \"NOT_DEFINED\", \"integrityRequirements\": \"NOT_DEFINED\", \"availabilityRequirements\": \"NOT_DEFINED\", \"modifiedAttackVector\": \"NOT_DEFINED\", \"modifiedAttackComplexity\": \"NOT_DEFINED\", \"modifiedAttackRequirements\": \"NOT_DEFINED\", \"modifiedPrivilegesRequired\": \"NOT_DEFINED\", \"modifiedUserInteraction\": \"NOT_DEFINED\", \"modifiedVulnerableSystemConfidentiality\": \"NOT_DEFINED\", \"modifiedVulnerableSystemIntegrity\": \"NOT_DEFINED\", \"modifiedVulnerableSystemAvailability\": \"NOT_DEFINED\", \"modifiedSubsequentSystemConfidentiality\": \"NOT_DEFINED\", \"modifiedSubsequentSystemIntegrity\": \"NOT_DEFINED\", \"modifiedSubsequentSystemAvailability\": \"NOT_DEFINED\", \"safety\": \"NOT_DEFINED\", \"automatable\": \"NOT_DEFINED\", \"recovery\": \"NOT_DEFINED\", \"valueDensity\": \"NOT_DEFINED\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\", \"providerUrgency\": \"NOT_DEFINED\"}}], \"cvssMetricV31\": [{\"source\": \"ics-cert@hq.dhs.gov\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.6}]}",
      "published": "2024-09-10T20:15:05.060",
      "references": "[{\"url\": \"https://www.cisa.gov/news-events/ics-advisories/icsa-24-254-02\", \"source\": \"ics-cert@hq.dhs.gov\"}]",
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Awaiting Analysis",
      "weaknesses": "[{\"source\": \"ics-cert@hq.dhs.gov\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-434\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-8232\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2024-09-10T20:15:05.060\",\"lastModified\":\"2024-09-11T16:26:11.920\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"SpiderControl SCADA Web Server has a vulnerability that could allow an \\nattacker to upload specially crafted malicious files without \\nauthentication.\"},{\"lang\":\"es\",\"value\":\"El servidor web SpiderControl SCADA tiene una vulnerabilidad que podr\u00eda permitir a un atacante cargar archivos maliciosos especialmente manipulados sin autenticaci\u00f3n.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":8.7,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"NONE\",\"vulnIntegrityImpact\":\"HIGH\",\"vulnAvailabilityImpact\":\"NONE\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-434\"}]}],\"references\":[{\"url\":\"https://www.cisa.gov/news-events/ics-advisories/icsa-24-254-02\",\"source\":\"ics-cert@hq.dhs.gov\"}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-8232\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-09-12T13:34:02.939872Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:a:spidercontrol:scada_webserver:*:*:*:*:*:*:*:*\"], \"vendor\": \"spidercontrol\", \"product\": \"scada_webserver\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"2.09\"}], \"defaultStatus\": \"unaffected\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-09-12T13:36:04.981Z\"}}], \"cna\": {\"title\": \"iniNet Solutions SpiderControl SCADA Web Server Unrestricted Upload of File with Dangerous Type\", \"source\": {\"advisory\": \"ICSA-24-254-02\", \"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"elcazators ELEX FEIGONG RESEARCH INSTITUTE of Elex CyberSecurity, Inc reported this vulnerability to CERT/CC.\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.5, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"NONE\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}, {\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 8.7, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"NONE\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"HIGH\", \"subAvailabilityImpact\": \"NONE\", \"vulnAvailabilityImpact\": \"NONE\", \"subConfidentialityImpact\": \"NONE\", \"vulnConfidentialityImpact\": \"NONE\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"iniNet Solutions GmbH\", \"product\": \"SpiderControl SCADA Web Server\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"v2.09\"}], \"defaultStatus\": \"unaffected\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"IniNet Solutions has released a new version of SpiderControl SCADA \\nServer, (3.2.2), to address this issue. It can be found at the following\\n location:  https://spidercontrol.net/download/download-area-2/?lang=en\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"IniNet Solutions has released a new version of SpiderControl SCADA \\nServer, (3.2.2), to address this issue. It can be found at the following\\n location: \u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\" href=\\\"https://spidercontrol.net/download/download-area-2/?lang=en\\\"\u003ehttps://spidercontrol.net/download/download-area-2/?lang=en\u003c/a\u003e\\n\\n\u003cbr\u003e\", \"base64\": false}]}], \"references\": [{\"url\": \"https://www.cisa.gov/news-events/ics-advisories/icsa-24-254-02\"}], \"workarounds\": [{\"lang\": \"en\", \"value\": \"IniNet Solutions reminds users that the webserver is designed to be used\\n in a protected environment. IniNet Solutions GmbH recommends that users\\n never connect control system software directly to the Internet. If a \\nuser must connect to the Internet, IniNet Solutions GmbH recommends \\nusing a managed infrastructure to do so.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"IniNet Solutions reminds users that the webserver is designed to be used\\n in a protected environment. IniNet Solutions GmbH recommends that users\\n never connect control system software directly to the Internet. If a \\nuser must connect to the Internet, IniNet Solutions GmbH recommends \\nusing a managed infrastructure to do so.\\n\\n\u003cbr\u003e\", \"base64\": false}]}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"SpiderControl SCADA Web Server has a vulnerability that could allow an \\nattacker to upload specially crafted malicious files without \\nauthentication.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"SpiderControl SCADA Web Server has a vulnerability that could allow an \\nattacker to upload specially crafted malicious files without \\nauthentication.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-434\", \"description\": \"CWE-434 Unrestricted Upload of File with Dangerous Type\"}]}], \"providerMetadata\": {\"orgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"shortName\": \"icscert\", \"dateUpdated\": \"2024-09-10T19:44:18.096Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2024-8232\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-09-12T13:36:10.295Z\", \"dateReserved\": \"2024-08-27T13:40:41.730Z\", \"assignerOrgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"datePublished\": \"2024-09-10T19:44:18.096Z\", \"assignerShortName\": \"icscert\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…