CVE-2025-30476 (GCVE-0-2025-30476)

Vulnerability from cvelistv5 – Published: 2025-05-15 18:45 – Updated: 2025-05-16 18:25
VLAI?
Summary
Dell PowerScale InsightIQ, version 5.2, contains an uncontrolled resource consumption vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to denial of service.
CWE
  • CWE-400 - Uncontrolled Resource Consumption
Assigner
References
Impacted products
Vendor Product Version
Dell PowerScale InsightIQ Affected: 5.2 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-30476",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-05-16T18:25:04.844272Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-05-16T18:25:54.661Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerScale InsightIQ",
          "vendor": "Dell",
          "versions": [
            {
              "status": "affected",
              "version": "5.2",
              "versionType": "semver"
            }
          ]
        }
      ],
      "datePublic": "2025-05-15T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell PowerScale InsightIQ, \u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eversion 5.2, contains an uncontrolled resource consumption vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to denial of service.\u003c/span\u003e"
            }
          ],
          "value": "Dell PowerScale InsightIQ, version 5.2, contains an uncontrolled resource consumption vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to denial of service."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400: Uncontrolled Resource Consumption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-05-15T18:45:20.520Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000317889/dsa-2025-186-security-update-for-dell-powerscale-inightiq-multiple-security-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2025-30476",
    "datePublished": "2025-05-15T18:45:20.520Z",
    "dateReserved": "2025-03-23T18:45:23.728Z",
    "dateUpdated": "2025-05-16T18:25:54.661Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2025-30476\",\"sourceIdentifier\":\"security_alert@emc.com\",\"published\":\"2025-05-15T19:15:56.850\",\"lastModified\":\"2025-10-30T15:58:52.890\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Dell PowerScale InsightIQ, version 5.2, contains an uncontrolled resource consumption vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to denial of service.\"},{\"lang\":\"es\",\"value\":\"Dell PowerScale InsightIQ, versi\u00f3n 5.2, contiene una vulnerabilidad de consumo descontrolado de recursos. Un atacante no autenticado con acceso remoto podr\u00eda explotar esta vulnerabilidad, lo que provocar\u00eda una denegaci\u00f3n de servicio.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L\",\"baseScore\":5.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":3.9,\"impactScore\":1.4},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-400\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:dell:insightiq:5.2.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3FA4C173-E3D2-4D5E-87C6-E754343206A8\"}]}]}],\"references\":[{\"url\":\"https://www.dell.com/support/kbdoc/en-us/000317889/dsa-2025-186-security-update-for-dell-powerscale-inightiq-multiple-security-vulnerabilities\",\"source\":\"security_alert@emc.com\",\"tags\":[\"Vendor Advisory\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-30476\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-05-16T18:25:04.844272Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-05-16T18:25:50.237Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 5.3, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"LOW\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"NONE\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Dell\", \"product\": \"PowerScale InsightIQ\", \"versions\": [{\"status\": \"affected\", \"version\": \"5.2\", \"versionType\": \"semver\"}], \"defaultStatus\": \"unaffected\"}], \"datePublic\": \"2025-05-15T17:00:00.000Z\", \"references\": [{\"url\": \"https://www.dell.com/support/kbdoc/en-us/000317889/dsa-2025-186-security-update-for-dell-powerscale-inightiq-multiple-security-vulnerabilities\", \"tags\": [\"vendor-advisory\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Dell PowerScale InsightIQ, version 5.2, contains an uncontrolled resource consumption vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to denial of service.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003eDell PowerScale InsightIQ, \u003c/span\u003e\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003eversion 5.2, contains an uncontrolled resource consumption vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to denial of service.\u003c/span\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-400\", \"description\": \"CWE-400: Uncontrolled Resource Consumption\"}]}], \"providerMetadata\": {\"orgId\": \"c550e75a-17ff-4988-97f0-544cde3820fe\", \"shortName\": \"dell\", \"dateUpdated\": \"2025-05-15T18:45:20.520Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2025-30476\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-05-16T18:25:54.661Z\", \"dateReserved\": \"2025-03-23T18:45:23.728Z\", \"assignerOrgId\": \"c550e75a-17ff-4988-97f0-544cde3820fe\", \"datePublished\": \"2025-05-15T18:45:20.520Z\", \"assignerShortName\": \"dell\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…