CVE-2025-14655 (GCVE-0-2025-14655)

Vulnerability from cvelistv5 – Published: 2025-12-14 10:32 – Updated: 2025-12-15 21:13
VLAI?
Title
Tenda AC20 httpd SetSysAutoRebbotCfg formSetRebootTimer stack-based overflow
Summary
A security flaw has been discovered in Tenda AC20 16.03.08.12. The impacted element is the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg of the component httpd. Performing manipulation of the argument rebootTime results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been released to the public and may be exploited.
CWE
Assigner
References
Impacted products
Vendor Product Version
Tenda AC20 Affected: 16.03.08.12
Create a notification for this product.
Credits
jiahui2888 (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-14655",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-12-15T21:13:40.307321Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-12-15T21:13:57.367Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "httpd"
          ],
          "product": "AC20",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.08.12"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "jiahui2888 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A security flaw has been discovered in Tenda AC20 16.03.08.12. The impacted element is the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg of the component httpd. Performing manipulation of the argument rebootTime results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been released to the public and may be exploited."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-12-14T10:32:08.489Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-336388 | Tenda AC20 httpd SetSysAutoRebbotCfg formSetRebootTimer stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.336388"
        },
        {
          "name": "VDB-336388 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.336388"
        },
        {
          "name": "Submit #712910 | Tenda AC20 V16.03.08.12 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.712910"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN13/AC20_SetSysAutoRebbotCfg.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-12-13T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-12-13T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-12-13T10:53:20.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC20 httpd SetSysAutoRebbotCfg formSetRebootTimer stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-14655",
    "datePublished": "2025-12-14T10:32:08.489Z",
    "dateReserved": "2025-12-13T09:48:13.345Z",
    "dateUpdated": "2025-12-15T21:13:57.367Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2025-14655\",\"sourceIdentifier\":\"cna@vuldb.com\",\"published\":\"2025-12-14T11:15:39.563\",\"lastModified\":\"2025-12-19T14:20:24.800\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A security flaw has been discovered in Tenda AC20 16.03.08.12. The impacted element is the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg of the component httpd. Performing manipulation of the argument rebootTime results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been released to the public and may be exploited.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":7.4,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"HIGH\",\"vulnIntegrityImpact\":\"HIGH\",\"vulnAvailabilityImpact\":\"HIGH\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"PROOF_OF_CONCEPT\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:C/I:C/A:C\",\"baseScore\":9.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":8.0,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-119\"},{\"lang\":\"en\",\"value\":\"CWE-121\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:tenda:ac20_firmware:16.03.08.12:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5745E546-E2E6-4D74-8DEE-F509B0D13B05\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:tenda:ac20:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3F7CEE4E-8C63-4ED5-9AE1-A1CFEA555E7C\"}]}]}],\"references\":[{\"url\":\"https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN13/AC20_SetSysAutoRebbotCfg.md\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://vuldb.com/?ctiid.336388\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Permissions Required\",\"VDB Entry\"]},{\"url\":\"https://vuldb.com/?id.336388\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://vuldb.com/?submit.712910\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://www.tenda.com.cn/\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Product\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-14655\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"poc\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-12-15T21:13:40.307321Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-12-15T21:13:51.721Z\"}}], \"cna\": {\"title\": \"Tenda AC20 httpd SetSysAutoRebbotCfg formSetRebootTimer stack-based overflow\", \"credits\": [{\"lang\": \"en\", \"type\": \"reporter\", \"value\": \"jiahui2888 (VulDB User)\"}], \"metrics\": [{\"cvssV4_0\": {\"version\": \"4.0\", \"baseScore\": 8.7, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P\"}}, {\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R\"}}, {\"cvssV3_0\": {\"version\": \"3.0\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R\"}}, {\"cvssV2_0\": {\"version\": \"2.0\", \"baseScore\": 9, \"vectorString\": \"AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR\"}}], \"affected\": [{\"vendor\": \"Tenda\", \"modules\": [\"httpd\"], \"product\": \"AC20\", \"versions\": [{\"status\": \"affected\", \"version\": \"16.03.08.12\"}]}], \"timeline\": [{\"lang\": \"en\", \"time\": \"2025-12-13T00:00:00.000Z\", \"value\": \"Advisory disclosed\"}, {\"lang\": \"en\", \"time\": \"2025-12-13T01:00:00.000Z\", \"value\": \"VulDB entry created\"}, {\"lang\": \"en\", \"time\": \"2025-12-13T10:53:20.000Z\", \"value\": \"VulDB entry last update\"}], \"references\": [{\"url\": \"https://vuldb.com/?id.336388\", \"name\": \"VDB-336388 | Tenda AC20 httpd SetSysAutoRebbotCfg formSetRebootTimer stack-based overflow\", \"tags\": [\"vdb-entry\", \"technical-description\"]}, {\"url\": \"https://vuldb.com/?ctiid.336388\", \"name\": \"VDB-336388 | CTI Indicators (IOB, IOC, IOA)\", \"tags\": [\"signature\", \"permissions-required\"]}, {\"url\": \"https://vuldb.com/?submit.712910\", \"name\": \"Submit #712910 | Tenda AC20 V16.03.08.12 Buffer Overflow\", \"tags\": [\"third-party-advisory\"]}, {\"url\": \"https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/Tenda/VULN13/AC20_SetSysAutoRebbotCfg.md\", \"tags\": [\"exploit\"]}, {\"url\": \"https://www.tenda.com.cn/\", \"tags\": [\"product\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A security flaw has been discovered in Tenda AC20 16.03.08.12. The impacted element is the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg of the component httpd. Performing manipulation of the argument rebootTime results in stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been released to the public and may be exploited.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-121\", \"description\": \"Stack-based Buffer Overflow\"}]}, {\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-119\", \"description\": \"Memory Corruption\"}]}], \"providerMetadata\": {\"orgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"shortName\": \"VulDB\", \"dateUpdated\": \"2025-12-14T10:32:08.489Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2025-14655\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-12-15T21:13:57.367Z\", \"dateReserved\": \"2025-12-13T09:48:13.345Z\", \"assignerOrgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"datePublished\": \"2025-12-14T10:32:08.489Z\", \"assignerShortName\": \"VulDB\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…